HomeMy WebLinkAbout005_E0.0.0_ELECTRICALCOVERSHEET_08272021ELECTRICAL ABBREVIATION KEY AFF ABOVE FINISHED FLOOR N.C.NORMALLY CLOSED NIC NOT IN CONTRACT N.O.NORMALLY OPEN SV SOLENOID VALVE ABBR:DESCRIPTION: TYP TYPICAL C CONDUIT UNO UNLESS NOTED OTHERWISE GFI GROUND FAULT INTERRUPTER GAP GENERATOR ANNUNCIATOR PANEL NORMAL BRANCH LUMINAIRE CRITICAL BRANCH LUMINAIRE EMERGENCY LIFE SAFETY BRANCH LUMINAIRE LUMINAIRE SYMBOL KEY SYMBOL:DESCRIPTION: SW-1P 26 09 33 SWITCH -SINGLE POLE SW-2P 26 09 33 SWITCH -TWO POLE2 SW-3W 26 09 33 SWITCH -THREE WAY3 SW-3W-EM 26 09 33 SWITCH -THREE WAY -EMERGENCY3E SW-1P-WP 26 09 33 SWITCH -WEATHERPROOFW SW-1P-LH 26 09 33 SWITCH -LIGHTED HANDLEL SW-1P-M 26 09 33 SWITCH -MOMENTARY CONTACTM OC SW-OC-D OCCUPANCY SENSOR -DUAL TECHNOLOGYD ALCR ALCR20 AUTOMATIC LOAD CONTROL RELAY BCELTS BCELTS BRANCH CIRCUIT EMERGENCY LIGHTING TRANSFER SWITCH 20A LS SW-LS DAYLIGHT LEVEL SENSOR LS SW-LS-3Z DAYLIGHT LEVEL SENSOR -3 ZONE3 LS SW-LS-D DAYLIGHT LEVEL SENSOR -1 ZONE DIMMINGD LS SW-LS-D-3Z DAYLIGHT LEVEL SENSOR -3 ZONE DIMMING3D 26 09 33 26 09 33 26 09 33 SW-1P-K SWITCH -SINGLE POLE -KEY LOCK 26 09 33K SW-2P-K SWITCH -TWO POLE -KEY LOCK K2 SW-LS-PC PHOTOCELL26 09 33PC 26 09 33 MD-SD-#26 28 16 MOBILE DIAGNOSTICS SERVICE DISCONNECT. REFER TO DISC/STA SCHEDULE CB-#26 28 16 CIRCUIT BREAKER -SURFACE MOUNTED. REFER TO DISC/STA SCHEDULE CB-#26 28 16 CIRCUIT BREAKER -FLUSH MOUNTED. REFER TO DISC/STA SCHEDULE DS-#/FDS-#/DSS-#26 28 16 DISCONNECT. REFER TO DISC/STA SCHEDULE SW-OC-D-W OCCUPANCY SENSOR -DUAL TECHNOLOGY -WALL MOUNTEDD26 09 33OC 26 09 33 26 09 33 26 09 33 26 09 33 SW-D3-LED DIMMER -LED -3-WAYD326 09 33 ELECTRICAL SYMBOL LIST SYMBOL:TAG:SPEC SECTION:DESCRIPTION: FA-LA 26 09 16 LAMP ANNUNCIATORLA SW-DCS DIMMER CONTROL STATION26 09 33#B SW-LCS DIMMER CONTROL STATION WITH FADERS26 09 33 TC-#TIME SWITCH 26 09 33TC RI-TV 26 05 33 TV ANTENNA OUTLET ROUGH-INTV FB-# or PT-#26 27 26 FLOOR BOX or POKE THROUGH JB 26 05 33 JUNCTION BOXJ J ECONN 26 05 33 ELECTRICAL CONNECTIONE E WW-#26 05 35 ELECTRICAL WIREWAY w/ DEVICES SHOWN WM-#26 05 35 MULTI OUTLET SYSTEM RI-TECH-C 26 05 33 TECHNOLOGY ROUGH-IN, CEILINGRI RI-TECH-W 26 05 33 TECHNOLOGY ROUGH-IN, WALL PHONE PANEL '###'26 24 16 PANELBOARD -SURFACE MOUNT PANEL '###'26 24 16 PANELBOARD -RECESS MOUNT IPC-#26 24 22 INTEGRATED POWER CENTER IPP-#26 24 21 ISOLATED POWER PANEL RIM 26 24 21 REMOTE LINE ISOLATION MONITORRIM MG 26 24 21 MASTER GROUND STATION MODULEMG PM 26 24 21 OPERATING ROOM POWER MODULEPM GB 26 05 26 GROUND BUSGB IBT 26 05 26 INTERSYSTEM BONDING TERMINATIONIBT PB PB 26 09 16 MOMENTARY PUSHBUTTON OPERATOR ES ES 26 09 16 EMERGENCY STOP, N.C. CONTACT EPO 26 09 16 EMERGENCY STOP, N.O. CONTACTEPO CPC 26 09 16 CONTROL