HomeMy WebLinkAboutC1.2DesignPlan o
LOT 1
LOT SA EVERGREEN
BUSINESS
PARK /
3
EX. ELECTRICAL JUNCTION BOX /
FXgjL
EX. PRIVATE EX. 18" CMP CULVERTDRIVE APPROACH INV. N = 4729.07INV. OUT = 4728.54
w w�H w w w EVERGREEN PROPOSED WATER /
w�w PROPOSED SANITARY III SERVICE STREET VISION h
ANTICIPATED PB LOCATFMOF w-w- SEWER SERVICE GILKERSON DRIVE - - QEaSED UNDERGROUND POWER w TRIANGLE (TYP.)
- PROPOSED FENCING. 1" CURB STOP�SEE DEPARTURE
s s 3 PROP. 5-FT PROPOSED 15" EXHIBIT FOR ADDITIONAL INFORMATION w
s s s�-�-s PROPOSED RCP CULVERT III w 26.0% PROPOSED 15" RCP CULVERT
s PROPOSED 3.2'
BIKE RACK. s s s-LANDSCAPE BUFFER
PROPOSED RED. SEE 4/C22 .
. s s s �s 15.01, /
RAMP. SEE 7/C2.1 •!~ / 26.0' III 3-12" DUAL WALL HDPE \\\\
r✓� _ / I ¢ UTILITY CONDUITS
\M
-WIDE SIDEWALK 10' BLOCK FRONTAGE I107.0' PARKING. '-�J AS OUMEDR ROW
£h9 I400'3 •` w SETBACK 1 O -10.0 / SLOT FRONTAGE- v / NEWE10.0' UTILITY
PROPOSED 5-FTa --
WIDE SIDEWALK. I u --- - _ s
3 E-- - J JU JU J U JU JU -cam- - I- -- - (,
/ • '5.0' I� I .•' CONC. STEP SEE PROPOSED 0----{ -- -- Ju --_9.0' _ u Ju Ju Ju SEE 6 C2.1 , Ju _ ---- _-
JJU
I 8.0' 18.0' � - - -----
PED. RAMP. 10 � --- --- ---
> 1` / 18. E EIr /
PROPOSED 4" SDR 26 PVC SEWER 20 FRONT PROPOSED PROPOSSNOW ED /
SERVICE @ 2% MIN. GRADE. SEE 1/C2.3 a LOT ZONING SETBACK 9.0' LIGHT POLE PROPOSED --- STORAGE /
III
LIGHT POLE
VAN ACCESSIBLE NEW 10' UTILITY PARKING SIGN. g p' / LOT 3A 26 0, I �; 5' LANDSCAPE
CONNECT TO EX, 4" SEWER EASEMENT SEE 3/C22. °, 0.99ACRES .�� �-
SERVICE. INV - 4723.58. VERIFY I ;` y SCREENING /
LOT 13& 14 PRIOR TO CONSTRUCTION. �,. PROPOSED 7-FT
PROPOSED 7.0' WIDE SIDEWALK
III IIIZF I BUILDING °Y /
PROP. 500 GAL SAND OIL SEPARATOR. SEE 1/C2.5
I PROPOSED CLEAN OUTS ',V � 26.0 .PROPOSED DUMPSTER ENCLOSURE
1p SEE ARCHITECTURAL DETAIL 5/A5.2
�: p SEE 4/C2.3 .' PROP. RED.
PROPOSED ELECTRICAL RAMP SEE ` '• / /
EX. PRIVATE TRANSFORMER & 7'X7' PAD O I PROPOSED ELECTRIC METER 7/C2.1
LOCATION PRIOR TO CONSTRUCTION VE PPSAW CCU T, REMOVE, AND w PROPOSED LIGHT POLE';` ��'''•'•"' Y' :.'t":, •~" w�7.�'r6 ••'9�• •"',� // /%/
APPROXIMATE LOCATION OF EXISTING J" WATER SERVICE. VERIFY
PROPOSED GAS METER WALK /
REPLACE EXISTING ASPHALT AND CURB & GUTTER. REMOVE 44.9'r ' •;• PROPOSED SIDEWALK PROPOSED 7-FT
SERVICE LINE AND CAP AT THE EXISTING MAIN. I 16.a •CtE;I';+►; r PROPOSED CLEAN OUT '•-16.0. o (CHASE. SEE 4/C2.4 r / WIDE SIDEWALK
IIr I I I I ♦ •I'st'. ��'•' SEE 4/C2.3 • . ° PROPOSED PE/D. RAMP. SEE 3/C2.1.
TAP EXISTING WATER MAIN. SEE NOTES 6
& 7 ON CO.2 AND DETAILS 2 & 3/C2.3. _ / EXCAVATE TO NATIVE GRAVEL. FILL / / VAN ACCESSIBLE PARKING SIGN. SEE 3/C2.2.
