HomeMy WebLinkAboutSA100ShellFloorPlan1
SA2.00 2
1
1
3 5
5 64
A A
B
C
E
F
E.W6
E.W6
E.W6
E.W6
E.W6
E.W6
E.W6
E.W6 E.W6
E.W6
E.W6
E.W6
2
SA2.00
3
SA2.00
4
SA2.00
4'-0" 59'-5" 21'-5"
84'-10"
22
'
-
7
"
54
'
-
3
"
4'-
0
"
80
'
-
1
0
"
D
I.W6
I.W6
S101
S102
S103
S1
0
4
AAAAA
A
A
A
A
A A A A
A
A
A
A
7'-
1
1
3
/
4
"
1
SA3.00
1
SA3.00
2
SA3.00
2
SA3.00
3
SA3.00
3
SA3.00
4
SA3.00
4
SA3.00
SF2
SF1
SF4
SF3
SF3
I.W6
12'-1" 4'-0" 5'-7" 4'-0" 5'-7" 4'-0" 5'-7" 4'-0" 5'-7" 4'-0"5'-0"
19
'
-
2
"
4'-
0
"
5'-
9
"
4'-
0
"
5'-
9
"
4'-
0
"
5'-
9
"
4'-
0
"
3'-
0
"
4'-
0
"
55
'
-
5
"
21
'
-
5
"
21'-5" 59'-5"
15'-7" 4'-0" 7'-10" 4'-0" 7'-10" 4'-0" 7'-10" 4'-0" 4'-4"
10
'
-
1
"
4'-
0
"
5'-
1
"
4'-
0
"
5'-
1
"
4'-
0
"
5'-
3
"
3'-
2
"
5'-
3
"
4'-
0
"
4'-
4
"
4'-4" 13'-0" 4'-1"
5'-
0
"
13
'
-
0
"
4'-
7
"
4'-
1
"
13
'
-
0
"
4'-
4
"
4'-4" 13'-0" 4'-1"
MECHANICAL
SCREENING
FENCE
2'-0"
8'-
0
"
DOOR
CANOPY
ABOVE
CANOPY
ABOVE
CANOPY
ABOVE
WINDOW
CANOPY
ABOVE
2
SA0.10
2
SA0.10
1
SA2.00 2 3 5 64
A
B
C
E
F
2
SA2.00
3
SA2.00
4
SA2.00
D
1
SA3.00
1
SA3.00
2
SA3.00
2
SA3.00
3
SA3.00
3
SA3.00
4
SA3.00
4
SA3.00
MB -1
SS -1
MB -1
1:
1
2
1/4" / 12" 1/4" / 12"
MAIN SCUPPER,
DOWNSPOUT AND
OVERFLOW SCUPPER
MAIN SCUPPER,
DOWNSPOUT AND
OVERFLOW SCUPPER
MAIN SCUPPER AND
DOWNSPOUT AND OVERFLOW
SCUPPER
MAIN SCUPPER AND
DOWNSPOUT AND
OVERFLOW SCUPPER
MTL PARAPET CAP
MTL PARAPET CAP
MTL PARAPET CAP
30'-0"
30
'
-
0
"
RI
D
G
E
SLOPE TO DRAIN SLOPE TO DRAIN
GUTTER, SLOPE EAST TO
DRAIN TO LOWER ROOF
11'-3"
WINDOW CANOPY
44'-0"
DO
O
R
C
A
N
O
P
Y
10
'
-
0
"
WINDOW CANOPY
41'-0" 3'-7"
2'-
3
"
25'-2 1/2"
3'-6"
2'-
3
"
SCUPPER TO DRAIN TO
LOW ROOF
SCUPPER TO DRAIN TO
LOW ROOF
BUILDING
OUTLINE
BELOW
3'-3"
25
'
-
7
1
/
4
"
2'-
9
"
2
SA0.10
2
SA0.10
SHELL FLOOR PLAN GENERAL NOTES
1. PLAN ELEMENTS REPRESENTED IN BLACK ARE INCLUDED IN THE SHELL
CONTRACT
2. PLAN ELEMENTS REPRESENTED IN GRAY ARE INCLUDED IN THE TENANT
IMPROVEMENT CONTRACT
3. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD
PRIOR TO CONSTRUCTION AND ORDERING MATERIALS
4. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE OR EXTERIOR
FACE OF STUD FRAMING
5. REFER TO STRUCTURAL DRAWINGS FOR FRAMING, FOUNDATION,
TRUSSES, JOISTS, BEAMS, COLUMNS, AND OTHER STRUCTURAL ELEMENTS
6. PROVIDE 3/4" FTR PLYWOOD FOR ELECTRICAL MOUNTING BOARDS IN
MECHANICAL ROOM
7. BELOW-GRADE WALLS TO HAVE DAMPPROOFING AND APPROPRIATE
WATER STOPPING AT JOINTS
SHELL ROOF PLAN GENERAL NOTES
1. VERIFY ANY EQUIPMENT AND CURB SIZES WITH
MECHANICAL CONTRACTOR
2. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL
REINFORCEMENT OF ANY ROOF OPENINGS
3. PROVIDE CRICKETS AS REQUIRED FOR POSITIVE
DRAINAGE
EXTERIOR
PARAPET CAP, UNO
METAL PANEL PER ELEVATIONS
2" RIGID INSULATION
WEATHER BARRIER
SHEATHING PER STRUCT
2X6 WD STUD, W/ BATT INSUL.