POWER CABINETCPC MX-#/MS-# /CB-#/CS-# 26 24 19 MANUAL SWITCH / STARTER / COMBINATION STARTER/ CIRCUIT BREAKER. REFER TO DISC/STA SCHEDULE LCS-#26 09 33 LIGHTING CONTROL STATION #B#F ELECTRICAL SYMBOL LIST SYMBOL: TAG: SPEC SECTION:DESCRIPTION: MPC-#26 24 23 PACKAGED POWER CENTER DEM DEM ENERGY METER26 09 13 PQM PQM POWER QUALITY METER26 09 13 TR-#/DTR-#26 22 00 TRANSFORMER. REFER TO TRANSFORMER SCHEDULE SW-OD DIMMER -WALL DIMMER OCCUPANCY SENSORO26 09 33 SW WALL CONTROL STATION26 09 33SW SW-LV 26 09 33 CENTRAL CONTROL -STATIONLV LCD SW-LCD LIGHTING CONTROL LCD STATION26 09 33 NLC SW-NLC NURSE CALL LIGHTING CONTOLLER26 09 33 RAS 26 24 21 REMOTE ANNUNCIATOR STATIONRAS 26 32 13 LINEAR LUMINAIRES TROFFER WALL SCONCE LUMINAIRE DOWNLIGHT LUMINAIRE AIMABLE OR WALL WASH LUMINAIRE INDUSTRIAL LUMINAIRE POLE MOUNTED LUMINAIRE SINGLE FACE EXIT SIGN DOUBLE FACE EXIT SIGN EMERGENCY UNIT WALL BRACKET LUMINAIRE ELECTRICAL SYMBOL LIST SYMBOL: TAG: SPEC SECTION:DESCRIPTION: WALL/CEILING EMERGENCY EXIT SIGN REC-DUP-GFI-R 26 27 26 GROUND FAULT DEVICEG REC-TAMP 26 27 26 DUPLEX RECEPTACLE, TAMPER RESISTANT, 125V REC-TAMP-GFI 26 27 26 GFI DUPLEX RECEPTACLE, TAMPER RESISTANT, 125V REC-TAMP-QUAD 26 27 26 QUAD RECEPTACLE, TAMPER RESISTANT, 125V REC-ISO- SUR-QUAD 26 27 26 ISOLATED GROUND QUAD RECEPTACLE WITH SURGE SUPPRESSION, 125V REC-DUP 26 27 26 DUPLEX RECEPTACLE, 125V REC-DUP-XP 26 27 26 DUPLEX RECEPTACLE, EXPLOSION PROOF, 125V REC-DUP-GFI 26 27 26 DUPLEX GFI RECEPTACLE, 125V REC-DUP-WP 26 27 26 DUPLEX GFI WEATHERPROOF RECEPTACLE 125VW REC-ISO 26 27 26 ISOLATED GROUND RECEPTACLE, 125V REC-ISO-SUR 26 27 26 ISOLATED GROUND RECEPTACLE WITH SURGE SUPPRESSION, 125V REC-QUAD 26 27 26 QUAD RECEPTACLE, 125V REC-QUAD-GFI 26 27 26 QUAD GFI RECEPTACLE, 125V REC-SIM-520R 26 27 26 SIMPLEX RECEPTACLE, 125V REC-SIM-530R 26 27 26 RECEPTACLE, 125V REC-SIM-620R 26 27 26 RECEPTACLE, 6-20R, 250V REC-SIM-630R 26 27 26 RECEPTACLE, 6-30R, 250V REC-SIM-650R 26 27 26 RECEPTACLE, 6-50R, 250V REC-SIM-720R 26 27 26 RECEPTACLE, 7-20R, 277V REC-SIM-730R 26 27 26 RECEPTACLE, 7-30R, 277V REC-SIM-750R 26 27 26 RECEPTACLE, 7-50R, 277V REC-SIM-1420R 26 27 26 RECEPTACLE, 14-20R, 125/250V REC-SIM-1430R 26 27 26 RECEPTACLE, 14-30R, 125/250V REC-SIM-1450R 26 27 26 RECEPTACLE, 14-50R, 125/250V REC-SIM-1460R 26 27 26 RECEPTACLE, 14-60R, 125/250V REC-SIM-1520R 26 27 26 RECEPTACLE, 15-20R, 250V, 3PH REC-SIM-1530R 26 27 26 RECEPTACLE, 15-30R, 250V, 3PH REC-SIM-1550R 26 27 26 RECEPTACLE, 15-50R, 250V, 3PH REC-SIM-XP 26 27 26 RECEPTACLE, EXPLOSION PROOF, 125V ELECTRICAL SYMBOL LIST SYMBOL: TAG: SPEC SECTION:DESCRIPTION: REC-USB 26 27 26 DUPLEX RECEPTACLE, USB CHARGING X S S U X DUPLEX RECEPTACLE CONTROLLED BY OCCUPANCY O REC-DUP-O 26 