PROJECT NO:
DATE:
21011
01/03/2022
All reports, drawings, specifications, computer
files, field data, notes, other documents and
instruments prepared by the Architect as
instruments of service shall remain the property
of the Architect, LocalElementArchitects, LLC.
The Architect shall retain all common law,
statutory and other reserved rights, including
copyright thereto. The use of this drawing shall
be restricted to the original site for which it was
prepared and publication thereof is expressly
limited to such use. Reuse, reproduction or
publication by any method is prohibited without
written consent from LocalElementArchitects,
LLC.
SC
H
E
M
A
T
I
C
D
E
S
I
G
N
S
E
T
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
1/
3
/
2
0
2
2
1
1
:
2
7
:
4
2
A
M
C
:
\
U
s
e
r
s
\
c
h
r
i
s
\
O
n
e
D
r
i
v
e
\
D
o
c
u
m
e
n
t
s
\
2
1
0
0
5
-
-
2
0
9
S
.
8
t
h
C
a
s
h
m
a
n
R
e
s
i
d
e
n
c
e
-
-
C
e
n
t
r
a
l
-
-
_
c
h
r
i
s
T
M
M
N
D
.
r
v
t
CA
S
H
M
A
N
R
E
S
I
D
E
N
C
E
20
8
S
.
8
T
H
A
V
E
.
BO
Z
E
M
A
N
M
T
,
5
9
7
1
5
A0.2
GENERAL NOTES
GENERAL NOTES
STANDARDS AND REGULATIONS
1. PERFORM ALL WORK IN CONFORMANCE WITH
APPLICABLE BUILDING CODES, REGULATIONS, ORDINANCES,
UTILITY PROVIDER REQUIREMENTS AND SIMILAR
STANDARDS.
2. OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES
REQUIRED FOR CONSTRUCTION AND OCCUPANCY. FURNISH
COPIES OF ALL SUCH ITEMS TO OWNER AND ARCHITECT
WITHIN TEN (10) DAYS OF RECEIPT. IF PERMITS ARE ISSUED
SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE
WORK, OR IF PERMITS ARE DELAYED FOR ANY REASON,
NOTIFY THE ARCHITECT IMMEDIATELY.
3. OBTAIN ALL REQUIRED INSPECTIONS OF THE WORK AS
REQUIRED BY THE GOVERNING MUNICIPALITY. REGULARLY
UPDATE OWNER AND ARCHITECT REGARDING THE STATUS
OF INSPECTIONS.
4. MISCELLANEOUS SITE STRUCTURES, POOLS, SPAS,
FENCES, SITE WALLS, RETAINING WALLS, AND GAS STORAGE
TANKS REQUIRE SEPARATE PERMITS.
5. ALL PRODUCTS LISTED BY ICC/N.E.R NUMBER(S) SHALL BE
INSTALLED PER THE REPORT AND MANUFACTURER'S
WRITTEN INSTRUCTIONS. PRODUCT SUBSTITUTION(S) FOR
PRODUCTS LISTED SHALL ALSO HAVE AN ICC APPROVED
EVALUATION REPORT(S) OR BE APPROVED.
6. PROVIDE ENGINEERED TRUSS DESIGNS FOR ALL
PREFABRICATED TRUSSES FOR REVIEW AND APPROVAL BY
THE A.H.J.
ADMINISTRATION OF THE WORK:
1. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE
MEANS, METHODS AND SEQUENCE OF CONSTRUCTION.
2. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE
SAFETY OF ALL CONSTRUCTION PERSONNEL AND
AUTHORIZED VISITORS.
3. VISIT JOB SITE AND INSPECT THE PREMISES TO BECOME
FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE
WORK. LAY OUT WORK AS SOON AS POSSIBLE. REPORT
ANY KNOWN DISCREPANCIES BETWEEN THE DOCUMENTS
AND ACTUAL CONDITIONS TO THE ARCHITECT FOR
RESOLUTION PRIOR TO PROCEEDING WITH WORK RELATED
TO THE DISCREPANCY.
4. TAKE PRECAUTIONS TO MAINTAIN AND PROTECT SYSTEMS
AND FINISHES. ANY DAMAGES TO SUCH FINISHES SHALL BE
IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO THE
ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE MADE,
REPLACE SYSTEMS AND FINISHES WITH LIKE- NEW QUALITY
CONSTRUCTION ACCEPTABLE TO THE ARCHITECT AT NO
COST TO THE OWNER.
5. REMOVE AND PROPERLY DISPOSE OF ALL CONSTRUCTION
AND DEMOLITION DEBRIS. OBTAIN APPROVAL OF OWNER
(AND BUILDING OWNER, IF APPLICABLE) FOR DETAILS
RELATED TO REMOVAL OF TRASH, INCLUDING SUCH ISSUES
AS PATH OF TRAVEL, USE OF STAIRS AND ELEVATORS,
REMOVAL OF WINDOWS, LOCATION OF CHUTES AND
DUMPSTER, ETC., PRIOR TO REMOVAL OF DEBRIS. CLEAN
AND REPAIR ANY DAMAGES TO EXISTING SYSTEMS SOILED
OR DAMAGED BY DEBRIS REMOVAL PROCESS. IF CLEANING
AND REPAIR DOES NOT RETURN SYSTEMS TO ORIGINAL
CONDITION, INSTALL NEW SYSTEMS AT NO COST TO THE
OWNER.
6. BECOME FAMILIAR WITH AND COMPLY WITH OWNER'S (OR
BUILDING OWNER'S) PROCEDURES FOR MAINTAINING A
SECURE SITE AND BUILDING.
7. EXAMINE SUBSTRATE CONDITION AND/OR SITE
CONDITIONS WHICH AFFECT THE QUALITY OF EACH
PRODUCT TO BE INSTALLED. IF ANY CONDITIONS EXIST
WHICH WILL HAVE A DETRIMENTAL EFFECT ON THE QUALITY
OF THE INSTALLATION, THE INSTALLER SHALL IMMEDIATELY
NOTIFY THE CONTRACTOR. INSTALLATION SHALL NOT
PROCEED UNTIL THE UNSATISFACTORY CONDITIONS ARE
CORRECTED. INSTALLATION SHALL SIGNIFY ACCEPTANCE
OF THE CONDITIONS.
8. MAINTAIN PERMITTED CONSTRUCTION DOCUMENTS AND
ALL RECORD DOCUMENTS ON SITE AT ALL TIMES.