TO POND BOTTOM WITH COBBLES. o'i / PROPOSED 2.25-FT WIDE CONC. CHANNEL
\PROPOSED / SEE 1/C2.2
PROPOSED 1" COPPER TYPE K DOMESTIC SERVICE. _ / i PROJECT SITE:
��� 3' SIDE AND REAR PROP. 8" SDR 35 PVC OR- ,� DETENTION POND / / /
A-2000 PVC STORM DRAIN. \ / e r LOT 3A OF AMENDED McCHESNEY INDUSTRIAL PARK SUBDIVISION
3-12" DUAL WALL LOT ZONING SETBACK \� a I 2 // / /'// LOCATED IN THE NORTHEAST ONE-QUARTER OF SECTION 1, TOWNSHIP 2 SOUTH,
MAINTAIN 1%MIN. GRADE. \ 8.53' OF 12" STORM DRAIN AAAfff
HOPE UTILITY CONDUITS �r •�� START INV.: 4728.50 RANGE 5 EAST, PRINCIPAL MERIDIAN MONTANA, CITY OF BOZEMAN, GALLATIN COUNTY,
APPROX. LOCATION OF INSTALL FETS / / STOCKPILE AND STAKING MONTANA
1" CURB STOP �' -PROPOSED IRRIGATION WELL �,�. ¢ / LOCATION (APPROXIMATE)
SITE SUMMARY:
3 /r PROPOSED _ / / SITE AREA (GROSS): 0.99 ACRES (43,262 SF)
I PROPOSED 3-FT SNOW \\�36" STORM OUTLET STRUCTURE // / 30.0' WIDE UTILITY& APPROX. AREA OF BUILDINGS: 5,180 SF (12.0%)
WIDE DROP CURB STORAGE SEE 3/C2.4 ¢�EX. OVERHEAD i DRAINAGE EASEMENT APPROX. AREA OF PAVING: 12,880 SF (29.8%)
`EX. DITCH�AND GONG. APRON. RIM: 4731.13 �`/ POWER TO BE APPROX AREA OF SIDEWALKS:1,883 SF (4.3%)
y I / SEE 2/C2.2. SUMP:4727.71 RELOCATED LANDSCAPING (-REMAINING):23,319 SF (53.9%)
2.77' OF 12" STORM DRAIN INV IN:4728.46 12" /
--dN�UR INLET d / �� \\\\ BUILDING SUMMARY:
Ho END INV.: 4728.97 INV OUT:4729.00 12" /
EX. CURB INLET d INSTALL FETS o / TOTAL GROSS BLDG: 5,180 SF
dHo�dHo / ��� / GARAGE: 1,352 SF
�dHo ��`� CORRIDOR: 712 SF
E_ __-��---______ _- - _ ,/
RESTROOM/BREAK: 331 SF _
NET/OFFICE FLOOR AREA: 2,785 SF
EX. 48' CMP CULVERT/ dHo� _
INV. IN = 4723.51 °- ZONING DISTRICT: M-2
dHo INV. OUT = 4723.18 / _
nq / STRUCTURE SETBACKS:
LOT 15 / / FRONT SETBACK: 20-FT °
A� LOT 2A SIDE AND REAR SETBACK: 3-FT d
y / BLOCK FRONTAGE SETBACK: 10-FT
/ // BLOCK FRONTAGE:
/ b NIKLES DRIVE (COB PUBLIC STREET - LOCAL CLASSIFICATION): OTHER
/ EVERGREEN DRIVE (PRIVATE STREET W/ PUBLIC ACCESS): OTHER
/ REQUIRED PARKING:
REVISIONS: // OFFICE PARKING: 1 SPACE PER 250 SQUARE FEET OF NET FLOOR AREA
1. PHASE 1 WATER SERVICE SHIFTED FURTHER WEST. / NET/OFFICE FLOOR AREA = 2,785 SF
2. CURB STOPS NOW SHOWN AT STANDARD LOCATION OF 8-FT PAST PROPERTY LINE. REQUIRED PARKING: 2,785 SF/250 SF/SPACE = 11 SPACES REQUIRED
3. PARKING LOT CONFIGURATION REVISED TO SHOW ALL PARKING AS PART OF PHASE 1 IMPROVEMENTS. REQUIRED BICYCLE PARKING: 10%: 2 STALLS i
4. ADDITIONAL PEDESTRIAN RAMP SHOWN AT TERMINUS OF THE PROPOSED NIKLES DRIVE SIDEWALK.
5. PROPOSED IRRIGATION WELL NOW SHOWN NORTH OF THE PROPOSED STORM POND. PARKING PROVIDED: i
6. PROPOSED FENCING NOW SHOWN ALONG EAST EDGE OF PARKING LOT. SURFACE PARKING: 26 STALLS (INCLUDING 2 ACCESSIBLE PARKING STALLS) _
7. ADDED DIMENSION LABELS: ALL PARKING TO BE CONSTRUCTED DURING PHASE 1 IMPROVEMENTS
7.1. LENGTH OF PROPOSED DRIVEWAY TO GARAGE BICYCLE PARKING: 5 STALLS
7.2. LENGTH OF PARKING LOT ALONG THE EVERGREEN FRONTAGE si
7.3. WIDTH/DEPTH OF LANDSCAPE BUFFER LOCATED ON SITE
NO. REVISIONS DRAWN BY DATE 0 20 40 60 PROJECT #: 21-076 SKEET
1 AS OUTLINED IN NOTES ABOVE MCG 5/09/2022 STILLWATER HOSPICE 32 DISCOVERY DRIVE DATE: 11/23/2021
BOZEMAN,MT 59718 Civil Engineering }�
DESIGN PLAN g g DESIGN PLAN �Y.�
SCALE (FEET) PHONE(40)582-5-0221 Geotechnical Engineering ALLIED
FAxeden 58&577° Land Surveying EN6�NEER►NR
PROJECT ENGINEER: RSR DRAWN BY: MCG ���Ta �1yT ,rp�T.���T 7a www.alliedengineedng.com sExxnc�,urc. y STILLWATER HOSPICE
DESIGNED BY: RSR, MCG REVIEWED BY: RSR ..LL.. AA�tly ``L�J�11a�1 ll��'t� ° „5ep„1e°"�o DESIGN PLAN