Loading...
HomeMy WebLinkAboutE0.3ElectricalSchedules315 North 25th Street, Suite 102 Billings, MT 59101 Phone: 406.656.6000 Project # 6804.001 COPYRIGHT © 2021 THESE DOCUMENTS, IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT; ARE THE SOLE PROPERTY OF STUDIO 4 ARCHITECTS. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON THE SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION, OR ADAPTATION WITHOUT THE EXPRESS WRITTEN CONSENT OF STUDIO 4 ARCHITECTS IS STRICTLY PROHIBITED. project: set: dates: sheet: PRE: CRS: CDS: REV: REV: PROJECT NO. DRAWN BY: CHECKED BY: 2-22-21 - - - 27 Shiloh Road Suite 8 Billings, MT 59106 ph: 406.656.1714 fx: 406.656.1715 web: studio4architects.com STUDIO ARCHITECTS 8-6-21 e0.3PRELIMINARY -NOT FOR CONSTRUCTIONTJ JK 2104Stillwater HospiceEvergreen DriveSCHEDULESBozeman, Mt<1> PROVIDE A 5ma GFI CB Notes: Receptacle 18960 VA 76.37% 14480 VA Total Est. Demand:194 A Power 24800 VA 100.00% 24800 VA Total Conn.:208 A Motor 3476 VA 108.63% 3776 VA Total Est. Demand:46453 VA Lighting 2726 VA 125.00% 3407 VA Total Conn. Load:49972 VA Heating 100 VA 100.00% 100 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:202 A 215 A Total Load:24195 VA 25779 VA 53 RCPT - BREAK 105 DISHWASHER & GD <1> Receptacle 20 A 1 180 4200 54 51 RCPT - BREAK 105 COUNTERTOP Receptacle 20 A 1 360 4200 2 60 A Power RTU-2 ROOF TOP UNIT #2 52 49 RCPT - BREAK 105 REFRIGERATOR <1> Receptacle 20 A 1 750 4200 50 47 RCPT - BREAK 105 & HALLWAY Receptacle 20 A 1 1080 4200 2 60 A Power RTU-1 ROOF TOP UNIT #1 48 45 RCPT - CONFERENCE 102 - FLOOR/TV Motor;... 20 A 1 1180 2250 46 43 RCPT - CONFERENCE 102 Receptacle 20 A 1 900 2250 2 30 A Power HWH -1, ATTIC 44 41 RCPT - RECEPTION 101 Receptacle 20 A 1 540 1500 42 39 RCPT - RECEPTION 101 Receptacle 20 A 1 540 1500 2 20 A Power BB-1 & BB-2 BASEBOARD HEATERS ATTIC 40 37 RCPT - NURSE 106 Receptacle 20 A 1 540 100 1 20 A Heating UH-1 UNIT HEATER DME GARAGE 38 35 RCPT - NURSE 106 Receptacle 20 A 1 540 1200 1 20 A Motor SOUTH OVERHEAD DOOR 36 33 RCPT - BEREAVEMENT 117 Receptacle 20 A 1 720 1200 1 20 A Motor NORTH OVERHEAD DOOR 34 31 RCPT - MED STORAGE 104 & HALLWAY Receptacle 20 A 1 900 1440 1 20 A Receptacle RCPT - DME 118 32 29 RCPT - COPY 101 Receptacle 20 A 1 360 1080 1 20 A Receptacle RCPT - DME 118 30 27 RCPT - COPIER, COPY 