HomeMy WebLinkAbout008--A2.4 Noted First Floor PlanTR DW
W/D
R EF.
UP
R EF.
DN
EACH FIR EPLACE SHALL BE PR OVIDED WITH AN EXTER IOR
COMBUSTION AIR PIPE 4" DIA. AIR IN TAKE SHALL NOT BE
LOCATED AT AN ELEVATION HIGHER THAN THE FIR EBOX. EACH
FIR EPLACE SHALL CONTAIN A PER MAN EN TLY IN STALLED GAS
LOG SET WITH ELECTR ONIC STAR T LOCATED BY THE OWNER .
PR OVIDE GAS SHUT-OFF VALVE WITHIN 6 FEET OF THE
FIR EPLACE PER IR C G2420. VER IFY LOCATION W/ OWN ER .
TOP OF CHIMNEYS SHALL EXTEND A MINIMUM OF 2'-0" ABOVE
ANY POR TION OF THE R OOF WITHIN A 10'-0" R ADIUS.
COMBUSTIBLE MATER IAL SHALL N OT BE PLACED WITHIN 2" OF
FIR EPLACES, SMOKE CHAMBER OR CHIMNEY WALLS.
COMBUSTIBLE MATER IAL SHALL N OT BE PLACED WITHIN 6" OF
THE FIR EPLACE OPEN ING. NO SUCH COMBUSTIBLE MATER IAL
WITHIN 12" OF THE FIR EPLACE OPENING SHALL PR OJECT
MOR E THAN 1/8" FOR EACH 1" DISTAN CE FR OM SUCH OPEN IN G.
IR C R 1 003.18
EXTER IOR FIR EPLACES AN D CHIMN EYS TO BE
MASON R Y CONSTR UCTION WITH 8" MIN IMUM SOLID
MASON R Y ADJACENT TO ALL FIR EBOXES AND FLUES.
EACH FIR EPLACE SHALL CON TAIN A PER MANENTLY
IN STALLED GAS LOG SET WITH ELECTR ONIC STAR T
LOCATED BY THE OWN ER . PR OVIDE GAS SHUT-OFF
VALVE WITHIN 6 FEET OF THE FIR EPLACE PER IR C
G2420. VER IFY LOCATION W/ OWN ER .
MASON TO VER IFY FLUE SIZING VER SUS FIR EPLACE
OPENING AND CHIMN EY HEIGHTS FOR PR OPER
FIR EBOX AND CHIMNEY OPER ATION.
FP-1 TBD TBD TBD
FP-2 72" W x 28" H x 25" D 2'-8 1/2" TBD
FP# W x H x D HEIGHT FLUE SIZE
R312.2 WINDOW FALL PROTECTION
IN DWELLIN G UNITS, WHER E THE TOP OF THE SILL OF AN
OPER ABLE WIN DOW OPEN IN G IS LOCATED LESS THAN 24
IN CHES ABOVE THE FINISHED FLOOR AND GR EATER THAN 72
INCHES ABOVE THE FIN ISHED GR ADE OR OTHER SUR FACE
BELOW ON THE EXTER IOR OF THE BUILDING, THE OPER ABLE
WIN DOW SHALL COMPLY WITH ONE OF THE FOLLOWIN G
1. OPER ABLE WINDOW OPENINGS WILL NOT ALLOW A 4-INCH
DIAMITER SPHER E TO PASS THR OUGH WHER E THE OPEN IN GS
AR E IN THEIR LAR GEST POSITION
2. OPER ABLE WINDOWS AR E POR IVDED WITH WIN DOW FALL
PR EVEN TION DEVICES THAT COMPLY WITH ASTM F2090
3. OPER ABLE WINDOWS AR E PR OVIDED WITH WINDOW
OPENING CONTR OL DEVICES THAT COMPLY WITH SECTION
R 312.2.2
A
A5.2
A
A5.2
A6.11
A6.1
2
2
2
3
3
4
4
5
5
A A
B B
C C
D D
E E
F F
A6.3
3
A6.2 1
B
A5.2
B
A5.2
A6.4 2A6.4 1
A6.3 2 A6.4 3
A6.2
3
A6.3
1
1
1
ENTRY
101
GALLERY
102
LIVING
ROOM
103
OWNER
ENTRY
106
LAUNDRY
ROOM
107
STOR.
108
PRIMARY
BEDROOM
124
BATH
125
SHWR
127
PRIMARY CL
128
STAIRS
129
GARAGE
130
MECH.
131
STUDIO
132
MECH.
133
SAUNA
134
KITCHEN
C-102
LIVING
ROOM
C-101
LDRY .
C-103
BATH
C-104
BEDROOM
C-105
C.L.
C-106
4"
4R @7"
3T@11"
KITCHEN
104
DINING
ROOM
105
18R @7"
17T@11"
PWDR.
109 WC
126
SD
SD
DN .
3R @7"
2T@11"
DN .
5R @7"
4T@11"
DN .
DN .
2R @7"
1T@11"
2R @7"
1T@11"
F.P. #2
F.P. #1
4"
4
"
4"
4"
1/8" / 12"
SD
SD
SD
VA
R
I
E
S
3"
W.H.
TV
TV
TV
TV
TV
C
A5.3
C
A5.3
2
A5.3
2
A5.3
CA
B
I
N
E
T
S
CA
B
I
N
E
T
S
BE
N
C
H
CABINETS
14
'
-
0
"
14' - 0"
4'
-
1
1
1
/
2
"
12' - 0"
12
'
-
0
"
13
'
-
0
"
17' - 10 1/2"
DN .
