E0.2ElectricalDetails
4NS* PANEL A (1) 3" C.O. 5' FROM PAD (1) 3" C.O. PER UTILITY REQUIREMENTS 240/120V, 1PH, 3W PAD-MOUNT XFMR PER UTILITY REQUIREMENTS M COMBINATION 320A METER W/ A 300A CB, MAIN DISCONNECT. SOCKET SHALL BE PER UTILITY REQUIREMENTS GROUND PER GROUNDING AND BONDING DETAIL 1 1 1 2 L KEY NOTES:# 1. CONFIRM ALL REQUIREMENTS WITH LOCAL ELECTRICAL UTILITY FOR TRANSFORMER PADS, CONDUITS, & LOCATIONS PRIOR TO WORK STARTING. 2. CONCRETE PAD BY EC PER UTILITY C.O. STANDARDS. PAD SHALL BE SET ON PROPERLY PREPARED SURFACE TO PREVENT SKEWING OR SETTLING OF TRANSFORMER ONCE SET N G BOND NEUTRAL TO GND AT THIS LOCATION ONLY INCOMING SERVICE NEUTRAL AND EQUIPMENT GROUND CONDUCTORS #6 CU 1/0 CU METAL UG GAS SERVICE (WHERE APPLICABLE) METAL UG WATER SERVICE BUILDING STEEL IN CONTACT WITH EARTH (10' MIN) OR WHERE STEEL COLUMN BOLTS ARE CONNECTED TO UFER ELECTRODE (WHERE APPLICABLE) UFER GND GROUNDING CONDUCTOR: TIE TO A MIN. 20FT, #5A36 ROD OR 20-FT #4 BARE CU CONDUCTOR. JOIN BY EXOTHERMIC WELDING PROCESS. LOCATE BELOW SERVICE ENTRANCE MAIN DISCONNECT. WIRE TIE TO STRUCTURAL REBAR IN FOOTING. FLOOR SLAB FOUNDATION WALL FOOTING REBAR (TYP) PROVIDE CU THWN BONDING CONDUCTOR IN NON-MAGNETIC RACEWAY. SIZE PER TABLE: LENGTH OF RUN AWG LESS THAN 25' 25' TO 50' MORE THAN 50' #3 #1/0 #3/0 10' GND RODS MAIN DISCONNECT STORAGE RM 113 BACKBOARD TO GROUNDING BUS IN MAIN DISCONNECT (SEE GROUNDING DETAIL) COPPER GROUNDING BUS NOTE: MOUNT TO TTB AT +24" AFF 0.25" 4" 12" ROOM CONTROLLER LMRC-102 NEUTRAL WHT HOT BLK 120/277 LIGHTING LOAD (a) LIGHTING LOAD (b) LMDC-100 OCCUPANCY SENSOR AS NEEDED DLM WALL SWITCH LMSW-102 RJ45 (TYP) LMRJ SERIES PRE-TERMINATED CABLES. ™SEQUENCE OF OPERATION: DEVICES ARE PRESET FOR PLUG n' GO OPERATION ALL ROOMS ARE STAND ALONE. NUMBER OF ZONES ("a" "b" ETC) INDICATED NUMBER OF RELAYS REQUIRED IN A ROOM SWITCH: $LV# - # INDICATES NUMBER OF BUTTONS $LVD# - # INDICATES NUMBER OF BUTTONS STORAGE, DME, ANY NON DIMMED SPACE: • THE ROOM CONTROLLER DEFAULTS TO MANUAL ON. A SWITCH BUTTON PUSH TO THE LOCAL SWITCH IN THE SPACE IS REQUIRED TO TURN LIGHTS ON. • LIGHTS LOADS TURN OFF AUTOMATICALLY VIA OCCUPANCY SENSORS IN SPACE ONCE TIME OUT HAS LAPSED OR A MANUAL PUSH OF LOCAL SWITCH BUTTON IN THE SPACE. HALLWAYS, ENTRY, LOBBY: • THE ROOM CONTROLLER DEFAULTS TO AUTOMATIC-ON/AUTOMATIC OFF. LOADS TURN ON AUTOMATICALLY VIA OCCUPANCY SENSORS IN ROOM. • LIGHTS TURN OFF AUTOMATICALLY VIA