101 Receptacle 20 A 1 750 960 1 20 A Motor EF-3 DME - ROOF 28 25 RCPT - COPY 101 Receptacle 20 A 1 360 0 1 20 A -- SPARE 26 23 RCPT - OFFICE 110 Receptacle 20 A 1 720 0 1 20 A -- SPARE 24 21 RCPT - OFFICE 109 Receptacle 20 A 1 720 0 1 20 A -- SPARE 22 19 RCPT - OFFICE 108 Receptacle 20 A 1 720 0 1 20 A -- SPARE 20 17 RCPT - OFFICE 107 Receptacle 20 A 1 720 0 1 20 A -- SPARE 18 15 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 16 13 LIGHTING CONTROL PANEL Power 20 A 1 500 0 1 20 A -- SPARE 14 11 LTG - SITE POLES Lighting 20 A 1 147 900 1 20 A Receptacle RCPT - RR 111, RR 112, STOR. 113, HALLWAY 12 9 LTG - EXTERIOR BUILDING Lighting 20 A 1 148 180 1 20 A Receptacle RCPT - TELCOM BACK BOARD STORAGE 113 10 7 LTG - DME & ATTIC Lighting 20 A 1 541 720 1 20 A Receptacle RCPT - OFFICE 111 8 5 LTG - NURSE & HALLWAY Lighting 20 A 1 906 720 1 20 A Receptacle RCPT - OFFICE 113 6 3 LTG - OFFICE 107,108,109,110, MED ST, CONF Lighting 20 A 1 1001 720 1 20 A Receptacle RCPT - OFFICE 115 4 1 LTG - OFFICE 114,115,116, RR 111,112 Lighting; Motor 20 A 1 466 720 1 20 A Receptacle RCPT - HALLWAY & EXTERIOR 2 CKT Circuit Description Load Classification Trip Poles A B Poles Trip Load Classification Circuit Description CKT MANUFACTURER/ TYPE: SQ D, NQ Notes: Enclosure:Nema 1 Mounting:Surface Wires:3 Mains Rating:400 A Supply From:METER SOCKET Phases:1 Mains Type:MLO Location:Volts:120/240 Single A.I.C. Rating:13,134 Branch Panel: A1 LUMINAIRE SCHEDULE TYPE LAMPS LOAD (W) OUTPUT (LM, NOMINAL) CCT (K)DESCRIPTION MFR CATALOG NO. OR SERIES MOUNTING VOLTAGE NOTES B1 LED 32 W 4,000 3,500 2X4 VOLUMETRIC LED TROFFER ACUITY 2BLT4 40L ADP GZ10 LP835 CEILING/RECESSED 120 V 2 B1E LED 32 W 4,000 3,500 2X4 VOLUMETRIC LED TROFFER W/ EM BATTERY BACKUP ACUITY 2BLT4 40L ADP GZ10 LP835 EL14 CEILING/RECESSED 120 V 2 B2 LED 27 W 3,300 3,500 2X2 VOLUMETRIC LED TROFFER ACUITY 2BLT2 33L ADP GZ10 LP835 CEILING/RECESSED 120 V 2 B2E LED 27 W 3,300 3,500 2X2 VOLUMETRIC LED TROFFER W/ EM BATTERY BACKUP ACUITY 2BLT2 33L ADP GZ10 LP835 EL14 CEILING/RECESSED 120 V 2 B3 LED 38 W 4,000 3,500 2X4 LED FLAT PANEL TROFFER ACUITY EPANL 2X4 400LM 80CRI 35K MIN10 ZT MVOLT CEILING/RECESSED 120 V 2 D1 LED 15 W 1,500 3,500 6" LED DOWNLIGHT W/ 1,500 LUMEN ENGINE ACUITY LDN6 35/15 L06 AR LSS MVOLT GZ10 CEILING RECESSED 120 V 2 