Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
AG401TypicalMountingHeights
30" MAX38" MIN6" MAX 48" MIN 6" MAX 6" MAX38" MIN33" - 36" TO TOP8" -10"12" MAX 60" MIN 24" MAX 24" MIN 33" - 36" TO TOP12" MIN HEAD END GRAB BARS AT TUB WITHOUT PERMANENT SEAT (PUBLIC) ICC A117.1-2009 GRAB BAR REINFORCEMENT AT TUB (TYPE A & TYPE B) ICC A117.1-2009 GRAB BAR REINF AT SHOWER (TYPE A & TYPE B) ICC A117.1-2009 SEAT GRAB BARS SEAT 15" MIN TO RIM17" MAX20" TO RIMT. O. HANDLE48" MAX TOT.O. SEAT17" - 19"18" MINMIN1 1/2"12" MAX 54" MIN 33" - 36" TO TOP39" - 41"18" MIN39" - 41"GRAB BARS & TOILET TISSUE DISPENSER (PUBLIC) ICC A117.1-2009 17" - 19" AMBULATORY 24" MIN*12" MIN REAR GRAB BAR (NOT REQD @ AMBULATORY) SIDEWALL GRAB BARS. PROVIDE ON EACH SIDE OF AMBULATORY STALL STANDARD URINAL (PUBLIC) ICC A117.1-2009 ROLL-IN SHOWER (PUBLIC) ICC A117.1-2009 17" - 19"3" - 6"GRAB BAR FOLDING SHOWER SEAT CONTROL AREA HAND-HELD SHOWER UNIT W/ 59" MIN HOSE 42"60"33" - 36" TO TOP10" MAX 18" MIN2" MAX 46" MIN*9"2' - 5"GRAB BAR REINFORCEMENT & TOILET TISSUE DISPENSER (TYPE A) ICC A117.1-2009 62" MIN30" MIN6" 8" 8" MAX 58" MIIN 3' - 8" MIN2' - 8" MAX8" MAX 50" MIN SWING-UP GRAB BAR REINFORCEMENT (TYPE B) ICC A117.1-2009 2' - 5"9"24" MIN 33" - 36" TO TOP8" - 10"12" MAX15" MAX HEAD END CONTROL END GRAB BARS AT TUB W/ PERMANENT SEAT (PUBLIC) ICC A117.1-2009 HAND-HELD SHOWER UNIT W/ 59" MIN HOSE SEAT GRAB BARS 4" MAX 3" - 6"18" MIN33" - 36" TO TOPBACK WALL 24" MIN 42" MAX 16" - 18" ACCESSIBLE URINALS TO BE 13 1/2" MIN FROM REAR WALL TO FRONT OF URINAL 38" MAX2" MAX 46" MIN*2' - 5"9"8" MAX 58" MIN GRAB BAR REINFORCEMENT & TISSUE DISPENSER (TYPE B) ICC A117.1-2009 HAND-HELD SHOWER UNIT W/ 59" MIN HOSE (TYPE A ONLY)48" MAXT.O SEAT15" - 19"T.O. SEAT15" - 19"T.O. SEAT15" - 19"16" - 18"16" - 18"18" MIN18" MIN31" MAX18" MIN31" MAX18" MIN31" MAX18" MIN 33" MIN 18" MIN 35" MIN 48" MAX38" MINGENERAL NOTES *12" MIN WHERE 24" NOT POSSIBLE ACCESSIBLE URINAL (PUBLIC) ICC A117.1-2009 HANDLE AT OPEN SIDE LAV COUNTER HANDLE AT OPEN SIDE *30" MIN WHERE 46" NOT POSSIBLE LAV COUNTER 48" MIN CLEARANCE 60" MIN CLEARANCE *30" MIN WHERE 46" NOT POSSIBLE HANDLE AT OPEN SIDE CONTROL AREA 24" MIN CONTROL END HAND-HELD SHOWER UNIT W/ 59" MIN HOSE 4" MAX 3" - 6"18" MIN33" - 36" TO TOPCONTROL AREA CONTRO L AREA CONTROL END SIDE WALLCONTROL WALL 15" MAXCONTROL AREA CONTROL WALL HANDLE AT OPEN SIDE 60" MIN CLEARANCE 2' - 5"9"HEAD END 18" MIN 30" MAX38" MINBACK WALL 24" MAX15" MINSEAT WALL FOLDING SHOWER SEAT PLAN (PUBLIC) ICC A117.1-200914" - 15"3' - 0"15" - 16" 22" - 23"2' - 3" MINMIN9"6" MAX MIN 8"1 1/2" MAX2 1/2" MAX 3" MAXDRINKING FOUNTAIN (PUBLIC) ICC A117.1-2009 DRINKING FOUNTAIN (PUBLIC, STANDING) ICC A117.1-2009TO SPOUT3' - 0" MAX15" MIN5" MAX 15" MIN5" MAX TO SPOUT38" -43"MIN9"6" MAX11" MIN MIN 8"2' - 3" MIN2' - 10" MAX17" - 25" INSULATE ALL EXPOSED PIPING LAVATORY (PUBLIC) ICC A117.1-2009 11" MIN MIN9"6" MAX MIN 8"2' - 3" MIN2' - 10" MAX24" MAX INSULATE ALL EXPOSED PIPING KITCHEN SINK (PUBLIC & TYPE A) ICC A117.1-2009 NOTE: CLEARANCE REQUIRED AT ONLY ONE BOWL OF MULTI-BOWL SINK 1. DIMENSIONS ARE COMPLIANT WITH ICC A117.1-2009. 2. NOT ALL FIXTURES AND DEVICES INDICATED MAY BE USED IN THE PROJECT. 3. MOUNTING HEIGHTS INDICATED MAY BE SUPERCEDED BY MORE SPECIFIC INFORMATION ELSEWHERE IN THE DOCUMENTS. 