Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E0.1ElectricalCover&Notes
X OS OS R1 R2 R3 R4 LVD LV PNL A208Y/120V 3ø, 4W M M SPD L X XX XTVXD-1 X J AP ELECTRICAL ABBREVIATIONS LEGEND A, AMP AMPERES AC ABOVE COUNTER A/C AIR CONDITIONING AF AMP FUSE AFC AVAILABLE FAULT CURRENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AL ALUMINUM AS AMP SWITCH ATS AUTOMATIC TRANSFER SWITCH BAS BUILDING AUTOMATION SYSTEM BKR BREAKER BOF BOTTOM OF FIXTURE C RACEWAY/CONDUIT CB CIRCUIT BREAKER CCT COLOR RENDERING TEMPERATURE CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING C.O.RACEWAY/CONDUIT ONLY, WITH PULL STRING COD CENTER OF DEVICE CNTRL CONTROL CU COPPER (D)EXISTING TO BE DEMOLISHED DISC DISCONNECT DIST DISTRIBUTION DPDT DOUBLE POLE DOUBLE THROW DWG DRAWING EA EACH EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ELEC ELECTRIC EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT EX, EXIST EXISTING FA FIRE ALARM FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FD FUSED DISCONNECT FLR FLOOR FO FIBER OPTIC FSD FIRE SMOKE DAMPER RELAY, CONTROLLED BY ASSOCIATED SMOKE DETECTOR AND CIRCUITED BACK TO FACP FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING GEC GROUNDED ELECTRODE CONDUCTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER GFP GROUND FAULT PROTECTION GND GROUND GRC GALVANIZED RIGID CONDUIT HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSEPOWER HPS HIGH PRESSURE SODIUM HTR HEATER HVAC HEATING, VENTILATION & AIR CONDITIONING HZ HERTZ J-BOX JUNCTION BOX KVA KILOVOLT-AMPERES KW KILOWATTS LCP LIGHTING CONTROL PANEL LPW LUMENS PER WATT LTG LIGHTING LM LUMENS LV LOW VOLTAGE MAG MAGNETIC STARTER MAN MANUAL MAX MAXIMUM MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING MH METAL HALIDE MIN MINIMUM MSS MOTOR STARTER SWITCH WITH THERMAL OVERLOADS N NEUTRAL NC NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFD NON-FUSED DISCONNECT NIC NOT IN CONTRACT NO NORMALLY OPEN #NUMBER OAE OR APPROVED EQUAL OC ON CENTER OCPD OVERCURRENT PROTECTIVE DEVICE OH OVERHEAD P POLE PB PUSHBUTTON PC PLUMBING CONTRACTOR PH PHASE PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT PWR POWER (R)EXISTING TO REMAIN RCPT RECEPTACLE RECEPT RECEPTACLE RGS RIGID GALVANIZED STEEL RM ROOM RVNR REDUCED VOLTAGE NON-REVERSING RVR REDUCED VOLTAGE REVERSING SP SINGLE POLE TOGGLE SWITCH SPD SURGE PROTECTIVE DEVICE (TVSS) SPEC SPECIFICATION SPST SINGLE POLE SINGLE THROW SSPB START-STOP PUSHBUTTON SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TB TELEPHONE BOARD TC TIME CLOCK TD TIME DELAY TEL TELEPHONE TR TAMPER RESISTANT TSP TWISTED SHIELDED PAIR TTB TELEPHONE TERMINAL BOARD TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERES VFD VARIABLE FREQUENCY DRIVE W WATTS WGO WORK AREA OUTLET WP WEATHERPROOF W/O WITHOUT XFMR TRANSFORMER Y WYE-CONNECTED Δ DELTA-CONNECTED ø PHASE ELECTRICAL LIGHTING FIXTURE LEGEND RECESSED LED FIXTURE - "a" & "b" DESIGNATES SWITCH EXIT SIGN - WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. RECESSED EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE WALL MOUNT LED FIXTURE LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG EMERGENCY LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG POLE MOUNTED FIXTURE DUAL HEAD EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR CEILING MOUNT WALL MOUNTED SCONCE SURFACE DOWNLIGHT SURFACE EMERGENCY DOWNLIGHT RECESSED CAN DOWNLIGHT RECESSED CAN EMERGENCY DOWNLIGHT RECESSED CAN WALL WASHER TRACK LIGHTING. SEE FIXTURE SCHEDULE AND LIGHTING PLANS. COMBINATION EXIT SIGN/ EGRESS LIGHTING UNIT - WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE ELECTRICAL