HomeMy WebLinkAbout006--D6.1 Demo ElevationsD1.2
D1.1
D1.1
D1.2
D1.1
D1.2 D1.2
D1.1
A. PROTECT ALL FLOORING, WALLS AND MATERIALS
THAT ARE TO REMAIN DURING DEMOLITION AND
CONSTRUCTION.
B. PROTECT TO THE EXTENT POSSIBLE ALL LANDSCAPE
AND SITEWORK THAT IS TO REMAIN DURING
DEMOLITION AND CONSTRUCTION.
C. ALL EXTERIOR WINDOWS AND DOORS ARE TO BE
REPLACED - PROTECT ROUGH OPENING FOR RE-
INSTALLATION.
D. DO NOT ALTER THE STRUCTURAL INTEGRITY OF THE
EXISTING STRUCTURE OR IT'S ASSEMBLIES UNLESS
SPECIFICALLY NOTED OTHERWISE. PROTECT
COLUMNS AND OTHER STRUCTURAL ELEMENTS
DURING DEMOLITION AND CONSTRUCTION.
E. VERIFY WITH OWNER ALL ITEMS THAT ARE SHOWN ON
THE DEMO PLAN TO BE REMOVED PRIOR TO
REMOVING OR DEMOLITION.
F. PROMPTLY REMOVE ALL MATERIAL AND DEBRIS
REMOVED DURING DEMOLITION FROM THE PROPERTY,
AND DISPOSE OF THEM IN ACCORDANCE WITH LOCAL
ORDINANCES.
G. SECURE THE PROPERTY TO THE EXTENT POSSIBLE
DURING DEMOLITION.
H. UPON COMPLETION OF DEMOLITION, PATCH AND
REPAIR ALL EXISTING SURFACES, OPENINGS, AND
ROOF PENETRATIONS.
I. EXISTING MATERIALS SHALL BE PROTECTED FROM
DAMAGE AT ALL TIMES. EXISTING BUILDING MATERIALS
AND/OR FINISHES THAT ARE DAMAGED SHALL BE
REPAIRED AND/OR REPLACED AND APPROVED BY
THE OWNER/ARCHITECT AT NO ADDITIONAL COST.
J. IF HAZARDOUS MATERIALS SUCH AS ASBESTOS ARE
ENCOUNTERED, CEASE WORK AND IMMEDIATELY
NOTIFY THE OWNER AND CONSTRUCTION MANAGER
WHO WILL ARRANGE APPROPRIATE MITIGATION. DO
NOT COMMENCE WORK UNTIL MITIGATION IS
CERTIFIED.
K. DEMO AND REPLACE ANY WATER DAMAGED, ROTTEN,
MOLDY OR STRUCTURALY COMPRISED FRAMING,
SHEATHING, OR BLOCKING. NOTIFY ARCHITECT IF ANY
DAMAGED AREAS ARE FOUND.
L. REMOVE AND DISCARD ALL EXISTING INTERIOR
FINISHES TO EXPOSE WOOD STUD
FRAMING/SHEATHING/JOISTS
EXISTING WALL/ELEMENT TO BE
DEMOLISHED
EXISTING WALL TO REMAIN
EXISTING WALL/ELEMENT TO BE
DEMOLISHED
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE DEMOLISHED
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
G
H
1
PROJECT NO:
DATE:
21011
01/03/2022
All reports, drawings, specifications, computer
files, field data, notes, other documents and
instruments prepared by the Architect as
instruments of service shall remain the property
of the Architect, LocalElementArchitects, LLC.
The Architect shall retain all common law,
statutory and other reserved rights, including
copyright thereto. The use of this drawing shall
be restricted to the original site for which it was
prepared and publication thereof is expressly
limited to such use. Reuse, reproduction or
publication by any method is prohibited without
written consent from LocalElementArchitects,
LLC.
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
S
E
T
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
1/
3
/
2
0
2
2
1
1
:
2
8
:
3
3
A
M
C
:
\
U
s
e
r
s
\
c
h
r
i
s
\
O
n
e
D
r
i
v
e
\
D
o
c
u
m
e
n
t
s
\
2
1
0
0
5
-
-
2
0
9
S
.
8
t
h
C
a
s
h
m
a
n
R
e
s
i
d
e
n
c
e
-
-
C
e
n
t
r
a
l
-
-
_
c
h
r
i
s
T
M
M
N
D
.
r
v
t
CA
S
H
M
A
N
R
E
S
I
D
E
N
C
E
20
8
S
.
8
T
H
A
V
E
.
BO
Z
E
M
A
N
M
T
,
5
9
7
1
5
D6.1
DEMOLITION
ELEVATIONS
SCALE: 3/16" = 1'-0"2
DEMOLITION EAST
ELEVATION
SCALE: 3/16" = 1'-0"1
DEMOLITION NORTH
ELEVATION
SCALE: 3/16" = 1'-0"3
DEMOLITION SOUTH
ELEVATION
SCALE: 3/16" = 1'-0"5
DEMOLITION WEST
ELEVATION
D1.1 DEMOLISH AND DISCARD EXISTING STRUCTURE -
COORDINATE WITH OWNER ON RE-USE OR
DONATION OF ANY INTERIOR ITEMS
D1.2 DEMOLISH AND DISCARD EXISTING FOUNDATION
DEMO KEYNOTES
DEMO NOTES
DEMO LEGEND
REVISIONS
NO. DATE DESCRIPTION
03/22/22
22003 209 S. 8th Avenue NCOA