5/8" GWB
E.W6 I.W6
5/8" GWB
2X6 WD STUD, W/
BATT INSUL.
5/8" GWB, PAINT
FLOOR TYPES LEGEND -SHELL
3/4" PLY
FR-1
FRAMING PER STRUCT
E.C
R-10, 2" RIGID
INSULATION
CONC WALL PER
STRUCT
DAMPPROOFING
GRID GRID
WALL TYPES LEGEND -SHELL
INTERIOR
• FIRST LETTER INDICATED EXTERIOR (E) OR INTERIOR (I).
• SECOND LETTER INDICATED WOOD (W) OR METAL (M) STUD OR
CONCRETE (C) FOUNDATION.
• "A" IN THE NAME INDICATED ACOUSTIC WALL.
• "F" IN THE NAME INDICATED FURRING WALL.
• THE FIRST NUMBER IN THE NAME INDICATES STUD SIZE PER SIZING
LEGENDS BELOW.
• THE SECOND NUMBER OF THE NAME INDICATES THE FIRE RATING (IF
USED).
WOOD STUDE SIZE LEGEND
• 4 = 3 1/2"
• 6 = 5 1/2"
CON-1
4" CONCRETE
SLAB ON GRADE
ROOF TYPES LEGEND -SHELL
STANDING SEAM METAL ROOF
ROOFING UNDERLAYMENT
SHEATHING PER STRUCT
FRAMING PER STRUCT
SHEATHING PER STRUCT
PRIMARY ROOF
FRAMING PER STRUCT
R-49 BATT INSULATION IN
ATTIC - ABOVE CEILING,
BELOW FRAMING FOR
THERMAL CONTINUITY
SS-1
MEMBRANE ROOF
R-30 MIN. (AT ROOF DRAINS)
ROOF INSULATION
FRAMING PER STRUCT
SHEATHING PER STRUCT
PRIMARY ROOF FRAMING
PER STRUCT
MB-1
1/8" = 1'-0" SA1.00
SHELL - FLOOR PLAN 1
1/8" = 1'-0" SA1.00
SHELL - ROOF 2
PLAN NORTH PLAN NORTH
Date:
45 Arch Project Number:
Sheet Name
AL
L
D
R
A
W
N
A
N
D
W
R
I
T
T
E
N
I
N
F
O
R
M
A
T
I
O
N
A
P
P
E
A
R
I
N
G
S
H
A
L
L
N
OT
B
E
D
U
P
L
I
C
A
T
E
D
,
D
I
S
C
L
O
S
E
D
O
R
O
T
H
E
R
W
I
S
E
U
S
E
D
W
I
T
H
O
UT
T
H
E
W
R
I
T
T
E
N
C
O
N
S
E
N
T
OF
4
5
A
R
C
H
I
T
E
C
T
U
R
E
.
Co
n
s
u
l
t
a
n
t
N O T F O R
C O N S T R U C T I O N
1216 W Lincoln Street, Suite D
Bozeman, Montana 59715
(406) 577-2345
www.45arch.com
REVISIONS
10
/
1
/
2
0
2
1
9
:
0
1
:
2
7
A
M
SA1.00
SHELL FLOOR &
ROOF PLAN
TH
E
R
I
D
G
E
L
O
T
7
A
SEPTEMBER 20, 2021
21025
TB
D
F
A
L
L
O
N
S
T
,
B
O
Z
E
M
A
N
M
T
5
9
7
1
8
BL
A
C
K
D
I
R
T
,
L
L
C
SH
E
L
L
NO. DESCRIPTION DATE