E1 LED 16 W 600 3,000 EXTERIOR DECORATIVE SCONCE TECH LIGHTING 700OWTUR 830 18 C * UNV S WALL/SURFACE 6'-9" 120 V 2,6 E2E LED 3 W 225 4,000 BUILDING MOUNTED EXTERIOR LED WALL PACK W/ COLD WEATHER EM BATTERY PACK. FIXTURE ONLY OPERATES IN EMERGENCY MODE TO PROVIDE EGRESS ILLUMINATION. ACUITY AFB OEL * UVOLT N WT CW WALL/SURFACE 7'-6" 120 V 2,6 E3E LED 11 W 1,529 3,000 BUILDING MOUNTED EXTERIOR LED WALL PACK W/ FORWARD THROW OPTICS & COLD WEATHER EM BATTERY PACK. ACUITY WST LED P1 30K VF MVOLT DMG E7WC * WALL/SURFACE 7'-6" 120 V 2,6 E10 LED 11 W 950 3,000 EXTERIOR 6" LED DOWNLIGHT W/ 1,000 LUMEN ENGINE & 3,000K ACUITY LDN6 30/10 L06 AR LSS MVOLT GZ10 CEILING RECESSED 120 V 2 E20 LED 49 W 5,580 3,000 SINGLE HEAD LED FULL CUT OFF SITE LIGHT W/ TYPE 3 OPTICS & HOUSE SIDE SHIELD. HEAD MOUNTED ON A 18' TALL ROUND STEEL POLE THAT CONTAINS AN INTERNAL VIBRATION DAMPER. ACUITY HEAD: DSX0-P2-30K-T3M-MVOLT-RPA-DMG-HS-* POLE: RSS 18’ 4B DM19AS VD DDBXD SITE / POLE 120 V 2,6 E21 LED 49 W 5,458 3,000 SINGLE HEAD LED FULL CUT OFF SITE LIGHT W/ TYPE 4 OPTICS. HEAD IS MOUNTED ON A 18' TALL ROUND STEEL POLE THAT CONTAINS AN INTERNAL VIBRATION DAMPER. ACUITY HEAD: DSX0-P2-30K-T4M-MVOLT-RPA-DMG-* POLE: RSS 18’ 4B DM19AS VD DDBXD SITE / POLE 120 V 2,6 EL1 LED 11 W 1,100 4,000 DUAL LED HEAD EGRESS BATTERY PACK LIGHTING UNIT ACUITY ELM6L UVOLT LTP WALL/SURFACE 7'-6" 120 V 2 F1 LED 60 W 8,386 4,000 8' LED LENSED STRIP WITH REFLECTOR ACUITY TZL1D L96 SMR 6000LM FST MVOLT 35K 80CRI WH CEILING/SURFACE 120 V 2 F2 LED 60 W 8,386 4,000 8' LED LENSED STRIP WITH REFLECTOR AND AIRCRAFT CABLE MOUNTING. ACUITY TZL1D L96 SMR 6000LM FST MVOLT 35K 80CRI WH ZACVH M100 CEILING/ 9'-0" 120 V 2 G1 LED 30 W 1,700 3,500 2' LED DECORATIVE LED VANITY W/ SELECTABLE COLOR TEMPERATURE OUTPUT. SET TO 35K. ACUITY FMVCCLS 24IN MVOLT 30K35K40K 90CRI * WALL/SURFACE 120 V 2,5 P1 LED 72 W 5,832 3,500 30” DIA LOBBY DECORATIVE PENDANT W/ CROSS BEAM BOWL SUPPORT AND CENTER STEM MOUNTING SCOTT ARCH LIGHTING S2435-L72 35K *CEILING / SUSPENDED 120 V 2,6 S1 LED 14 W 1,134 3,500 INTERIOR DECORATIVE SCONCE SCOTT ARCH LIGHTING S3205-L14 35K *WALL/SURFACE 6'-6" 120 V 2,6 U1 LED 15 W 1,187 3,500 30" UNDER CABINET LED LINKABLE LIGHT W/ INTEGRAL TOGGLE SWITCH AND SWITCHABLE KELVIN TEMPERATURE. SET AT 3,500K ACUITY UPLD 30IN SWW4 90CRI WH SURFACE 120 V 2,4 X1 LED 4 W N/A N/A SINGLE FACE EDGE LIT EXIT SIGN W/ RED LETTERING ON A MIRROR FACE AND EMERGENCY BATTERY PACK. ACUITY EDG 1 RMR EL SEE PLANS 120 V 1,2 X10 LED 4 W N/A N/A SINGLE FACE THERMOPLASTIC EXIT SIGN W/ RED LETTERING & EM BATTERY PACK ACUITY LQM S 3 W R 120/277 EL N WALL/SURFACE 120 V 1,2 1. 