HomeMy WebLinkAbout21- Stormwater Annual Report1 of 12
WATER PROTECTION BUREAU
Agency Use
MTR04_____________
Date Rec’d:
Amount Rec’d:
Check No.:
Rec’d By:
FORM MS4-AR
MPDES Storm Water Small MS4 Annual Report Form
Reporting period is for the calendar year, January 1st through December 31st. Check one. Annual Report is due by March 1st of the following year.
2017 2018 2019 2020 2021
Instructions: This Annual Report Form is to be completed by each permittee and co-permittee authorized to discharge storm water under the General Permit for Storm Water Discharges Associated with Small Municipal Separate Storm Water Sewer Systems (MS4s). All authorized permittees and co-permittees are required to complete this Annual Report Form
for each calendar year reporting period. For co-permittees authorized under one permit
authorization or for co-permittees with multiple authorizations, you are required to complete this form and submit separate required documents/information exclusively for your respective regulated Small MS4 area(s). This completed Annual Report Form must be electronically
submitted to the Montana Department of Environmental Quality, Water Protection Bureau.
Electronic submission is required through the web-based tool: NetDMR. Additional
information is located on DEQ’s website: http://deq.mt.gov/Water/WQINFO/ctss/netdmr.
Small MS4 Authorization Number: MTR04_________________
Small MS4 Classification Traditional Non-Traditional
Small MS4 Name:
Small MS4 Mailing Address:
City, State, and Zip Code:
Small MS4 Contact Person (and Title):
Mailing Address:
City, State, and Zip Code:
Phone Number: ( ) E-mail address:
0002
City of Bozeman
P.O. Box 1230
Bozeman, MT 59771
Adam Oliver, Stormwater Program Manager
P.O. Box 1230
Bozeman, MT 59771
406-582-2916 aoliver@bozeman.net
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2 of 12
Storm Water Management Team: Attach an organizational chart identifying a primary SWMP coordinator and the positions responsible for implementing each minimum measure.
Requested above chart: Attached Not Attached
Has the permittee established and executed a formalized mechanism for
regular communication between storm water management team members? Yes No
Permittee’s SWMP Resources:
How many FTEs does the permittee designate to the MS4 permit? _____ If needed, provide an
explanation.
If more space is needed, submit on an additional page with corresponding reference or on a data storage device.
Answer the following five (5) questions on an additional page with corresponding reference or
on a data storage device. (1) What are the source(s) of funding for implementation of the MS4 permit and the estimated
percentage of the total budget allocated from each source listed?
(2) Specific to the annual reporting calendar year, how did the permittee justify commitment of resources or budget allocations to the implementation of the MS4 permit to decision-makers and the
public? Provide a summary of meetings and outcomes held with decision-makers and the public.
(3) Has the permittee demonstrated program effectiveness to obtain budget allocations for this
annual reporting calendar year or previous years? Why or why not? If so, what program effectiveness metrics were presented?
(4) How was this annual reporting calendar year’s approach to allocate resources different than the previous year’s approach?
(5) Was the permittee successful in their request for budget allocations? Describe the outcome and
factors that affected or resulted in that outcome.
Illicit Discharge Detection & Elimination:
Per the IDDE MCM requirement (Part II (3)(c.i)), has the permittee reviewed, and updated if needed, the storm sewer map during the calendar year?
Yes No
Per the IDDE MCM requirement (Part II (3)(e.i)), has the permittee dry
weather inspected and screened outfalls during the calendar year? Yes No
Fill in the blanks with numbers. The permittee has inspected ______ outfalls during this calendar
year. Since authorization under the 2017 General Permit, the permittee has inspected ______ total outfalls out of the ______ total MS4 outfalls.
SWMP 4.7
See SWMP Section 4.8
See SWMP Sec 1.3
See SWMP Sec 1.3
See SWMP Sec 1.3
See SWMP Sec 1.3
See SWMP Sec 1.3
See SWMP Sec 1.5
See SWMP Sec 1.5
8
340
540
449
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3 of 12
Per the Illicit Discharge Detection & Elimination MCM (Part II (3)(e.i)), the
permittee will complete the requirement to inspect and screen all outfalls
during dry weather by the end of the permit cycle.
Yes No
Construction Site Storm Water Management: During the calendar year, how many construction
storm water management plan reviews were completed (Part II (4)(b))? ______________
During the calendar year, how many construction projects were inspected for their storm water management controls (Part II (4)(c))? ______________
Pollution Prevention/Good Housekeeping for Permittee Operations: Has the permittee reviewed, and updated if needed, the inventory of
permittee-owned/operated facilities and activities (Part II (6)(a.i))?
Yes No
Has the permittee reviewed, and updated if needed, the map that identifies
the locations of facilities and known locations of activities (Part II (6)(a.ii))? Yes No
Has the permittee conducted annual storm water pollution prevention
training for permittee staff during the next permit year after development of each standard operating procedure (Part II (6)(a.v))?
*Not applicable during calendar year 2017, 2018, and 2019. Check “No” during these years.*
Yes No
Training: According to Part II (B) Training requirements, has the permittee
conducted applicable training during the 1st and 4th calendar years?
*Not required during calendar year 2018, 2019, and 2021. Check “No” during these years.*
Yes No
According to Part II (B) Training requirements, has the permittee conducted
applicable new employee training within 90 days of the hire date? Yes No
Special Conditions: Per Pre-TMDL Approval (Part III.A) requirements, attach the required
information regarding identification of all outfalls that discharge to impaired waterbodies, the
impaired waterbodies, and the associated pollutants of impairments. Summarize the BMPs implemented over the reporting period and a schedule of BMPs planned for the following year.
Attached Not Attached Not Applicable
Special Conditions: Approved TMDLs (Part III.B) requirements per calendar year below.
Calendar Year 2017: The permittee has attached a Sampling Plan that includes strategy rationale,
monitoring frequency, monitoring parameters, and monitoring locations.
Attached Not Attached Not Applicable
See SWMP Sec.
4.7 and 8.9
31
9
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4 of 12
Calendar Year 2017: The permittee has attached all outfalls that discharge to impaired waterbodies
and the associated pollutants of impairment.
Attached Not Attached Not Applicable
Calendar Year 2018: The permittee has attached all outfalls that discharge to impaired waterbodies
and the associated pollutants of impairment.
Attached Not Attached Not Applicable
Calendar Year 2019: The permittee has attached all outfalls that discharge to impaired waterbodies
and the associated pollutants of impairment.
Attached Not Attached Not Applicable
Calendar Year 2020: The permittee has attached all outfalls that discharge to impaired waterbodies
and the associated pollutants of impairment.
Attached Not Attached Not Applicable
Calendar Year 2020: The permittee has attached the TMDL section of the SWMP that identifies
the measures and BMPs it plans to implement, describes the MS4’s impairment priorities and long
term strategy, and outlines interim milestones for controlling the discharge of the pollutants of concern and making progress towards meeting the TMDL.
Attached Not Attached Not Applicable
Calendar Year 2021: The permittee has attached all outfalls that discharge to impaired waterbodies and the associated pollutants of impairment.
Attached Not Attached Not Applicable
Calendar Year 2021: The permittee has evaluated the TMDL section of the SWMP based on
monitoring results. The section has been revised, if needed, and is attached.
Attached Not Attached Not Applicable
Monitoring: Per requirements in Part IV (B), has the permittee attached monitoring results,
calculations, and evaluations?
Attached Not Attached Not Applicable
See SWMP Sec. 8.0
See SWMP Sec. 8.0
See SWMP Sec. 4.7
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5 of 12
INSTRUCTIONS: The permittee will only fill out the Annual Report
Attachments section below that corresponds to the calendar in which an Annual
Report is being submitted for. Attach the requested documents/information.
2017 Annual Report Attachments (1st Calendar Year)
Public Education and Outreach:
Per requirements a.i in the referenced MCM, attach the required information regarding key target audiences and associated pollutants.
Attached Not Attached
Public Involvement and Participation:
Per requirements a.i in the referenced MCM, attach the required information regarding the public
involvement approach and schedule of each key audience.
Attached Not Attached
Illicit Discharge Detection & Elimination:
Per requirements a.i in the referenced MCM, attach the required information regarding categories of
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements b.i in the referenced MCM, attach the required information regarding occasional
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements f.i in the referenced MCM, attach the required Illicit Discharge Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached
Construction Site Storm Water Management:
Per requirements a.iii in the referenced MCM, attach progress towards an Enforcement Response Plan and associated documents.
Attached Not Attached
Specific to Traditional MS4s and per requirements b.i in the referenced MCM, attach the construction storm water management plan review checklist.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements b.iii in the referenced MCM, attach the
construction storm water management plan review checklist.
Attached Not Attached Not applicable
Specific to Traditional MS4s and per requirements c.i in the referenced MCM, attach the
construction storm water management inspection form or checklist.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements c.ii in the referenced MCM, attach the
construction storm water management inspection form or checklist.
Attached Not Attached Not applicable
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
6 of 12
Post-Construction Site Storm Water Management in New and Redevelopment
Specific to Traditional MS4s and per requirements b.i in the referenced MCM, attach the post-
construction storm water management plan review checklist.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements b.ii in the referenced MCM, attach the post-
construction storm water management plan review checklist.
Attached Not Attached Not applicable
Per requirements in b.iii in the referenced MCM, attach the performance standards and associated
documents.
Attached Not Attached
2018 Annual Report Attachments (2nd Calendar Year)
Public Education and Outreach:
Per requirements b.i in the referenced MCM, attach the required information regarding outreach
messages.
Attached Not Attached
Per requirements c.i in the referenced MCM, attach the required information regarding a description of formats, distribution channels and schedule for key target audiences.
Attached Not Attached
Public Involvement and Participation:
Per requirements a.ii in the referenced MCM, attach the required information regarding participation
and key target audience feedback on approaches.
Attached Not Attached
Illicit Discharge Detection & Elimination:
Per requirements a.i in the referenced MCM, attach the required information regarding categories of
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements b.i in the referenced MCM, attach the required information regarding occasional
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Specific to Traditional MS4s and per requirements d.i in the referenced MCM, attach the adopted ordinance or other regulatory mechanism to prohibit illicit discharges.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements d.ii in the referenced MCM, attach the summary of legal authority to prohibit illicit discharges.
Attached Not Attached Not applicable
Per requirements d.iii in the referenced MCM, attach the required summary of the cooperative agreements.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
7 of 12
Attached Not Attached
Per requirements d.iv in referenced MCM, attach the Enforcement Response Plan and associated
documents.
Attached Not Attached
Per requirements e.ii in referenced MCM, attach the list of high priority outfalls.
Attached Not Attached
Specific to Traditional MS4s and per requirements f.iii in the referenced MCM, attach the summary
of investigations conducted and corrective actions taken per the required Illicit Discharge
Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements f.iv in the referenced MCM, attach the summary of investigations conducted and corrective actions taken per the required Illicit Discharge Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Post-Construction Site Storm Water Management in New and Redevelopment
Specific to Traditional MS4s and per requirements c.i in the referenced MCM, attach the post-construction storm water management inspection form or checklist.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements c.ii in the referenced MCM, attach the post-
construction storm water management inspection form or checklist.
Attached Not Attached Not applicable
Per requirements in c.iii in the referenced MCM, attach the inventory of all new permittee-owned
and private post-construction storm water management controls.
Attached Not Attached
Per requirements in c.vi in the referenced MCM, attach an inspection frequency protocol.
Attached Not Attached
Specific to Traditional MS4s and per requirements c.vii, attach the developed inspection program.
Attached Not Attached Not applicable
Pollution Prevention/Good Housekeeping for Permittee Operations
Per requirements in a.iii in the referenced MCM, attach completed Standard Operating Procedures.
Attached Not Attached
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
8 of 12
2019 Annual Report Attachments (3rd Calendar Year)
Public Education and Outreach:
Per requirements c.ii in the referenced MCM, attach the required information regarding outreach
materials distributions.
Attached Not Attached
Public Involvement and Participation:
Per requirements a.ii in the referenced MCM, attach the required information regarding participation
and key target audience feedback on approaches.
Attached Not Attached
Illicit Discharge Detection & Elimination:
Per requirements a.i in the referenced MCM, attach the required information regarding categories of
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements b.i in the referenced MCM, attach the required information regarding occasional
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements e.ii in referenced MCM, attach the list of high priority outfalls.
Attached Not Attached
Per requirements e.iii in referenced MCM, attach the required summary of screening results.
Attached Not Attached
Specific to Traditional MS4s and per requirements f.iii in the referenced MCM, attach the summary
of investigations conducted and corrective actions taken per the required Illicit Discharge
Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements f.iv in the referenced MCM, attach the
summary of investigations conducted and corrective actions taken per the required Illicit Discharge Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Construction Site Storm Water Management:
Specific to Traditional MS4s and per requirements a.i in the referenced MCM, attach the adopted ordinance or other regulatory mechanism to require construction storm water controls.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements a.ii in the referenced MCM, attach the legal
authority summary.
Attached Not Attached Not applicable
Per requirements a.iii in the referenced MCM, attach the adopted Enforcement Response Plan and
associated documents.
Attached Not Attached
Post-Construction Site Storm Water Management in New and Redevelopment
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
9 of 12
Per requirements in c.viii in the referenced MCM, attach findings and compliance actions regarding
inspections of high priority post-construction storm water management controls.
Attached Not Attached
Specific to Traditional MS4s and per requirements c.ix, attach the findings and resulting actions
regarding inspections of high priority privately-owned post-construction storm water management controls.
Attached Not Attached Not applicable
Pollution Prevention/Good Housekeeping for Permittee Operations
Per requirements in a.iii in the referenced MCM, attach the completed Standard Operating Procedures.
Attached Not Attached
2020 Annual Report Attachments (4th Calendar Year)
Public Education and Outreach:
Per requirements c.ii in the referenced MCM, attach the required information regarding outreach
materials distributions.
Attached Not Attached
Public Involvement and Participation:
Per requirements a.ii in the referenced MCM, attach the required information regarding participation
and key target audience feedback on approaches.
Attached Not Attached
Illicit Discharge Detection & Elimination:
Per requirements a.i in the referenced MCM, attach the required information regarding categories of
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements b.i in the referenced MCM, attach the required information regarding occasional
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements e.ii in referenced MCM, attach the list of high priority outfalls.
Attached Not Attached
Per requirements e.iii in referenced MCM, attach the required summary of screening results.
Attached Not Attached
Specific to Traditional MS4s and per requirements f.iii in the referenced MCM, attach the summary
of investigations conducted and corrective actions taken per the required Illicit Discharge
Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements f.iv in the referenced MCM, attach the
summary of investigations conducted and corrective actions taken per the required Illicit Discharge
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
10 of 12
Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Post-Construction Site Storm Water Management in New and Redevelopment
Specific to Traditional MS4s and per requirements a.i in the referenced MCM, attach the adopted
ordinance or other regulatory mechanism to require post-construction storm water controls.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements a.ii in the referenced MCM, attach the legal
authority summary.
Attached Not Attached Not applicable
Per requirements in a.iii in the referenced MCM, attach the Enforcement Response Plan and
associated documents.
Attached Not Attached
Per requirements in c.viii in the referenced MCM, attach findings and compliance actions regarding
inspections of high priority post-construction storm water management controls.
Attached Not Attached
Specific to Traditional MS4s and per requirements c.ix, attach the findings and resulting actions regarding inspections of high priority privately-owned post-construction storm water management controls.
Attached Not Attached Not applicable
Per requirements in d.i in the referenced MCM, attach a summary of the discussion outcomes.
Attached Not Attached
Pollution Prevention/Good Housekeeping for Permittee Operations
Per requirements in a.iii in the referenced MCM, attach the completed Standard Operating Procedures.
Attached Not Attached
2021 Annual Report Attachments (5th Calendar Year)
Public Education and Outreach:
Per requirements c.ii in the referenced MCM, attach the required information regarding outreach
materials distributions.
Attached Not Attached
Public Involvement and Participation:
Per requirements a.ii in the referenced MCM, attach the required information regarding participation
and key target audience feedback on approaches.
Attached Not Attached
Illicit Discharge Detection & Elimination:
Per requirements a.i in the referenced MCM, attach the required information regarding categories of
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
See SWMP Sec. 4.6
See SWMP Sec. 3.0
See SWMP Sec. 3.0
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
11 of 12
Attached Not Attached
Per requirements b.i in the referenced MCM, attach the required information regarding occasional
non-storm water discharges or flows, associated pollutants, and local controls or conditions.
Attached Not Attached
Per requirements e.ii in referenced MCM, attach the list of high priority outfalls.
