HomeMy WebLinkAbout011_CoverA101
11
1
1
1
1
11
ELEVATION MARKER
SHEET
DETAIL NUMBER
ANNOTATION LEGEND
HEIGHT MARKER
VIEW NAME
SHEETS SCALE
DTL
VIEW TITLE
DIRECTION OF NORTH
(SHOWN ON PLANS ONLY)
LEVEL
ELEVATION
LEVEL MARKER
GRID
ROOM NAME
Rm #
ROOM TAG
EXIT EXIT SYMBOL
DIRECTION OF EXIT
# 1 #2
ROOF SLOPE SYMBOL
RUN
RISE
12
3.5
ALIGN SYMBOL
FLOOR FINISH TRANSITION
SYMBOL
222W DOOR TAG
1 REVISION TAG
##.#.1.A PARTITION TYPE TAG
1t WINDOW TAG
1
A101
SIM
DETAIL TAG
DETAIL NUMBER
SHEET NUMBER
1
A101
SIM
WALL SECTION TAG
DETAIL NUMBER
SHEET NUMBER
1
A101
SIM
BUILDING SECTION TAG
DETAIL NUMBER
SHEET NUMBER
1
A101
SIM
CENTERLINE SYMBOL
DIMENSION CLEAR BETWEEN
FINISH FACES
2'-5 1/8"
A101
1
SIM
CALLOUT TAG
0
GENERAL NOTES
1. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND
MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS.
2. DIMENSIONS TAKE PRECEDENCE OVER DRAWING: DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATIONS. THE ARCHITECT SHALL BE NOTIFIED OF
ANY DISCREPANCY PRIOR TO CONTINUING WITH WORK.
3. GENERAL CONTRACTOR SHALL KEEP THE CONSTRUCTION SITE IN A BROOM CLEAN CONDITION AT ALL TIMES DURING THE PROJECT
4. THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS HE OR SHE MAY DISCOVER. THE CONTRACTOR IS
RESPONSIBLE FOR CORRECTING ANY ERROR AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE
ARCHITECT. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY THE ARCHITECT.
5. ALL REQUIRED CITY AND/OR COUNTY LICENSE SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL TRADE. CONTRACTOR SHALL OBTAIN ALL PERMITS
AND PAY ALL FEES REQUIRED BY LOCAL LAWS, ORDINANCES AND REGULATIONS PERTAINING TO THIS WORK.
6. SHOP DRAWINGS ARE TO BE CHECKED AND APPROVED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTING FOR ARCHITECT/ENGINEER REVIEW.
GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF ALL DIMENSIONS AND DETAILS FOR EACH SUBCONTRACTOR. THE
ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT. THE ARCHITECT'S REVIEW
OF A SEPARATE ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT AND TO
PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY
DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK.
8. CITY APPROVED PLANS SHALL BE KEPT IN A SECURE PLACE AND SHALL NOT BE USED BY WORKERS. THE CONTRACTOR SHALL BE RESPONSIBLE THAT
ALL SUBCONTRACTORS' CONSTRUCTION SETS REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE
COMPLETE SET OF STAMPED CITY APPROVED PLANS WITH ALL REVISIONS, ADDENDUMS, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES. THESE
ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT AND MUST BE MADE AVAILABLE TO BUILDING AND FIRE INSPECTIONS FOR REFERENCE
DURING CONSTRUCTION.
9. THE CONTRACTOR SHALL SCHEDULE AND COORDINATE ALL REQUIRED INSPECTIONS FROM THE APPROPRIATE REGULATORY AGENCIES.
10. CONTRACTOR SHALL SUBMIT COPIES OF INSPECTION REPORTS FOR ALL REQUIRED INSPECTIONS TO THE ARCHITECT AND ENGINEERS.
11. THE CONTRACTOR TO PROVIDE TEMPORARY FENCING AND ENCLOSURES AROUND THE SITE AND CONSTRUCTION STAGING AREA FOR THE PROTECTION
OF THE OTHER SITE OCCUPANTS AND PUBLIC SAFETY.