2R @ 6"
1T @ 12"
31' - 0"
110 PER MANENTLY WIR ED, IN TER CON NECTED SMOKE
DETECTOR WITH BATTER Y BACKUP AND CAR BON
MONIXIDE ALAR M
SD
STAIR WIDTH SHALL N OT BE LESS THAN 36" IN CLEAR
WIDTH. (IR C-R 311.7.1)
TREADS & RISERS THE MAX. R ISER HEIGHT SHALL BE 7-3/4"
(IR C-R 311.7.5.1) AND THE MIN. TR EAD DEPTH
SHALL BE 10". (IR C-R 311.7.5.2)
WINDER TREADS SHALL HAVE A MIN. TR EAD DEPTH OF 10"
MEASUR ED AT A POINT 12" FR OM THE SIDE
WHER E THE TR EADS AR E N AR R OWER .
WIN DER TR EADS SHALL HAVE A MIN . TR EAD
DEPTH OF 6" AT AN Y POIN T. (IR C-R 311.7.5.2)
LANDING WIDTH SHALL N OT BE LESS THAN THE STAIR WAY
OR DOOR SER VED. EVER Y LANDIN G SHALL
HAVE A MIN. DIM. OF 36" MEASUR ED IN THE
DIR ECTION OF TR AVEL. (IR C-R 311.7.6)
HANDRAIL HEIGHT SHALL BE A MIN. OF 34" AND A MAX. OF 38"
MEASUR ED VER TICALLY FR OM THE NOSING
OF THE TR EADS, AN D SHALL BE PR OVIDED
ON AT LEAST ONE SIDE OF STAIR WAYS. (IR C-
R 311.7.8.1)
CONTINUITY HAN DR AILS FOR STAIR WAYS SHALL BE
CONTINUOUS FOR THE FULL LEN GTH OF
THE FLIGHT, FR OM A POINT DIR ECTLY
ABOVE THE TOP R ISER OF THE FLIGHT TO A
POINT DIR ECTLY ABOVE THE LOWEST R ISER
OF THE FLIGHT. HAN DR AIL EN DS SHALL BE
R ETUR NED OR SHALL TER MIN ATE IN NEWEL
POSTS OR SAFETY TER MINALS. HANDR AILS
ADJACEN T TO A WALL SHALL HAVE A SPACE
OF NOT LESS THAN 1-1/2" BETWEEN THE
WALL AN D THE HAN DR AIL. (IR C-311.7.8.2)
GUARDRAIL HEIGHT SHALL N OT BE LESS THAN 36". (IR C-R 312.1.2)
RAIL SPACING R AILS SHALL BE SPACED SO AS N OT TO
ALLOW PASSAGE OF A SPHER E 4" IN DIA.
(IR C-R 312.1.3) THE TR IANGULAR OPEN ING AT
THE OPEN SIDE OF THE STAIR , FOR MED BY
THE R ISER , TR EAD AN D BOTTOM R AIL OF A
GUAR D, SHALL N OT ALLOW THE PASSAGE
OF A SPHER E 6 INCHES IN DIAMETER .
(IR C-312.1.3 -1)
GUAR DS ON THE OPEN SIDES OF THE
STAIR S SHALL N OT HAVE OPENINGS THAT
ALLOW PASSAGE OF A SPHER E 4-3/8 INCHES
IN DIAMETER . (IR C-312.1.3 -2)
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
G
H
1
PR OJECT NO:
DATE:
21011
01/03/2022
All reports, drawings, specifications, computer
files, field data, notes, other documents and
instruments prepared by the Architect as
instruments of service shall remain the property
of the Architect, LocalElementArchitects, LLC.
The Architect shall retain all common law,
statutory and other reserved rights, including
copyright thereto. The use of this drawing shall
be restricted to the original site for which it was
prepared and publication thereof is expressly
limited to such use. R euse, reproduction or
publication by any method is prohibited without
written consent from LocalElementArchitects,
LLC.
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
S
E
T
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
1/
3
/
2
0
2
2
1
1
:
2
7
:
5
1
A
M
C
:
\
U
s
e
r
s
\
c
h
r
i
s
\
O
n
e
D
r
i
v
e
\
D
o
c
u
m
e
n
t
s
\
2
1
0
0
5
-
-
2
0
9
S
.
8
t
h
C
a
s
h
m
a
n
R
e
s
i
d
e
n
c
e
-
-
C
e
n
t
r
a
l
-
-
_
c
h
r
i
s
T
M
M
N
D
.
r
v
t
CA
S
H
M
A
N
R
E
S
I
D
E
N
C
E
20
8
S
.
8
T
H
A
V
E
.
BO
Z
E
M
A
N
M
T
,
5
9
7
1
5
A2.4
N OTED FIR ST
FLOOR PLAN
FIR EPLACE
WIN DOW FALL PR OTECTION
NORTH
SCALE: 3/16" = 1'-0"1 NOTED FIRST FLOOR PLAN
KEYN OTES
AR EA CALCULATION S
CON DITION ED
CASITA - ADU 586 SF
MAIN FLOOR 1929 SF
SECON D FLOOR 837 SF
STUDIO 259 SF
3611 SF
N ON -CON DITION ED
GAR AGE/MECH.938 SF
FIR EPLACE PATIO 315 SF
SAUN A 53 SF
1307 SF
Grand total 4918 SF
STAIR & HAN DR AIL N OTES
SMOKE DETECTOR LEGEND
R EVISION S
N O. DATE DESCR IPTION
03/22/22
22003 209 S. 8th Avenue NCOA