9. SUPERVISE AND COORDINATE THE WORK USING SKILL
AND ATTENTION. COORDINATE THE WORK OF ALL TRADES.
NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF
CONFLICTS THAT PREVENT THE WORK FROM BEING
COMPLETED AS DESIGNED.
USE OF CONSTRUCTION DOCUMENTS:
1. DO NOT SCALE DRAWINGS, ONLY WRITTEN DIMENSIONS OR
KEYED NOTES SHALL BE USED. CONTACT ARCHITECT IF
CLARIFICATION OR ADD'L. INFORMATION IS REQUIRED.
2. THE DRAWINGS ARE SCHEMATIC IN NATURE.
MODIFICATIONS IN
DUCTS, PIPING, CONDUIT AND WIRING MAY BE REQUIRED TO
ACCOMMODATE ACTUAL FIELD CONDITIONS.
3. DO NOT REPRODUCE DRAWINGS FOR SUBMITTALS.
SUBMITTALS WITH REPRODUCTIONS OF THESE DRAWINGS OR
PORTIONS OF THESE DRAWINGS WILL BE REJECTED AND
RETURNED WITHOUT APPROVAL OF ARCHITECT.
4. DIMENSIONS ARE AS FOLLOWS UNLESS NOTED OTHERWISE:
A) TO FACE OF STUD OF PARTITION OR EXTERIOR WALL.
B) TO CENTERLINE OF COLUMNS.
C) TO TOP OF STRUCTURAL FLOOR.
D) TO BOTTOM OF FINISHED CEILING.
E) TO FACE OF CONCRETE WALL
DEFINITIONS:
1. "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO
ACCURATELY LOCATE AND FINISH FACES IN THE SAME PLANE
WITHOUT ANY VISIBLE JOINTS OR SURFACE IRREGULARITIES.
2. "CLEAR" AS USED IN THESE DOCUMENTS SHALL MEAN
THAT THE CONDITION IS NOT ADJUSTABLE WITHOUT THE
APPROVAL OF THE ARCHITECT. CLEAR DIMENSIONS ARE
TYPICALLY TO FINISH FACE.
3. "MAXIMUM" OR "MAX" AS USED IN THESE DOCUMENTS
SHALLMEAN THAT THE CONDITION IS SLIGHTLY ADJUSTABLE
BUT MAY NOT VARY TO A DIMENSION OR QUANTITY GREATER
THAN THAT SHOWN WITHOUT APPROVAL OF THE ARCHITECT.
4. "MINIMUM" OR "MIN" AS USED IN THESE DOCUMENTS SHALL
MEAN THAT THE CONDITION IS SLIGHTLY ADJUSTABLE BUT
MAY NOT VARY TO A DIMENSION OR QUANTITY LESS THAN
THAT SHOWN WITHOUT APPROVAL OF THE ARCHITECT.
5. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN
THAT THE CONDITION OR DIMENSION IS THE SAME OR
REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.
6. "±" AS USED IN THESE DOCUMENTS SHALL MEAN THE
DIMENSION OR QUALITY IS SLIGHTLY ADJUSTABLE TO
ACCOMMODATE ACTUAL CONDITIONS.
MATERIALS:
1. ISOLATE ALL DISSIMILAR METAL MATERIALS WITH A
NON-METALLIC SEPARATOR.
2. MAINTAIN FIRE RESISTANCE RATING OF MEMBRANE
PENETRATIONS IN GARAGE WALLS.
3. ALL MATERIALS USED IN AIR DISTRIBUTION/RETURN SHALL
HAVE A FLAME- SPREAD RATING OF 25 AND SHALL BE
APPROVED BY LOCAL BUILDING CODE AUTHORITIES.
4. ALL MATERIALS USED IN FIRE-RATED ASSEMBLIES SHALL
BE APPROVED BY U.L. OR OTHER RECOGNIZED STANDARD
FOR USE IN SUCH ASSEMBLIES.
5. ALL STEEL PRODUCTS USED IN THE EXTERIOR WALLS
SHALL BE STAINLESS OR GALVANIZED. ALL EXTERIOR STEEL
SHALL BE GALVANIZED UNLESS NOTED OR SPECIFIED
OTHERWISE.
6. ALL SHEET METAL FLASHING SHALL ALLOW FOR THERMAL
MOVEMENT OF THE MATERIAL WITHOUT DEFLECTION AND
OILCANNING.
7. EXTERIOR WALL, BOTTOM SILL PLATES, SHALL BE
PRESSURE TREATED OR EQUAL, AND SHALL BEAR/EXTEND
MINIMUM 6 INCHES ABOVE FINISHED GRADE. (R317.1).
8. LUMBER SHALL BEAR AN APPROVED GRADING STAMP.
(R502.1)
9. LATH MUST BE CORROSION RESISTANT WITH A MINIMUM 1"
20 GA. GALVANIZED WIRE FABRIC LATH.
10. GYPSUM BOARD APPLIED TO A CEILING SHALL BE 1/2"
WHEN FRAMING MEMBERS ARE 16" O.C. OR 5/8" WHEN
FRAMING MEMBERS ARE 24"O.C. OR USE LABELED 1/2" SAG-
RESISTANT GYPSUM CEILING BOARD. TABLE R702.3.5(d).
11. EXTERIOR WALL PENETRATIONS BY PIPES, DUCTS, OR
CONDUITS SHALL BE CAULKED. (R302.4.1)
12. MINIMUM INSULATION SHALL BE: EXT. WALLS R-19,
CEILINGS R-38.
13. WALLS AND SOFFITS OF ENCLOSED USABLE SPACE
UNDER INTERIOR STAIRWAYS SHALL BE PROTECTED ON THE
ENCLOSED SIDE BY A MINIMUM 5/8" TYPE "X" GYPSUM BOARD.
14. EXTERIOR LOCATIONS SHALL NOT USE GYPSUM
WALLBOARD ON THE CEILING UNLESS THERE IS 1'-0" OF
PROTECTION BY A BEAM OR WALL OR HORIZONTAL
DISTANCE OF 10'-0". IT IS NECESSARY TO USE AN EXTERIOR
MATERIAL SUCH AS SOFFIT BOARD APPROVED FOR THE
LOCATION.