Attached Not Attached
Per requirements e.iii in referenced MCM, attach the required summary of screening results.
Attached Not Attached
Specific to Traditional MS4s and per requirements f.iii in the referenced MCM, attach the summary
of investigations conducted and corrective actions taken per the required Illicit Discharge
Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Specific to Non-Traditional MS4s and per requirements f.iv in the referenced MCM, attach the
summary of investigations conducted and corrective actions taken per the required Illicit Discharge Investigation and Corrective Action Plan and any associated documents.
Attached Not Attached Not applicable
Post-Construction Site Storm Water Management in New and Redevelopment
Per requirements in c.viii in the referenced MCM, attach findings and compliance actions regarding inspections of high priority post-construction storm water management controls.
Attached Not Attached
Specific to Traditional MS4s and per requirements c.ix, attach the findings and resulting actions regarding inspections of high priority privately-owned post-construction storm water management
controls.
Attached Not Attached Not applicable
Pollution Prevention/Good Housekeeping for Permittee Operations
Per requirements in a.iii in the referenced MCM, attach completed Standard Operating Procedures.
Attached Not Attached
Attach any updates, changes, or improvements to the Small MS4 Storm Water Management
Program per requirements in Part IV (E).
Attached Not Attached Not applicable
See Attachment A
See SWMP Sec. 9.0
See SWMP Sec. 6.6 and Attachment B
See SWMP Sec. 6.6
See SWMP Sec. 4.5
See SWMP Sec. 4.7
See SWMP Sec. 4.7
See SWMP Sec. 4.6
See SWMP Sec. 4.6
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
12 of 12
Annual Report Form Signature
This Annual Report Form must be completed, signed, and certified as follows:
• For a corporation, by a principal officer of at least the level of vice president;
• For a partnership or sole proprietorship, by a general partner or the proprietor,
respectively; or
For a municipality, state, federal, or other public facility, by either a principal executive officer or rankin elected official.
All Permittees Must Complete the Following Certification:
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel
properly gather and evaluate the information submitted. Based on my inquiry of the persons who
manage the system, or those persons directly responsible for gathering the information, the
information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am
aware that there are significant penalties for submitting false information; including the possibility of fine and imprisonment for knowing violations. [75-5-633, MCA].
Certification of this form indicates conformance with the 2017 General Permit for Storm Water
Discharge Associated with Small Municipal Separate Storm Sewer Systems and the required Annual Reporting upon receipt of permit coverage.
Name (Type or Print)
Title (Type or Print) Phone Number
Signature Date Signed
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
City Manager
2/16/2022
Jeff Mihelich
406.582.2303
1
Facility Stormwater Pollution Prevention Plan
City Parking Garage and Parking Lots (4)
Downtown Bozeman
Bozeman, Montana 59771
2021 Report
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the Public Parking Garage and four Public Parking
Lots (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Alston, Water, Sewer, and Stormwater Superintendent
Leader: Josh Watson, Signs and Signals Foreman
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
The City parking facilities include a Parking Garage and four Parking Lots. All the City parking facilities are
located in the downtown area. The City parking facilities function similarly regarding stormwater, so all
five sites are included in this FSWPPP. Specifically, all the City parking lot facilities are comprised of
stabalized parking surfaces that drains stormwater to the City’s stormdrain infrastrucutre.
The Parking Garage includes two pre-treatment technologies: a sand/oil separator and a hydrodynamic
separator. The Parking Garage has two drainage basins:
a. Drainage basin #1: 0.75 acres of 100% impervious surface drains from the upper parking level and
conveys runoff to a hydrodynamic separator for pretreatment before discharging into stormdrain
infrastructure.
b. Drainage basin #2: 0.25 acres of 100% impervious surface drains stormwater off the retail suits
rooftops which are located on the western and northern faces of the Facility. This stormwater
runoff is pre-treated with a sand/oil separator before flowing into the sanitary sewer system.
Public Parking Lots #1,2,3, and 4, respectively, have the following drainage basins:
a. Drainage basin (Parking lot #1): 0.37 acres of 100% impervious parking space
b. Drainage basin (Parking lot #2): 0.25 acres of 100% impervious parking space.
c. Drainage basin (Parking lot #3): 0.55 acres of 90% impervious parking space.
d. Drainage basin (Parking lot #4): 0.40 acres of 100% impervious parking space.
4.0 WATERBODY
Stormwater runoff from the Parking Garage receives pretreatment in a hydrodynamic separator before
discharging to Bozeman Creek at outfall ID: OF.F04.00441. Stormwater from all four Public Parking Lots
discharge to Bozeman creek without pretreatment. The Montana Department of Environmental Quality
classifies Bozeman Creek as a 303(d) listed impaired waterbody because it does not fully support aquatic
life and primary contact/recreation beneficial uses. Bozeman Creek’s impairments include: Alterations in
stream-side (littoral) vegetative cover, Chlorophyll-a, E. coli, total nitrogen, and sedimentation and
siltation.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
5.0 SAMPLING
Facility sampling is not required for the FSWPPP.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Solids: Vehicle tracking
Oil and Grease: Vehicle leaks
Total Nitrogen: Organics
Phosphorus: Organics
Zinc: Metal surfaces and brake dust
Lead: Brake dust and exhaust
Copper: Brake dust and exhaust
Floatables: Litter
7.0 SITE ASSESSMENT
The site assessment outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility.
All Standards are listed in Section 7.3 of the City’s Stormwater Management Plan (SWMP).
Standard: Spill kits stocked with instructions, disposal bags, PPE, absorbents, and inlet barriers.
Site Components and Compliance Assessment:
Public Works Spill Response Vehicle
Compliant: Spill response materials stocked and maintained
Standard Operating Guidelines:
Inspect and purchase missing item annually
Corrective Action(s):
2021: None
Standard: Preventative maintenance performed on equipment and vehicles.
Site Components and Compliance Assessment:
City Vehicles
Compliant: Vehicles are inspected and maintained regularly, preventative maintained
is documented and files are stored in CityWorks
Standard Operating Guidelines:
Visual inspection of all vehicles before use
Complete maintenance of vehicles at the Vehicle Maintenance Facility
Document inspections, maintenance, and repair per Division specific guidelines
Corrective Action(s):
2021: None
Standard: Vehicles and equipment washed in designated locations.
Site Components and Compliance Assessment
City Vehicles
Compliant: Vehicles are washed off site at the designated wash bay at the Vehicle
Maintenance Facility
Standard Operating Guidelines:
Wash vehicles at the Vehicle Maintenance Facility designated wash bay
Corrective Action(s):
2021: None
Standard: Maintain stormwater facilities.
a. Site Components and Compliance Assessment:
Storm Conveyance Infrastructure
Compliant: All pretreatment infrastructure is maintained on a routine basis,
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
including cleaning of the hydrodynamic separator and sand/oil separator at the
Public Parking Garage
b. Standard Operating Guidelines:
Maintain all pretreatment units by cleaning assets on a routine schedule
Map the location of all stormwater infrastructure
c. Corrective Action(s):
2021: None
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
8.1 Small and Medium Spills: Typically, the major dimension is less than 6’ and can be contained, cleaned,
and eliminated using onsite personnel, spill kits and/or the Public Works vehicle.
Locate spill kit and put on PPE.
If necessary, deploy the Public Works spill response vehicle.
Control spill by stopping or securing the source.
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Team Leader and the Saftey Data Sheets (SDS) for spill and waste
disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.2 Large and Continuous Spills: Typically, the major dimension is greater than 6’, continuous flow, and
cannot be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to a Stormwater Program Coordinator.
9.0 TRAINING
Staff receives training related to this Facility per the requirements within the City’s MS4 Permit and
maintains training documentation in the SWMP.
10.0 INSPECTIONS
Stormwater staff completes an annual facility inspection and provides results to the Program Coordinator
who determines compliance with the City’s Facility Minimum Standards listed in the SWMP. Updates to
this FSWPPP occur based on the results from:
2021: Completed on September 28th
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project needs and plans to propose during the development of future Capital
Improvement Plans (CIP):
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
a. Use of parking Lot 4 as a LID Demonstration project along Bozeman Creek, an impaired waterway.
Cost: TBD
Timeline: Propose in CIP
12.0 RECORD KEEPING AND REPORTING
Staff stores copies of this FSWPPP at the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 1 of 7
Facility Stormwater Pollution Prevention Plan
City Shops Complex
814 North Bozeman Avenue
Bozeman, Montana 59715
2021 Report
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the City Shops Complex (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Alston, Water, Sewer, and Storm Superintendent
Leader: John Vandelinder, Streets Superintendent
Leader: Thom White, Parks Superintendent
Leader: Mike Gray, Facilities Superintendent
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
The Facility includes buildings, parking lots, and staging areas for the Streets, Parks, Facilities,Water,
Sewer, Storm Divisions. The Facility has three distinct drainage basins:
Drainage Basin #1: 2.52 acres with 89% impervious cover. Drainage system components include
six inlets, 550 feet of storm sewer, and a four-foot diameter Contech CDS mechanical separation
unit. Basin #1 discharges into a storm drain beneath Tamarack St. to the north, which discharges
into Bozeman Creek at Outfall OF.E03.00450.
Drainage Basin #2: 0.56 acres with 98% impervious cover. Drainage system components include a
valley gutter, inlet, and 20 feet of storm drain. Basin #2 discharges into a storm drain beneath
Tamarack St. to the north, which dumps into Bozeman Creek at Outfall OF.E03.00450.
Drainage Basin #3: 0.82 acres with 90% impervious cover. Drainage system components include
four inlets, 144 feet of storm sewer, and an underground infiltration facility. Basin #3 discharges
to an underground infiltration facility.
4.0 IMPAIRED WATERBODIES
Drainage basins #1 and #2 discharges to Bozeman Creek at Outfall OF.E03.00450. The Montana
Department of Environmental Quality classifies Bozeman Creek as a 303(d) listed impaired waterbody
because it does not fully support aquatic life and primary contact/recreation beneficial uses. Bozeman
Creek’s impairments include: Alterations in stream-side (littoral) vegetative cover, Chlorophyll-a, E. coli,
total nitrogen, and sedimentation and siltation.
5.0 SAMPLING
Staff conducted baseline sampling on April 20 and 26, 2019, at the following locations:
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 2 of 7
Figure 5.0: Sampling location map.
Staff analyzed the following parameters and compiled the results:
Total Suspended Solids (TSS), mg/L
Chemical Oxygen Demand (COD), mg/L
Total Nitrogen (TN), mg/L
Total Phosphorus (TP), mg/L
Copper (Cu), mg/L
Table 5.1: Facility sampling results.
Lead (Pb), mg/L
Zinc (Zn), mg/L
Oil and Grease, mg/L
pH, standard units
Sampling Date TSS
(mg/L)
Oil &
Grease
(mg/L)
Total
Nitro.
(mg/L)
Phosp.
(mg/L)
Zinc
(mg/L)
Lead
(mg/L)
Copper
(mg/L)
COD
(mg/L) pH
April 20, 2019 1,930 11.0 5.56 3.07 1.560 0.122 0.245 1350 7.5
April 26, 2019 14,100 5.0 8.70 4.28 1.940 0.153 0.352 548 8.0
Median 8,015 8.0 7.13 3.68 1.750 0.138 0.299 1450 7.8
The data shows the Facility yields high concentrations of TSS, oils and grease, phosphorous, zinc, lead,
copper, and COD.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Sediment (TSS): Uncontained vehicle and equipment washing, organics
Oil and Grease: Fueling, vehicle leaks, uncontained vehicle and equipment washing
Total Nitrogen: Fertilizer transfers, uncontained vehicle and equipment washing, organics
Phosphorus: Fertilizer transfers, uncontained vehicle and equipment washing, organics
Zinc: Steel surfaces, brake dust, uncontained vehicle and equipment washing
Lead: Brake dust, uncontained vehicle and equipment washing
Copper: Brake dust, uncontained vehicle and equipment washing
COD: Vehicle and equipment leaks, uncontained vehicle and equipment washing
7.0 SITE ASSESSMENT
Section 7.0 outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility. All
Standards are listed in the City’s Stormwater Management Plan (SWMP).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
Standard: Wash bays and interior floor drains connected to the sanitary sewer.
a. Site Components and Compliance Assessment:
North Complex Building Floor Drains
Compliant: Connected to the sanitary sewer with P-trap
South Complex Building Floor Drains
Compliant: Connected to the sanitary sewer with sand-oil separator
Green Shed Floor Drains
Non-compliant: Connected to infiltration drain system without pretreatment
Wash Bay #1 Drain System
Non-compliant: Connected to storm drain (infiltration facility downline)
Wash Bay #2 Drain System
Non-compliant: Connected to storm drain (CDS mechanical separator downline)
b. Standard Operating Guidelines:
Annual inspection (condition, debris depth, accumulated pollutants)
Schedule maintenance as needed to maintain the intended function of CDS mechanical
separator
c. Corrective Action(s):
2019: Retrofit Green Shed floor drains or provide enhanced spill kit materials. Retrofit
Wash Bay #1 drain system. Retrofit or relocate Wash Bay #2 drain system
2020: Retrofit Green Shed floor drains, or provide enhanced spill kit materials. Retrofit
Wash Bay #1 drain system. Retrofit or relocate Wash Bay #2 drain system
2021: None
Standard: Chemicals stored under cover and within secondary containment.
a. Site Components and Compliance Assessment:
CRF storage tank
Non-compliant: Stored outside without secondary containment.
b. Standard Operating Guidelines:
Inspect storage containers weekly for leaks. This is a highly viscous material that will not
dissolve or flow quickly. CRF storage tanks that are not in use are primarily stored
indoors.
If a leak is detected, implement Spill Response Plan provided in Section 8.0
c. Corrective Action(s):
2019: Install secondary containment for CRF tank
2020: Install secondary containment for CRF tank
2021: Install secondary containment for CRF tank
Standard: Fuel tanks protected by secondary containment.
a. Site Components and Compliance Assessment:
500-gallon fuel tank
Compliant: Double-walled tank
b. Standard Operating Guidelines:
Insert nozzle securely into the vehicle fuel tank before engaging the pump
Stay with vehicle or equipment during fueling to reduce the chance of tank overflows
Shut off pump before removing the nozzle from the vehicle fuel tank
Securely place nozzle back into fuel tank cradle
Clean up spills immediately using the SOGs provided in Section 8.0
Inspect secondary containment annually per manufacturer’s recommendation
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
c. Corrective Action(s):
2019: None
2020: None
2021: None
Standard: Tracking prevented at all entries, exits, and within parking areas.
Site Components and Compliance Assessment:
Parking Areas, East Entrance, West Entrance, and South Entrance
Compliant: Asphalt surfaces
Wash Bays #1 and #2
Compliant: Debris accumulation controlled with sweeping
Standard Operating Guidelines:
Inspect paved surfaces for debris accumulation, sweep once present
Corrective Action(s):
2019: Improve operational controls and increased street sweeping
2020: None
2021: None
Standard: Spill kits stocked with instruction, disposal bags, PPE, absorbents, and inlet barriers.
Site Components and Compliance Assessment
Green Shed Spill Kit
Compliant: Instructions, disposal bags, PPE, and inlet barrier included
South Complex Building Spill Kit and North Complex Building Spill Kit
Compliant: Response plan, disposal bags, or PPE included
Fuel Tank Spill Kit
Compliant: Response plan and inlet barrier included
Standard Operating Guidelines:
Inspect and replace missing items annually
Corrective Action(s):
2019: Purchase inlet barrier mats for Green Shed and Fuel Tank spill kits. Place a copy of
the spill response plan with each spill kit. Provide disposal bags and PPE for the spill kits in
the Green Shed, South Complex Building, and North Complex Buildings. Purchase spill kit
for the fuel tank.
2020: None
2021: None
Standard: Preventative maintenance performed on equipment and vehicles.
Site Components and Compliance Assessment
Water/Sewer/Storm, Street, Parks, and Facility’s Equipment and Vehicles
Compliant: Vehicles and equipment inspected and maintained regularly, preventative
maintenance documentation filed in CityWorks
Standard Operating Guidelines:
Visual inspection of all vehicles and equipment before use
Complete maintenance and repairs at the Vehicle Maintenance Facility
Document inspections, maintenance, and repair per Division specific guidelines
Corrective Action(s):
2019: None
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5
2020: None
2021: None
Standard: Vehicles and equipment washed in designated locations.