4. "PUBLIC" INDICATES ELEMENTS TO COMPLY IN PUBLIC AREAS. "TYPE A" INDICATES ELEMENTS TO COMPLY IN ACCESIBLE PORTIONS OF TYPE A UNITS. "TYPE B" INDICATES ELEMENTS TO COMPLY IN ACCESSIBLE PORTIONS OF TYPE B UNITS. 5. PROVIDE BLOCKING / REINFORCEMENT FOR ALL ACCESSORIES PER MANUFACTURER'S INSTRUCTIONS. 6. PROVIDE BLOCKING / REINFORCEMENT FOR FUTURE INSTALLATION OF GRAB BARS IN ACCESSIBLE BATHROOMS OF "TYPE A" & "TYPE B" UNITS. 7. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS & SHALL WITHSTAND A VERTICAL OR HORIZONTAL FORCE OF 250 LBS APPLIED TO ANY POINT ON THE GRAB BAR, FASTENEER, MOUNT, OR SUPPORT. 8. SHOWER & BATHTUB SEATS SHALL WITHSTAND A VERTICAL OR HORIZONTAL FORCE OF 250 LBS APPLIED TO ANY POINT ON THE SEAT, FASTENER, MOUNT OR SUPPORT. 9. ALL APPLIANCES & PLUMBING FIXTURES MUST COMPLY WITH APPLICABLE ANSI & ADA REQUIREMENTS. OPERABLE PARTS SHALL: 1) BE 34" -48" AFF.; 2) BE OPERABLE WITH ONE HAND, 3) NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST, AND 4) BE ACTIVATED BY NO MORE THAN 5 LBS OF FORCE. 10. DOOR THRESHOLDS MUST HAVE A MAXIMUM HEIGHT OF 1/2" WITH A 1:2 BEVEL. MAXIMUM REACH DEPTH 0.5 INCH 2 INCHES 5 INCHES 6 INCHES 9 INCHES 11 INCHES (13 MM) (51MM) (125MM) (150 MM) (230MM) (288 MM) MAXIMUM REACH HEIGHT 48 INCHES 46 INCHES 42 INCHES 40 INCHES 36 INCHES 34 INCHES (1220 MM) (1170 MM) (1065 MM) (1015 MM) (915 MM) (865 MM) ICC/ANSI A117.1-2009 TABLE 603.6 MAXIMUM REACH DEPTH AND HEIGHT CLEARLENGTH OF BATHTUBCLEAR 30" MIN HEAD END CONTROL END CLEARLENGTH OF BATHTUB & SEAT12"CLEAR 30" MIN HEAD END CONTROL END30" MIN52" MIN BACK WALL 36" MIN SEAT WALL36" MINENTRANCE 36" MIN CLEAR FLOOR SPACE AT TUB W/ PERMANENT SEAT (PUBLIC) ICC A117.1-2009 CLEAR FLOOR SPACE AT TUB W/O PERMANENT SEAT (PUBLIC) ICC A117.1-2009 18"4" MAXCONTROL WALL3" - 6"48" MAXCONTINUOUS GRAB BAR CONTROL AREA HAND-HELD SHOWER UNIT W/ 59" MIN HOSE 36"33" - 36" TO TOP4" MAX 18" MIN38" MINCONTROL WALL 15" MAX TRANSFER SHOWER (PUBLIC) ICC A117.1-2009 17" - 19"18" 36" CLEAR BACK WALL 16" MIN 27" MAX 48" MAX38" MIN33" - 36" TO TOP33" - 36" TO TOPCLEAR60" MINCLEAR 30" MIN CONTROL WALLCLEAR FLOOR SPACE ROLL-IN SHOWER (PUBLIC) ICC A117.1-2009 SIDE WALL SEAT WALL LAV. COMPLYING W/ SEC. 606 PERMITTED CLEAR FLOOR SPACE TRANSFER SHOWER (PUBLIC) ICC A117.1-2009 MAX 6" MAX 6"EDGE OF SEATMAX6"MAX 6" SHEET NO. PROJECT NO. SHEET TITLE: REVISIONS / ISSUES DRAWN BY: PROFESSIONAL SEAL DATE: CHECKED BY: PROJECT: PROJECT ADDRESS COPYRIGHT AND OWNERSHIP OF DOCUMENTS NOTICE CONSULTANTS ARCHITECT OF RECORD: 8400 E. CRESCENT PARKWAY, SUITE 160 GREENWOOD VILLAGE, CO 80111 Tel: 720-881-1600 WWW.101ARCHITECTURE.COM ARCHITECTURE PLANNING INTERIOR DESIGN THIS DRAWING WAS PREPARED FOR A SPECIFIC USE ON A SPECIFIC SITE CONTEMPORANEOUSLY WITH ITS ISSUE DATE AND IT IS NOT TO BE USED ON A DIFFERENT PROJECT. THIS DRAWING IS AN INSTRUMENT OF PROFESSIONAL SERVICE AND IS PROTECTED BY COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING COPYRIGHT. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT THE WRITTEN CONSENT OF THE DESIGN PROFESSIONAL©2020 TYPICAL MOUNTING HEIGHTS G-401 21-101A014 01/24/2022 EVERHOME SUITES - BOZEMAN 959 FOWLER AVENUE BOZEMAN, MT 59718 BG FM SITE PLAN PACKAGE NO. DESCRIPTION DATE ISSUED FOR PERMIT02/16/2022 1/2" = 1'-0"1 STANDARD MOUNTING HEIGHTS - ANSI 2017