15. SHOWER AREA WALLS SHALL BE FINISHED WITH A
SMOOTH, HARD, NONABSORBENT SURFACE, SUCH AS
CERAMIC TILE, TO A HEIGHT OF NOT LESS THAN 6' ABOVE
DRAIN INLET. WATER RESISTANT GYPSUM WALLBOARD
SHALL NOT BE INSTALLED OVER A VAPOR RETARDER IN A
SHOWER OR TUB COMPARTMENT. CEMENT, FIBER-CEMENT
OR GLASS MAT GYPSUM BACKERS INSTALLED IN
ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS
SHALL BE USED AS BACKERS FOR WALL TILE IN TUB AND
SHOWER AREAS AND WALL PANELS IN SHOWER AREAS
(R702.4.2).
16. GLASS AT SHOWER ENCLOSURES SHALL BE TEMPERED
OR APPROVED EQUAL WITH A MINIMUM 1'-10" CLEAR
OPENING.
17. GLASS WITHIN HAZARDOUS AREAS; I.E.:
a. ALL GLASS WITHIN 1'-6" OF THE FLOOR
b. ALL GLASS WITHIN 5'-0" OF WATER (POOL)SHALL BE
SAFETY GLASS.
FIRE BLOCKING NOTES:
1. FIRE BLOCKING SHALL COMPLY WITH R602.8
2. AT CONCEALED SPACES OF STUD WALLS AND PARTITIONS,
INCLUDING FURRED SPACES, AT THE CEILING FLOOR LEVELS
AND AT MAX. 10'-0" INTERVALS BOTH HORIZONTAL & VERTICAL.
3. AT ALL INTERCONNECTIONS BETWEEN CONCEALED
VERTICAL AND HORIZONTAL SPACES SUCH AS SOFFITS,
DROPPED CEILINGS, COVE CEILINGS, AND TOPS OF FRAMED
COLUMNS.
4. IN CONCEALED SPACES BETWEEN STAIR STRINGERS, AT
THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS
ALONG AND IN LINE WITH THE RUN OF STAIRS, IF THE WALLS
UNDER THE STAIRS ARE UNFINISHED.
5. IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS,
FIREPLACES, AND SIMILAR OPENINGS WHICH AFFORD A
PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS, USE NON-
COMBUSTIBLE MATERIALS.
6. AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY
CHASES FOR FACTORY-BUILT CHIMNEYS.
7. WALLS HAVING PARALLEL OR STAGGERED STUDS FOR
SOUND CONTROL SHALL HAVE FIRE BLOCKS OF MINERAL
FIBER OR GLASS FIBER OR OTHER APPROVED NON-RIGID
MATERIAL.
8. THE INTEGRITY OF ALL FIRE BLOCKING, AND DRAFT STOPS,
SHALL BE MAINTAINED.
9. FLOOR-CEILING ASSEMBLIES WITH A CONCEALED SPACE IN
EXCESS OF 1,000 SQUARE FEET SHALL HAVE DRAFT STOPS
INSTALLED THAT DIVIDE THE CONCEALED SPACE INTO
APPROXIMATELY EQUAL AREAS.
STANDARD GENERAL NOTES : CONTINUED
14. ALL MECHANICAL EQUIPMENT SHALL BE SCREENED,
WHERE APPLICABLE, A MINIMUM OF 1'-0" HIGHER THAN THE
HIGHEST PORTION OF THE EQUIPMENT, AND SHALL MATCH
THE ADJACENT BUILDING MATERIAL.
15. PROVIDE A LISTED AND APPROVED BBQ UNIT, IF
APPLICABLE, INSTALLED PER THE MANUFACTURER'S
WRITTEN INSTRUCTIONS. BBQ UNIT SHALL CONFORM TO
ANSI Z21.58-1993 AND SHALL BE APPROVED BY A NATIONALLY
RECOGNIZED TESTING AGENCY.
16. INSTALL SELF-CLOSING AND SELF-LATCHING DEVICES ON
ALL DOORS WITH DIRECT ACCESS TO THE POOL WITH
RELEASE MECHANISM LOCATED A MIN. OF 4'-6" A.F.F.
17. POOL GATE: 5'-0" MIN. HGT. SWING AWAY FROM POOL.
PROVIDE SELF-CLOSING AND SELF-LATCHING DEVICE WITH
RELEASE MECHANISM LOCATED NO LESS THAN 4'-6" FROM
BOTTOM OF GATE ON POOL SIDE.
18. BEDROOM EGRESS WINDOWS SHALL HAVE A MINIMUM
NET CLEAR OPENABLE AREA OF 5.7 SQUARE FEET AND A
MINIMUM HEIGHT OF 2'-0" AND A MINIMUM WIDTH OF 1'-8".
SILL HEIGHT SHALL NOT BE MORE THAN 3'-8" ABOVE FINISH
FLOOR.
19. PROVIDE A MINIMUM OF 2'-6" CLEAR (WIDE) BETWEEN
FINISHED WALLS AT WATER CLOSET. THERE SHALL BE 1'-3"
CLEAR FROM THE CENTER LINE OF THE WATER CLOSET TO
THE CLOSEST FINISHED WALL. THERE SHALL BE 2'-0" CLEAR
IN FRONT OF THE WATER CLOSET (PER I.R.C. R307.1).
20. THE TOP OF HANDRAILS AND HANDRAIL EXTENSIONS
SHALL NOT BE PLACED LESS THAN 2'-10" NOR MORE THAN
3'-2" ABOVE LANDINGS AND THE NOSING OF TREADS. THE
HAND GRIP PORTION OF HANDRAILS SHALL NOT BE LESS
THAN 1 1/4" NOR MORE THAN 2" IN CROSS-SECTIONAL
DIMENSION OR THE SHAPE SHALL PROVIDE AN EQUIVALENT
GRIPPING SURFACE WITH NO SHARP CORNERS. HANDRAILS
PROJECTING FROM A WALL SHALL HAVE A SPACE OF NOT
LESS THAN 1 1/2" BETWEEN THE WALL AND THE HANDRAIL.
21. REQUIRED EXITS:
A) ALL EXITS TO BE OPENABLE FROM THE INSIDE WITHOUT
USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
(310.1.4).
B) MANUALLY OPERATED EDGE OR SURFACE MOUNTED
FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED AT A
DOOR OR THE ACTIVE LEAF OF A PAIR OF DOORS.