Site Components and Compliance Assessment
Wash Bay #1
Compliant: Designated wash location
Wash Bay #2
Not Compliant: See ‘Wash Bay and Interior Floor Drain’ standard above
Standard Operating Guidelines:
Wash vehicles and equipment in Wash Bay #1
Corrective Action(s):
2019: Switch degreasers and soaps to EPA approved Safer Choice Products
2020: Switch degreasers and soaps to EPA approved Safer Choice Products
2021: Switch degreasers and soaps to EPA approved Safer Choice Products
Standard: Maintain above and below ground stormwater infrastructure.
d. Site Components and Compliance Assessment:
11 inlets and 714’ of storm drains
Compliant: Maintained once every five years
CDS mechanical Separator Treatment Unit
Compliant: Maintained annually
Underground Infiltration Facility
Not Compliant: Not maintainable due to design and installation error
e. Standard Operating Guidelines:
Maintenance schedules include:
Maintain treatment storm infrastructure annually
Maintain conveyance storm infrastructure once every five years
f. Corrective Action(s):
2019: See Section 11.0
2020: See Section 11.0
2021: See Section 11.0
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
8.1 Small and Medium Spills: Typically, the major dimension is less than 6’ and can be contained, cleaned,
and eliminated using onsite personnel, spill kits or the spill response vehicle.
Locate spill kit and put on PPE.
In necessary, deploy Public Works spill response vehicle.
Control spill by stopping or securing the source.
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Team Leader and the SDS for spill and waste disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Team Leader for appropriate reporting procedures.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
6
8.2 Large and Continuous Spills: Typically, the major dimension is greater than 6’, continuous flow, and
cannot be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to the Stormwater Program Coordinator.
9.0 TRAINING
Staff receives training related to this Facility per the requirements within the City’s MS4 Permit and
maintains training documentation in the SWMP.
10.0 INSPECTIONS
Stormwater staff completes an annual facility inspection and provides results to the Program Coordinator
who will determine compliance with the City’s Facility Minimum Standards listed in the SWMP. Updates to
this FSWPPP were based on the results from:
2019: Completed on March 21
2020: Completed on September 18
2021: Completed on September 14
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project needs and plans to propose to the City Commission during the
development of future Capital Improvement Plans (CIP):
a. Public Works Facility Space and Needs Assessment
Cost: ~$180,000
Timeline: Ongoing
b. Wash Bay #2 Drain System Retrofit or Relocation
Cost: $25,000
Timeline: Propose in CIP
c. Basin #2 Inlet Treatment Installation
Cost: $1,000
Timeline: 2021 Completion
d. Infiltration Facility Maintenance Access Modification
Cost: $15,000
Timeline: Propose in CIP
e. Facility Surfacing and Stormwater Upgrades (CDS Unit, ADS Infiltration System, and Wash Pad)
Cost: $250,000
Timeline: Completed in 2016
12.0 RECORD KEEPING AND REPORTING
Staff maintains copies of this FSWPPP at the Facility and the Stormwater Division Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
7
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Facility Stormwater Pollution Prevention Plan
East Gallatin Storage Area
2300 Block of North Rouse Ave
P.O. Box 1230
Bozeman, Montana 59771
Updated: 2021
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the East Gallatin Storage Area (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Vandelinder, Streets Superintendent
Leader: Alex Nordquest, Forestry Superintendent
Offsite Coordinator: Adam Oliver, Stormwater Program
3.0 SITE DESCRIPTION
The Facility provides storage for materials such as rock chips, street sweepings, cut boulevard trees, and
fill. One drainage basin exists:
Drainage Basin #1: 4.7 acres with 9% impervious cover from the newly constructed acess road on
the southern boudary of the Facility. A detention basin lies in the parking area just outside south
east of the Facility.
4.0 IMPAIRED WATERBODY
The Facility is adjacent to the East Gallatin River, which is impaired for nutrients; however, existing
topography holds water on site where it infiltrates and/or evaporates. Any discharge from the gravel work
and storage area is treated by a detention basin before discharging to the East Gallatin River at Outfall ID:
OF.F01.00638.
5.0 SAMPLING
Sampling is not required for this FSWPPP.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Solids: Traction sand
and organics (ex. tree trimmings and
mulch)
Oil and Grease: Vehicle leaks
Total Nitrogen: Organics
Phosphorus: Traction sand and organics
Zinc: Metal surfaces and brake dust
Lead: Brake dust and exhaust
Copper: Brake dust and exhaust
pH: Concrete washout
Floatables: Litter
7.0 SITE ASSESSMENT
Section 7.0 outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility. All
Standards are listed in the City’s Stormwater Management Plan (SWMP).
Standard: Tracking controlled at all entries, exits, and within parking areas.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
Site Components and Compliance Assessment:
Gravel lot
Compliant: Asphalt entrance and compacted gravel lot
Standard Operating Guidelines:
Sweep paved entryway if a noticeable accumulation of debris occurs
Corrective Action(s):
2020: None
2021: None
Standard: Preventative maintenance on equipment and vehicles.
Site Components and Compliance Assessment:
Water/Sewer/Storm, Forestry, and Street Division Equipment and Vehicles
Compliant: Vehicles and equipment inspected and maintained regularly, and
preventative maintenance documentation is filed in CityWorks
Standard Operating Guidelines:
Visual inspection of all vehicles/equipment before use
Complete minor maintenance and repair of equipment indoors. Complete more extensive
work at the Vehicle Maintenance Facility
Document inspections, maintenance, and repair per Division specific guidelines
Corrective Action(s):
2020: None
2021: None
Standard: Stabilize disturbed areas within 14-days.
a. Site Components and Compliance Assessment:
Ongoing construction of the access road from the southwest includes erosion and
sediment control BMPs, and will be stabilized post-construction
Compliant
b. Standard Operating Guidelines:
None
c. Corrective Action(s):
2020: None
2021: None. Maintain temporary BMPs when road construction resumes
Standard: Store chemicals under cover and within secondary containment.
a. Site Components and Compliance Assessment:
Water containers are stored on site, no chemicals stored at the Facility
Compliant
Uncontained concrete washout on the ground
Not Compliant
b. Standard Operating Guidelines:
Contain concrete washout in a lined capture area, let liquids dry/evaporate, and dispose
solids in a dumpster or haul directly to the landfill
City crews construct a temporary washout if needed and dispose of it in the onsite
dumpster
c. Corrective Action(s):
2020: Construct a temporary or permanent concrete washout
2021: None.
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
8.1 Small and Medium Spills: Typically, major dimension is less than 6’ and can be contained, cleaned,
and eliminated using onsite personnel, spill kits and/or the Public Works vehicle.
Locate spill kit and put on PPE.
If necessary, deploy Public Works spill response vehicle.
Control spill by stopping or securing the source.
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Team Leader and the SDS for spill and waste disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.2 Large and Continuous Spills: Typically, major dimension is greater than 6’, continuous flow, and
cannot be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to a Stormwater Team Leader.
9.0 TRAINING
Staff receives training related to this Facility per the requirements within the Citys MS4 Permit and
maintains training documentation in the SWMP.
10.0 INSPECTIONS
The Offsite Coordinator, or their designated representative, completes an annual inspection at the Facility
to determine compliance with the City’s Facility Minimum Standards listed in the SWMP. Updates to this
FSWPPP occur based on the results.
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project needs and plans to propose during the development of future Capital
Improvement Plans (CIP):
None
12.0 RECORD KEEPING AND REPORTING
Staff store copies of this FSWPPP at the City Shops Facility and the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Facility Stormwater Pollution Prevention Plan
City Fire Stations
Bozeman, Montana 59715
2021 Report
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOGs) developed to mitigate stormwater pollutants generated at the City Fire Stations (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Alston, Water, Sewer, and Stormwater Superintendent
Leader: Varies daily, Onsite Battalion Cheif
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
There are three City fire stations located in Bozeman. Fire station #1 is currently located downtown at 34
N. Rouse Ave., and will be relocated to the new Public Safety Center once construction is complete. It will
be added to this FSWPPP upon relocation. Fire Station #2 is presently located at 410 S 19th Ave. and will
soon be relocated to the Montana State University campus. The new Fire Station #2 will have stormwater
drainage built to modern design standards. Fire Station #3 is located at 1075 Vaquero Pkwy. All of the City
fire stations function similarly regarding stormwater impacts. Specifically, the fire stations are all
conventional buildings that drain stormwater to the City’s storm drain infrastructure. The drainage basins
at Fire Station #2 and #3 are as follows:
a. Drainage basin for Fire Station #2: 0.4 acres of 75% impervious cover. The rear impervious surface
sheet flows to a landscaped area where it infiltrates. The front of the building and driveway
discharges into inlet ID I.I05.00179.
b. Drainage basin for Fire Station #3: 1.9 acres of 70% impervious surface conveys storm runoff to
two onsite detention basins for treatment before discharging to Tributary – SWWW_00012.
4.0 WATERBODY
Fire Station #1 will be added to this FSWPPP once relocated to the new Public Safety Center in 2022. The
drainage basin of Fire Station #2: discharges stormwater directly to Farmers Canal at Outfall ID:
OF.I05.00350. Fire Station #3 discharges stormwater indirectly from two onsite detention ponds to
Tributary – SWWW_00012 at Outfall ID: OF.K02.00270. The Montana Department of Environmental
Quality does not classify either Farmers Canal or Tributary – SWWW_00012 as 303(d) listed impaired
waterbodies. The new location for Fire Station #1 at the Public Safety Center will be located in the
Bozeman Creek Watershed and is designed to retain the 10-year, 2-hour event. The Montana Department
of Environmental Quality classifies Bozeman Creek as a 303(d) listed impaired waterbody because it does
not fully support aquatic life and primary contact/recreation beneficial uses. Bozeman Creek’s
impairments include: Alterations in stream-side (littoral) vegetative cover, Chlorophyll-a, E. coli, total
nitrogen, and sedimentation and siltation.
5.0 SAMPLING
Sampling is not required for this FSWPPP.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Solids: Organics (ex.
Grass clippings)
Oil and Grease: None
Total Nitrogen: Organics
Phosphorus: Organics
Zinc: Metal surfaces and brake dust
Lead: Brake dust and exhaust
Copper: Brake dust and exhaust
Floatables: None
7.0 SITE ASSESSMENT
The site assessment outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility.
All Standards are listed in Section 7.3 of the City’s Stormwater Management Plan (SWMP).
Standard: Spill kits stocked with instructions, disposal bags, PPE, absorbents, and inlet barriers
Site Components and Compliance Assessment:
Inside Spill Kits at Fire Station #2 and #3
Compliant: Spill kits are maintained.
Standard Operating Guidelines:
Inspect spill kit and purchase missing items annually
Maintain all spill kit supplies in a designated location
Corrective Action(s):
2021: None
Standard: Connect wash bays and interior floor drains to the sanitary sewer
Site Components and Compliance Assessment:
All City Fire Stations
Compliant: Fire Station #3 is built to modern stormwater design standards and thereby
has wash bays and interior floor drains that connect to the sanitary sewer. Fire Stations
#1 and #2 are scheduled to be relocated to newly constructed buildings that will be
built to modern stormwater design standards.
Standard Operating Guidelines:
Inspect floor drains as needed to make sure they are unclogged and functioning
Corrective Action(s):
2021: None
Standard: Preventative maintenance performed on equipment and vehicles
Site Components and Compliance Assessment:
Fire station vehicles
Compliant: Vehicles are maintained often
Standard Operating Guidelines:
Visually inspect all vehicles before use
Complete maintenance of vehicles at the Vehicle Maintenance Facility
Document inspections, maintenance, and repair per Division specific guidelines
Corrective Action(s):
2021: None
Standard: Vehicles and equipment washed in designated locations
Site Components and Compliance Assessment
Vehicles and equipment
Compliant: Vehicles and equipment are maintained at designated locations
Standard Operating Guidelines:
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
Designated wash locations include the Vehicle Maintenance Facility or inside the Fire
Stations above the wash bays
Corrective Action(s):
2021: none
Standard: Contain fuel tanks with secondary containment
Site Components and Compliance Assessment:
Fire Station #3
Compliant: A ConVault diesel secondary container is located outside behind bollards
Standard Operating Guidelines:
Insert nozzle securely into the vehicle fuel tank before engaging the pump
Stay with vehicle or equipment during fueling to reduce the chance of tank overflows
Shut off pump before removing the nozzle from the vehicle fuel tank
Securely place nozzle back into fuel tank cradle
Clean up spills immediately using the SOGs provided in Section 8.0
Inspect secondary containment annually per manufacturer’s recommendation
Corrective Action(s):
2021: None
Standard: Maintain stormwater facilities
Site Components and Compliance Assessment:
Fire Station #3 Detention Ponds (2)
Compliant: Maintained every fall for vegetation and debris clearing
Fire Station #3 238’ of storm drains
Compliant: Maintained once every five years
Standard Operating Guidelines:
Maintenance schedules include:
Maintain stormwater retention basin vegetation every fall
Maintain conveyance storm infrastructure every five years
Corrective Action(s):
2021: None
Standard: Wash bays and interior floor drains connected to the sanitary sewer
a. Site Components and Compliance Assessment:
Fire Station #2
Compliant: Connected to the sanitary sewer
Fire Station #3
Compliant: Connected to the sanitary sewer
b. Standard Operating Guidelines:
Annual inspection (condition, debris depth, accumulated pollutants)
c. Corrective Action(s):
2021: None
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
8.1 Small and Medium Spills: Typically, the major dimension is less than 6’ and can be contained, cleaned,
and eliminated using onsite personnel, spill kits and/or the Public Works vehicle.
Locate spill kit and put on PPE.
If necessary, deploy the Public Works spill response vehicle.
Control spill by stopping or securing the source.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Team Leader and the Safety Data Sheets (SDS) for spill and waste
disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.2 Large and Continuous Spills: Typically, the major dimension is greater than 6’, continuous flow, and
cannot be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to the Stormwater Program Coordinator.
9.0 TRAINING
Staff receives training related to this Facility per the requirements within the City’s MS4 Permit and
maintains training documentation in the SWMP. Additional spill response training is completed by Fire
Department personnel.
10.0 INSPECTIONS
Stormwater staff completes an annual facility inspection and provides results to the Program Coordinator
who determines compliance with the City’s Facility Minimum Standards listed in the SWMP. Updates to
this FSWPPP occur based on the results from:
2021: Completed on September 29th
Stormwater staff contacted the onsite Battalion Chief for the day of 9/29/21, Graver Johnson, before
inspecting the Facilities.
From the inspections, stormwater staff documented that the City Fire Stations as a facility presents
minimal to no risk to stormwater infrastructure or water quality, similar to structural facilities like City
Hall or the City Library.
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project needs and plans to propose during the development of future Capital
Improvement Plans (CIP):
a. None
12.0 RECORD KEEPING AND REPORTING
Staff store copies of this FSWPPP at the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Facility Stormwater Pollution Prevention Plan
Laurel Glen Operations Facility
5521 Saxon Way
P.O. Box 1230
Bozeman, Montana 59718
2021 Update
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the Laurel Glen Operations Facility (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Alston, Water, Sewer, and Stormwater Superintendent
Leader: Josh Watson, Signs and Signals Foreman
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
The Facility contains a vehicle/equipment storage building and sewer lift station accessed by a gravel
driveway and parking area. The Facility has one drainage basin, including:
Drainage Basin #1: 2.3 acres with 6% impervious cover, including a building and concrete pads.
4.0 WATERBODY
The Facility discharges to a subdivision detention basin that outfalls at OF.N03.00300 into Aakjer Creek.
5.0 SAMPLING
The Facility does not contain any storm notable drain infrastructure, as such Staff did not conduct
sampling.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Solids: Gravel driveway
and parking area, Organics (ex. Grass
clippings)
Oil and Grease: Vehicle leaks
Total Nitrogen: Organics
Phosphorus: Organics
Zinc: Metal surfaces and brake dust
Lead: Brake dust and exhaust
Copper: Brake dust and exhaust
Floatables: Litter
7.0 SITE ASSESSMENT
Section 7.0 outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility. All
Standards are listed in the City’s Stormwater Management Plan (SWMP).
Standard: Tracking controlled at all entries, exits, and within parking areas.
Site Components and Compliance Assessment:
Gravel access and parking areas.
Compliant: Compacted gravel surface
Standard Operating Guidelines:
Inspect area for trash. If present, collect and dispose
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
Sweep Saxon Way when noticeable accumulation of tracked debris occurs
Corrective Action(s):
2020: None
2021: None
Standard: Spill kits stocked with instructions, disposal bags, PPE, absorbents, and inlet barriers.
Site Components and Compliance Assessment:
Vehicle/Equipment Building
Compliant: Spill kit located next to flammable cabinet.