12. THE CONTRACTOR TO CONTROL ALL CONSTRUCTION ACCESS DELIVERIES AND PROTECT ADJACENT SITE ELEMENTS INCLUDING ROADS, DRIVES, CURBS,
SIDEWALKS, ETC. DURING THE CONSTRUCTION PHASE.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL JOB COMPLETION.
14. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES.
15. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS AND METHODS AND SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF ANY
CONSTRUCTION UNTIL ALL FINAL LATERAL AND VERTICAL LOAD CARRYING SYSTEMS ARE COMPLETED.
16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FAULTY, IMPROPER, OR INFERIOR MATERIALS OR WORKMANSHIP
WHICH SHALL APPEAR WITHIN ONE (1) YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT.
17. CONTRACTOR TO PROVIDE BACKING OR BLOCKING AS REQUIRED FOR MOUNTING ALL WALL MOUNTED SHELVES, EQUIPMENT, ACCESSORIES, CABINETS,
ETC.
18. CONTRACTOR TO PROTECT ALL TREES AND ROOTS NOT SLATED FOR REMOVAL DURING CONSTRUCTION.
19. GENERAL CONTRACTOR RESPONSIBLE FOR MAINTENANCE OF STAGING AREA AND TO ENSURE THAT MATERIALS DELIVERY AND STORAGE DOES NOT
INTERFERE WITH DAILY OPERATION OF ADJACENT PROPERTIES OR PUBLIC RIGHT OF WAY
20. GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION STAKING AND BUILDING LAYOUT.
21. ALL DIMENSIONS ARE TAKEN FROM F.O. STUD OR COLUMN CL. U.N.O.
22. ALL DOOR/WINDOW DIMENSIONS ARE TO WINDOW CL. IF NO CL DIMENSION IS SHOWN FOR A PARTICULAR DOOR/WINDOW TYPE, SEE SCHEDULE AND
DOOR/WINDOW DETAILS FOR TYPICAL INSTALLATION DETAIL.
23. GENERAL NOTES SHALL NOT SUBSTITUTE FOR SPECIFICATIONS. CONFLICTS BETWEEN THE TWO SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S
NOTICE OR THE STRICTER CRITERIA SHALL BE USED.
24. THIS PROJECT HAS BEEN DESIGNED AND DEVELOPED TO COMPLY WITH ALL LOCAL, STATE, AND FEDERAL ADA REQUIREMENTS.
25. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIRE SAFEING AND JOINT SEALANTS OF BUILDING PENETRATIONS THAT OCCUR DURING CONSTRUCTION.
THE RIDGE LOT 6
4204 RAVALLI STREET | BOZEMAN MT 59718
RIDGE ATHLETIC CLUB SUB, S10, T02 S, R05 E, LOT 7A, PLAT J-465-A
DEVELOPMENT REVIEW
11/22/2021
AB
ACI
ACP
AD
ADDT’L
ADJ
AFF
AFG
AHU
ALT
ALUM
ARCH
ASPH
ASSY
ASTM
ANCHOR BOLT
AMERICAN CONCRETE INSTITUTE
ACOUSTIC CEILING PANEL
AREA DRAIN
ADDITIONAL
AJUSTABLE
ABOVE FINISHED FLOOR
ABOVE FINAL GRADE
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ARCHITECT, ARCHITECTURAL
ASPHALT
ASSEMBLY
AMERICAN SOCIETY OF TESTING
& MATERIALS
A
B
BD
BG
BLDG
BLKG
BM
B.O.
BOT
BRK
BR&S
BSMT
BTWN
BOARD
BELOW GRADE
BUILDING
BLOCKING
BEAM
BOTTOM OF
BOTTOM
BRICK
BACKER ROD AND SEALANT
BASEMENT
BETWEEN
CABT
CT
CIP
C/L or CL
CJ
CLG
CLR
CMU
C.O.