22. FRAME WALLS AT EACH END WITH 1/2" PLYWOOD
SHEATHING IN
ACCORDANCE WITH R602.10; AT LEAST EVERY 25'-0" LENGTH
WITH NOMINAL 1" BY 4" CONTINUOUS DIAGONAL BRACES LET
INTO TOP AND BOTTOM PLATES AND INTERVENING STUDS,
PLACED AT AN ANGLE NOT MORE THAN 60° FROM THE
HORIZONTAL AND ATTACHED TO THE FRAMING.
23. TOP OF FLUE SHALL BE 2'-0" MIN. ABOVE ANY ROOF
STRUCTURE WITHIN 10'-0" DISTANCE.
24. PROVIDE FIRE PROTECTION SPRINKLER SYSTEM. IFC 903
AMEND.
25. PROVIDE ROOF ATTIC VENTILATION UNLESS INSULATION
IS APPLIED DIRECTLY TO UNDERSIDE OF ROOF SHEATHING
OR THE DIMENSION IS 24 INCHES OR LESS BETWEEN THE
CEILING AND BOTTOM OF ROOF SHEATHING. (R806.1
AMENDED)
26. WINDOWS LOCATED MORE THAN 72" ABOVE FINISHED
GRADE SHALL HAVE THE LOWEST PART OF CLEAR OPENING
OF THE WINDOW TO BE MINIMUM 24 INCHES ABOVE THE
FLOOR IN WHICH IT SERVES. (R312.2.1).
28. DOOR LEADING INTO THE HOUSE FROM THE GARAGE
SHALL BE 20 MINUTE RATED, SELF CLOSING, SELF LATCHING.
(R302.5.1 AMENDED.).
HVAC GENERAL NOTES:
1. REGISTERS, DIFFUSERS AND GRILLES SHALL BE
MECHANICALLY FASTENED TO RIGID SUPPORTS OR
STRUCTURAL MEMBERS ON AT LEAST TWO OPPOSITE
SIDES IN ADDITION TO BEING CONNECTED TO THE
DUCTWORK THEY SERVE.
2. THE CLOTHES DRYER SHALL BE PROVIDED WITH A 4"
DIAMETER EXHAUST DUCT TO THE EXTERIOR AND SHALL
NOT EXCEED A TOTAL LENGTH OF 25'-0", UNLESS AN
ENGINEERED DUCT SYSTEM IS PROVIDED. THE DUCT
SHALL TERMINATE NOT LESS THAN 3'-0" FROM A PROPERTY
LINE OR FROM OPENINGS INTO A BUILDING.
3. SUBMIT TO ARCHITECT SHOP DRAWINGS OF ALL
MECHANICAL WORK PRIOR TO FABRICATION.
4. EXHAUST AIR FROM KITCHENS, BATHROOMS AND TOILET
ROOMS SHALL NOT BE RE-CIRCULATED WITHIN A
RESIDENCE OR TO ANOTHER DWELLING UNIT, SHALL NOT
DISCHARGE INTO AN ATTIC, AND/OR CRAWL SPACE AND
SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS .
M1507.2
5. SUPPLY AND RETURN DUCTS SHALL BE INSULATED TO A
MINIMUM R-8. DUCTS IN FLOOR TRUSSES SHALL BE
INSULATED TO MINIMUM R-6. (N1103.3.1).
6. DRYER EXHAUST DUCTS SHALL CONFORM TO THE
REQUIREMENTS OF SECTIONS M1502.4.5 AMENDED),
M1502.4.1 THRU M1502.4.6.
7. AT LEAST ONE THERMOSTAT SHALL BE PROVIDED FOR
EACH SEPARATE HEATING AND COOLING SYSTEM.
(N1103.1).
8. THE BUILDING SHALL BE PROVIDED WITH VENTILATION
THAT MEETS THE REQUIREMENTS OF SECTION M1507 OR
WITH OTHER APPROVED MEANS OF VENTILATION.
OUTDOOR AIR INTAKES AND EXHAUSTS SHALL HAVE
AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN THE
VENTILATION SYSTEM IS NOT OPERATING. (N1103.5).
9. DUCTS, AIR HANDLERS, AND FILTER BOXES SHALL BE
SEALED. JOINTS AND SEAMS SHALL COMPLY WITH SECTION
M1601.4.1, (N1103.2.2). DUCT TIGHTNESS SHALL BE VERIFIED
BY EITHER OF THE FOLLOWING.
1. POST-CONSTRUCTION TEST: TOTAL LEAKAGE SHALL BE
LESS OR EQUAL TO 4 CFM PER 100 SQUARE FEET OF
CONDITIONED FLOOR AREA WHEN TESTED AT A PRESSURE
DIFFERENTIAL OF 0.1 INCHES W.G. (25PA) ACROSS THE
ENTIRE SYSTEM, INCLUDING THE MANUFACTURERS AIR
HANDLER ENCLOSURE. ALL REGISTER BOOTS SHALL BE
TAPED OR OTHERWISE SEALED DURING TEST.
2. ROUGH-IN-TEST: TOTAL LEAKAGE SHALL BE LESS THEN
OR EQUAL TO 4 CFM OVER 100 FEET2 OF CONDITIONED
FLOOR AREA WHEN TESTED AT A PRESSURE DIFFERENTIAL
OF 0.1 INCHES W.G. (25PA) ACROSS THE SYSTEM,
INCLUDING THE MANUFACTURERS AIR HANDLER
ENCLOSURE. ALL REGISTERS SHALL BE TAPED OR
OTHERWISE SEALED DURING THE TEST. IF THE AIR
HANDLER IS NOT INSTALLED AT THE TIME OF THE TEST,
TOTAL LEAKAGE SHALL BE LESS THEN OR EQUAL TO 3 CFM
PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA
10. PROVIDE OUTSIDE COMBUSTION AIR TO ALL INDOOR
FIREPLACES, WITH AIR INTAKE NOT LOCATED HIGHER THAN
THE FIREBOX. (R1006.2)
ELECTRICAL GENERAL NOTES:
1. PROVIDE A WALL MOUNTED GFCI PROTECTED
RECEPTACLE OUTLET WITHIN 36" OF A BATHROOM OR
POWDER ROOM LAVATORY. (E3901.6).
2. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO
POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE
THAN 6'-0" MEASURED HORIZONTALLY, FROM AN OUTLET IN
THAT SPACE, INCLUDING ANY WALL SPACE 2'-0" OR MORE IN
WIDTH. (E3901).
3. BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY
AT LEAST ONE 20-AMPERE BRANCH CIRCUIT. SUCH CIRCUITS
SHALL HAVE NO OTHER OUTLETS PER (E3901.6, E3902.7)
4. PROVIDE A SEPARATE 20-AMPERE BRANCH CIRCUIT TO
THE LAUNDRY
5. PROVIDE A MIN. OF TWO 20-AMP SMALL APPLIANCE
BRANCH CIRCUITS FOR THE KITCHEN/DINING/BREAKFAST.
(E3703.2).
6. THE TWO OR MORE 20-AMPERE SMALL APPLIANCE BRANCH
CIRCUITS SHALL HAVE NO OTHER OUTLETS, EXCEPT THE
RECEPTACLE INSTALLED SOLELY FOR ELECTRIC SUPPLY TO
AN ELECTRICAL CLOCK IN THE KITCHEN/DINING/BREAKFAST
AREAS OR RECEPTACLES FOR SUPPLEMENTAL EQUIPMENT
AND LIGHTING FOR GAS-FIRED RANGES, OVENS, OR
COUNTER-MOUNTED UNITS.
7. RECEPTACLE OUTLETS FOR RANGES AND CLOTHES
DRYERS SHALL
BE A 3-POLE WITH GROUND TYPE. FOUR-WIRE, GROUNDING-
TYPE FLEXIBLE CORDS WILL BE REQUIRED FOR CONNECTION
OF RANGES AND CLOTHES DRYERS. THE BONDING JUMPER
SHALL NOT BE CONNECTED BETWEEN THE NEUTRAL
TERMINAL AND THE FRAME OF THE APPLIANCE. FLEXIBLE
CORDS SHALL BE USED ONLY WHERE THE...FLEXIBLE CORD
SUPPLYING AN APPLIANCE SHALL TERMINATE IN A
GROUNDING-TYPE ATTACHMENT PLUG.
8. PROVIDE IC-RATED RECESSED LIGHT FIXTURES INSTALLED
IN INSULATED CEILINGS.
9. PROVIDE AND INSTALL SINGLE PHASE ELECTRICAL
SERVICE AS NOTED ON ELECTRICAL DRAWINGS
10. SMOKE DETECTORS SHALL BE INSTALLED AT A POINT
CENTRALLY LOCATED IN THE HALLWAY OR AREA GIVING
ACCESS TO EACH SEPARATE SLEEPING AREA AND BE A
MINIMUM OF 3'-0" FROM ALL DUCT OPENINGS. EACH SMOKE
DETECTOR SHALL BE PERMANENTLY WIRED AND
INTERCONNECTED WITH BATTERY BACK-UP.
11. PERFORM ALL WORK IN ACCORDANCE WITH LOCAL AND
NATIONAL ELECTRICAL CODES.
12. ALL WIRE SHALL BE COPPER.
13. PROVIDE PRIMARY AND SECONDARY OVERCURRENT
PROTECTION FOR ALL 12-VOLT TRANSFORMERS WHERE
NOTED.
14. COORDINATE LOCATION AND INSTALLATION OF ALL
LIGHTING EQUIPMENT WITH ALL SUBCONTRACTORS (I.E.,
FRAMING, MECHANICAL, CABINETRY, ETC.). PRIOR TO
ROUGH-IN, PROVIDE AND INSTALL SOLID WOOD BLOCKING
FOR ALL FIXTURES IN DRYWALL CEILINGS FOR SECURE SOLID
ATTACHMENT OF DEVICES.
15. ALL SUBSTITUTIONS ARE TO BE APPROVED IN WRITING BY
THE OWNER.
16. PRIOR TO DRYWALL INSTALLATION, ALL ADJUSTABLE
FIXTURES ARE TO BE VERIFIED AFTER ROUGH-IN
INSTALLATION IN FIELD BY THE ARCHITECT AND OWNER.
17. ALL RECESSED TRIMS AND/OR TRIM RINGS ARE TO BE
PAINTED TO MATCH PAINT COLOR OR WOOD STAIN OF
CEILING IN ROOM.
18. ALL DEVICES (I.E., RECEPTACLES, PHONE JACKS, TV
JACKS, ETC.) AT NEW AND EXISTING LOCATIONS SHALL BE
DECORA STYLE. COLOR TO BE SELECTED. LOCATION OF ALL
DEVICES (ABOVE) SHALL BE VERIFIED IN FIELD BY ARCHITECT
AND INSTALLED PER CODE.19. OUTLET BOXES IN THE WALL
BETWEEN THE RESIDENCE AND GARAGE SHALL BE METAL
OR UL-APPROVED FIRE RESISTIVE PLASTIC. OUTLET BOXES
IN GARAGE CEILING SHALL BE METAL.
20. PRE-WIRE AUDIO/VISUAL, SOUND SYSTEM AND SECURITY
SYSTEM. LOCATIONS TO BE DETERMINED ON SITE BY
ARCHITECT, OWNER AND CONSULTANT.
21. PRE-WIRE FOR ROOF-MOUNTED SATELLITE TELEVISION
SYSTEM TO BE COORDINATED WITH OWNER/ARCHITECT.
22. ALL LAMPS MUST BE ELECTRIC. WHERE HALOGEN LAMPS
ARE SPECIFIED, USE MR-16 GE CONSTANT COLOR SERIES.
IMPROPER LAMPS TO BE REPLACED AT CONTRACTOR'S
EXPENSE.
ENERGY REQUIRMENTS:
1. A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY
INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS
OR A MINIMUM 75 PERCENT OF THE PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH -EFFICACY
LAMPS. (N1104.1)
2. RECESSED LUMINARIES INSTALLED IN THE BUILDING THERMAL
ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN
CONDITIONED AND UNCONDITIONED SPACES. ALL RECESSED
LUMINA SHALL BE IC-RATED AND LABELED AS HAVING AN AIR
LEAKAGE RATE NOT MORE THAN 2.0 CFM. ALL RECESSED
LUMINARIES SHALL BE SEALED WITH A GASKET OR CAULK
BETWEEN THE HOUSING AND THE INTERIOR WALL OR CEILING
COVERING.
3. THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND
VERIFIED AS HAVING AN AIR LEAKAGE RATE OF NOT EXCEEDING
5 AIR CHANGES PER HOUR. TESTING SHALL BE CONDUCTED
WITH A BLOWER DOOR AT A PRESSURE OF 0.2 INCHES W.G. (50
PASCALS). TESTING SHALL BE CONDUCTED BY AN APPROVED
THIRD PARTY. A WRITTEN REPORT OF THE RESULTS OF THE
TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST
AND PROVIDED TO THE BUILDING OFFICIAL. TESTING SHALL BE
PERFORMED AT ANY TIME AFTER THE CREATION OF ALL THE
PENETRATIONS OF THE THERMAL BUILDING ENVELOPE.
(N1102.4.1.2).
4. PROVIDE MINIMUM R-3 INSULATION ON HOT WATER PIPES.
(N1103.4)
5. THE HOT WATER CIRCULATING SYSTEM SHALL BE EQUIPPED
WITH AN AUTOMATIC OR READILY ACCESSIBLE MANUAL ON
SWITCH AND A TEMPERATURE SENSOR ACTIVATED SHUT-OFF
THAT CAN AUTOMATICALLY TURN OFF THE HOT WATER
CIRCULATING PUMP WHEN THE SET TEMPERATURE IS REACHED.
6.ENERGY COMPLIANCE SHALL BE DEMONSTRATED BY A
PASSING RESCHECK ENERGY COMPLIANCE SCORE. (N1101.2)
STANDARD GENERAL NOTES:
1. REFER TO CIVIL DRAWINGS FOR GRADING, DRAINAGE AND
ADDITIONAL TOPOGRAPHIC INFORMATION.
2. PROVIDE POSITIVE DRAINAGE AWAY FROM ALL
STRUCTURES 5% MINIMUM FOR THE FIRST 10'-0".
3. AN APPROVED GRADING & DRAINAGE PLAN SHALL BE KEPT
ON SITE AT ALL TIMES. DEVIATIONS FROM THE PLAN MUST
BE PRECEDED BY AN APPROVED REVISION.
4. REFER TO CIVIL PLAN FOR UTILITY INFORMATION.
CONTRACTOR TO PROVIDE SOIL COMPACTION TEST
RESULTS AS REQUIRED TO THE CITY ENGINEER'S OFFICE.
5. COORDINATE WITH ALL UTILITY COMPANIES FOR FINAL
LOCATION OF METERS, DEVICES, AND ROUTING.
CONTRACTOR TO PROVIDE ALL REQUIRED MATERIAL AND
LABOR FOR INSTALLATION OF ALL REQUIRED UTILITIES.
6. CONSTRUCTION AREA TO BE STAKED AND FENCED AT LINE
OF DISTURBANCE. NO DISTURBANCE OF THE DESERT WILL
BE ALLOWED BEYOND THIS LINE. SEE CIVIL DRAWINGS FOR
BUILDING ENVELOPE & N.O.S. CALCULATIONS AND
LOCATIONS.
7. MAINTAIN A MINIMUM DISTURBANCE OF SITE DURING
CONSTRUCTION.
8. DISPOSE OF EXCESS FILL DIRT PER THE OWNER'S
REQUEST.
9. VERIFY WITH THE OWNER THE DEMOLITION OR
RELOCATION OF ALL EXISTING LANDSCAPE MATERIALS AND
SITE ITEMS PRIOR TO COMMENCEMENT OF NEW
CONSTRUCTION.
10. FIELD VERIFY ALL SITE ITEMS AND THE COORDINATION OF
NEW CONSTRUCTION WITH ZONING SETBACK
REQUIREMENTS AND NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
11. VERIFY ALL GRADES IN FIELD.
12. SUBGRADE TO BE COMPACTED TO 95% OF MAXIMUM
DENSITY WITH 4" CONCRETE SLAB OVER 4" A.B.C.
13. WATERPROOF ALL ABOVEGROUND PLANTERS AND
RETAINING WALLS.
PLUMBING GENERAL NOTES:
1. PLUMBING FIXTURES SHALL COMPLY WITH THE FOLLOWING
CONSERVATION REQUIREMENTS: WATER CLOSETS- TANK
TYPE 1.6 GAL./FLUSH. SHOWER HEADS-2.5GAL./MINUTE.
FAUCETS-2.2GAL./MINUTE, PROVIDE AERATOR.(TABLE P2903.2.)
2. HOT WATER SHALL BE THE LEFT FITTING AT ALL FAUCETS.
3. PROVIDE AN EXPANSION TANK AT THE WATER HEATER IF A
BACKFLOW PREVENTER IS ON OR TO BE INSTALLED ON THE
WATER LINE OR AT THE METER.
4. SHOWERS AND TUB-SHOWER COMBINATIONS SHALL BE
PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE
PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE.
(P2708.4)
5. DOMESTIC DISHWASHING MACHINES CONNECTED TO A
DISPOSER SHALL HAVE THE DISCHARGE INSTALLED AS HIGH
AS POSSIBLE.
6. SOLDERS AND FLUX HAVING A LEAD CONTENT IN EXCESS
OF TWO TENTHS OF ONE PERCENT (.2%) SHALL NOT BE USED
IN THE INSTALLATION OR REPAIR OF ANY PLUMBING.
7. HOT WATER RECIRCULATION PUMPS. PROVIDE A HOT
WATER DEMAND CONTROLLED RECIRCULATION PUMP FOR
WATER HEATERS LOCATED MORE THAN 20 FEET FROM
FURTHEST FIXTURE SERVED. A MANUAL CONTROL OR
OCCUPANT SENSOR SWITCH SHALL OPERATE THE PUMP WITH
AN AUTOMATIC TEMPERATURE SENSOR SHUT-OFF.
MATERIALS: CONTINUED
18. MASONRY BED AND HEAD JOINTS SHALL BE 3/8 INCH-
THICK, THE THICKNESS OF THE BED JOINT OF THE STARTING
COURSE PLACED OVER FOUNDATIONS SHALL NOT BE LESS
THAN 1/4 INCH AND NOT MORE THAN 3/4 INCH. MORTAR
JOINT THICKNESS SHALL BE WITHIN THE FOLLOWING
TOLERANCES FROM THE SPECIFIED DIMENSIONS: 1. BED
JOINT: +1/8 INCH. 2. HEAD JOINT: 1/4 INCH + 3/8 INCH. 3.