Standard Operating Guidelines:
Inspect spill kit and purchase missing items annually
Maintain all spill kit supplies in a single location
Corrective Action(s):
2020: None
2021: None
Standard: Preventative maintenance performed on equipment and vehicles.
Site Components and Compliance Assessment:
Water/Sewer/Storm, Street Equipment, and Vehicles
Compliant: Vehicles and equipment inspected and maintained regularly, preventative
maintenance documentation filed in CityWorks
Standard Operating Guidelines:
Visual inspection of all vehicles/equipment before use
Complete minor maintenance and repair of equipment indoors. Complete more extensive
work at the Vehicle Maintenance Facility
Document inspections, maintenance, and repair per Division specific guidelines
Corrective Action(s):
2020: None
2021: None
Standard: Vehicles and equipment washed in designated locations.
Site Components and Compliance Assessment
Compliant: Vehicles/Equipment washed off site at the Vehicle Maintenance Facility
Standard Operating Guidelines:
Wash vehicles at the Vehicle Maintenance Facility in the designated location
Corrective Action(s):
2020: none
2021: None
Standard: Wash bays and interior floor drains connected to the sanitary sewer.
a. Site Components and Compliance Assessment:
Laurel Glen Operational Facility
Compliant: Connected to the sanitary sewer
b. Standard Operating Guidelines:
Annual inspection (condition, debris depth, accumulated pollutants)
Schedule maintenance as needed to maintain the intended function
c. Corrective Actions:
2019: None
2020: None
2021: None
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
Standard: Maintain above and below ground stormwater infrastructure
a. Site Components and Compliance Assessment:
Storm Conveyance Infrastructure
Compliant: All nearby infrastructure is mapped on GIS, all of which is off site
b. Standard Operating Guidelines:
Communicate maintenance responsibilities with Laurel Glen Homeowner’s Association
about the detention pond
c. Corrective Action(s):
2021: The Facility is located within the Laurel Glen Homeowner’s Association, which is
responsible for the maintenance of the subdivision’s post-construction stormwater
basins. The City owns and maintains street infrastructure around the Facility. Vegetation
removal maintenance by the homeowner’s association is necessary to maintain the
capacity of the detention pond to the west of the Facility.
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
8.1 Small and Medium Spills: Typically, the major dimension is less than 6’ and can be contained, cleaned,
and eliminated using onsite personnel, spill kits and/or the Public Works vehicle.
Locate spill kit and put on PPE.
If necessary, deploy Public Works spill response vehicle.
Control spill by stopping or securing the source.
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Team Leader and the Saftey Data Sheets (SDS) for spill and waste
disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.2 Large and Continuous Spills: Typically, the major dimension is greater than 6’, continuous flow, and
cannot be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to a Stormwater Program Coordinator.
8.4 Sanitary Sewer Overflow.
a. Lift station onsite and bypass pumping equipment stored in the vehicle/equipment storage
building. See the Water and Sewer Division’s Sanitary Sewer Overflow SOGs for more details
about emergency procedures.
9.0 TRAINING
Staff receives training related to this Facility per the requirements within the City’s MS4 Permit and
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
maintains training documentation in the SWMP.
10.0 INSPECTIONS
Stormwater staff will complete an annual facility inspection and report the results to the Program
Coordinator who will determine compliance with the City’s Facility Minimum Standards listed in the
SWMP. Updates to this FSWPPP occur based on the results.
Initial site inspection completed September 24th, 2020
Updated site inspection completed September 17th, 2021
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project needs and plans to propose during the development of future Capital
Improvement Plans (CIP):
a. Reoccurring: The Facility is located within the Laurel Glen Home Owner’s Association, which is
responsible for the maintenance of the subdivision’s stormwater detention pond. Upon request
by the HOA, the City will likely have to contribute funding to complete maintenance-related work
for the stormwater basin adjacent to the Facility and others in the subdivision. The basin’s current
retention capacity is being reduced by vegetation.
12.0 RECORD KEEPING AND REPORTING
Staff store copies of this FSWPPP at the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Facility Stormwater Pollution Prevention Plan
Snow Storage Facility
501 Haggerty Lane
P.O. Box 1230
Bozeman, Montana 59771
2021 Update
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the Snow Storage Facility (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Vandelinder, Streets Superintendent
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
The Facility is an asphalt parking lot used for municipal snow storage during winter and spring. One
drainage basin exists, including:
Drainage Basin #1: 3.3 acres with approximately 40% impervious cover, including an asphalt
parking area and a section of Tributary SWWW_00040.
4.0 IMPAIRED WATERBODY
The Facility discharges to Tributary SWWW_00040, which then empties into a Tributary SWWW_00065
before the flow drains into Rocky Creek north of I-90.
The Montana Department of Environmental Quality (MDEQ) classifies Rocky Creek as a 303(d) listed
impaired waterbody because it does not fully support the aquatic life beneficial use. Rocky Creek’s
impairments include: Alteration in stream-side (littoral) cover, other anthropogenic substrate alterations,
physical substrate habitat alterations, and sedimentation-siltation.
5.0 SAMPLING
Staff conducted composite baseline sampling on April 9 and 24, 2019, at the following location:
Figure 5.0: Sampling Location Map.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
Staff analyzed the following parameters and compiled the results:
Total Suspended Solids (TSS), mg/L
Chemical Oxygen Demand (COD), mg/L
Total Nitrogen (TN), mg/L
Total Phosphorus (TP), mg/L
Copper (Cu), mg/L
Table 5.1: Facility sampling results.
Lead (Pb), mg/L
Zinc (Zn), mg/L
Oil and Grease, mg/L
pH, standard units
Sampling Date TSS
(mg/L)
Oil &
Grease
(mg/L)
Total
Nitro.
(mg/L)
Phosp.
(mg/L)
Zinc
(mg/L)
Lead
(mg/L)
Copper
(mg/L)
COD
(mg/L) pH
April 9, 2019 430 4 0.800 0.510 0.100 0.013 0.022 152.0 7.9
April 24, 2019 1,640 5 3.900 1.860 0.380 0.049 0.077 696.0 7.9
The data shows the Facility yields high concentrations of TSS and lead.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Solids: Traction sand
and organics (ex. Grass clippings)
Oil and Grease: Vehicle leaks
Total Nitrogen: Organics
Phosphorus: Traction sand and organics
Zinc: Metal surfaces and brake dust
Lead: Brake dust and exhaust
Copper: Brake dust and exhaust
Floatables: Litter
7.0 SITE ASSESSMENT
Section 7.0 outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility. All
Standards are listed in the City’s Stormwater Management Plan (SWMP).
Standard: Tracking controlled at all entries, exits, and within parking areas.
Site Components and Compliance Assessment:
Snow storage area
Compliant: Asphalt surface
Northwest Parking lot
Compliant: Asphalt surface
Standard Operating Guidelines:
Inspect asphalt for debris accumulation, sweep once present
Periodically clean around the Facility during melting (handpick and sweep as necessary)
Corrective Action:
2019: None
2020: None
2021: None
Standard: Preventative maintenance on equipment and vehicles.
Site Components and Compliance Assessment
Street Division Equipment and Vehicles
Compliant: Inspected and maintained regularly, documentation in place
Standard Operating Guidelines:
Visual inspection of all vehicles and equipment before use
Maintenance and repairs completed at the Vehicle Maintenance Facility
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
Document inspections, maintenance, and repairs per Division specific guidelines
Corrective Actions:
2019: None
2020: None
2021: None
Standard: Stabilize disturbed areas.
b. Site Components and Compliance Assessment:
Gully northeast of the Facility
Non-compliant: No major erosion events have occurred in recent years and
vegetation has stabilized this slope. Another disturbance was created at the south
end of the slope, which has also been stabilized. These sloped areas need to be
evaluated each year.
c. Standard Operating Guidelines:
See Section 11.0
d. Corrective Actions:
2019: See Section 11.0, remove the eastern boundary silt fence
2020: See Section 11.0, remove the eastern boundary silt fence
2021: See Section 11.0.a Infrastructure Improvement for proposed CIP to control
erosion and flow from onto the steep slopes east of the Facility. Temporary BMPs have
been removed.
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
8.1 Small and Medium Spills: Typically, major dimension is less than 6’ and can be contained, cleaned,
and eliminated using onsite personnel, spill kits and/or the spill response vehicle.
Locate spill kit and put on PPE.
If necessary, deploy Public Works spill response vehicle.
Control spill by stopping or securing the source.
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Team Leader and the SDS for spill and waste disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.2 Large and Continuous Spills: Typically, the major dimension is greater than 6’, continuous flow, and
cannot be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Team Leader for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to the Stormwater Team Leader.
9.0 TRAINING
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
Staff receives training related to this Facility per the requirements within the Citys MS4 Permit and
maintains training documentation in the SWMP.
10.0 INSPECTIONS
The Offsite Coordinator completes an annual inspection at the Facility to determine compliance with the
City’s Facility Minimum Standards listed in the SWMP. Updates to this FSWPPP occur based on the results.
2019: Completed on June 25
2020: Completed on September 10
2021: Completed on September 29
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project need and plans to propose to the City Commission during the
development of future Capital Improvement Plans (CIP):
a. Sediment Basin Construction, Slope Stabilization, and Culvert Maintenance
Cost: ~$75,000
Timeline: Propose in CIP, not yet scheduled
12.0 RECORD KEEPING AND REPORTING
Staff store copies of this FSWPPP at the City Shops Facility and the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 1 of 7
Facility Stormwater Pollution Prevention Plan
Vehicle Maintenance Facility
1812 North Rouse Avenue
Bozeman, Montana 59715
2021 Update
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the Vehicle Maintenace Facility (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: John Vandelinder, Streets Superintendent
Leader: Alex Nordquest, Forestry Division Manager
Leader: John Alston, Water, Sewer, and Storm Superintendent
Leader: Mike Gray, Facility Manager
Leader: Josh Waldo, Fire Chief
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
The Facility includes buildings, parking lots, and staging areas that support the Streets, Forestry, Facilities,
Fire, and Water/Sewer/Storm Divisions. The Facility has one drainage basin:
Drainage Basin #1: 8.4 acres with 62.5% impervious cover, including office and equipment storage
buildings, parking areas, material storage, and equipment staging. Basin #1 system components
include seven inlets, 1,125 feet of storm drain, and a detention basin. Basin #1 discharges into a
storm drain beneath Griffin Drive, which drains to the East Gallatin River.
4.0 IMPAIRED WATERBODY
The Vehicle Maintenance Facility discharges to the East Gallatin River at Outfall OF.E01.00050. The
Montana Department of Environmental Quality classifies the East Gallatin River as a 303(d) listed impaired
waterbody because it does not fully support the aquatic life and primary contact/recreation beneficial
uses. East Gallatin River impairments include total nitrogen and total phosphorous.
5.0 SAMPLING
Staff conducted baseline sampling on August 22, 2019, at the following location:
Graphic 5.0: Sampling Location Map.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 2 of 7
Staff analyzed the following parameters and compiled the results:
Total Suspended Solids (TSS), mg/L
Oil and Grease, mg/L
Total Nitrogen (TN), mg/L
Total Phosphorus (TP), mg/L
Zinc (Zn), mg/L
Table 5.1: Facility sampling results.
Lead (Pb), mg/L
Copper (Cu), mg/L
Chemical Oxygen Demand (COD), mg/L
pH, standard units
Sampling Date TSS
(mg/L)
Oil &
Grease
(mg/L)
Total
Nitro.
(mg/L)
Phosp.
(mg/L)
Zinc
(mg/L)
Lead
(mg/L)
Copper
(mg/L)
COD
(mg/L) pH
August 22, 2019 139 2.0 7.6 0.540 0.260 0.010 0.042 548 6.6
The data shows the Facility yields high concentrations of COD.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
TSS: Traction sand storage, equipment, unstabilized areas, organics
Oil and Grease: Vehicle and equipment leaks, stored chemicals
Total Nitrogen: Organics, traction sand
Phosphorus: Fertilizer transfers, organics, traction sand
Zinc: Steel surfaces, brake dust
Lead: Brake dust
Copper: Brake dust
COD: Vehicle and equipment leaks, traction sand
Magnesium Chloride: Stored chemicals
Used Antifreeze: Stored chemicals
7.0 SITE ASSESSMENT
The Site Assessment outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility. All
standards are listed in Section 7.3 of the City’s Stormwater Management Plan (SWMP).
Standard: Wash bays and interior floor drains connected to the sanitary sewer with pretreatment.
a. Site Components and Compliance Assessment:
Vehicle Maintenance Building
Compliant: Connected to the sanitary sewer with sand-oil separator
Vehicle Maintenance Building Wash Bay (east side of building)
Compliant: Connected to the sanitary sewer with sand-oil separator
b. Standard Operating Guidelines:
Annual inspection (condition, debris depth, accumulated pollutants)
Schedule maintenance as needed to maintain the intended function
c. Corrective Actions:
2019: None
2020: None
2021: None
Standard: Chemicals stored under cover and within secondary containment.
d. Site Components and Compliance Assessment:
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 3 of 7
1,000-gallon used oil tank
Compliant: Double-walled tank
Small metal used oil tank
Compliant: Inside storage (2021)
Spent antifreeze tank
Compliant: Double-walled tank
Spent antifreeze bottles
Compliant: Covered with secondary containment (2021)
10,000-gallon magnesium chloride tank
Not Compliant: No secondary containment
SumaGrow Barrel
Compliant: Inside storage (2021)
e. Standard Operating Guidelines:
Inspect storage containers weakly for leaks
If a leak is detected, implement Spill Response Plan provided in Section 8.0
f. Corrective Actions:
2019: Install secondary containment for small metal used oil tank, spent antifreeze bottles,
magnesium chloride tank, and SumaGrow barrel.
2020: Install secondary containment for magnesium chloride tank. Design is underway for
2021 construction.
2020: Install secondary containment for magnesium chloride tank. Design is complete and
pending internal review.
Standard: Tracking prevented at all entries, exits, and within parking areas.
Site Components and Compliance Assessment:
South Parking Lot, Fire Department Training Area, North Parking Lot, Forestry Entrance, West
Entrance
Compliant: Asphalt surface
Forestry Parking Lot
Not Compliant: Unimproved lot
Sand Storage Area
Not Compliant: Road mix surface
Standard Operating Guidelines:
Inspect paved surfaces for debris accumulation, sweep once present
Corrective Action:
2019: See Section 11.0.a
2020: See Section 11.0.a
2021: See Section 11.0.a
Standard: Spill kits stocked with instructions, disposal bags, PPE, absorbents, and inlet barriers.
Site Components and Compliance Assessment
Vehicle Maintenance Building Spill Response Materials
Compliant: Spill response material stocked and maintained
Spill Response Vehicle Spill Kit
Compliant: Spill response material stocked and maintained
Standard Operating Guidelines:
Inspect and purchase missing items annually
Corrective Actions:
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 4 of 7
2019: Purchase inlet barrier mats for Vehicle Maintenance Building and Spill Response
Vehicle, place a copy of the Facility FSWPPP with each spill kit, and purchase spill kit for used
oil/spent antifreeze deposition area
2020: None
2021: None
Standard: Preventative maintenance performed on equipment and vehicles.
Site Components and Compliance Assessment
Water/Sewer/Storm, Streets, Parks, and Facility’s Equipment and Vehicles
Compliant: Vehicles and equipment inspected and maintained regularly, preventative
maintenance documentation filed in CityWorks
Standard Operating Guidelines:
Visual inspection of all vehicles and equipment before use
Complete maintenance and repairs at the Vehicle Maintenance Facility
Document inspections, maintenance, and repair per Division specific guidelines
Corrective Action(s):
2019: None
2020: None
2021: None
Standard: Vehicles and equipment washed in designated locations.
Site Components and Compliance Assessment
Wash Bay
Compliant: Designated wash location
Standard Operating Guidelines:
Wash vehicles and equipment at the Wash Bay
Corrective Actions:
2019: None
2020: None
2021: None
Standard: Maintain stormwater facilities.
a. Site Components and Compliance Assessment:
Storm Conveyance Infrastructure
Compliant: Site map is updated annually and storm infrastructure maintained
Stormwater Detention Facility
Compliant: Maintained
g. Standard Operating Guidelines:
Maintenance schedules include:
Maintain stormwater retention basin vegetation every fall
Maintain conveyance storm infrastructure every five years
h. Corrective Actions:
2019: Install a barrier on the south edge of the detention facility, dredge deposited materials,
remove silt fence, clear inlet pipe and accumulated debris in the detention facility, map storm
infrastructure, place on maintenance schedule
2020: None
2021: None
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 5 of 7
8.0 SPILL RESPONSE PLAN
The following is the City’s spill response plan, including response, mitigation, and reporting protocols.
