Loading...
HomeMy WebLinkAbout009--A2.5 Noted Second Floor PlanDN A A5.2 A A5.2 A6.11 A6.1 2 2 2 3 3 4 4 5 5 A A B B C C D D E E F F A6.3 3 A6.2 1 B A5.2 B A5.2 A6.4 2 A6.4 1 A6.3 2 A6.4 3 A6.2 3 A6.3 1 1 1 HALLWAY 201 BEDROOM #2 202 C.L. #2 203 BATH 204 SHWR. 205 BEDROOM #3 206 C.L. #3 207 STUDY 208 C.L. 209 SD SD 18R@7" 17T@11" SD TV TV OPEN TO BELOW SD C A5.3 C A5.3 2 A5.3 2 A5.3 V A R I E S 12 ' - 6 1 / 2 " 12' - 6" 12' - 6" 12 ' - 6 1 / 2 " EACH FIREPLACE SHALL BE PROV IDED WITH AN EXTERIOR COMBUSTION AIR PIPE 4" DIA. AIR IN TAKE SHALL NOT BE LOCATED AT AN ELEV ATION HIGHER THAN THE FIREBOX. EACH FIREPLACE SHALL CONTAIN A PERMAN EN TLY IN STALLED GAS LOG SET WITH ELECTRONIC START LOCATED BY THE OWNER. PROV IDE GAS SHUT-OFF V ALV E WITHIN 6 FEET OF THE FIREPLACE PER IRC G2420. V ERIFY LOCATION W/ OWN ER. TOP OF CHIMNEYS SHALL EXTEND A MINIMUM OF 2'-0" ABOV E ANY PORTION OF THE ROOF WITHIN A 10'-0" RADIUS. COMBUSTIBLE MATERIAL SHALL N OT BE PLACED WITHIN 2" OF FIREPLACES, SMOKE CHAMBER OR CHIMNEY WALLS. COMBUSTIBLE MATERIAL SHALL N OT BE PLACED WITHIN 6" OF THE FIREPLACE OPEN ING. NO SUCH COMBUSTIBLE MATERIAL WITHIN 12" OF THE FIREPLACE OPENING SHALL PROJECT MORE THAN 1/8" FOR EACH 1" DISTAN CE FROM SUCH OPEN IN G. IRC R1 003.18 EXTERIOR FIREPLACES AN D CHIMN EYS TO BE MASON RY CONSTRUCTION WITH 8" MIN IMUM SOLID MASON RY ADJACENT TO ALL FIREBOXES AND FLUES. EACH FIREPLACE SHALL CON TAIN A PERMANENTLY IN STALLED GAS LOG SET WITH ELECTRONIC START LOCATED BY THE OWNER. PROV IDE GAS SHUT-OFF V ALV E WITHIN 6 FEET OF THE FIREPLACE PER IRC G2420. V ERIFY LOCATION W/ OWN ER. MASON TO V ERIFY FLUE SIZING V ERSUS FIREPLACE OPENING AND CHIMN EY HEIGHTS FOR PROPER FIREBOX AND CHIMNEY OPERATION. FP-1 TBD TBD TBD FP-2 72" W x 28" H x 25" D 2'-8 1/2" TBD FP# W x H x D HEIGHT FLUE SIZE R312.2 WINDOW FALL PROTECTION IN DWELLIN G UN ITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WIN DOW OPEN IN G IS LOCATED LESS THAN 24 IN CHES ABOV E THE FINISHED FLOOR AND GREATER THAN 72 INCHES ABOV E THE FIN ISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE WIN DOW SHALL COMPLY WITH ONE OF THE FOLLOWIN G 1. OPERABLE WINDOW OPENINGS WILL NOT ALLOW A 4-INCH DIAMITER SPHERE TO PASS THROUGH WHERE THE OPEN IN GS ARE IN THEIR LARGEST POSITION 2. OPERABLE WINDOWS ARE PORIV DED WITH WIN DOW FALL PREV EN TION DEV ICES THAT COMPLY WITH ASTM F2090 3. OPERABLE WINDOWS ARE PROV IDED WITH WINDOW OPENING CONTROL DEV ICES THAT COMPLY WITH SECTION R312.2.2 STAIR WIDTH SHALL N OT BE LESS THAN 36" IN CLEAR WIDTH. (IRC-R311.7.1) TREADS & RISERS THE MAX. RISER HEIGHT SHALL BE 7-3/4" (IRC-R311.7.5.1) AND THE