COLLAR JOINTS: 1/4 INCH +3/8 INCH. (R606.3)
19. A MINIMUM 0.021" (26 GA.) CORROSION RESISTANT WEEP
SCREED WITH A MINIMUM OF 4" ABOVE THE GRADE OR 2"
ABOVE PAVED SURFACES SHALL BE A TYPE WHICH WILL
ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE
BUILDING. THE WEATHER RESISTIVE BARRIER AND EXTERIOR
LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT
FLANGE OF THE SCREED.
ABBREVIATIONS
A.B. ANCHOR BOLTS
A.B.C. AGGREGATE BASE COURSE
A.C. AIR CONDITIONING
AGGR. AGGREGATE
ALUM. ALUMINUM
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
B.O. BOTTOM OF
BD. BOARD
BITUM. BITUMINOUS
BLK. BLOCK
BLKG. BLOCKING
BM. BEAM
BRG. BEARING
C.J. CONTROL JOINT
C.T. CERAMIC TILE
CAB. CABINET
CATV. CABLE TV
CER. CERAMIC
COL. COLUMN
CLG. CEILING
CLR. CLEAR
C.M.U. CONCRETE MASONRY UNITS
CNTR. COUNTER
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
CPT. CARPET
CORR. CORRIDOR
DET. DETAIL
DIM. DIMENSION
DN. DOWN
D.P. DRAINAGE PIPE
DR. DOOR
DWG. DRAWING
EA. EACH
E.J. EXPANSION JOINT
EC. ELECTRICAL CONTRACTOR
ELEC. ELECTRICAL
ENCL. ENCLOSURE
EQ. EQUAL
EQUIP. EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EX.AGG. EXPOSED AGGREGATE
EXIST. EXISTING
EXP. EXPOSED
EXT. EXTERIOR
F.D. FLOOR DRAIN
F.F. FINISH FLOOR ELEVATION
FIN. FINISH (ED)
FLAH. FLASHING
FLR. FLOOR
FND. FOUNDATION
FNT. FOUNTAIN
FT. FOOT OR FEET
FTG. FOOTING
FURN. FURNISH (ED)
FURR. FURRING
GA. GAUGE
GALV. GALVANIZED
C.C.GENERAL CONTRACTOR
GL.GLASS
GND.GROUND
GSN.GENERAL STRUCTURAL NOTES
GYP.GYPSUM
H.B.HOSE BIBB
H.C.HOLLOW CORE
HDWD.HARDWOOD
HDWR.HARDWARE
HORIZ.HORIZONTAL
HR.HOUR
HT.HEIGHT
HWH.HOT WATER HEATER
I.A.INSIDE DIAMETER
IN.INCH
INSUL.INSULATION
INT.INTERIOR
INV.INVERT
JST.JOIST
JT.JOINT
KIT.KITCHEN
LAM.LAMINATE (D)
LAV.LAVATORY
LGTH.LENGTH
LIN.LINEAL
L.L.LIVE LOAD
L.W.C.LIGHT WEIGHT CONCRETE
MAS.MASONRY
MATL.MATERIAL
MAX.MAXIMUM
MECH.MECHANICAL
MEMB.MEMBRANE
MEP.MECH., ELECT. & PLUMB.
MFR.MANUFACTURER
MIN.MINIMUM
M.O.MASONRY OPENING
MISC.MISCELLANEOUS
MOD.MODULAR
MTL.METAL
MULL.MULLION
N.NORTH
N.I.C.NOT IN CONTRACT
NO. (#) NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O.A. OVER ALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.H. OVERHEAD
OPP. OPPOSITE
PERIM. PERIMETER
PERF. PERFORATED
PERM. PERMANENT
PERP. PERPENDICULAR
P.L. PROPERTY LINE
PLYWD. PLYWOOD
PLUMB. PLUMBING
PREFAB. PREFABRICATED
PREFIN. PREFINISHED
PROJ. PROJECT
PSI. POUNDS PER SQ. IN.
PT. PAINT
P.U.E. PUBLIC UTILITY EASEMENT
REBAR. REINFORCING BAR
REF. REFRIGERATOR
R.D. ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RE. REFER
REINF. REINFORCING
R.O. ROUGH OPENING
R.O.W. RIGHT OF WAY
RM. ROOM
REQD. REQUIRED
S.C. SOLID CORE
S.F. SQUARE FEET OR FOOT
SECT. SECTION
SHLV. SHELVE (S)
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
STD. STANDARD
STRU. STRUCTURAL
T.O. TOP OF
TELE.TELEPHONE
TEMP.TEMPORARY OR TEMPERED
THK.THICKNESS
TV.TELEVISION
TYP.TYPICAL
U.L.UNDERWRITERS LAB INC.
U.O.N.UNLESS OTHERWISE NOTED
VERT.VERTICAL
W/WITH
W.C.WATER CLOSET
WD.WOOD
W/O WITHOUT
WT.WEIGHT
STAIR AND HANDRAIL NOTES - IRC
STAIR WIDTH SHALL NOT BE LESS THAN 36" IN
CLEARWIDTH. (IRC-R311.7.1)
TREADS & RISERS THE MAX. RISER HEIGHT SHALL BE
7-3/4" (IRC-R311.7.5.1) AND THE MIN.
TREAD DEPTH SHALL BE 10". (IRC-
R311.7.5.2)
WINDER TREADS SHALL HAVE A MIN. TREAD DEPTH
OF 10" MEASURED AT A POINT 12"
FROM THE SIDE WHERE THE
TREADS ARE NARROWER. WINDER
TREADS SHALL HAVE A MIN. TREAD
DEPTH OF 6" AT ANY POINT. (IRC-
R311.7.5.2)
LANDING WIDTH SHALL NOT BE LESS THAN THE
STAIRWAY OR DOOR SERVED.
EVERY LANDING SHALL HAVE A
MIN. DIM. OF 36" MEASURED IN THE
DIRECTION OF TRAVEL. (IRC-
R311.7.6)
HANDRAIL HEIGHT SHALL BE A MIN. OF 34" AND A MAX.
OF 38" MEASURED VERTICALLY
FROM THE NOSING OF THE
TREADS, AND SHALL BE PROVIDED
ON AT LEAST ONE SIDE OF
STAIRWAYS. (IRC-R311.7.8.1)
CONTINUITY HANDRAILS FOR STAIRWAYS SHALL
BE CONTINUOUS FOR THE FULL
LENGTH OF THE FLIGHT, FROM A
POINT DIRECTLY ABOVE THE TOP
RISER OF THE FLIGHT TO A POINT
DIRECTLY ABOVE THE LOWEST
RISER OF THE FLIGHT. HANDRAIL
ENDS SHALL BE RETURNED OR
SHALL TERMINATE IN NEWEL
POSTS OR SAFETY TERMINALS.