8.1 Small and Medium Spills: Typically, major dimension is less than 6’ and can be contained, cleaned, and
eliminated using onsite personnel, spill kits, or the spill response vehicle.
Locate spill kit and put on PPE.
If necessary, deploy Public Works spill response vehicle.
Control spill by stopping or securing the source.
Protect all storm drain inlets near the spill using absorbent booms or inlet barrier.
Identify spilled material.
Clean spill using appropriate absorbents or other methods. Never wash spills down the drain!
Place spill material and absorbents in secure containers.
Consult with Stormwater Program Coordinator and the Saftey Data Sheets (SDS) for spill and waste
disposal procedures.
Dispose of spilled material and the absorbent in compliance with state and federal regulations.
Consult with Stormwater Program Coordinator for appropriate reporting procedures.
8.2 Large and Continuous Spills: Typically, major dimension is greater than 6’, continuous flow, and cannot
be contained, cleaned, and eliminated using onsite personnel.
Leave the area and notify Emergency Responders (911).
Give the operator the spill location, chemical name, and approximate amount.
If safe, protect nearby storm drain inlets using absorbent booms or inlet barrier.
Provide SDS information for the spilled chemical to emergency responders.
Advise responders of any absorbents, containers, or spill control equipment that is available.
Consult with Stormwater Program Coordinator for appropriate reporting procedures.
8.3 Spill Reporting
Report all chemical spills, regardless of size, to the Stormwater Program Coordinator.
9.0 TRAINING
Staff receives training related to the Facility through the the City’s training software platform per the
requirements within the Citys MS4 Permit. Staff maintains training documentation in the SWMP.
10.0 INSPECTIONS
The Offsite Coordinator completes an annual inspection at the Facility to determine compliance with the City’s
Facility Minimum Standards listed in the SWMP. Updates to this FSWPPP occur based on the results.
Initial site inspection completed on August 6, 2019
Completed reinspection and updated FSWPPP on September 9, 2020
Completed reinspection and updated FSWPPP on September 14, 2021
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project needs and plans to propose to the City Commission during the
development of future Capital Improvement Plans (CIP):
a. Public Works Facility Space and Needs Assessment
Cost: ~$180,000
Timeline: 2023
b. Stabilize Forestry Parking Lot and Sand Storage Area
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 6 of 7
Cost: TBD
Timeline: Propose in CIP
c. Magnesium Chloride Secondary Containment
Cost: $75,000
Timeline: Propose in CIP
d. Used Oil Secondary Containment
Cost: $15,000
Timeline: Propose in 2022-2026 CIP
e. Spent Antifreeze Secondary Containment
Cost: $15,000
Timeline: Propose in 2022-2026 CIP
f. Suma Grow Secondary Containment
Cost: $15,000
Timeline: Propose in 2022-2026 CIP
12.0 RECORD KEEPING AND REPORTING
Staff maintains copies of this FSWPPP at the Facility and the City’s Stormwater Division office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Page 7 of 7
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Facility Stormwater Pollution Prevention Plan
Water Treatment Plant
7024 Sourdough Canyon Rd
P.O. Box 1230
Bozeman, Montana 59771
2021 Update
1.0 OVERVIEW
This Facility Stormwater Pollution Prevention Plan (FSWPPP) includes Standard Operating Guidelines
(SOG) developed to mitigate pollutants generated at the Water Treatment Plant (Facility).
2.0 STORMWATER TEAM
The following Staff members are responsible for the FSWPPP’s implementation:
Leader: Jill Miller, Water Treatment Plant Superintendent
Stormwater Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 SITE DESCRIPTION
The Facility treats drinking water before it is distributed throughout the City of Bozeman. The perimeter
is fenced. The site includes buildings that house various equipment and concrete drying beds basins used
to evaporate liquids, one surface retention facility, and one surface detention facility. Three drainage
basins exist, including:
Drainage Basin #1: 12-acres with 39% impervious cover, including parking lots and buildings.
Drainage Basin #2:11-acre closed basin primarily comprised of lawn area.
Drainage Basin #3: 10-acres with 18% impervious cover, including a 5.3 million gallon potable
water storage tank.
The Facility operates under federal and state requirements for groundwater discharge, surface water
discharge, and water treatment for municipal potable water supply. The Facility’s equipment, chemicals,
drains, water treatment controls, and membranes are contained within the interior of the Facility and
compliant with governing regulations.
4.0 WATERBODY
The Facility lies above 68 Ditch, which drains to Bozeman Creek. The Facility was constructed in 2014 and
includes a modern drainage design that meets the City’s water quality and flood control standards. The
risk of stormwater pollution and off-site discharge from the Facility is low.
5.0 SAMPLING
Staff conducted composite baseline sampling on Dec 2, 2020, at the following location:
Figure 5.0: Sampling Location.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
Staff analyzed the following parameters and compiled the results:
Total Suspended Solids (TSS), mg/L
Chemical Oxygen Demand (COD), mg/L
Total Nitrogen (TN), mg/L
Total Phosphorus (TP), mg/L
Copper (Cu), mg/L
Table 5.1: Facility sampling results.
Lead (Pb), mg/L
Zinc (Zn), mg/L
Oils and Greases, mg/L
pH, standard units
Sampling Date TSS
(mg/L)
Oil &
Grease
(mg/L)
Total
Nitro.
(mg/L)
Phosp.
(mg/L)
Zinc
(mg/L)
Lead
(mg/L)
Copper
(mg/L)
COD
(mg/L) pH
December 2, 2020 67 1.0 RL 1.3 0.239 0.04 0.002 0.007 61 6.8
The data shows the Facility yields low concentrations of all measured pollutants.
6.0 POLLUTION IDENTIFICATION
Following is a list of identified pollutants and an assessment of likely sources at the Facility:
Total Suspended Solids: Organics
Oil and Grease: Vehicle leaks
Total Nitrogen: Organics
Phosphorus: Organics
Zinc: Metal surfaces and brake dust
Lead: Brake dust and exhaust
Copper: Brake dust and exhaust
Other: Treatment chemicals
Floatables: Litter
7.0 SITE ASSESSMENT
The Site Assessment outlines the City’s Facility Minimum Standards (Standards) applicable to this Facility.
All Standards are listed in Section 7.3 of the City’s Stormwater Management Plan (SWMP).
Standard: Wash bays and interior floor drains connected to the sanitary sewer.
a. Site Components and Compliance Assessment:
Primary Building
Compliant: Drains are connected to onsite septic.
b. Standard Operating Guidelines:
Annual inspection (condition, debris depth, accumulated pollutants)
c. Corrective Action(s):
2020: None
2021: None
Standard: Chemicals stored under cover and within secondary containment.
Site Components and Compliance Assessment:
Chemical storage
Compliant: Chemicals stored inside within secondary containment.
Standard Operating Guidelines:
Follow the Facility’s SOGs during chemical delivery.
Inspect chemical containment multiple times per day.
If a leak or spill is detected, implement the appropriate response per Facility SOGs.
a. Corrective Action(s):
2020: None
2021: None
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
3
Standard: Tracking controlled at all entries, exits, and within parking areas.
Site Components and Compliance Assessment:
Buildings, Sheds, and Parking Areas
Compliant: Primary entries, exits, and parking areas are paved with asphalt and
controlled by a control gate and perimeter fencing. A few un-stabilized access points
exist; however, are only used during infrequent or emergency operations.
Standard Operating Guidelines:
Sweep impacted paved areas if noticeable accumulation of tracked debris occurs.
Corrective Action:
2020: None
2021: None
Standard: Spill kits stocked with instructions, disposal bags, PPE, absorbents, and inlet barriers.
Site Components and Compliance Assessment
Primary Building
Compliant: Chemicals rooms and the garage have spill kits.
Standard Operating Guidelines:
Inspect and purchase missing from spill kit on an as-needed basis.
Corrective Action(s):
2020: None
2021: None
Standard: Preventative maintenance performed on vehicles and equipment.
Site Components and Compliance Assessment
Water Treatment Plant Equipment and Vehicles
Compliant: Inspected and maintained regularly, documentation in place.
Standard Operating Guidelines:
Visual inspection of all vehicles and equipment before use.
Complete minor and preventative maintenance in the garage.
Complete significant repairs at the Vehicle Maintenance Facility.
Document inspections, maintenance, and repairs per Division specific guidelines.
Corrective Actions:
2020: None
2021: None
Standard: Vehicles and equipment washed in designated locations.
Site Components and Compliance Assessment
Main Parking Area (south of building)
Compliant: Occasional car washing occurs; however, activity is infrequent and
insignificant.
Standard Operating Guidelines:
Wash vehicles indoors at the Vehicle Maintenance if a noticeable amount of pollutants
are present.
Corrective Action(s):
2020: None
2021: None
Standard: Maintain stormwater facilities.
a. Site Components and Compliance Assessment:
Compliant: 1500’ of pipe, ten inlets, six manholes and two stormwater basins exist and
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
4
were added to the maintenance schedule in 2020. Maintenance operations program
developed. Annual mowing was completed in the surface detention facility during the fall
of 2021.
b. Standard Operating Guidelines:
Inspect and clear overgrown vegetation from stormwater basins annually.
Inspect and clean underground infrastructure every five-years.
c. Corrective Actions:
2020: Develop asset management program, add infrastructure to the maintenance
district map to facilitate operations.
2021: None
8.0 SPILL RESPONSE PLAN
The City’s typical Spill Response Plan is followed for minor spills in the parking area. Because of the
chemical storage and trained staff, details about the sizes of spills, incident command, and types of
response can be found in the Hazard Communication, Emergency Response Plan, and applicable
documents stored onsite.
9.0 TRAINING
Staff receives training related to this Facility per the requirements within the City’s MS4 Permit and
maintains training documentation in the SWMP.
10.0 INSPECTIONS
Stormwater staff completes an annual facility inspection and reports the results to the Program
Coordinator who will determine compliance with the City’s Facility Minimum Standards listed in the
SWMP. Updates to this FSWPPP were based on the results from:
2020: Completed on November 17
2021: Completed on September 20
11.0 INFRASTRUCTURE IMPROVEMENTS
Staff identified the following project need and plans to propose to the City Commission during the
development of future Capital Improvement Plans (CIP):
a. 2020: None
b. 2021: None
12.0 RECORD KEEPING AND REPORTING
Staff store copies of this FSWPPP at the Water Treatment Plant and the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
5
Appendix A: Site Map
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Curb and Concrete Slurry Capture
December 22, 2021
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during curb and concrete cutting
(Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
Leader: John Vandelinder – Streets Superintendent
Leader: John Alston - Water, Sewer, and Storm Superintendent
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 ACTIVITY DESCRIPTION
The Activity includes concrete cutting and removal. Removal of waste includes the capture of liquid
concrete slurry.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
pH: Portland cement has high pH and is mobilized when concrete is cut
Total Suspended Solids (TSS): Sediments within the slurry or carried up from the substrate
below
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation. All
standards are listed in the City’s Stormwater Management Plan.
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture,
contain, and allow the disposal of generated pollutants, and treat dewatering flows
to remove sediment to the maximum extent practicable before entering the storm
sewer system or waterways.
a. Standard Operating Guidelines:
Clean affected street surfaces and storm sewer infrastructure once operations are
complete
Crews generated less than a gallon of slurry when cutting concrete. Sites were worked
and cleaned in favorable weather, leaving no pollutants in the right of way.
Use quick gel and shovel or wet vac if a large project is proposed
b. Corrective Action(s):
None. Use quick gel and shovel or wet vac if a large project is proposed.
5.2 Standard: Capture and dispose concrete waste
Standard Operating Guidelines:
Haul concrete waste and stage it separately from fill or other materials, or dispose
of concrete directly from the job site
Crews staged concrete in a bin or took it to the appropriate section of the landfill
Corrective Action(s):
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
None
6.0 TRAINING
Staff receives training related to this Activity per the requirements within the City’s MS4 Permit
and training is documented in the SWMP.
7.0 RECORD KEEPING AND REPORTING
Staff stores copies of this FSWPPP at the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Emergency Water Main Break
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during Emergency Water Main
Breaks (Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
Leader: John Alston - Water, Sewer, and Storm Superintendent
3.0 ACTIVITY DESCRIPTION
The Activity includes water main excavation, dewatering, repair, cleanup, and site restoration.
Water and Sewer Division SOGs also exist for this Activity.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
Total Suspended Solids (TSS): Sediments from pressurized washout and dewatering.
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation:
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture, contain,
and allow the disposal of generated pollutants, and treat dewatering flows to remove
sediment to the maximum extent practicable before entering the storm sewer system or
waterways.
Standard Operating Guidelines:
Reduce flows to water main as soon as possible by operating valves.
Direct dewatering discharges to permeable area (park or field), when available. If
not, place multiple weighted wattles in the curb line above impacted inlets.
Sweep affected streets and clean storm sewers once the main is repaired.
Corrective Action(s):
Replace rock bags with manufactured weighted wattles.
5.2 Standard: Cover or contain material stockpiles.
Standard Operating Guidelines:
Excavate soil and place directly into dump trucks and dispose of the materials offsite.
Hydro-excavate soils and dispose of the materials offsite.
Corrective Action(s):
None
5.3 Standard: Contain or stabilize disturbed areas within 14 days of activities.
Standard Operating Guidelines:
Stabilized disturbed area with asphalt surfacing, temporary packed road base, steel
plat cover, or low to grade backfill.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
Corrective Action(s):
None
5.4 Standard: Capture and dispose concrete waste.
Standard Operating Guidelines:
Capture all concrete washout in an enclosed container or within the excavation.
Corrective Action(s):
Purchase concrete washout bags and stage in vehicles.
6.0 TRAINING
Applicable staff review annually using the City’s training software.
7.0 RECORD KEEPING
Stored in the City’s electronic files and training software.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Parks Mowing
December 20, 2021
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating Guidelines (SOGs)
to mitigate stormwater pollutants generated while mowing City Parks (Activity).
2.0 STORMWATER TEAM
The following Staff members are responsible for this ASWPPP’s implementation:
Leader: Thom White, Parks Superintendent Division Manager
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 ACTIVITY DESCRIPTION
The Activity includes Parks staff conducting mowing within City Parks.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
Nitrogen: Organic material, soil ammendment, mulch
Phosporus: Organic material, soil ammendment, mulch
Floatables: Dry grass
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation. All standards are listed
in the City’s Stormwater Management Plan.
Standard: Protect street surfaces and inlets by deploying controls that capture, contain, and allow the
disposal of generated pollutants.
a. Standard Operating Guidelines:
If significant grass clippings are discharged to the street or curb, call a street sweeper or blow the
clippings back onto a mowed area.
Use high quality mowers designed to mulch in place rather than discharge to the side.
b. 2021 Assessment:
Crews were trained on high-end mowers, with fewer seasonal employees than in the past. Regular
mowing resulted in clippings being mulched in place with insignificant amounts of clippings
migrating onto the road or curb.
Compliant
b. Corrective Action(s):
2021: None
Standard: Implement tracking controls to prevent the offsite migration of debris
Standard Operating Guidelines:
Vehicles and equipment are designed for low pressure on the ground. If there are disturbed
areas in a Park, mowers avoid them.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
2021 Assessment:
Crews kept vehicles and equipment on stabilized surfaces and they used street sweepers to
clean debris in the curb line and around the excavation.
Compliant
Corrective Action(s):
None
Additional considerations for soil amendments
Standard Operating Guidelines:
Do no apply soil amendments to natural areas, watercourse setbacks, or stormwater facilities.
Follow all manufacturers guidelines surrounding the timing and rate of application.
2021 Assessment:
Crews followed standard guidelines, resulting in an efficient application of soil amendments.
These procedures should keep excess nutrients out of stormwater runoff.
Compliant
Corrective Action(s):
None
6.0 TRAINING
Staff receives training related to this Activity per the requirements within the MS4 Permit and maintains
training documentation in the SWMP.
7.0 RECORD KEEPING AND REPORTING
Copies of the plan are stored at the City Shops Facility and the Stormwater Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Roadway Traction Sand Application
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during roadway traction sand
application (Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
a. City Leader: John Vandelinder, Streets Superintendent
b. MSU Leader: EJ Hook, Director of Facilities Services
3.0 ACTIVITY DESCRIPTION
The Activity includes the application of sand to roads for vehicle and pedestrian traction during
snow and freezing weather patterns. The City implements year-round street sweeping and storm
sewer maintenance programs, in large part focused on picking up applied road sand.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
a. Total Suspended Solids (TSS): Road sand
b. Magnesium and Sodium Chlorides: Road sand mixtrues contain approximatly 10% sodium
chloride and minor amounts of Magnesium Chloride to promote use and application.