COL
COMM
CONC
CONFIG
CONST
CONT
CONTR
COORD
CORR
CPT
CABINET
CERAMIC TILE
CAST-IN-PLACE
CENTER LINE
CONTROL JOINT
CEILING
CLEAR
CONCRETE MASONRY
UNIT
CLEANOUT
COLUMN
COMMUNICATIONS
CONCRETE
CONFIGUATION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
COORDINATE
CORRIDOR
CARPET
C
D
DBL
DEFS
DN
DET
DF
DIA
DIM
DP
DR
DS
DTL
DW
DWG
DOUBLE
DIRECT-APPLIED EXTERIOR FINISH SYSTEM
DOWN
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIMENSION
DAMPERPROOFING
DOOR
DOWNSPOUT
DETAIL
DISHWASHER
DRAWING
E
EA
EIFS
EJ
ELEC
ELEV or EL
ENCL
EPS
EQ
EQUIP
EXIST or (E)
EXT
EACH
EXTERIOR INSULATION FINISH
SYSTEM
EXPANSION JOINT
ELECTRIC/ELECTRICAL
ELEVATION
ENCLOSURE
EXPANDED POLYSTYRENE INSUL BD
EQUAL
EQUIPMENT
EXISTING
F EXTERIOR
FD
FDN
FE
FEC
FF
FIN
FL or FLR
FLRG
FDTN
F.O.
FOS
FR
FRM
FRMG
FRP
FT
FTG
FTN
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FINISHED FLOOR
FINISHED
FLOOR
FLOORING
FOUNDATION
FACE OF
FACE OF STUD
FIRE RATED
FRAME/FRAMED
FRAMING
FIBERGLASS REINFORCED PLASTIC
FOOT/FEET
FOOTING
FOUNTAIN
G
GA
GALV.
GFCI
GL
GLB
GLZ
GWB
GWB-P
GAUGE
GALVANIZED
GROUND FAULT CIRCUIT INTERRUPTER
GLUE LAMINATED
GLU LAM BEAM
GLASS/GLAZING
GYMPSUM WALL BOARD
GYPSUM WALL BOARD PAINTED
H
H
HB
HC
HDWRE
HDR
HM
HORIZ
HR
HS
HT
HVAC
HVY
HWH
HIGH
HOSE BIB
HANDICAPPED ACCESSIBLE
HARDWARE
HEADER
HOLLOW METAL
HORIZONTAL
HANDRAIL
HOLLOW STEEL
HEIGHT
HEATING, VENTILATION, & AIR COND.
HEAVY
HOT WATER HEATER
I
IGU
INCL
INDIC.
INSUL
INT
INSULATED GLASS UNIT
INCLUDE, INCLUDING
INDICATE(D)
INSULATION
INTERIOR
J
JC
JST
JANITOR CLOSET
JOIST
L
L
LAV
LOC
LT
LONG/LENGTH
LAVATORY
LOCATION/S
LIGHT
M
MAS
MAX
MECH
MEZZ
MFR
MIN
MIR
MISC
MLWK
MO
MTD
MTL
MASONRY
MAXIMUM
MECHANICAL
MEZZANINE
MANUFACTURER
MINIMUM
MIRRO
MISCELLANEOUS
MILLWORK
MASONRY OPENING
MOUNTED
METAL
N
(N)
NO or #
NIC
NTS
NEW
NUMBER
NOT IN CONTRACT
NOT TO SCALE
O
OC
O.D.