HANDRAILS ADJACENT TO A WALL
SHALL HAVE A SPACE OF NOT LESS
THAN 1-1/2" BETWEEN THE WALL
AND THE HANDRAIL. (IRC-311.7.8.2)
STAIR AND HANDRAIL NOTES -IRC -CONTINUED
GUARDRAIL HEIGHT SHALL NOT BE LESS THAN 36". (IRC-
R312.1.2)
RAIL SPACING RAILS SHALL BE SPACED SO AS
NOT TO ALLOW PASSAGE OF A
SPHERE 4" IN DIA. (IRC-R312.1.3)
THE TRIANGULAR OPENING AT THE
OPEN SIDE OF THE STAIR, FORMED
BY THE RISER, TREAD AND
BOTTOM RAIL OF A GUARD, SHALL
NOT ALLOW THE PASSAGE OF A
SPHERE 6 INCHES IN DIAMETER.
(IRC-312.1.3 - 1)
GUARDS ON THE OPEN SIDES OF
THE STAIRS SHALL NOT HAVE
OPENINGS THAT ALLOW PASSAGE
OF A SPHERE 4-3/8 INCHES IN
DIAMETER. (IRC-312.1.3 - 2)
PLUMBING GENERAL NOTES -CONTINUED
8. WATER TREATMENT SYSTEMS- SHALL BE EQUIPPED WITH
AN AUTOMATIC OR READILY ACCESSIBLE MANUAL SHUTOFF
TO PREVENT CONTINUOUS FLOW WHEN NOT IN USE.
(N1103.5.1)
9. HOT WATER RECIRCULATION PUMPS. CIRCULATING HOT
WATER SYSTEMS SHALL BE PROVIDED WITH AN AUTOMATIC
OR READILY ACCESSIBLE MANUAL SWITCH THAT CAN TURN
OFF THE HOT WATER CIRCULATING PUMP WHEN THE SYSTEM
IS NOT IN USE. A MANUAL CONTROL OR OCCUPANT SENSOR
SWITCH SHALL OPERATE THE PUMP WITH AN AUTOMATIC
TEMPERATURE SENSOR SHUT -OFF (N1103.5.1).
10. WHERE A LISTED DECORATIVE APPLIANCE IS INSTALLED,
THE FIREPLACE DAMPER OPEN SHALL COMPLY WITH LISTED
DECORATIVE APPLIANCE MANUFACTURES INSTALLATION
INSTRUCTIONS. (G2434, G2435, G2453.1).
ELECTRICAL GENERAL NOTES -CONTINUED
23. ALL FIXTURES IN CLOTHES CLOSETS SHALL COMPLY WITH
(E9003.12)
REGARDING DISTANCES FROM STORAGE AREA AND TYPE OF
FIXTURE (COVERED REQUIRED).
24. ELECTRICAL BOXES WHICH SUPPORT CEILING FANS TO
BE UL LISTED FOR FAN SUPPORT PER (E4101.6)
25. INSTALL ALL RECEPTACLES CENTERED AT 1'-0" A.F.F. PER
CODE. OR, UNLESS NOTED OTHERWISE, INSTALL
HORIZONTALLY IN WOOD BASE.
26. ALL SWITCHES AND DIMMER DEVICES ARE TO BE
CENTERED AT 3'-4" A.F.F.
27. PROVIDE GFCI PROTECTION FOR RECEPTACLES WITHIN
6'-0" OF ALL LAVATORIES, SINKS AND BASINS.
28. PROVIDE GFCI PROTECTED RECEPTACLES AT ALL
EXTERIOR, BATHROOM AND GARAGE LOCATIONS.
29. PROVIDE A CONCRETE ENCASED GROUNDING
ELECTRODE OF NOT LESS THAN 20 FEET OF #4 BARE
COPPER. (E3608.1.2).
30. PROVIDE BONDING TO WATER PIPING, GAS AND METAL
BUILDING SYSTEMS.
(E3606.9, E3609.7)
31. ALL METAL PIPING SYSTEMS, METAL PARTS OF
ELECTRICAL EQUIPMENT, AND PUMP MOTORS ASSOCIATED
WITH THE HYDRO MASSAGE TUB SHALL BE BONDED
TOGETHER USING A COPPER BONDING JUMPER, INSULATED,
COVERED, OR BARE, NOT SMALLER THAN NO. 8 SOLID.
(E4209).
32. 15- AND 20- AMPERE RECEPTACLE INSTALLED IN
BATHROOMS, GARAGES AND GRADE-LEVEL PORTIONS OF
UNFINISHED ACCESSORY BUILDINGS USED FOR STORAGE OR
WORK AREAS, AND INSTALLED OUTDOORS SHALL HAVE GFCI
PROTECTION FOR PERSONNEL. (E3902.1-.3)
33. ELECTRICAL FIXTURES LOCATED IN DAMP OR WET
LOCATIONS SHALL BE "LISTED" TO BE SUITABLE FOR SUCH A
LOCATION. (E4003.9)
TANT COLOR SERIES. IMPROPER LAMPS TO BE REPLACED AT
CONTRACTOR'S EXPENSE.
34. ALL BRANCH CIRCUITS THAT SUPPLY 15- AND 20-AMPERE
OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS,
LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS AND
SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A
COMBINATION TYPE ARC-FAULT CIRCUIT INTERRUPTER (AFCI)
INSTALLED TO PROVIDE PROTECTION OF THE BRANCH
CIRCUIT. (E3902).
35. IN AREAS SPECIFIED IN SECTION E3901.1 15- AND 20-
AMPERE RECEPTACLES SHALL BE TAMPER-RESISTANT.
(E4002.14).
36. PROVIDE SMOKE ALARMS (R314).
37. APPROVED CARBON MONOXIDE ALARMS SHALL BE
INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN
THE IMMEDIATE VICINITY OF THE BEDROOMS IN DWELLING
UNITS WITHIN WHICH FUEL-FIRED APPLIANCES ARE
INSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED
GARAGES. (R315).
38. PROVIDE A SWITCH FOR THE STAIRWAY WHEN THERE
ARE 6 OR MORE RISERS. (R303.7.1).
REVISIONS
NO. DATE DESCRIPTION
03/22/22