OCCUPANCY SENSORS IN SPACE ONCE TIME OUT HAS LAPSED OR A MANUAL PUSH OF LOCAL SWITCH BUTTON IN THE SPACE. NOTE: FOR AREAS WITH ONLY (1) ZONE, PROVIDE A LMRC-101 FOR CONTROL OF THE SINGLE LOAD. ALL EMERGENCY FIXTURES REQUIRE AN UNSWITCHED HOT LEG. FOR RESTROOMS WITH THIS CONFIGURATION, UTILIZE THE SECOND CONTACT FOR EXHAUST FAN. Red NEUTRAL WHT Yel Blu VioGryVio Gry Vio Gry VioGry VioGryVioGryCLASS 2 0-10 VOLT CONTROL WIRING 0-10VDC DIMMING BALLAST REQUIRED. RJ45 PORT (TYPICAL) LMRJ SERIES PRE-TERMINATED CABLES OR CAT5E. FREE TOPOLOGY & SPLITTER ACCEPTABLE UNSWITCHED HOT BLK 120/277 LMRC-213 TRIPLE RELAY ON/OFF/0-10V DIMMING ROOM CONTROLLER LMDM-101 DIGITAL DIMMING SWITCH AS NEEDED RJ45 (TYP.) LMRJ-C8 COUPLERLMDC-100 OCCUPANCY SENSOR LMLS-400 PHOTOSENSOR AS NEEDED LIGHTING LOAD (a) LIGHTING LOAD (b) LIGHTING LOAD (c) LMDC-100 OCCUPANCY SENSOR AS NEEDED SEQUENCE OF OPERATION: DEVICES ARE PRESET FOR PLUG n' GO OPERATION. ALL ROOMS ARE STAND ALONE. NUMBER OF ZONES ("a" "b" ETC) INDICATED NUMBER OF RELAYS REQUIRED IN A ROOM. DETAIL REPRESENTS THE LARGEST RELAY PACK AVAILABLE IN SIZE. SEE PLANS FOR DESIGNED QUANITY RELAY PACK AND WIRE PER MANUFACTURERS WRITEN INSTRUCTIONS. SWITCH: $LV# - # INDICATES NUMBER OF BUTTONS $LVD# - # INDICATES NUMBER OF BUTTONS OFFICE, BEREAVEMENT, BREAK, CONFERENCE: • THE ROOM CONTROLLER DEFAULTS TO MANUAL ON VIA LOCAL WALL SWITCH IN SPACE. PUSHING OF BUTTION, WHEN FIXTURES ARE IN THE OFF POSTION WILL TURN ON LIGHTS TO LAST LIGHTING LEVEL. • A QUICK PUSH OF SWITCH BUTTON, WHEN LIGHTS ARE ALREADY ON IN THE UP DIRECTION WILL RAMP LIGHTS UP TO 100% OUTPUT WHILE PUSHING AND HOLDING OF DIMMING BUTTON UP WILL ALLOW FOR LIGHTING OUTPUT TO INCREASE GRADUALLY UNTIL BUTTON IS RELEASED. A QUICK PUSH OF DIMMING BUTTON DOWN WILL RAMP LOADS OFF OR PUSH AND HOLD WILL RAMP LIGHTING LEVEL DOWN TO LOWEST DIMMING SETTING POSSIBLE OF LIGHT FIXTURE PRIOR TO OFF. • LOADS TURN OFF AUTOMATICALLY VIA OCCUPANCY SENSOR OR IF A QUICK BUTTON PUSH IS PERFORMED. ™ 120/277V LCP WATTSTOPPER # LMCP8-10V 115/277 8HDR 115, OAE LCP1 PROGRAMMABLE ASTRONOMICAL TIME CLOCK A1-9 BUILDING SOFFIT E10 & BUILDING WALL E3E BUILDING WALL E1 SITE POLES E20 & E21 SPARE ALL FIXTURES, EXCEPT E1 SHALL HAVE 0-10V DIMMING CONTROL CONDUCTORS ROUTED TO THEM ALONG WITH RELAY SWITCHED POWER.LOW VOLTAGE SWITCH INPUT (TYP) SPARE SPARE 120/277V 120/277V 120/277V 120/277V 120/277V 120/277V 120/277V 120/277V EXTERIOR PHOTOCELL MOUNTED ON ROOF #LMPT-200 SPARE SPARE A1-9 A1-11 SPARE SPARE SPARE SPARE P REXTERIOR PHOTOCELL INTERFACE IN THE BUILDING #LMIO-301 NOTE: PROVIDE A HAND HELD PROGRAMING TOOL AS PART OF LCP PACKAGE #LMCT-100-2 TO ALLOW FOR INITIAL PROGRAMING AND FUTURE CHANGES BY OWNER. 