27 26 REC-PED-QUAD 26 05 33 RECEPTACLE -PEDESTAL STYLE REC-DUP-PED 26 05 33 RECEPTACLE -PEDESTAL STYLE REC-ARC 26 27 26 REC-SIM-550R 26 27 26 RECEPTACLE 125V, 50A, 125V REC-SIM-1560R 26 27 26 RECEPTACLE, 15-60R, 250V, 3PH REC-QUAD-USB 26 27 26 QUAD RECEPTACLE, USB 125V U REC-QUAD-WP 26 27 26 QUAD GFI WEATHERPROOF RECEPTACLE, 125VW REC-Z#26 27 26 IEC PIN AND SLEEVE RECEPTACLE, 600V# PP#26 27 23 POWER POLE QUAD RECEPTACLE CONTROLLED BY OCCUPANCY O REC-QUAD-O 26 27 26 REFER TO LUMINAIRE SCHEDULE W/RI RI RI-TECH 26 05 33 TECHNOLOGY OUTLET ROUGH-IN FACP FSCP GANN RPS P C RT D WP WP W I/O CR CC CM CT2 DH CO CP CS F MAP FIRE ALARM CONTROL PANEL MANUAL PULL STATION FIREFIGHTERS SMOKE CONTROL PANEL POINT LED GRAPHIC ANNUNCIATOR REMOTE POWER SUPPLY PHOTOELECTRIC SMOKE DETECTOR HEAT DETECTOR DUCT DETECTOR WITH TEST SWITCH SPEAKER/STROBE SPEAKER WEATHERPROOF HORN/STROBE WEATHERPROOF SPEAKER/STROBE FIREFIGHTER'S TELEPHONE JACK WARDEN'S TELEPHONE SPRINKLER WATER FLOW SWITCH SPRINKLER VALVE TAMPER SWITCH INPUT/OUTPUT MODULE CONTROL RELAY SIGNAL MODULE SIGNAL MONITOR MODULE DUAL INPUT MODULE DOOR HOLDER (120V) FIRE/SMOKE DAMPER CARBON MONOXIDE DETECTOR TWO-WAY COMMUNICATION PANEL TWO-WAY COMMUNICATION STATION FIRE ALARM GRAPHIC MAP STROBE HORN/STROBE ELECTRICAL SYMBOL LIST SYMBOL: DESCRIPTION: AMP VOICE AMPLIFIER CAB RECORD DOCUMENT BOX DATC DIGITAL ALARM COMMUNICATOR PLAN OR DETAIL NUMBER PLAN OR DETAIL NAME PLAN OR DETAIL SCALE DETAIL REFERRED TO BY SECTION CUT SHEET DETAIL IS LOCATED ON NAME 1 VIEW NAME 1/8" = 1'-0" 1 M101 143 2 SIMSIM INDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONS LEVEL NAME 10' -0"HEIGHT ABOVE PROJECT 0' -0" 1 INDICATES NOTE USED TO DESCRIBE ADDITIONAL INFORMATION ABOUT WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL NOR HT INDICATES DIRECTION OF TRUE NORTH VIEW KEY LINE TYPE AND TAG KEY: NEW WORK BY THIS CONTRACTOR (WIDE LINE) NEW EXISTING TO BE REMOVED (SHORT DASHED PATTERN) NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN) EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE) EXISTING EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN) EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN) HALFTONING DOES NOT MODIFY SCOPE. 'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING TAG-1 UNDERLINED TEXT INDICATES ADDITIONAL INFORMATION CAN BE FOUND ELSEWHERE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL T101 1. ##-###INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES OR SPECIFICATION. REFER TO DRAWINGS CONTAINING ELECTRICAL SCHEDULES. PERMANENT NAMEPLATE SHALL MATCH FINAL EQUIPMENT NOMENCLATURE, NOT ELECTRICAL EQUIPMENT TAG NAME, REFER TO SPECIFICATIONS. 