HomeMy WebLinkAbout002_C3.1.3_SANITARYSEWERSTORMDRAIN_010520221/4" BELOW TOP OF NEW PAVEMENT SURFACE 3'-0" (MIN) HEAVY DUTY MONUMENT BOX, SIMILAR TO CAIRD ENG. NO. 50608-1 PAVING & GRAVEL AS REQUIRED SEAL JOINT WITH RAM-NEK 8" x 3' ROUND CONCRETE SLAB SLIP HUB TO THREADED ADAPTER THREADED PLUG FROST EXPANSION SLEEVE CLEANOUT PIPE - 4" Ø PVC 45° BEND NON-SHRINK BACKFILL END OF TRENCH VERIFY PIPE SIZE PER PLAN DIMENSIONS END OF LINE CLEANOUT (IF REQUIRED) USE PLUG AS REQUIRED USING VARIABLE LENGTH SECTIONS AS REQUIRED MANHOLE STEPS AT 16" ON CENTER 24" OPENING FLAT SLAB COVER CUTOUTS AS REQUIRED PRECAST OR POURED-IN-PLACE BASE. POURED-IN-PLACE BASE, MINIMUM CONCRETE THICKNESS BELOW PIPE IS EIGHT INCHES (8"). PRECAST BASE, MINIMUM THICKNESS TO BE SIX INCHES (6"). POURED-IN-PLACE BASE TO EXTEND BEYOND OUTER EDGE OF MANHOLE WALL. NOTES: 1.ALL JOINTS BETWEEN MANHOLE SECTIONS, ADJUSTING RINGS, MANHOLE RING & TOP SECTION, AND AROUND PIPE INTO MANHOLE SHALL BE WATERTIGHT. JOINTING MATERIAL SHALL BE "RAM-NEK" OR APPROVED EQUAL FOR ALL JOINTS EXCEPT BETWEEN PIPE AND MANHOLE WALL. 2.ADJUSTING RINGS AND CASTING SHALL BE CENTERED ON MANHOLE. 3.REMOVE SHIMS AND GROUT ANY GAPS BETWEEN THE CASTING, ADJUSTING RINGS, AND BARREL. REMOVE EXCESS GROUT. 4.GROUT ALL LIFTING HOLES IN BARREL. 5.ALL LATERAL PIPES SHALL BE FINISHED FLUSH WITH INNER BARREL WALL. MATCH TOP OF CURB ELEVATION EAST JORDAN IRON WORKS (EJIW) CURB INLET FRAME (7030Z1), GRATE (7030M2), & CURB HOOD (7030T1) VARIES - REFER TO PLAN 8" 6" MIN 12" MAX 4'-0" 2" THICK SAND CUSHION GRANULAR BEDDING MATERIAL (TYP) WATER OR SEWER LINE TRENCH BOTTOMTRENCH WALLTRENCH WALLALT. "B" INSTALLATION (TOP & BOTH SIDES): 4" THICK INSULATION BOARD - 8' MIN LENGTH ALONG WATER OR SEWER LINEALT. "A" (TOP ONLY) INSTALLATION (TOP ONLY): 4" THICK x 8' WIDE INSULATION BOARD CENTERED OVER WATER OR SEWER LINE - 8' MIN LENGTH ALONG WATER OR SEWER LINE * FOR CULVERT CROSSINGS, PROVIDE 18" MIN VERTICAL SEPARATION BETWEEN CULVERT AND WATER OR SEWER LINE * NOTES: 1.INSTALL INSULATION OVER ALL WATER LINES WITH LESS THAN 6'-6" COVER TO FINISHED GRADE, SEWER LINES WITH LESS THAN 5'-0" COVER TO FINISHED GRADE, OR WITHIN 2' BELOW A CULVERT. NOTIFY ENGINEER PRIOR TO PLACING INSULATION. 2.INSTALL INSULATION IN TWO, 2" THICK LAYERS. ROTATE ORIENTATION OR STAGGER JOINTS TO PROVIDE 2' MIN OVERLAP BETWEEN JOINTS. INSULATION SHALL EXTEND A MINIMUM OF 4' BEYOND THE OUTER WALLS OF THE CULVERT. 3.INSULATION BOARD SHALL BE 2" THICK EXTRUDED POLYSTYRENE INSULATION BOARD PER AASHTO M230-70. 4.SAND MAY BE USED TO PROVIDE THE BASE. INSULATION SHALL BE COVERED WITH 12" OF SAND OR OTHER OTHER SUITABLE GRANULAR BASE PRIOR TO COMPACTION OR ADDITIONAL BACKFILLING.2'-0" (MIN) 3" DEPTH OF CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE 1'-0" DEPTH OF 2" - 3" CLEAN, WASHED STONE (AASHTO #2 OR #3) 4'-0" WELL-TURNED AND BLENDED TOPSOIL REPLACED FROM EXCAVATION AND LIGHTLY COMPACTED MAX WATER SURFACE ELEVATION = 4643.0 RETENTION BASIN BOTTOM ELEVATION = 4640.5 GEOTEXTILE SEPARATOR (MIRAFI RS380i OR APPROVED EQUAL) INSTALLED ALONG TOP, BOTTOM, AND SIDES OF STONE RESERVOIR 4:1 (MAX) TURF SLOPE (BOTH SIDES) CURB & GUTTER NATIVE GROUND (TYP) 2'-0" (MIN) 3" DEPTH OF CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE 1'-0" DEPTH OF 2" - 3" CLEAN, WASHED STONE (AASHTO #2 OR #3) 4'-0" WELL-TURNED AND BLENDED TOPSOIL REPLACED FROM EXCAVATION AND LIGHTLY COMPACTED MAX WATER SURFACE ELEVATION = 4645.5 RETENTION BASIN BOTTOM ELEVATION = 4643.0 GEOTEXTILE SEPARATOR (MIRAFI RS380i OR APPROVED EQUAL) INSTALLED ALONG TOP, BOTTOM, AND SIDES OF STONE RESERVOIR 4:1 (MAX) TURF SLOPE (BOTH SIDES) CURB & GUTTER NATIVE GROUND (TYP) Know what's below. before you dig.Call R NOT TO SCALE SANITARY SEWER & STORM DRAIN CLEANOUT DETAIL NOT TO SCALE COMBINATION MANHOLE INLET DETAIL02720-1A PVC CLEANOUT 2" 3" MIN.GRADE PVC CLEANOUT WITH THREADED PLUG 10" ROUND VALVE BOX, GREEN, WITH LOCKING LID, CENTERED OVER CLEANOUT GRAVEL BEDDING & BACKFILL 2" 2" FINISHED NOT TO SCALE CLEANOUT BOX - LANDSCAPED AREAS NOT TO SCALE PIPE INSULATION issue date project # phasesheet projectownerrevision date C3.1.3SANITARY SEWER AND STORM DRAIN DETAILS21012.00VANCE THOMPSON VISIONBID & PERMIT SETSCALE: 1/2" = 1'-0" 11"x17" SCALE: 1/4" = 1'-0" SECTION A-A: SURFACE RETENTION BASIN CROSS SECTION SCALE: 1/2" = 1'-0" 11"x17" SCALE: 1/4" = 1'-0" SECTION B-B: SURFACE RETENTION BASIN CROSS SECTION No. 49499 CELINE M PROFE SSIONAL E N G INEERM O N T AN A LICENSE D SAUCIER 100% BID & PERMIT 02.25.22 5 02/25/22 5