1. INITIAL START UP PROGRAMMING FOR LIGHTING CONTROL SYSTEM SHALL BE AS FOLLOWS: a. ALL NETWORK STYLE RELAYS SHALL ACT AS INDEPENDENT GROUPS. PROGRAMMING SHALL OPERATE IN CONFIGURATION LISTED BELOW AND IN THE LIGHTING CONTROL SYSTEM SCHEDULE. RELAYS HAVE 0-10V DIMMING BOARDS/ CAPABILITY ASSOCIATED WITH THEM. b. BUILDING EXTERIOR WALL FIXTURES, TYPE E1 SHALL BE PROGRAMMED FOR ON WITH ASTRONOMICAL TIME CLOCK AT 15 MINUTES BEFORE DUSK AND OFF AT 1 HOUR AFTER BUSINESS CLOSE VIA ASTRONOMICAL TIME CLOCK. FIXTURES SHALL REMAIN OFF UNTIL NEXT TIME CLOCK ON CYCLE AT DUSK, UNLESS REQUIRED TO TURN ON BY OWNER PRIOR TO BUSINESS OPENING. TURN ON SHALL BE A MAXIMUM OF 1 HOUR BEFORE OPENING AND ONLY IF PRIOR TO DAWN LEADING UP TO 15 MINUETS AFTER DAWN, WHEN FIXTURES SHALL BE SHUT OFF VIA THE ASTRONOMICAL TIME CLOCK. c. BUILDING EXTERIOR WALL FIXTURE (E3E) AND CANOPY FIXTURES (E10) SHALL BE PROGRAMMED FOR ON WITH ASTRONOMICAL TIME CLOCK AT 15 MINUTES BEFORE DUSK, DIMMING TO 50% OUTPUT AT MIDNIGHT. FIXTURES SHALL REMAIN AT 50% OUTPUT UNTIL 15 MINUTES AFTER DAWN, WHEN THEY SHALL BE SHUT OFF VIA THE ASTRONOMICAL TIME CLOCK. d. ALL SITE LIGHTING/ PARKING LOT FIXTURES SHALL BE PROGRAMMED FOR ON WITH ASTRONOMICAL TIME CLOCK AT 15 MINUTES BEFORE DUSK, DIMMING TO 50% OUTPUT AT MIDNIGHT. FIXTURES SHALL REMAIN AT 50% OUTPUT UNTIL 15 MINUTES AFTER DAWN, WHEN THEY SHALL BE SHUT OFF VIA THE ASTRONOMICAL TIME CLOCK. e. LIGHTING CONTROL PANEL SHALL ALSO ACCEPT PHOTOCELL INPUT, WHICH SHALL OPERATE THE EXTERIOR LIGHTING BETWEEN TIME CLOCK CYCLES WHEN CONDITIONS REQUIRE. SHOULD NATURAL LIGHTING BE REDUCED TO 5 FC AND TIME CLOCK CYCLE NOT BE ACTIVE THE PHOTOCELL SHALL TURN ON LIGHT FIXTURES. LIGHT FIXTURES SHALL TURN BACK OFF AT 10 FC WITH A 5 MINUTE DELAY TO ACCOMMODATE FOR CLOUD COVER. 2.PROGRAMMING LISTED FOR THE LCP SHALL SERVE AS START UP BASE PROGRAMMING. THE ELECTRICAL CONTRACTOR MUST COORDINATE WITH THE OWNER FOR FINAL DESIRED LIGHT CYCLE TIMES AND ANY OTHER MODIFICATIONS TO ACCOMMODATE END USER'S FUNCTION. 