2. {L###}INDICATES THE LIGHTING SEQUENCE OF OPERATION FOR THE SPACE. REFER TO THE LIGHTING SEQUENCE OF OPERATION MATRIX ON SHEET E/6.1.1. 3. "NL" INDICATES LUMINAIRE IS UNSWITCHED FOR NIGHT LIGHT. 4. "SE" INDICATES LUMINAIRE IS SWITCHED/CONTROLLED DURING NORMAL OPERATION AND OPERATES FROM EMERGENCY CIRCUIT UPON LOSS OF POWER. 5. SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO AN EMERGENCY CIRCUIT. 6. REFER TO SHEET E-6.1.1 FOR LIGHTING CONTROL ONE-LINE DIAGRAM. 7. REFER TO SHEET E-6.1.1 FOR LUMINAIRE SCHEDULE. 8. { Z###} INDICATES THE LIGHTING ZONES FOR THE SPACE. PROVIDE SEPARATE CONTROL OF EACH CONTROLLED ZONE. LUMINAIRES ASSOCIATED WITH THE SAME ZONE SHALL OPERATE TOGETHER WITHIN THE SAME PROGRAMMED SCENE. REFER TO SHEET E-6.1.1. 9. { B#} PUSH BUTTON REFERS TO SCENE QUANTITY. CONTROL STATION SHALL BE CAPABLE OF [RAISE/LOWER AND] SWITCHING ON/OFF FOR MULTIPLE SCENES AS INDICATED ON SHEETS AND THE LIGHTING SEQUENCE OF OPERATIONS {L##}. COORDINATE QUANTITIES OF BUTTONS FOR CONTROL STATIONS WITH LIGHTING CONTROL MANUFACTURER. REFER TO SHEET E-6.1.1. 10. { L##} DENOTES THE LIGHTING SEQUENCE OF OPERATIONS FOR THIS SPACE. REFER TO SHEET E-6.1.1. 11. VACANCY/OCCUPANCY SENSOR LAYOUT: SENSORS ARE SHOWN ON THE PLANS FOR DESIGN INTENT AND MAY NOT REPRESENT EVERY DEVICE. PROVIDE MANUFACTURER SPECIFIC FLOOR PLAN LAYOUTS SHOWING LOCATION, ORIENTATION, AND COVERAGE AREA OF EACH CONTROL DEVICE, SENSOR, AND CONTROLLER/INTERFACE. AREAS REQUIRING MULTIPLE SENSOR DEVICES FOR APPROPRIATE COVERAGE, SUBMIT SPECIFIC MANUFACTURER-APPROVED SENSOR LAYOUT AS AN OVERLAY DIRECTLY ON THE PROJECT DRAWINGS, EITHER IN PRINT OR APPROVED ELECTRONIC FORM. ELECTRICAL MOUNTING SUBSCRIPT KEY: A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH C MOUNT AT CEILING H MOUNT ORIENTED HORIZONTALLY L MOUNT IN CASEWORK M MOUNT IN MODULAR FURNITURE R MOUNT IN SURFACE RACEWAY EWC ELECTRIC WATER COOLER ELECTRICAL GENERAL NOTES: LUMINAIRE F1 = FIXTURE TAG 1 = CIRCUIT NUMBER a = SWITCH DESIGNATION NL = SUBSCRIPT (IF APPLICABLE) Z = ZONE DESIGNATION *IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS INFORMATION. EX: F1 / 1 / a / NL DEVICE A = MOUNTING (IF APPLICABLE) 1 = CIRCUIT NUMBER *IF LABEL IS ORIENTED HORIZONTALLY A SLASH WILL SEPARATE THIS INFORMATION. EX: A / 1 LUMINAIRE KEY: DEVICE KEY: issue date project # phasesheet projectownerrevision date 50% CONSTRUCTION DOCUMENTS -NOT FOR CONSTRUCTION8/26/2021 3:41:29 PME0.0.0 08/27/2021ELECTRICAL COVER SHEET21012.00 NOT FOR CONSTRUCTIONVANCE THOMPSON VISIONREFERENCE SCALE IN INCHES 0 1 2 3 PROJECT # IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2021 IMEG CORP. 175 N. 27TH STREET, SUITE 1312 BILLINGS, MT 59101-2048 406.545.6420 FAX: 406.256.1191 www.imegcorp.com 21001429.00 SITE PLAN SUBMISSIONSP PERMIT