LIGHTING CONTROL LEGEND TOGGLE SWITCH (MOUNT AT +48", UNO) "X" INDICATES TYPE: BLANK - SINGLE POLE 3 - INDICATES THREE-WAY 4 - INDICATES FOUR-WAY D - INDICATES DIMMER SWITCH PHILIPS SUNRISE - ON/OFF K - INDICATES KEYED SWITCH T - INDICATES TIMER P - INDICATES PILOT LIGHT ILLUMINTED HANDLE LEVITON #1221-PLC, OR EQUAL. OS - INDICATES WALL SWITCH OCC SENSOR WATTSTOPPER DW100 (SINGLE OR DUAL DW-200 SWITCH) OSD - INDICATES WALL SWITCH OCC SENSOR WITH 0-10V DIMMING - WATTSTOPPER PW-311 a - INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE a b - INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE b ab - INDICATES LIGHTING SWITCHES WITH MULTIPLE ZONES OCCUPANCY SENSOR - DUAL TECHNOLOGY CEILING MOUNT: WATTSTOPPER LMDC-100, OR EQUAL WALL MOUNT: WATTSTOPPER LMDX-100, OR EQUAL WALL MOUNT AT +96", UNO STANDARD LIGHTING CONTROLS: SWITCHES AND LINE VOLTAGE DIMMERS DIGITAL LIGHTING CONTROLS: ROOM CONTROLLERS AND LOW VOLTAGE DEVICES ON/OFF ROOM CONTROLLER WITH (1) RELAY WATTSTOPPER DLM LMRC-101, OR EQUAL ON/OFF/0-10V ROOM CONTROLLER WITH (1) RELAY WATTSTOPPER DLM LMRC-211, OR EQUAL ON/OFF/0-10V ROOM CONTROLLER WITH (2) RELAYS WATTSTOPPER DLM LMRC-212, OR EQUAL ON/OFF/0-10V ROOM CONTROLLER WITH (3) RELAYS WATTSTOPPER DLM LMRC-213, OR EQUAL LOW VOLTAGE DIMMING SWITCH WATTSTOPPER DLM LMDM-101, OR EQUAL LOW VOLTAGE SWITCH, # INDICATES NUMBER OF BUTTONS. NO "#" IS A 2 BUTTON SWITCH. WATTSTOPPER DLM LMSW-10#, OR EQUAL ELECTRICAL ONE-LINE LEGEND FIXED MOUNT LV BREAKER FUSED SWITCH ("XXAS/XXAF" - SW AND FUSE AMP RATING) DISCONNECT SWITCH ("XXAS" = SWITCH AMP RATING) FUSED DISCONNECT SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING) COMBINATION MOTOR STARTER (STR SIZE, TYP, AS, AF, SEE MEP COORDINATION SCHEDULE) SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, PHASE, NUMBER OF WIRES WHEN INDICATED MOTOR UTILITY ELECTRIC METER AND BASE (BASE BY CUSTOMER) SURGE PROTECTION DEVICE LIGHTNING ARRESTER, TYPE 1 SPD, MOUNTED ON EXTERIOR OF MAIN SWITCHGEAR (SQUARE D NO. SDSA3650, OAE) EQUIPMENT TOGGLE DISCONNECT SWITCH "X" INDICATES TYPE: F - FUSTAT M - MOTOR STARTER SWITCH W/ THERMAL OVERLOADS ELECTRICAL POWER LEGEND PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TO EACH DEVICE (PANEL NAME - CIRCUIT NUMBER). BRANCH CIRCUIT WIRE SIZE IS #12, UNO. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENT CIRCUITING, SEE MEP COORDINATION SCHEDULE. "X" INDICATES TYPE: GFI - GROUND FAULT INTERRUPTER WP - WEATHERPROOF WHILE-IN-USE COVER U - PROVIDE WITH (2) USB PORTS TR - TAMPER RESISTANT PANELBOARD OR LOAD CENTER FLATSCREEN TV BOX: 3-GANG, FLUSH IN WALL, PASS & SEYMOUR TV3WMTVSSW. DUPLEX RECEPTACLE & 2-SINGLE GANG DATA/ LOW VOLTAGE OPENINGS. PROVIDE BLANK COVERS FOR LOW VOLTAGE OPENINGS AND ROUTE AN 1-1 1/4" EMPTY C. TO CENTER OPENING AND 1-1" EMPTY C. TO SIDE OPENING. CONDUITS START AT THE TOP OF GANG OPENING IN WALL AND ROUTE INTO ACCESSIBLE CEILING SPACE. MOUNT BOX AT +72", UNO SIMPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) DUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) QUADRUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) FLOOR BOX WITH QUADRUPLEX RECEPTACLE - WITH (2) COMM PORTS, OR WITHOUT COMM AS SHOWN. FURNISH 1 1/4" DEDICATED CONDUITS FROM EACH DATA COMPARTMENT AS WELL AS 3/4" POWER CONDUIT FROM BOX. ROUTE DATA CONDUITS, COMPLETE WITH PULL STRINGS OVER TO AND UP WALL INTO ACCESSIBLE CEILING SPACE, UNO. INCLUDE ALL HARDWARE/ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. PROVIDE COVER (COORDINATE WITH ARCHITECT FOR FLOORING TYPE AND FINISH). SPECIAL PURPOSE RECEPTACLE (MOUNT AT +18", UNO) "X" INDICATES TYPE: A - NEMA 5-20R, #12 