3.EC SHALL PROGRAM THE PANEL OR ENLIST THE SERVICES OF FACTORY TRAINED PERSONNEL TO PROGRAM THE LIGHTING CONTROL PANEL PER BASIC START UP LIST, AS WELL AS INCORPORATING ALL OWNER REQUESTS. PROGRAMMING TIME SHALL BE ALLOTTED FOR A MINIMUM OF 1 DAY TO ALLOW FOR PROGRAMMING, DIAGNOSTIC AND OWNER TRAINING ON THE SYSTEM. OWNER TRAINING SHALL BE COORDINATED WITH THE OWNER FOR DATE, TIME AND OUTLINE OF SUBJECTS COVERED PRIOR TO INITIAL BASE PROGRAMMING OF THE PANEL. THE TRAINING SHALL CONSIST OF AT LEAST 2 HOURS OF HANDS ON DEMONSTRATION. SUBJECTS COVERS AT A MINIMUM SHALL CONSIST OF: PANEL BASIC PROGRAMING (CYCLE TIME CHANGES), PANEL FUNCTIONS AND DEMONSTRATION OF END POINT LOADS CONTROLLED. 4.EC SHALL PROVIDE (2) FOLLOW UP SITE VISITS THAT CONSIST OF (2) HOURS EACH AT 6 MONTHS AND 12 MONTHS AFTER SYSTEM START UP TO ADJUST SETTINGS PER OWNERS REQUEST. LCP START UP PROGRAMING WAO 1" EMT CONDUIT IN WALL CAVITY, RUN TO NEAREST ACCESSIBLE CEILING SPACE ACCESSIBLE CEILINGCONDUIT BUSHING 315 North 25th Street, Suite 102 Billings, MT 59101 Phone: 406.656.6000 Project # 6804.001 COPYRIGHT © 2021 THESE DOCUMENTS, IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT; ARE THE SOLE PROPERTY OF STUDIO 4 ARCHITECTS. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON THE SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION, OR ADAPTATION WITHOUT THE EXPRESS WRITTEN CONSENT OF STUDIO 4 ARCHITECTS IS STRICTLY PROHIBITED. project: set: dates: sheet: PRE: CRS: CDS: REV: REV: PROJECT NO. DRAWN BY: CHECKED BY: 2-22-21 - - - 27 Shiloh Road Suite 8 Billings, MT 59106 ph: 406.656.1714 fx: 406.656.1715 web: studio4architects.com STUDIO ARCHITECTS 8-6-21 e0.2PRELIMINARY -NOT FOR CONSTRUCTIONTJ JK 2104Stillwater HospiceEvergreen DriveDETAILSBozeman, MtN.T.S.1 ONE LINE DIAGRAM N.T.S.2 GROUNDING AND BONDING RISER DIAGRAM N.T.S.3 GROUNDING BUS BAR DETAIL FEEDER NUMBER KEY: A = ALUMINUM CONDUCTORS N = INCLUDES NEUTRAL CONDUCTOR S = SINGLE PHASE NOTE: GROUNDING CONDUCTOR IS SIZED ACCORDING TO NEC 250.122 TABLE, UNLESS FEEDER NUMBER IS FOLLOWED BY AN ASTERISK (*) INDICATING THAT THE GROUNDING CONDUCTOR IS SIZED ACCORDING TO NEC 250.66 TABLE. SCHEDULE IS BASED ON 75 DEGREE COPPER CONDUCTORS IN NEC 310.60 TABLE. FEEDER SCHEDULE - COPPER FEEDER NUMBER AMPERAGE SETS IN PARALLEL CONDUIT SIZE PHASE WIRE QTY PHASE AWG NEUTRAL QTY NEUTRAL AWG GROUND AWG 4NS* 400 A 2 2"C 2 #3/0 1 #3/0 #2 N.T.S.4 LIGHTING CONTROL DIAGRAM -SINGLE OCCUPANCY N.T.S.6 LIGHTING CONTROL DIAGRAM -MULTIPLE OCCUPANCY N.T.S.7 EXTERIOR LIGHTING CONTROL DIAGRAM -LCP N.T.S.5 WORK AREA OUTLET -ROUGH-IN