2. 3. 4. 5. 6. 7. INTEGRAL DISCONNECTS AND OVERLOADS INTEGRAL OVERLOADS SINGLE POINT CONNECTION PROVIDE RECEPTACLE AND DATA CONNECTION FOR PANEL MOUNT ON UNI-STRUT IN FRONT OF UNIT SIZE FUSES IN ACCORDANCE WITH MANUFACTURER'S GUIDELINES FOR INSTALLED EQUIPMENT BB-1 AND BB-2 TO BE CONTROLLED VIA SAME THERMOSTAT A. B. CONTROL WIRING SHALL BE CONCEALED WITHIN WALL CONSTRUCTION, ABOVE CEILING, OR RUN IN CONDUIT. EXPOSED CONTROL WIRING IS UNACCEPTABLE. UNLESS SPECIFICALLY NOTED, ALL FEEDERS SHALL INCLUDE A FULL SIZE NEUTRAL. IT IS THE CONTRACT RESPONSIBILITY TO VERIFY WITH THE MANUFACTURER OF THE ACTUAL EQUIPMENT BEING SUPPLIED WETHER A NEUTRAL IS REQUIRED PRIOR TO ROUGH-IN. NOTES:GENERAL NOTES: BAS CO CONT EF HCP INT L MS OS PS T TC UC VE N/A BUILDING AUTOMATION SYSTEM CARBON MONOXIDE DETECTOR CONTINUOUS OPERATION INTERLOCK WITH EXHAUST FAN HOOD CONTROL PANEL INTEGRAL LIGHT SWITCH MANUAL SWITCH OCCUPANCY SENSOR PRESSURE SWITCH THERMOSTAT TIME CLOCK UNIT CONTROLLER VEHICLE EXHAUST DETECTION SYSTEM NOT APPLICABLE CB CSFD FD FST FW MOCP MSS NFD RCPT RVSS VFD N/A PANELBOARD CIRCUIT BREAKER WITHIN SIGHT OF EQUIPMENT COMBINATION STARTER/DISCONNECT - HOA FUSED DISCONNECT FUSTAT FACTORY-WIRED SINGLE POINT CONNECTION MOTOR OVER-CURRENT PROTECTION MANUAL STARTER SWITCH WITH THERMAL OVERLOADS (1-, 2- OR 3-POLE AS REQUIRED) NON-FUSED DISCONNECT 20A DUPLEX RECEPTACLE (GFCI PROTECTED AS REQUIRED), CORD AND PLUG REDUCED VOLTAGE SOLID-STATE VARIABLE FREQUENCY DRIVE - HOA NOT APPLICABLE 22/22 22/26 23/23 23/26 26/26 FURNISHED AND INSTALLED BY DIV. 22, WIRED BY DIV. 22 FURNISHED AND INSTALLED BY DIV. 22, WIRED BY DIV. 26 FURNISHED AND INSTALLED BY DIV. 23, WIRED BY DIV. 23 FURNISHED AND INSTALLED BY DIV. 23, WIRED BY DIV. 26 FURNISHED AND INSTALLED BY DIV. 26, WIRED BY DIV. 26 CONTROL TYPE:DISCONNECT/STARTER TYPE:DIVISION OF RESPONSIBILITIES: RCP-1 HOTWATER RECIRCULATION PUMP FRAC 120/1 INT 22/22 - FST 26/26 - 15 NOTE 6 1 #12 3/4" HWH-1 WATER HEATER 18.8 240/1 INT 22/22 3 