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation:
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture, contain, and
allow the disposal of generated pollutants.
a. Standard Operating Guidelines:
Apply traction sand at an appropriate rates and locations as directed by management.
Inspect equipment to ensure proper application rates are occuring.
Inspect Magnesium Chloride tanks for cracks and leaks.
Notify management of any equipment issues upon identification.
b. Corrective Action(s):
None
6.0 TRAINING
Applicable staff review annually using the City’s training software.
7.0 RECORD KEEPING
Stored in the City’s electronic files and training software.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Activity Stormwater Pollution Prevention Plan
Sanitary Sewer Overflows
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during Sanitary Sewer
Overflows (Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
City Leader: John Alston, Water, Sewer, and Storm Superintendent
MSU Leader: EJ Hook, Director of Facilities Services
3.0 ACTIVITY DESCRIPTION
The Activity includes clearing the sewer obstruction and cleaning affected infrastructure. Water
and Sewer Division SOGs also exist for this Activity.
4.0 POLLUTION IDENTIFICATION
Following is a list of pollutants generated during this Activity:
E. Coli: Municipal wastewater/sewage
Floatables: Municipal wastewater/sewage
Nutrients: Municipal wastewater/sewage
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this Activity:
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture, contain,
and allow the disposal of generated pollutants
Standard Operating Guidelines:
Clean sewage and wash-waters from impacted storm sewers during and post-event.
Wash sanitary sewage from the street once the blockage is cleared.
Dispose of collected sewage at the Vehicle Maintenance Facility’s dump station.
Contact County Health and MDEQ and follow provided mitigation measures.
Corrective Action(s):
None
6.0 TRAINING
Applicable staff review annually using the City’s training software.
7.0 RECORD KEEPING
Stored in the City’s electronic files and training software.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Sidewalk and Curb Construction
December 30, 2021
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during concrete sidewalk,
driveway and curb construction (Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
Leader: John Vandelinder, Streets Superintendent
Leader: John Alston - Water, Sewer, and Storm Superintendent
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 ACTIVITY DESCRIPTION
The Activity includes replacing concrete surfaces which have deteriorated, need regrading, or have
to be removed for utility work. The City only constructs small concrete patches, larger jobs are
contracted out.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
pH: Portland cement within the concrete mix has high pH, and is mobile until it cures.
Total Suspended Solids (TSS): Sediments from concrete aggregate and underlying
materials.
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation. All
standards are listed in the City’s Stormwater Management Plan.
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture,
contain, and allow the disposal of generated pollutants, and treat dewatering flows
to remove sediment to the maximum extent practicable before entering the storm
sewer system or waterways.
a. Standard Operating Guidelines:
Finish pouring concrete in one day, clean job site when complete
Construct concrete sidewalk, driveway, or curb and gutter when the weather will not
produce runoff
b. Corrective Action(s):
2021: None. A larger washout and portable washouts will be made available to ensure
a thorough cleanup. Crews mix and pour small concrete jobs, avoiding the mixing of
excess concrete.
5.2 Standard: Cover or contain material stockpiles
a. Standard Operating Guidelines:
Little material is moved in a typical concrete project. Excavate soil or concrete and
place directly into dump trucks and dispose of the materials offsite. Only the needed
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
amount of fill is dispensed from the dump truck.
b. Corrective Action(s):
2021: None
5.3 Standard: Implement tracking controls to prevent the offsite migration of debris
Standard Operating Guidelines:
Vehicles and equipment shall travel on stabilized surfaces
Sweep sediment from all affected impervious areas and dispose of the materials
offsite
Corrective Action(s):
2021: None
5.4 Standard: Capture and dispose concrete waste
Standard Operating Guidelines:
Only mix the amount of concrete needed for the job.
Capture any concrete washout in a temporary or permanent washout.
Corrective Action(s):
2021: None. Stormwater staff suggests purchasing additional concrete washout
bags to stage in vehicles, and to build a lined washout for any scheduled large
projects.
6.0 TRAINING
Staff receives training related to this Activity per the requirements within the City’s MS4 Permit
and maintains training documentation in the SWMP.
7.0 RECORD KEEPING AND REPORTING
Staff stores copies of this ASWPPP at the Stormwater Division’s Office.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Solid Waste Collection
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during routine solid waste
collection (Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
a. City Leader: Kevin Handelin, Solid Waste Superintendent
b. MSU Leader: EJ Hook, Director of Facilities Services
3.0 ACTIVITY DESCRIPTION
Collection of solid waste from inidivdual containers and transport to the landfill for disposal.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
a. Floatables: Typical garbage items that do not fit or stay within the receptacle.
b. Various Chemical: Leaking household/commercial chemicals and pollutants.
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation:
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture, contain,
and allow the disposal of generated pollutants.
a. Standard Operating Guidelines:
Visually inspect cans, dumpsters, and equipment for leaks, spills, and dangerous
fluids/materials. If identified, report to your supervisor immediately, who will
contact the appropriate agency for response and clean-up (City Vehicle Maintenance
or City Fire - HazMat).
Inspect for rusty, broken, or damaged cans and dumpsters. If identified, leave in
place and notify your supervisor, who will develop a plan for removal and
replacement. Moving or lifting a cracked can or dumpster could result in a large
and uncontrollable spill.
Upon route completion, haul solid waste directly to the Gallatin County Landfill for
disposal.
Maintain a spill kit at the Solid Waste Facility that can be deployed, as necessary.
b. Corrective Action(s):
None
6.0 TRAINING
Applicable staff review annually using the City’s training software.
7.0 RECORD KEEPING
Stored in the City’s electronic files and training software.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Tree Planting, Pruning and Removal
December 30, 2021
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during tree planting, pruning, and
removal (Activity).
2.0 STORMWATER TEAM
The following Staff members are responsible for this ASWPPP’s implementation:
Leader: Alex Nordquest, Forestry Division Manager
Offsite Coordinator: Adam Oliver, Stormwater Program Coordinator
3.0 ACTIVITY DESCRIPTION
This Activity covers City forestry staff activities involving tree planting, pruning, and removal
activities at City properties including facilities, parks, and street boulevards. Tree planting involves
creating a small disturbance area during the digging of the tree hole, planting the tree, and adding
fertilizers/ soil amendments to the newly planted area. Tree pruning and removal activities involve
the removal of overgrown vegetative material or complete trees from City properties. Vegetative
material and debris are disposed of properly at the East Gallatin Storage Facility.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
Nitrogen: Organic material, soil amendments, fertilizers, mulch
Phosphorus: Organic material, soil amendment fertilizers, mulch
Potassium: Soil amendments and fertilizers, mulch
Hydrocarbons: Equipment fuels
Floatables: Fine woody debris, sawdust
Total Suspended Solids (TSS): Soils
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation. All
standards are listed in the City’s Stormwater Management Plan.
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture,
contain, and allow the disposal of generated pollutants.
a. Standard Operating Guidelines:
Finish tree activities in one day, clean job site when complete
Use hand sweeping tools to clean up sediment from the street surfaces. If necessary,
coordinate with the City street sweeper vehicle to clean streets after larger jobs.
Increase frequency of street sweeping based on rainy weather conditions
b. Corrective Action(s):
2021: None
5.2 Standard: Cover or contain material stockpiles
a. Standard Operating Guidelines:
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
Little material is used during these tree activities. Excavated material can typically be
used to refill tree holes. If large amounts of materials are generated, excavated soil will
be immediately and directly placed into containers and disposed of properly offsite.
b. Corrective Action(s):
2021: None
5.3 Standard: Contain or stabilize disturbed areas within 14 days of activities
a. Standard Operating Guidelines:
Minimize disturbance areas during tree planting and removal activities
Stabilized disturbed areas immediately following tree activities using mulch or
b. Corrective Action(s):
2021: None
5.4 Standard: Implement tracking controls to prevent the offsite migration of debris
Standard Operating Guidelines:
Vehicles and equipment shall travel on stabilized surfaces
Sweep sediment from all affected impervious areas and dispose of the materials
offsite
Corrective Action(s):
2021: None
6.0 TRAINING
Staff receives training related to this Activity per the requirements within the City’s MS4 permit
and maintains training documentation in the Stormwater Management Plan (SWMP).
7.0 RECORD KEEPING AND REPORTING
Copies of this ASWPPP are located at the Forestry Office and the Stormwater Office. This ASWPP
is also stored in the City’s electronic files and training software.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1
Activity Stormwater Pollution Prevention Plan
Trenching and Excavation
1.0 OVERVIEW
This Activity Stormwater Pollution Prevention Plan (ASWPPP) includes Standard Operating
Guidelines (SOGs) to mitigate stormwater pollutants generated during trenching and excavation
(Activity).
2.0 STORMWATER TEAM
The following Staff member is responsible for this ASWPPP’s implementation:
3.0 ACTIVITY DESCRIPTION
The Activity includes water main excavation, dewatering, infrastrucutre repair or installation,
cleanup, and surface restoration.
4.0 POLLUTION IDENTIFICATION
Following is a list of stormwater pollutants generated during this Activity:
5.0 STANDARDS ASSESSMENT
Section 5.0 outlines the City’s Activity Minimum Standards applicable to this operation. All
standards are listed in the City’s Stormwater Management Plan.
5.1 Standard: Protect street surfaces and inlets by deploying controls that capture, contain, and
allow the disposal of generated pollutants, and treat dewatering flows to remove sediment
to the maximum extent practicable before entering the storm sewer system or waterways.
Minimize the limits of disurbance to the extent practical.
Direct dewatering discharges to permeable area (park or field), when available. If not,
place multiple weighted wattles in the curb line above impacted inlets.
Sweep affected streets and clean storm sewers once the main is repaired.
Replace rock bags with manufactured weighted wattles.
5.2 Standard: Cover or contain material stockpiles
Excavate soil and place directly into dump trucks. Dispose of the materials offsite.
Hydro-excavate soils and dispose of the materials offsite.
None
5.3 Standard: Contain or stabilize disturbed areas within 14 days of activities
Stabilized disturbed area with asphalt surfacing, temporary packed road base, steel plat
cover, or low to grade backfill.
None
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2
5.4 Standard: Implement tracking controls to prevent the offsite migration of debris
Limit vehicle and equipment travel to stabilized surfaces.
Sweep or vac sediment from all affected roads and dispose of the materials offsite.
None
5.5 Standard: Capture and dispose concrete waste
Remove concrete from excavation and stage separately from other fill materials.
Capture all concrete washout in an enclosed container or within the excavation.
Purchase concrete washout bags and stage in vehicles.
6.0 TRAINING
Applicable staff review nnnually using the City’s training software.
7.0 RECORD KEEPING
Stored in the City’s electronic files and training software.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Attachment B:
High-Priority Post Construction Facility Inspections
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: DP.H04.00006 Facility Type: Surface Detention
Date/Time: 6/25/2021 0900
Owner: Bozeman School District Contact: Matthew Stark, Gary Cuchine
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: Parking lot off 11th by the service building
Type of Inspection: High Priority
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: ~0.1” overnight
Temperature: 55°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: N/A
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 6/25/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes ☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes ☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes ☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes ☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes ☒ No Damp, but drained down within 24 hrs
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes ☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes ☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☒ No
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No
Mowing, integrated with surrounding landscape. Outfall area is
natural, not mowed.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 0
Grasses/Herbaceous 100
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 1.24 4793 Outlet structure lid
SRV#1
Inlet 3.5 4790.74 Curb cuts, =/- 0.1’
SRV#2
Outlet 4.71 4789.53 Invert from basin
SRV#3
Center 3.99 4790.25
SRV#4
North of Center - -
SRV#5
East of Center 4.48 4789.76
SRV#6
South of Center - -
SRV#7
West of center 3.98 4790.26
SRV#8
Berm or overflow 3.3 4790.94 Approximate high point
SRV#9 4.91 4789.33 Invert within outlet structure, outlet side
Summary
The site appeared to be in the same condition as last year. I did not shoot any elevations, will perform that task again next
year.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview. Control point is foreground, outlet structure
rim. (west view)
Image 2
Outlet structure. Flow is from top of photo, to tee, bottom of photo
to outfall. (close-up)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Outfall is below long grass at upper left of photo. (east view)
Image 4
Curb cuts leading to facility. This facility also accepts flow from the south
and west fields. (south view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 7 2021
Image 5
Evidence of high flows since last year. Slight debris in outlet
structure.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2020
Section 1: General Information
Facility ID: TBD, west of the green tennis court Facility Type: Surface Detention
Date/Time: 6/25/2021 0915
Owner: Bozeman School District Contact: Matthew Stark, Gary Cuchine
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: Tennis court parking lot
Type of Inspection: High Priority
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: ~0.1” overnight
Temperature: 55°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: N/A
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 6/25/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2020
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes ☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes ☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes ☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes ☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes ☒ No Damp, but drained down within 24 hrs
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes ☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes ☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☒ No
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No
Less frequent mowing in the basin. No signs of debris or trash
buildup. Outfall area is natural, planted saplings, no signs flow from
the basin.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2020
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 5
Aquatics 0
Grasses/Herbaceous 90
Trees >3” DBH 5
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 3.05 4798 From Infrastructure contours. H.I. = 4801.05
SRV#1
Inlet 6.62 4794.43 Invert at trash rack, inlet from southwest
SRV#2
Outlet 6.88 4794.17 Rim
SRV#3
Center 7 4794.05
SRV#4
North of Center 3.19 4797.86 West curb cut, flow line
SRV#5
East of Center 7.09 4793.96
SRV#6
South of Center 3.7 4797.35 East curb cut, flow line
SRV#7
West of center 6.97 4794.08
SRV#8
Berm or overflow 5.1 4795.95 On gravel
SRV#9 5.9 4795.15 Inlet from south
Summary
The site appeared to be in the same condition as last year. I did not shoot any elevations, I will repeat that task next year.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2020
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2020
Section 7: Photo Log
Image 1
Curb cut. (northwest view)
Image 2
Facility overview. (east view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2020
Image 3
Slotted manhole, leads to basin at center of photo. Parking lot drains
from curb cut by the birch tree at upper right. (northeast view)
Image 4
Second inlet from south. (south view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 7 2020
Image 5
Overflow channel of gravel and asphalt leading to Mandeville Creek. (east
view)
Image 6
Overflow channel and outfall. (southeast view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
September 9, 2021
Attn: Kim A. Center, Registered Agent
Bridger Creek Subdivision Community Association, Inc.
PO Box 4592
Bozeman, MT 59772
RE: Bridger Creek Subdivision High-Priority Stormwater Facility Inspection
Kim Center,
Bridger Creek Subdivision Community Association is responsible for the maintenance of
a stormwater facility the City of Bozeman has deemed as a high-priority due to its size
and discharge location. Stormwater facilities are engineered systems designed to
capture, store, infiltrate, and release urban runoff to local waterways. Unmaintained
stormwater facilities pose a risk to residents, property, and the environment by
increasing the chance of urban flooding and waterway pollution. As such, the City
completes annual inspections of high-priority facilities.
On September 1st, 2021, Stormwater Division personnel completed an inspection of the
Bridger Creek Subdivision Community Association facility and have compiled the
following information for your review:
1. Bridger Creek Stormwater Facility Map
2. Stormwater Facility Inspection Report, including findings and maintenance items
3. Stormwater Facility Maintenance Guide
In summary, we have identified the following issues during the inspection:
1. The stormwater facility contains sediment, overgrown dead and dying vegetation,
and excessive live vegetation which may prevent stormwater from accessing the
outlet structure.
2. Stormwater capacity may be reduced over time, and potentially negatively affect
detention time (increasing flood risk and erosion) and downstream water quality
of the East Gallatin River.
The City asks that Bridger Creek Subdivision Community Association submit a plan for
maintenance of these issues.
I am available to answer questions regarding this letter and the attached information
and can be reached at rsmith@bozeman.net or 406-582-2937.
Regards,
Russ Smith, Stormwater Program Technician
Russ Smith
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
#*
")
")
")
")
")
")
&-
&-
BO
Y
L
A
N
R
D
Legend
&-Outfall
")Inlet
#*Outlet Structure
Pipe
Parcels
HOA Facility
High-Priority Stormwater InspectionBridger Creek Subdivision ±
Map created by the City of Bozeman Stormwater Division on 9/2/2021 and is intended for planning purposes only.