OH
OP
OWSJ
ON CENTER
OUTER DIMENSION
OVERHEAD
OPERABLE
OPEN WEB STEEL JOIST
P
PART’N
PC
PERF
PERP
PL
P-LAM
PLYWD
PMR
PTG/PTD
PNL
PREFAB
PREFIN
PT
PTD
PARTITION
PRECAST
PERFORATED
PERPENDICULAR
PLATE/PROPERTY LINE
PLASTIC LAMINATE
PLYWOOD
PER MNFR. RECOMMENDATION
PAINTING / PAINTED
PANEL
PREFABRICATED
PREFINISISHED
PRESSURE TREATED
PAPER TOWEL DISPENSER
R
RA
RAD
RD
REF
REFL
REFR
REINF
REQD
REQMT
RESIL
RET
REV
RFG
RI
RM
RO
RETURN AIR
RADIUS
ROOF DRAIN
REFERENCE
REFLECTIVE
REFRIDGERATOR
REINFORCING
REQUIRED
REQUIREMENT
RESILIENT
RETAINING
REVISION
ROOFING
RIGID
INSULATION
ROOM
S ROUGH OPENING
SAM
SCHED
SD
SECT
SF
SG
SHLVS
SHWR
SIM
SJ
SM
SMD
SPEC
SQ
SS
SSD
STL
STD
STOR
STRS
STRUCT
SURF
SUSP
SUBFLR
SV
SELF-ADHERING MEMBRANE
SCHEDULE
SOAP DISPENSER
SECTION
SQUARE FOOT
SAFETY GLAZING
SHELVES
SHOWER
SIMILAR
SEISMIC JOINT
SHEET METAL
SEE MECHANICAL DRAWINGS
SPECIFICATION
SQUARE
STAINLESS STEEL
SEE STRUCTURAL DRAWINGS
STEEL
STANDARD
STORAGE
STAIRS
STRUCTURE/STRUCTURAL
SURFACE
SUSPENDED, SUSPENSION
SUBFLOOR
SHEET VINYL
T
T&G
TEL
TERR
TG
THK
T.O.
TR
TS
TX
TYP
TONGUE & GROOVE
TELEPHONE
TERRAZZO
TEMPERED GLASS
THICK
TOP OF
TREAD
TUBULAR STEEL
TEXTURED
TYPICAL
UNFIN
UNO
UTIL
U
UNFINISHED
UNLESS NOTED OTHERWISE
UTILITY
V
VB
VCT
VCB
V/VERT
VFY
VIF
VR
VAPOR BARRIER
VINYL COMPOSTION TILE
VINYL COVE BASE
VERTICAL
VERIFY
VERIFY IN FIELD
VAPOR RETARDER
W
W
W/
WC
WD
WDW
WF
WP
WRB
WSP
WT
WWF
WIDE
WITH
WATER CLOSET
WOOD
WINDOW
WIDE FLANGE
WATERPROOF, WATER PROOFING
WEATHER RESISTIVE BARRIER
WET STANDPIPE
WEIGHT
WELDED WIRE FABRIC
Y
YD YARD
PROJECT TEAM
BUILDING OWNER:
BLACK DIRT, LLC- ANDY ROWE
2320 W MAIN ST, SUITE 6
BOZEMAN, MONTANA 59718
(406) 920-1029
ANDY@ALPENGLOWBUILD.COM
GENERAL CONTRACTOR
CONTRACTOR NAME
CONTRACTOR ADDRESS
BOZEMAN, MT 59718
(XXX) XXX-XXXX
INDIVIDUAL'S NAME
EMAIL
ARCHITECT:
45 ARCHITECTURE
1216 W LINCOLN ST, SUITE D
BOZEMAN, MONTANA 59715
(406) 577-2345
JEFF LUSIN, PRINCIPAL-IN-CHARGE
JLUSIN@45ARCH.COM
MARTINA PARRISH, PROJECT MANAGER
MPARRISH@45ARCH.COM
CIVIL ENGINEER:
HEADWATERS ENGINEERING, INC.
190 NORTHSTAR LANE
BOZEMAN, MONTANA 59718
(406) 581-5730
JEREMY MAY
JMAY@HEADWATERSMT.NET
STRUCTURAL ENGINEER:
JOHNSON STRUCTURAL ENGINEERING, INC
152 WEST SHORT ST
BOZEMAN, MONTANA 59715
406-585-2939
TRACY THOMAS
THOMASANNTRACY@GMAIL.COM
LANDSCAPE ARCHITECT:
CASHMAN'S NURSERY & LANDSCAPING
2055 SPRINGHILL RD
BOZEMAN, MONTANA 59718
406-587-3406, 1
MATTHEW KELLER
DESIGN3@CAHSMANNURSERY.COM
SHEET # SHEET NAME 11-08-2021 REVISION
ARCHITECTURAL
A7.02 ELEVATOR DETAILS
ARCHITECTURAL SITE
A0.00 ARCHITECTURAL SITE PLAN ■
GENERAL
G0.00 COVER ■
LANDSCAPE
I-1 IRRIGATION ■
L-1 LANDSCAPE ■
CIVIL
C-1 GENERAL CIVIL PLAN ■
C-2 UTILITY PLAN ■
C-3 GRADING AND DRAINAGE PLAN ■
C-4 SITE PLAN ■
C-5 CIVIL DETAILS ■
ARCHITECTURAL
A1.00 LEVEL 1 PLAN ■
A1.01 LEVEL 2 PLAN ■
A1.05 ROOF PLAN ■
A2.00 BUILDING ELEVATIONS ■
A2.01 BUILDING ELEVATIONS (CONT'D) ■
A2.02 RENDERED BUILDING ELEVATIONS ■
A2.03 RENDERED BUILDING ELEVATIONS
(CONT'D)
■
A3.00 BUILDING SECTIONS ■
A6.00 DOOR AND WINDOW INFORMATION ■
A6.01 STOREFRONT INFORMATION ■
ELECTRICAL
ES1.01 LIGHTING PHOTOMETRICS PLAN ■
VICINITY MAP
Date:
45 Arch Project Number:
Sheet Name
ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.