NFD 26/26 - 30 - 1 #10 3/4" PLUMBING FIXTURES UH-1 UNIT HEATER 1A 120/1 T 23/23 3 FST 26/26 - 15 NOTE 6 1 #12 3/4" RTU-2 ROOF TOP UNIT 39.1 MCA 240/1 T 23/23 3 FD 26/26 - 60 NOTE 6 3R #6 3/4" RTU-1 ROOF TOP UNIT 39.1 MCA 240/1 T 23/23 3 FD 26/26 - 60 NOTE 6 3R #6 3/4" EF-3 EXHAUST FAN 8A 120/1 MS 26/26 3 MSS 26/26 - 20 - 3R #12 3/4" EF-2 EXHAUST FAN FRAC 120/1 OS/L 26/26 3 FW 23/26 - - - - #12 3/4" EF-1 EXHAUST FAN FRAC 120/1 OS/L 26/26 3 FW 23/26 - - - - #12 3/4" BB-2 BASEBOARD HEATER 6.25A 240/1 T 26/26 7 N/A 23/26 - - - - #12 3/4" BB-1 BASEBOARD HEATER 6.25A 240/1 T 26/26 7 N/A 23/26 - - - - #12 3/4" MECHANICAL EQUIPMENT LOAD VOLT-PHASE TYPE DIV TYPE DIV SIZE (NEMA) SWITCH (AMPS) FUSE (AMPS) ENCLOSURE (NEMA) COPPER WIRE (AWG) CONDUIT (INCHES) MARK DESCRIPTION ELECTRICAL DATA CONTROL NOTES DISCONNECT / STARTER DISCONNECT FEEDER MEP COORDINATION SCHEDULE GARAGE, DME 118 1. WHEN WALL MOUNTED, LOCATE BOTTOM OF FIXTURE AT 6” ABOVE TOP OF DOOR/ STORE FRONT. 2. PRIOR SUBMITTAL IS REQUIRED. 3. ALTERNATE FIXTURE IS NOT ACCEPTED FOR SUBSTITUTIONS. 4.PROVIDE FIXTURE COMPLETE WITH OPTIONS FOR A FULL, TURNKEY INSTALLATION CONSISTING OF: #UCD JB (SPLICE/ STARTING JUNCTION BOX) AND #UC ERC24 (POWER LEAD IN CONNECTION FROM SPLICE BOX). QUANTITY OF OPTIONS LISTED THAT SHALL BE NEEDED FOR INSTALLATION SHALL BE DETERMINED BY THE EC. 5. MOUNT BOTTOM OF FIXTURE CENTERED AT 6” ABOVE TOP OF MIRROR. SEE ARCHITECT ELEVATIONS. 6.VERIFY FINISH WITH ARCHITECT PRIOR TO ORDERING. PROVIDE 2 CHIP SAMPLES WITH SHOP DRAWING SUBMITTALS OF STANDARD MANUFACTURERS FINISH OFFERINGS FOR SELECTION. THE "*", WHEN SHOWN IN THE PART NUMBER IS TO SIGNIFY THIS NEED. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND PROVIDE ALL MOUNTING, FIRE-RATED, AND IC-RATED ACCESSORIES AS REQUIRED. FOR FIRE-RATED CEILING ASSEMBLIES AND FOR CEILINGS WITH INSULATION, VERIFY ALL RECESSED LUMINAIRE HOUSINGS ARE RATED APPROPRIATELY OR PROVIDE DROP-OVER ENCLOSURES OR TENTS FOR LUMINAIRES. VERIFY THAT DROP-OVER ENCLOSURES OR TENTS ALLOW FOR AIR SPACE AROUND LUMINAIRE PER MANUFACTURER'S RECOMMENDATIONS. ALL MOUNTING HEIGHTS CALLED FOR REGARDING LIGHT FIXTURES SHALL BE TO THE BOTTOM OF FIXTURE AS BASED ON FINISHED FLOOR IN THE BUILDING INTERIOR, OR FINISHED GRADE WHEN LOCATED ON THE BUILDING EXTERIOR, UNO. NOTES:GENERAL NOTE: