Loading...
HomeMy WebLinkAbout005TripGenerationMemo                                                                                                                                                                                               MEMO 32 Discovery Drive                Bozeman, MT  59718                (406) 582‐0221                 Fax (406) 582‐5770  From: Allied Engineering Services, Inc. Project Name: Nikles Business Park - Site Plan Project Number: AESI 21-076 Date: November 23, 2021 Re: Trip Generation MEMO DETAILS: The subject property is defined as Lot 3A of McChesney Industrial Park Subdivision and is located at the southwest corner of the intersection of Nikles Drive and Evergreen Drive. Trip generation estimates for the proposed commercial development are based on Trip Generation 9th Edition – Institute of Transportation Engineers (ITE). The proposed site improvements will involve construction of office buildings. The site is currently undeveloped. The improvements are anticipated to be completed in two phases. The first office building will be constructed near the intersection of Nikles Drive and Evergreen Drive and is intended to provide office space for Stillwater Hospice. The second structure is set back further in the site and would be planned for permitting and construction upon securing a lease tenant. The gross floor area of the phase 1 building is 5,180 SF. The phase 2 building is currently shown at 3,441 SF. Parking will be provided for both office buildings with a shared parking lot. Access to the site will be from two proposed approaches off Evergreen Drive. An additional approach is planned off Nikles Drive but will only be used for access to an attached garage (part of the phase 1 building). The land use closest to the proposed project is for general office buildings (Section 710 of ITE manual). Table 1 provides a summary of trips generated based on the gross floor area of the proposed offices. Please note that the trip generation values are for the combined gross floor areas of both office buildings (8,621 SF). The ITE manual recommends that the total area of all buildings be used in the trip generation calculations when the buildings are interrelated (defined by shared parking facilities or the ability to easily walk between buildings). According to the ITE manual, the weekday A.M. and P.M. peak hour of the generator typically coincides with the peak hour of the adjacent street traffic. Therefore, only one A.M./P.M. peak hour, which represents both the peak hour of the generator and the peak hour of the adjacent street traffic, is displayed. November 23, 2021 Allied Engineering Services, Inc. Memo Page 2 Table 1 – General Office Building Trip Generation Based on Gross Floor Area Description Method Average Rate Total Trips % Entering % Exiting Trips Entering Trips Exiting Weekday, A.M. Peak Hour Gross Floor Area - per 1000 ft2 (8.621) 1.56 13 88 12 12 2 Weekday, P.M. Peak Hour Gross Floor Area - per 1000 ft2 (8.621) 1.49 13 17 83 2 11 Weekday Gross Floor Area - per 1000 ft2 (8.621) 11.03 95 50 50 48 48