HomeMy WebLinkAbout002_C3.1.2_WATERDETAILS_01052022MJ GLANDMJ VALVEMJ GLANDD.I.PIPED.I.PIPEMJ TEED.I. PIPED.I. PIPEMJ GLANDCONCRETE THRUSTBLOCK (TYP)UNDISTURBEDEARTH (TYP)MJ GLANDMJ VALVED.I. PIPE3/4" MIN. CORROSION RESISTANT ALL THREADRESTRAINING ROD, CONFORMING TO ASTM A242-81,INSTALLED IN HALF THE AVAILABLE MECHANICAL JOINTBOLT HOLES (TYP) WHERE NECESSARY, CLAMPINGLUGS (ROMAC "DUCTILE LUG" OR EQUAL) DESIGNEDTO FIT DUCTILE IRON (D.I.) PIPE, AND CONFORMINGTO ASTM 536-80 MAY BE USED IN CONJUNCTIONWITH THE RESTRAINING RODS."C""B""A"6""C"REBARANCHORCONCRETEANCHORSNOTE: COAT ROADS WITH "KOPPERS" BITUMASTIC NO. 50 COATING OR EQUAL.THRUST BLOCK DIMENSIONSANCHORROD SIZEVALVESIZE100 PSIABC150 PSIABC200 PSIABC250 PSIABC300 PSIABC1/2"6" & 8"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-0"2'-7"1/2"10"2'-0"2'-0"2'-0"2'-6"2'-6"2'-0"2'-9"2'-6"2'-6"3'-0"3'-0"3'-0"3'-7"3'-0"3'-0"1/2"12"2'-3"2'-0"2'-0"3'-0"3'-0"2'-8"3'-5"3'-0"3'-0"4'-3"3'-0"3'-0"5'-1"3'-0"3'-0"1"14"2'-3"2'-0"2'-0"3'-5"3'-0"3'-0"4'-6"3'-0"3'-0"4'-0"4'-0"4'-0"4'-9"4'-0"4'-0"1-1/8"16"3'-0"3'-0"3'-0"4'-4"3'-0"3'-0"4'-1"4'-0"4'-0"5'-1"4'-0"4'-0"6'-1"4'-0"4'-0"1-1/4"18"3'-8"3'-0"3'-0"5'-5"3'-0"3'-0"5'-1"4'-0"4'-0"6'-4"4'-0"4'-0"5'-9"5'-0"5'-0"1-3/8"24"4'-4"4'-0"4'-0"6'-5"4'-0"4'-0"6'-6"5'-0"5'-0"6'-5"6'-0"6'-0"7'-8"6'-0"6'-0"NOTE: PRESSURES SHOWN ABOVE ARE MAXIMUM WORKING PRESSURES IN THE SYSTEM.THRUST BLOCKING AND ANCHORS ARE REQUIRED ON ALL 6" VALVES AND LARGER UNLESS SPECIFIED BY THE ENGINEER.MEGA-LUG OR APPROVED EQUAL JOINT RESTRAINTS MAY BE USED IN LIEU OF CONCRETE THRUST BLOCKS.THRUST BLOCKS NOT REQUIRED ON TAPPING VALVES.1'-0" (MIN) &2'-0" (MAX)WATER SERVICE LINE STUB(SEE C.O.B. STANDARD DRAWING NO. 02660-6)PROPERTY LINEOR EASEMENTSERVICE LINE1'-0" (MIN) &2'-0" (MAX)1'-0" (MIN) &2'-0" (MAX)FOUNDATIONWALLBACKFLOW PREVENTIONASSEMBLY (AS REQUIRED)TO DOMESTICFIXTURESDOWNSTREAMSHUT-OFF**FLOORMETER*ANGLE STOP ORSTRAIGHT STOP*METER SHALL BE SAME SIZE AS INCOMING LINE - NO EXCEPTIONS, METER MUST CONNECT DIRECTLYTO ANGLE OR STRAIGHT STOP AND BACKFLOW DEVICE**DOWNSTREAM SHUT-OFF VALVE MUST BE SEPARATE FROM BACKFLOW DEVICEDETAIL ATYPICAL WALL PENETRATION(NOT TO SCALE)1'-0" (MIN)TO DOMESTICFIXTURESDOWNSTREAMSHUT-OFF**FOUNDATIONWALLMETER*ANGLE