MIN. TREAD DEPTH SHALL BE 10". (IRC-R311.7.5.2) WINDER TREADS SHALL HAV E A MIN. TREAD DEPTH OF 10" MEASURED AT A POINT 12" FROM THE SIDE WHERE THE TREADS ARE N ARROWER. WIN DER TREADS SHALL HAV E A MIN . TREAD DEPTH OF 6" AT AN Y POIN T. (IRC-R311.7.5.2) LANDING WIDTH SHALL N OT BE LESS THAN THE STAIRWAY OR DOOR SERV ED. EV ERY LANDIN G SHALL HAV E A MIN. DIM. OF 36" MEASURED IN THE DIRECTION OF TRAV EL. (IRC-R311.7.6) HANDRAIL HEIGHT SHALL BE A MIN. OF 34" AND A MAX. OF 38" MEASURED V ERTICALLY FROM THE NOSING OF THE TREADS, AN D SHALL BE PROV IDED ON AT LEAST ONE SIDE OF STAIRWAYS. (IRC- R311.7.8.1) CONTINUITY HAN DRAILS FOR STAIRWAYS SHALL BE CON TINUOUS FOR THE FULL LEN GTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOV E THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOV E THE LOWEST RISER OF THE FLIGHT. HAN DRAIL EN DS SHALL BE RETURNED OR SHALL TERMIN ATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACEN T TO A WALL SHALL HAV E A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AN D THE HAN DRAIL. (IRC-311.7.8.2) GUARDRAIL HEIGHT SHALL N OT BE LESS THAN 36". (IRC-R312.1.2) RAIL SPACING RAILS SHALL BE SPACED SO AS N OT TO ALLOW PASSAGE OF A SPHERE 4" IN DIA. (IRC-R312.1.3) THE TRIANGULAR OPEN ING AT THE OPEN SIDE OF THE STAIR, FORMED BY THE RISER, TREAD AN D BOTTOM RAIL OF A GUARD, SHALL N OT ALLOW THE PASSAGE OF A SPHERE 6 INCHES IN DIAMETER. (IRC-312.1.3 -1) GUARDS ON THE OPEN SIDES OF THE STAIRS SHALL N OT HAV E OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4-3/8 INCHES IN DIAMETER. (IRC-312.1.3 -2) 110 PERMANENTLY WIRED, IN TERCON NECTED SMOKE DETECTOR WITH BATTERY BACKUP AND CARBON MONIXIDE ALARM SD 2 3 4 5 6 7 8 9 10 F E D C B A G H 1 PROJECT NO: DATE: 21011 01/03/2022 All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. SC H E M A T I C D E S I G N S E T NO T F O R C O N S T R U C T I O N 1/ 3 / 2 0 2 2 1 1 : 2 7 : 5 4 A M C : \ U s e r s \ c h r i s \ O n e D r i v e \ D o c u m e n t s \ 2 1 0 0 5 - - 2 0 9 S . 8 t h C a s h m a n R e s i d e n c e - - C e n t r a l - - _ c h r i s T M M N D . r v t CA S H M A N R E S I D E N C E 20 8 S . 8 T H A V E . BO Z E M A N M T , 5 9 7 1 5 A2.5 N OTED SECON D FLOOR PLAN NORTH SCALE: 3/16" = 1'-0"1 NOTED SECOND FLOOR PLAN FIREPLACE WIN DOW FALL PROTECTION AREA CALCULATION S CON DITION ED CASITA - ADU 586 SF MAIN FLOOR 1929 SF SECON D FLOOR 837 SF STUDIO 259 SF 3611 SF N ON -CON DITION ED GARAGE/MECH.938 SF FIREPLACE PATIO 315 SF SAUN A 53 SF 1307 SF Grand total 4918 SF KEYN OTES STAIR & HAN DRAIL N OTES SMOKE DETECTOR LEGEND REV ISION S N O. DATE DESCRIPTION 03/22/22 22003 209 S. 8th Avenue NCOA