Consultant
NOT FOR
CONSTRUCTION
1216 W Lincoln Street, Suite D
Bozeman, Montana 59715
(406) 577-2345
www.45arch.com
REVISIONS
11/23/2021 12:44:38 PM
G0.00
COVER
THE PEAKS
NOVEMBER 8, 2021
21011
4204 RAVALLI ST
DA LAND COMPANY
NO. DESCRIPTION DATE
PARCEL AND SITE COVERAGE INFORMATION
• PROJECT SUMMARY
• NEW CONSTRUCTION 2-STORY BUILDING ON EMPTY PUD PAD SITE, WITH OFFICE/COMMERCIAL AT LEVEL 1 AND RESIDENTIAL AT LEVEL 2.
• ZONING
• RESIDENTIAL OFFICE (R-O)
• PARCEL SIZE
• .34 ACRES, 14,967 SF
• PARKING REQUIREMENTS (DEVELOPED AND BUILT BY PUD MASTER DEVELOPER)
• REQUIRED PARKING CALCULATION:
COMMERCIAL USE LEVEL 1: 7,560 GSF X 85% (NET) = 6,456 SF / 250 = 26 REQUIRED PSACES
RESIDENTIAL USE LEVEL 2: (6) 2-BEDROOM UNITS = 12 REQUIRED PARKING SPACES
GRAND TOTAL REQUIRED PARKING: 38 SPACES
• PARKING PROVIDED IN PUD: 41 SPACES
• DENSITY AND FLOOR AREA RATIO BREAKDOWN
• MAX LOT COVERAGE IS 60% = 8,980 GSF
• MAX FAR = 1.5:1, WHICH IS 22,450 GSF
• NET RESIDENTIAL DENSITY
6 DU / (.34 ACRES - .08 ACRES OF OPEN SPACE) = 23, > MIN. 6 PER TABLE 38.320.030C
• BUILDING AREA
LEVEL 1: 7,560 GSF < MAX LOT COVERAGE 8,980 GSF
LEVEL 2: 7,560 GSF
GRAND TOTAL PROJECT: 15,120 GSF < MAX FAR 22,450 GSF
• DRIVEWAY, CIRCULATION, AND PARKING AREAS
• 0 SF, PUD PAD SITE
• SEMIPUBLIC LAND AREAS, OPEN SPACE
• OPEN SPACE REQUIRED: 150 SF PER DWELLING UNIT X 6 UNITS = 900 SF
• OPEN SPACE PROVIDED: 900 SF, 50% PROVIDED IN BALCONIES ON NORTH UNITS
• OPEN SPACE REQUIRED BY THE PUD: 2,994 SF
• GRAND TOTAL OPEN SPACE PROVIDED: 3,444 SF, WITHIN SETBACKS
• LANDSCAPE AREAS
• PARKLAND
• .10 ACRES, (PROVIDED BY PROPOSED CASH IN LIEU OF LAND DEDICATION)
• .1 ACRE X 43,560 SF/ACRE X $2.07 = $901.69 OWED FOR C-I-L
• PUBLIC STREET RIGHT OF WAY
• 0 SF, PUD PAD SITE