Loading...
HomeMy WebLinkAbout004_A2.4.1_ROOFPLAN_08272021CDG22334455667HJYZZJJCCDDFFGGA5.1.16A5.1.16A4.1.11A4.1.114LLB.98XA5.2.319Y.3Y.3BBZ.5EG.23.1A5.1.118A5.1.118FA5.1.116A5.1.116A5.1.26A5.1.26A5.1.111A5.1.111A5.1.220A5.1.220A5.1.216A5.1.216A8.1.218A8.1.218AAA8.1.16A5.2.116A5.2.120A5.2.217A5.2.318A5.2.317A5.2.418A3.1.113A5.2.520A5.2.519A5.2.518A5.2.720A5.2.69A5.2.718A4.2.213A4.2.38A4.2.315A4.2.212A4.2.43A4.2.45A4.2.47A4.2.41A4.2.18A4.2.113A4.2.115A4.2.215A4.2.214A4.2.35A4.2.316A5.2.216A5.2.320A5.2.410A5.2.717A5.2.76A4.2.11207-0207-0207-02111.9C.77.9EEDD.5Y.28.3A5.2.617Y.5Y.7BB.7CC.9G.1F.17' - 1 7/8"9' - 8 1/4"3' - 7 1/2"8' - 11 1/4"1/4" / 12"1/4" / 12"1/4" / 12"1 /4 " / 1 2 " 1 /4 " / 1 2 " 1 /4 " / 1 2 "1 /4 " / 1 2 " 1 /4 " / 1 2 " 1 /4 " / 1 2 "1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"SCREENED SERVICEYARD, BELOW07-021/4" / 12"1 /4 " / 1 2 "1/4" / 12"1 /4 " / 1 2 "A5.2.6181 /4 " / 1 2 "1/4" / 12"1/4" / 12"1 /4 " / 1 2 "1/4" / 12"1 /4 " / 1 2 "1/4" / 12"1 /4 " / 1 2 "07-0307-0307-0307-0307-0307-0307-0307-0307-0307-0307-0407-0407-0407-0407-0407-0407-0407-0407-0407-0407-0407-0407-0405-0305-0305-0305-0323-0223-0223-0223-0323-0323-0323-0307-0707-0707-0607-0507-0807-0807-0805-0405-0407-0807-0307-0307-0307-031/4" / 12"CC.1RIDGERIDGERIDGERIDGERIDGERIDGE07-0207-0907-0907-0907-0907-0307-0307-09A8.1.31A8.1.31A5.2.416OVERLAPPED EDGE OF UPPER ROOF CANOPY,REF1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"1/4" / 12"A5.2.316RIDGEEG4.1.11EG4.1.12EG4.1.131/7A3.1.21/4" / 12"A5.3.51505-061A8.1.220A8.1.2201. PROVIDE ROOF CRICKETS AT ALL UPSLOPE AREAS OF MECHANICAL EQUIPMENT, CURBS AND ROOF HATCHES.2. CRICKETS TO SLOPE POSITIVELY 1/4" MINIMUM PER FOOT FROM HORIZONTAL PLANE.3. MAINTAIN 1/8" PER FOOT MINIMUM FOR ALL CRICKET VALLEYS.4. CRICKETS SHOWN ARE FOR REFERENCE ONLY; CONTRACTOR TO PROVIDE DETAILED LAYOUT PLAN FOR ARCHITECT'S REVIEW PRIOR TO INSTALLATION.5. ROOF PENETRATIONS OF ANY KIND SHALL NOT BE LOCATED IN CRICKET VALLEYS.6. IN ADDITION TO OPENING AND EQUIPMENT SHOWN ON THIS DRAWING, MECHANICAL AND ELECTRICAL DRAWINGS7. INDICATE ADDITIONAL ITEMS PENETRATING THE ROOF ASSEMBLY; PROVIDE APPROPRIATE FLASHING.8. REFERENCE MECH DRAWINGS FOR VENT LOCATIONS, EQUIPMENT LOCATIONS, AND ADDITIONAL INFORMATION, TYP.issue dateproject #phasesheetprojectownerrevision dateSITE PLAN SUBMISSION9/1/2021 2:27:41 PM8/27/20211A2.4.108.27.2021ROOF PLAN21012.00SITE PLANSUBMISSIONVANCE THOMPSON VISION1/8" = 1'-0"16ROOF PLANNORTH0'8'4'8'16'SCALE : 1/8" = 1'-0"ROOF PLAN NOTESKEYNOTES05-03 PERFORATED METAL SCREEN WALL, AROUND ROOFTOP AHU'S05-04 (3) 1 1/4" DIAMETER STEEL GUARD RAIL MOUNTED BETWEENWINDOW JAMBS; PROVIDE 1 1/4" VERTICAL POST TO ALIGN WITHEXTERIOR VERTICAL MULLION AT SPANS GREATER THAN 4'; PAINT05-06 ALUMINUM ROOF ACCESS LADDER, SEE ROOF DETAILS SHEETA5.3.507-02 ROOF CANOPY EDGE BELOW07-03 ACM PARAPET COPING, TYP07-04 PRIMARY & OVERFLOW ROOF DRAIN, REF PLUMBING DRAWINGS.07-05 2'x2' ROOF PAVERS W/ RAISED PEDESTAL SUPPORT SYSTEM,OVER MEMBRANE ROOF BELOW07-06 ROOFING BALLAST, 2" THICKNESS07-07 CONCRETE OVER METAL DECK W/ 6" MIN INSULATION, COVERBOARD & MEMBRANE ROOF. EXTENTS SHOWN GRAY07-08 GREEN ROOF MODULE SYSTEM, REF SPECIFICATIONS07-09 PRECAST CONCRETE WALL CAP23-03 CONDENSING UNIT, REF MECHANICAL DRAWINGS