CU; B - NEMA 5-30R, #10 CU; C - NEMA 5-50R, #8 CU; D - NEMA 6-20R, #12 CU; E - NEMA 6-30R, #10 CU; F - NEMA 6-50R, #8 CU; G - NEMA 14-20R, #12 CU; H - NEMA 14-30R, #10 CU; I - NEMA 14-50R, #8 CU PUSHBUTTON (MOUNT AT +48", UNO) "X" INDICATES TYPE: EPO - EMERGENCY POWER OFF ADA - HANDICAPPED ACCESSIBLE DOOR (DEVICE BY OTHERS) ODO - OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS) "X" INDICATES TYPE: A - 4-GANG FLOOR BOX, CORROSION RESISTANT COATING FOR CONCRETE FLOORS (3" MIN. POUR DEPTH), UP TO 2" CONDUIT FEED (HUBBELL NO. CFB4G30CR, OAE) ABOVE COUNTER RECEPTACLE - MOUNT AT +4" ABOVE BACKSPLASH RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN FINISHED SPACES, EXPOSED IN UNFINISHED SPACES GROUNDING BUS RACEWAY BELOW FLOOR OR BELOW GRADE JUNCTION BOX ELECTRICAL LOW VOLTAGE LEGEND TELEPHONE/DATA SYSTEM TELEPHONE OUTLET (MOUNT AT +18", UNO). SEE NOTE. VOICE-DATA OUTLET (MOUNT AT +18", UNO). SEE NOTE. DATA OUTLET (MOUNT AT +18", UNO). SEE NOTE. WIRELESS ACCESS POINT NOTE: PROVIDE ROUGH-IN ONLY. 4-SQUARE BOX WITH MUD RING & 1" C. STUBBED UP TO ACCESSIBLE CEILING SPACE. ELECTRICAL PROJECT GENERAL NOTES A. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID. B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OF WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET. C. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE AT WWW.NECANET.ORG. D. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS. E. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE- RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES. F. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED FOR AT LEAST 75 DEGREES C. G. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES SHALL BE AS FOLLOWS: #10 AWG CU FOR RUNS BETWEEN 100 AND 200 LINEAR FEET, #8 AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, AND AS CALCULATED BY THE CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS REQUIRED. H. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT. ABBREVIATIONS AND SYMBOLS GENERAL NOTES A. THE ABBREVIATIONS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT. B. THE SYMBOLS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT. C. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS, MAKING ADJUSTMENTS AS REQUIRED TO AVOID INTERFERENCE WITH EQUIPMENT SUCH AS BASEBOARD FIN-TUBE, CABINET UNIT HEATERS, ETC. ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ALL SUCH HEIGHT ADJUSTMENTS. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED. 315 North 25th Street, Suite 102 Billings, MT 59101 Phone: 406.656.6000 Project # 6804.001 COPYRIGHT © 2021 THESE DOCUMENTS, IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT; ARE THE SOLE PROPERTY OF STUDIO 4 ARCHITECTS. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON THE SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION, OR ADAPTATION WITHOUT THE EXPRESS WRITTEN CONSENT OF STUDIO 4 ARCHITECTS IS STRICTLY PROHIBITED. project: set: dates: sheet: PRE: CRS: CDS: REV: REV: PROJECT NO. DRAWN BY: CHECKED BY: 2-22-21 - - - 27 Shiloh Road Suite 8 Billings, MT 59106 ph: 406.656.1714 fx: 406.656.1715 web: studio4architects.com STUDIO ARCHITECTS 8-6-21 e0.1PRELIMINARY -NOT FOR CONSTRUCTIONTJ JK 2104Stillwater HospiceEvergreen DriveTITLEBozeman, MtELECTRICAL SHEET INDEX NUMBER SHEET NAME ELECTRICAL SHEET INDEX NUMBER SHEET NAME e0.1 ELECTRICAL COVER e0.2 ELECTRICAL ONE-LINE AND DETAILS e0.3 ELECTRICAL SCHEDULES e0.4 ELECTRICAL SPECIFICATIONS e0.5 ELECTRICAL SPECIFICATIONS e2.1 ELECTRICAL LIGHTING PLAN - 1ST FLOOR e3.1 ELECTRICAL POWER & SYSTEMS PLAN - 1ST FLOOR e3.2 ELECTRICAL PLAN - 2ND FLOOR e4.1 ELECTRICAL SITE PLAN