STOPBACKFLOW PREVENTIONASSEMBLY (AS REQUIRED)QUARTER-BEND COUPLING(1-1/2" & 2" SERVICES ONLY)*METER SHALL BE SAME SIZE AS INCOMING LINE - NO EXCEPTIONS, METER MUST CONNECTDIRECTLY TO ANGLE OR STRAIGHT STOP AND BACKFLOW DEVICE**DOWNSTREAM SHUT-OFF VALVE MUST BE SEPARATE FROM BACKFLOW DEVICEDETAIL BTYPICAL FLOOR PENETRATION (CRAWL SPACE)(NOT TO SCALE)WATER MAINCURB STOPAND BOXNEAREST FOUNDATIONWALL TO CURB STOPSEE DETAILSA & B BELOW6'-6" (78")(MIN)COVERWATER SERVICE LINEINSTALLED BY CUSTOMER(SERVICE APPLICATION & PLUMBING PERMIT REQUIRED)INSTALLATION REQUIREMENTS:1.WATER SERVICE LINE INSTALLATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF BOZEMAN WATER SUPERINTENDANT.2.SERVICE LINES SHALL BE TYPE K COPPER FOR 3/4", 1", 1-1/2", AND 2" SERVICES. REFER TO C.O.B. STANDARD DRAWING NO. 02660-12 FOR 4" AND LARGER DOMESTIC SERVICE LINES. SERVICE LINES BETWEEN 2" AND 4" ARE NOT ALLOWED.3.STRAIGHT COPPER TUBING SHALL BE USED FOR 1-1/2" AND 2" SERVICES.4.SERVICE LINES SHALL BE BEDDED 3" UNDER AND OVER THE PIPE WITH SAND. NATIVE MATERIAL MAY BE USED AS BEDDING IF IT CONFORMS TO THE REQUIREMENTS OF MONTANA PUBLICWORKS STANDARD DRAWING 02221-2 AND DOES NOT CONTAIN ANY MATERIAL LARGER THAN 3/4".5.PROVIDE FLEXIBLE, WATER TIGHT CONNECTION FOR ALL WALL OR FLOOR PIPE PENETRATIONS.6.METERS SHALL BE INSTALLED BY THE CITY WATER DEPARTMENT AT CUSTOMERS' EXPENSE.7.NO SERVICE LINE SHALL BE BACKFILLED UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE WATER DEPARTMENT.8.CONTACT CITY OF BOZEMAN WATER DEPARTMENT FOR APPROVED LIST OF COPPER CONNECTIONS.9.WATER SERVICE LINE MAY BE REDUCED TO A SMALLER SIZE THAN THE WATER SERVICE STUB. REDUCTION MUST BE MADE WITHIN 18" OF CURB STOP.10.METER, BACKFLOW PROTECTION, AND INCOMING SERVICE LINE MUST ALL BE THE SAME SIZE.NOT TO SCALETYPICAL VALVE / TEE RESTRAINT DETAIL02660-10NOT TO SCALETHRUST BLOCKING FOR WATER MAIN VALVES DETAIL02660-3NOT TO SCALEWATER SERVICE LINE FROM CURB STOP TO BUILDING02660-15issue dateproject #phasesheet
project
ownerrevisiondateC3.1.2WATER DETAILS
21012.00BID/PERMIT SETVANCE THOMPSON VISION
BID & PERMIT SET
No. 49499CELINE MPROFESSIONALENGI
NEER MONTANALICENSEDSAUCIER100% BID & PERMIT10.29.20211 10/22/21