Stormwater Facility 1
Stormwater Ditch 1
Stormwater Ditch 2
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: DP.E01.00007 Facility Type: Surface Detention
Date/Time: 11:30 9/1/2021
Owner: Bridger Creek HOA Contact: Kim Center – registered agent ( Sharyn Anhalt,
previous)
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: Boylan Rd, apex. Access off road
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: High Priority
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0”, 48+ hrs
Temperature: 62⁰ F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: 5+ gpm flowing into impoundment from southerly ditch.
Section 3: Facility Maintenance Priority
☐ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☒ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: 9/1/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☒ Yes
☐ No
(1) Significant sediment within pond
Remove excess sediment around inlet and outlet
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☒ Yes
☐ No
(1) Significant live plant matter, dead plant matter & overgrown
vegetation in and around pond.
Reduce excess vegetation that impedes flow or reduces volume
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☒ Yes
☐ No
(1) Irrigation box inside of inlet, irrigation pipe inside culvert
Monitor outlet grate condition for sufficient conveyance
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☒ Yes ☐ No
(1) Reduced capacity inside storage impoundment
See Section 1.3
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☒ Yes
☐ No Standing water throughout
2.4 Flow Path Clogged or obstructed flow path? ☒ Yes
☐ No
(1) Significant obstructions in flowpath
See Section 1.3
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☒ No
Please submit a written plan that addresses long term maintenance
of increased vegetation growth
3.2 Implementation Is there evidence of maintenance? ☐ Yes
☒ No Mowing outside the pond perimeter
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Open Water 25
Aquatics 55 Cattails are rapidly encroaching into pond
Grasses/Herbaceous 10
Trees >3” DBH 5 Aspen trees once colonized into pond and then died from inundation, are a dominant characteristic
Shrubs
5
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
CP
San Swr Lid 22+87.66 9.42 4703.0 Backsight control elevation inferred from design plans; may vary from actual.
SP01
Inlet Grate 10.29 4702.13 Grate at west side, street curb level at Boylan Rd
SP02
Inlet Pipe Invert 13.39 4699.03 RCP apron in dense vegetation; irrigation control box in flowpath
SP03
WSE 12.67 4699.75 Pond water surface elevation
SP04
NW Topo Low 11.74 4700.68 Low area NW of pond bank (potential overflow)
SP05
Outlet Structure
Invert
12.05 4700.37 8” PVC invert interior of outlet CMP
SP06
Outlet Top of Grate 11.11 4701.31 Grate elevation top of vertical CMP
SP07
Outfall Invert 12.12 4700.30
8” PVC invert at outfall
SP08
South Topo Low 10.74 4701.68 Low area south of outlet works (potential overflow)
Summary Geometry and volume of impoundment are similar to that in design documentation. Basin bottom elevation is likely lower
than originally specified. Increasing vegetative growth may reduce capacity over time.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Detention pond (west view); standing water, dead and decadent tree and
shrub vegetation layer.
Image 2
Inlet from road CMP; abundance of vegetation clogging structure.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Outlet structure; clogged with vegetation.
Image 4
Outlet structure; notched weir closeup.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
1 - Version 5 September 7, 2021
Stormwater Facility Maintenance Guide
What is a stormwater facility?
A stormwater facility is an engineered depression constructed to
capture and treat polluted stormwater flowing from roads,
parking lots, and driveways. Maintenance of stormwater facilities
is necessary to ensure their proper function, reducing negative
impacts on local waterways and flooding.
What is the benefit of a stormwater facility?
A stormwater facility:
Controls the rate of stormwater runoff flowing into streams, reducing flooding and erosion.
Removes stormwater pollutants, such as sediment, fertilizers, pet waste, metals, and oils,
protecting the public and the environment.
Who is responsible for stormwater facility maintenance?
Typically, the City requires developers to create and implement a stormwater facility maintenance
plan when constructing a subdivision or property. Home Owner Associations (HOAs) assume
responsibility when the subdivision changes ownership, and the developer is no longer involved.
How do I maintain a stormwater facility?
The City recommends HOAs complete the following:
Compile relevant documents, such as infrastructure plans, maintenance plans, and contracts.
Complete a facility inventory, documenting facility location, and condition information.
Develop a comprehensive plan, including budget, inspection frequency, and a record-keeping
process. Assistance from a qualified professional may be helpful.
Important stormwater facility characteristics to consider include:
Capacity: Excess vegetation and sediment reduces capacity and affects performance.
Soil infiltration: Compaction and accumulated sediment reduce infiltration rates, resulting in
stagnant, standing water that can breed mosquitos and algae.
Vegetation height: 6” or taller reduces flow velocity and provides water treatment.
Images 2 through 5 show the results of inadequate stormwater facility maintenance.
Image 1 - Stormwater Basin
Image 2 - Overgrown vegetation Image 3 - Erosion causing channelized flow
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
2 - Version 5 September 7, 2021
Recommended Maintenance Strategy
HOAs should complete routine inspections and maintenance to
ensure a stormwater facility functions as designed, reducing
pollution, costly repairs, and flood risks. The City recommends the
following maintenance strategy:
1. Routine Maintenance Activities (1-3 Months)
Designate “no-cut zones” in the bottom of the facility
Remove trash, leaves, grass clippings, and debris
Establish a chemical-free zone in and around the facility
Inspect for uniform ponding, and that water disappears three
days after rain events
2. Annual Maintenance Activities (Annually)
Cut vegetation to 6” in fall, remove clippings
Re-establish vegetation on eroded and barren areas
Remove excess sediment buildup
Update maintenance plan and inspection log
3. Long-Term Maintenance Activities (10-15 Years)
Consult a qualified professional to inspect and return the
facility back to its initial design and capacity
Dredge facility if sediment buildup is greater than 6”
Re-establish vegetation along the facility’s banks and bottom
Contact Information
It is important HOAs maintain their stormwater facilitys to ensure
Bozeman continues to be “The Most Livable Place”. Please contact the Stormwater Division for
more information or to schedule a voluntary inspection.
Adam Oliver Russ Smith
Stormwater Program Coordinator Stormwater Project Technician
406-582-2916 406-582-2937
aoliver@bozeman.net rsmith@bozeman.net
Image 4 - Obstructed inlet pipe Image 5 - Water 3-days after rain event
Image 6 – No cut zone
Image 8 – Long-Term Maintenance
Image 7 – Annual Maintenance
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: DP.H02.00001 (Kenyon Noble DP2) Facility Type: Surface Detention
Date/Time: 9/1/2020 12:15
Owner: Kenyon Noble Contact: Jayson Thompson, 406-556-2912, 406-595-3687
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: Call Jayson prior to visit as necessary
Type of Inspection: High priority, overflows to Mandeville Creek
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0”, 48+ hrs
Temperature: 68⁰ F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: Please see italicized maintenance items in section 4.
Section 3: Facility Maintenance Priority
☐ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk
of flooding, waterway pollution, and infrastructure failure.
☒ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: 9/1/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☒ Yes
☐ No
(1) Dense cattails. This is usually a sign of standing water.
Remove excess vegetation that is blocking the flow path to the
outlet pipe.
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☐ No Did not observe
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☒ Yes ☐ No
(1) West side of facility has visible sediment or fill.
Remove sediment to regain original capacity of the stormwater
basin.
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☐ No N/A Did not observe, but cattails indicate stagnant water.
2.4 Flow Path Clogged or obstructed flow path? ☒ Yes
☐ No See 4.1.3 Vegetation (above)
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☒ No
3.2 Implementation Is there evidence of maintenance? ☐ Yes
☒ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 5 Recently placed or disturbed soil in the northwest corner.
Aquatics 75 Heavy overgrowth of cattails choking inlet and outlet structures.
Grasses/Herbaceous 20
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 4.56 4727.00
SRV#1
Inlet 6.75 4724.81
SRV#2
Outlet 7.64 4723.92
SRV#3
West of Center 7.36 4724.20
SRV#4
Center 7.42 4724.14
SRV#5
East of Center 7.42 4724.14
Summary
Bottom is uniform, but northwest corner appears to be filled in; aerial images confirm.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
CP
*1
*2 *3 *4 *5
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview (west view).
Image 2
Inlet pipe with accumulated sediment.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Inlet pipe location (at survey stadia); note heavy overgrowth of detention
basin.
Image 4
Northwest corner of detention basin. Note fill on right, likely from snow
removal and storage efforts (south view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: HP Stormwater Facility #1 (DP.H06.00026) Facility Type: Surface Detention
Date/Time: 8/31/2021 13:06
Owner: MSU Contact: EJ Hook, edward.hook1@montana.edu
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: Roskie parking lot
406-994-7840
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0”, 48+ hrs
Temperature: 75⁰ F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___8/31/21_______
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☒ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No Draft
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No mowing
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground <5
Aquatics 0
Grasses/Herbaceous 95
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point
SRV#1
Inlet
SRV#2
Outlet
SRV#3
Center
SRV#4
North of Center
SRV#5
East of Center
SRV#6
South of Center
SRV#7
West of center
SRV#8
Berm or overflow
SRV#9
Summary It does not appear that any sedimentation or changes in geometry have occurred since this site was last surveyed; did not
measure elevations.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview. (East view)
Image 2
Emergency overflow. (West view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Facility inlet/outlet. Small amounts of sediment in pipe.
Image 4
Cobble reinforced emergency spillway.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: HP Stormwater Facility #2 (DP.H06.00400) Facility Type: Surface Detention
Date/Time: 8/31/2021 13:00
Owner: MSU Contact: EJ Hook, edward.hook1@montana.edu
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: Parking by greenhouse
406-994-7840
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0”, 48+ hrs
Temperature: 74⁰ F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___8/31/21_______
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No Draft
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No mowing
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 0
Grasses/Herbaceous 100
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point
SRV#1
Inlet
SRV#2
Outlet
SRV#3
Center
SRV#4
North of Center
SRV#5
East of Center
SRV#6
South of Center
SRV#7
West of center
SRV#8
Berm or overflow
SRV#9
Summary It does not appear that any sedimentation or changes in geometry have occurred since this site was last surveyed; did not
measure elevations.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
Confirm outlet structure and appx width
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview. (East view)
Image 2
Outlet structure sump with debris. (Close-up)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: HP Stormwater Facility #3 (DP.H06.00024) Facility Type: Surface Retention
Date/Time: 8/31/2021 12:42
Owner: MSU Contact: EJ Hook, edward.hook1@montana.edu
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: East end of Deer St (off S 13th Ave)
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0” 48+hrs
Temperature: 73 ⁰F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___8/31/21_______
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No Draft
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No Recent Mowing
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 0
Grasses/Herbaceous 95
Trees >3” DBH 5 perimeter
Shrubs
0
Total
100 The facility bottom is uniform and well maintained.
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point
SRV#1
Inlet
SRV#2
Outlet
SRV#3
Center
SRV#4
North of Center
SRV#5
East of Center
SRV#6
South of Center
SRV#7
West of center
SRV#8
Berm or overflow
SRV#9
Summary It does not appear that any sedimentation or changes in geometry have occurred since this site was last surveyed; did not
measure elevations.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Overview (north view). Basin inlet is at far left hand side of facility,
overflow is toward right.
Image 2
Pond inlet (west view). Small amounts of debris and sediment behind
trash rack.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Overflow with riprap armoring (east view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: HP Stormwater Facility #4 (DP.H06.00023) Facility Type: Surface Detention
Date/Time: 8/31/2021 12:45
Owner: MSU Contact: EJ Hook, edward.hook1@montana.edu
Inspector’s Name, contact info: Russ Smith, Stormwater Project Technician
Location/Access info: from W Garfield and behind Plant Growth Center
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0” 48+ hrs
Temperature: 74⁰ F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk
of flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___8/31/21_______
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☒ Yes
☐ No
(1) Overgrown grass and herbaceous layer potential to constrict
flow. Small infestation of spotted knapweed (Centaurea stoebe).
Routine weed control, mowing and debris removal will address
potential flow restrictions or noxious weed occurrences.
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes
☐ No Draft
3.2 Implementation Is there evidence of maintenance? ☐ Yes
☒ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 10
Aquatics 0
Grasses/Herbaceous 85 Basin appears to be functioning as designed. Vegetation is accumulating in and around trash racks.
Trees >3” DBH 0
Shrubs
5
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point
SRV#1
Inlet
SRV#2
Outlet
SRV#3
Center
SRV#4
North of Center
SRV#5
East of Center
SRV#6
South of Center
SRV#7
West of center
SRV#8
Berm or overflow
SRV#9
Summary It does not appear that any sedimentation or changes in geometry have occurred since this site was last surveyed; did not
measure elevations.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview (northeast view).
Image 2
Outlet structure (northwest view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Inlet apron (southwest view). Overgrown vegetation.
Image 4
Inlet structure (northeast view). Overgrown vegetation.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 7 2021
Image 5
Inlet 2 close-up inside trash rack.
Image 6
Inlet structure facing (northeast view). Overgrown vegetation.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: HP Stormwater Facility #5 (DP.H06.00028) Facility Type: Surface Detention
Date/Time: 8/31/2021 12:30
Owner: MSU Contact: EJ Hook, edward.hook1@montana.edu
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: Across from W Harrison, off S. 11th St.
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 48 Hours +
Temperature: 73 ⁰F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ____ ___________ Date: ___8/31/21_______
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No Draft
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No Recent mowing
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 5
Aquatics 0
Grasses/Herbaceous 95
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point
SRV#1
Inlet
SRV#2
Outlet
SRV#3
Center
SRV#4
North of Center
SRV#5
East of Center
SRV#6
South of Center
SRV#7
West of center
SRV#8
Berm or overflow
SRV#9
Summary
It does not appear that any sedimentation or changes in geometry have occurred since this site was last surveyed; did not
measure elevations.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview (west view).
Image 2
Basin inlet from manhole. 15” HDPE (south view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Outlet structure. Overflow is cobble stone to background (west view).
Image 4
Outfall, 18” HDPE (east view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: HP Stormwater Facility #6 (DP.H06.00025) Facility Type: Surface Detention
Date/Time: 8/31/2021 12:15
Owner: MSU Contact: EJ Hook, edward.hook1@montana.edu
Inspector’s Name, contact info: Russ Smith, Stormwater Program Technician
Location/Access info: Antelope parking lot off S 13th Ave
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0” 48+ hrs
Temperature: 72⁰ F, Smoke haze
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: Recently constructed.
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk
of flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___8/31/21________
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☒ Yes
☐ No
(1) Moderate amount of red clover overgrowing on bottom of basin
Complete routine mowing to avoid flow path restriction.
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☒ Yes
☐ No Mild obstruction of bottom infiltration structure
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☒ Yes ☐ No
(1) Small amount of unvegetated side slopes
Establish vegetation on bare ground area.
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No Draft
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No Perimeter mowing
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 10 Some side slopes not vegetated
Aquatics 0
Grasses/Herbaceous 90 Red clover overgrowing in bottom
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point/ Surface
Outlet Top CMP 6.69 100.00 Control
SRV#1
NW Inlet 8.02 98.67
SRV#2
Bottom Outlet 8.1 98.59
SRV#3
Center 8.11 98.58
SRV#4
Northwest of Center 8.05 98.64
SRV#5
East of Center 8.29 98.40
SRV#6
South of Center 8.18 98.51
SRV#7
Southern Inlet 7.73 98.96
SRV#8
Wier Control 8.48 98.21
SRV#9
PVC Outlet Invert 9.91 96.78
Summary
North pond slope approximately 5.2 : 1
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
CP*
1*
2*
3*
4*
5*
6*
7*
*8 (*9)
5.2 : 1
Slope
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Detention pond overview looking (northeast view). Note bare ground on
top break.
Image 2
Inlet one; note red clover in foreground.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Inlet 2; concrete curb and gutter from Hyalite Hall front parking lot.
Image 4
Surface outlet structure.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 7 2021
Image 5
Outlet structure weir.
Image 6
Drywell; vertical infiltration drain. Note heavy cover of red clover.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 8 2021
Image 7
Retention pond overview looking westward.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: DP.F01.00026 Facility Type: Surface Detention
Date/Time: 7/16/2021 10:30
Owner: SID 674, public easement Contact: Resonon (406) 586-3356
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: Easement or trail at the west end of Commercial Dr.
Type of Inspection: High Priority - EGR
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: Very dry
Temperature: 80°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☐ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☒ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☒ Yes ☐ No
(1) Vegetation has grown in the easement and basin which would
prevent maintenance
Trim back vegetation to allow maintenance access.
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☒ Yes
☐ No
Thick willows and brush in the basin
Remove woody vegetation from the basin to restore capacity and
infiltration functions
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☐ No Unable to determine with the amount of vegetation
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes ☐ No Unable to determine with current conditions
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☒ No
3.2 Implementation Is there evidence of maintenance? ☐ Yes
☒ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 5
Aquatics 5
Grasses/Herbaceous 10
Trees >3” DBH 10
Shrubs
70
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point
SRV#1
Inlet
SRV#2
Outlet
SRV#3
Center
SRV#4
North of Center
SRV#5
East of Center
SRV#6
South of Center
SRV#7
West of center
SRV#8
Berm or overflow
SRV#9
Summary
Unable to survey elevations due to thick vegetation
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Severely overgrown detention basin
Image 2
Looking east at edge of the detention impoundment.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Inlet pipe. Note overgrown vegetation.
Image 4
Outlet channel looking northeast. Note overgrown vegetation.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2020
Section 1: General Information
Facility ID: DP.H07.00022 (SUD #1) Facility Type: Surface Detention
Date/Time: 5/5/2021 9:00
Owner: South University District Contact: CoB
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: Gravel paths by Campus Blvd
Type of Inspection: High priority, Mandeville Creek watershed
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: ________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0.01” <48 hrs
Temperature: 48°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 5/14/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2020
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☒ Yes
☐ No
Trash, mostly located near facility inlet. Image 6.
Remove trash from facility.
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☐ No TBD. Look for Park Plan in internal documents
3.2 Implementation Is there evidence of maintenance? ☒ Yes
☐ No Mowing
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2020
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 0
Grasses/Herbaceous 95
Trees >3” DBH 0
Shrubs
5 Tree species, young, planted
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 6.68 4931 Outlet structure rim
SRV#1
Inlet 8.56 4929.12 invert
SRV#2
Outlet 9 4928.68 Invert leaving facility
SRV#3
Center 9.26 4928.42
SRV#4
North of Center 9.18 4928.5
SRV#5
East of Center - -
SRV#6
South of Center 9.09 4928.59
SRV#7
West of center - -
SRV#8
Berm or overflow 7.92 4929.76
SRV#9 - -
Summary
The site appeared to be in the same condition as last year. I did not shoot any elevations, will perform that task next year.
There is no second inlet from the east as shown in GIS. Check next year for new site construction. Facility Sketch below shows
current conditions.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2020
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2020
Section 7: Photo Log
Image 1
Facility overview. (north view)
Image 2
Outlet from the facility, outlet structure can be seen about ten feet
behind it. (west view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2020
Image 3
Inside the outlet structure.
Image 4
Bottom of facility. (north view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 7 2020
Image 6
Trash and small amount of sediment at facility inlet. (east view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2020
Section 1: General Information
Facility ID: DP.H07.00023 (SUD #2) Facility Type: Surface Detention
Date/Time: 5/5/2021 9:00
Owner: South University District/CoB Contact: Storm, Parks
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: Gravel paths by Campus Blvd
Type of Inspection: High priority, Mandeville Creek watershed
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other:__________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0.01” <48 hrs
Temperature: 48°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 5/14/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2020
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☒ Yes
☐ No
Trash, mostly located near facility inlet. Image 2.
Remove trash from facility.
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☒ Yes
☐ No
Very small pool by facility inlet, possibly from irrigation. >48 hrs
since rainfall. Image 2.
No action needed.
2.4 Flow Path Clogged or obstructed flow path? ☒ Yes
☐ No
Sand bags in outlet pipe. Image 4.
Remove sand bags if they are not being used under an active
SWPPP.
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☒ No Look for Park Plan
3.2 Implementation Is there evidence of maintenance? ☐ Yes
☒ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2020
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 5
Grasses/Herbaceous 95
Trees >3” DBH 0 Planted trees are dead and/or outside of the facility
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 1.41 4939 SD manhole lid south of facility. Elevation estimated from plan contours. H.I.=4940.41
SRV#1
Inlet 9.63 4930.78 Facility inlet invert. 2” of water, likely from irrigation
SRV#2
Outlet 9.8 4930.61 Invert, pipe from facility
SRV#3
Center 9.65 4930.76
SRV#4
North of Center 9.72 4930.69
SRV#5
Outlet structure rim 7.17 4933.24
SRV#6
South of Center 9.22 4931.19
SRV#7
West of center - -
SRV#8
Berm or overflow 8.7 4931.71
SRV#9 - -
Summary
The site appeared to be in the same condition as last year. I did not shoot any elevations, will perform that task next year.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2020
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2020
Section 7: Photo Log
Image 1
Facility overview. (north view)
Image 2
Facility inlet with sediment and trash beginning to accumulate. Overall,
taking a very small amount of volume. (east view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2020
Image 3
Sediment and standing water at facility inlet. (east view)
Image 4
Facility outlet to outlet structure. Sand bags are intact but not meant to be
permanent. There is one phase of construction still to be completed which
leads to this facility. (west view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 7 2020
Image 5
Outfall. (northwest view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: DP.G02.00017 (Tanges #1) Facility Type: Surface Detention
Date/Time: 7/16/2021 11:09
Owner: Tanges Subdivision Contact: Unknown
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: Performed inspection from the N 11th Ave sidewalk.
Type of Inspection: High priority, Mandeville Creek watershed
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: >48 hours, dry weather
Temperature: 60 F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: This facility needs significant vegetation maintenance. Mandeville Creek appears to now be flowing through facility.
In earlier mapping layers, Mandeville Creek flowed to the east of the larger pond and detention facility. Creek flows are now
moving through both ponds.
Section 3: Facility Maintenance Priority
☐ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk
of flooding, waterway pollution, and infrastructure failure.
☒ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 7/16/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☒ Yes
☐ No Ownership and easement are uncertain
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☒ Yes
☐ No Overgrown appearance. Image 1.
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No Outfall structure is submerged and water flowing around it
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No Unable to tell from sidewalk
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☒ Yes
☐ No
Mostly filled with water, need to compare to creek elevation. Image
3.
Determine cause of standing water and remove blockage if possible.
Determine the role of the adjacent stream and pond.
2.4 Flow Path Clogged or obstructed flow path? ☒ Yes
☐ No
Curb inlets are scheduled to be maintained by City crews this year.
Images 1 and 2. If they are under water, they will not be able to be
maintained.
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes
☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☐ Yes
☐ No Unknown
3.2 Implementation Is there evidence of maintenance? ☐ Yes
☒ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 60 water
Aquatics 10
Grasses/Herbaceous 10
Trees >3” DBH 0
Shrubs
20 willows
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point - -
SRV#1
Inlet - -
SRV#2
Outlet - -
SRV#3
Center - -
SRV#4
North of Center - -
SRV#5
East of Center - -
SRV#6
South of Center - -
SRV#7
West of center - -
SRV#8
Berm or overflow - -
SRV#9 - -
Summary
Did not shoot elevations due to thick vegetation.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview, detention facility toward right where curb ends (north
view).
Image 2
Water backed up into inlet structure (close-up view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 3
Water flowing through facility / around outlet structure
Image 4
Standing water in facility (south view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2021
Section 1: General Information
Facility ID: DP.E02.00006 Facility Type: Surface Detention
Date/Time: 9/14/2021
Owner: City of Bozeman Contact: John Vandelinder, 582-3203
Inspector’s Name, contact info: Russ Smith, rsmith@bozeman.net
Location/Access info: From E Griffin Dr. and driveway
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: 0”, >48 + hrss
Temperature: 68°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes:
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk
of flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ____________ Date: Sept 14, 2021 Russ Smith
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2021
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes
☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes
☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes
☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes
☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes
☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☒ Yes ☐ No Pea gravel installed on bottom of pond. Side slopes stabilized.
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No
3.2 Implementation Is there evidence of maintenance? ☒ Yes
☐ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2021
Section 5: Quantitative Analysis
Vegetation
Cover type % Within facility Notes
Bare ground 70 Pea gravel bottom
Aquatics 0
Grasses/Herbaceous 30 Timothy, Poa spp.
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation Analysis
Survey Point Reading (ft) Elevation (ft) Notes
SP01 7.85 4696.00 Top of Grate - Benchmark / Control Point
SP02 10.37 4693.48 Pond 1 FETS outlet Invert
SP03 10.64 4693.21 Pond Bottom Center
SP04 10.66 4693.19 Pond Bottom West
SP05 10.81 4693.04 Pond Bottom East
SP06 10.32 4693.53 Pond 1 Inlet PVC Invert
SP07 10.25 4693.60 Pond 1 Inlet CMP Invert
SP08 10.53 4693.32 Pond 2 FETS inlet
SP09 8.43 4695.42 Pond 1 E. Spillway
SP10 12.00 4691.85 Pond 2 Outlet CMP Invert
SP11 11.91 4691.94 Outfall north of Griffin Rd <1” sediment
Summary
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2021
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2021
Section 7: Photo Log
Image 1
Facility overview. Main pond inlet at foreground (white PVC). Note gravel
installed on bottom of impoundment (northwest view).
Image 2
Primary detention basin with traction control aggregate facility on right;
note concrete barriers and stabilization blanket installed on the break in
slope and pond edge, respectively.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2021
Image 5
Main basin outlet and outlet structure manhole, the control point, visible
above center (east view).
Image 6
Outfall. Grass is tall but the outfall has a clear path to the East Gallatin River
(southeast view).
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2020
Section 1: General Information
Facility ID: DP.I51.00073 Facility Type: Surface Detention
Date/Time: 5/12/2021 13:40
Owner: City of Bozeman Contact: Tom Radcliffe, tradcliffe@bozeman.net
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: WRF, within fenced area
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: >48hrs
Temperature: 59°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: 2021 High Priority Inspection.
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 6/8/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2020
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes ☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes ☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes ☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes ☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No No rain within 48 hours, but no signs of standing water either
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes ☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes ☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2020
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 0
Grasses/Herbaceous 100
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 4.27 4620 MH lid. H.I. = 4624.27. Height from contours on plans.
SRV#1
Inlet 6.4 4617.87 West swale bottom, mowed area
SRV#2
Outlet 6.35 4617.92 PVC invert out of basin
SRV#3
Center 6.9 4617.37
SRV#4
North of Center - -
SRV#5
East of Center 6.7 4617.57
SRV#6
South of Center - -
SRV#7
West of center 6.6 4617.67
SRV#8
Berm or overflow 5.7 4618.57
SRV#9 - -
Summary
This facility is in good condition. There were no apparent changes, so I did not take elevations. I will repeat that task in 2022.
Routine maintenance included fall mowing and spring spot application of pesticide for weeds.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2020
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2020
Section 7: Photo Log
Image 1
Outlet structure and east half of the facility. (south view)
Image 2
West half of the facility. There is a small swale entering from the
background at the left of the photo. (west view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2020
Image 3
Path of potential discharge toward the East Gallatin River. No signs of
flow. (north view)
Image 4
Outlet structure. Outfall is inside the fenced area. (north view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2020
Section 1: General Information
Facility ID: DP.I51.00075 Facility Type: Surface Detention
Date/Time: 5/12/2021
Owner: City of Bozeman Contact: Tom Radcliffe, tradcliffe@bozeman.net
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: WRF, near parking area.
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: >48hrs
Temperature: 59°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: 2021 High Priority Inspection.
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2020
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes ☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes ☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes ☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes ☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No Sediment and cattails, not significant at this time.
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes ☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes ☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2020
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 25
Grasses/Herbaceous 75
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 3.43 4603 MH lid. H.I. = 4606.43. Height from contours on water plans.
SRV#1
Inlet 4.01 4602.42 Curb cut at asphalt height
SRV#2
Outlet 5.7 4600.73 PVC invert out of basin to outlet structure
SRV#3
Center 6.07 4600.36
SRV#4
North of Center - -
SRV#5
East of Center 5.94 4600.49
SRV#6
South of Center - -
SRV#7
West of center 5.92 4600.51
SRV#8
Berm or overflow 4.05 4602.38
SRV#9 - -
Summary
Cattails indicate fines slowing infiltration. Volume is not yet diminished, but this basin will likely need sediment removal
sooner than the others at WRF. There were no apparent changes from last year, so I did not take elevations. I will repeat
that task in 2022 and compare bottom elevation.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2020
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2020
Section 7: Photo Log
Image 1
Facility overview. Curb cut at foreground has been cleaned out since last
year and curbline has been swept. (north view)
Image 2
Basin is mowed up to the boundary with cattails. (south view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2020
Image 3
West half of facility, outlet and outlet structure. (northwest view)
Image 4
Path from outlet structure to outfall. (northwest view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form
Stormwater Facility Inspection Form Page 1 2020
Section 1: General Information
Facility ID: DP.I51.00074 Facility Type: Surface Detention
Date/Time: 5/12/2021
Owner: City of Bozeman Contact: Tom Radcliffe, tradcliffe@bozeman.net
Inspector’s Name, contact info: Adam Oliver, aoliver@bozeman.net
Location/Access info: WRF, outside of fenced area near WRF outfall
Type of Inspection:
☒ Routine, Dry Weather ☐ Routine, Wet Weather ☐ Complaint Driven ☐ Other: __________________
Section 2: Weather and Discharge Information
Most recent precipitation or melt: >48hrs
Temperature: 59°F
Is a stormwater discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Is an illegal discharge occurring? ☐ Yes ☒ No
If yes, what is the source and quality of discharge?
Notes: 2021 High Priority Inspection.
Section 3: Facility Maintenance Priority
☒ Low: Stormwater facility appears to be functioning as designed. Continue scheduled maintenance.
☐ Medium: Stormwater facility requires minor to moderate sediment and vegetation maintenance to mitigate the risk of
flooding, waterway pollution, and infrastructure failure.
☐ High: Stormwater facility requires significant sediment dredging, vegetation removal, and/or infrastructure repairs to
restore function.
Inspector’s Signature: ________________________________ Date: ___________________ 6/8/2021
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 2 2020
Section 4: Qualitative Analysis
Components # Items Conditions Results Notes and Required Actions
General
1.1 Accessibility Degraded, missing, or inadequate
maintenance access?
☐ Yes ☒ No
1.2 Debris Trash, sediment, and waste within
and around the facility?
☐ Yes ☒ No
1.3 Vegetation
Overgrown or dead cattails,
woody shrubs, weeds, grass, and
trees?
☐ Yes ☒ No
1.4 Infrastructure
Condition
Damaged inlet pipe, outlet pipe,
outfall structure, or fencing?
☐ Yes ☒ No
Facility
Condition
2.1 Pretreatment Bay
or Facility
Clogged, obstructed, or filled
pretreatment forebay or facility?
☐ Yes
☒ No
2.2 Storage Bay Clogged or filled storage bay? ☐ Yes
☒ No
2.3 Groundwater or
Standing Water
Stagnant water with a drain
downtime greater than 48 hours
post-rain event?
☐ Yes
☒ No No rain within 48 hours, but no signs of standing water either
2.4 Flow Path Clogged or obstructed flow path? ☐ Yes ☒ No
2.5 Side Slopes Barren or exposed surfaces on
Facility’s side slopes and bottom?
☐ Yes ☒ No
Maintenance
3.1 Maintenance Plan
or Agreement Is there a written plan? ☒ Yes ☐ No
3.2 Implementation Is there evidence of maintenance? ☒ Yes ☐ No
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 3 2020
Section 5: Quantitative Analysis
Vegetation
Cover type % Within
facility Notes
Bare ground 0
Aquatics 0
Grasses/Herbaceous 100
Trees >3” DBH 0
Shrubs
0
Total
100
Elevation
Analysis
Location Reading (ft) Elevation (ft) Notes
SRV#CP
Control Point 3.82 4605.82 MH lid. H.I. = 4605.82
SRV#1
Inlet - -
SRV#2
Outlet 6.51 4599.31 PVC invert out of basin to outlet structure
SRV#3
Center 6.78 4599.04
SRV#4
North of Center - -
SRV#5
East of Center 6.56 4599.26
SRV#6
South of Center - -
SRV#7
West of center 6.78 4599.04
SRV#8
Berm or overflow 4.42 4601.4
SRV#9 - -
Summary
This facility is in good condition. There were no apparent changes, so I did not take elevations. I will repeat that task in 2022.
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 4 2020
Section 6: Facility Sketch
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 5 2020
Section 7: Photo Log
Image 1
Facility overview, evidence of mowing since last inspection. (west view)
Image 2
Outfall. (north view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913
Stormwater Facility Inspection Form Page 6 2020
Image 3
PVC outlet from basin to outlet structure. There is no evidence of recent
flow. (north view)
Image 4
Outlet structure and basin. (south view)
DocuSign Envelope ID: 5EB6CD9B-9275-4C9C-BBB3-D27F70A49913