HomeMy WebLinkAbout005 Lighting Plan Sheet ES2. ELECTRICAL LEGEND (NOT ALL SYMBOLS ARE USED ON THIS PROJECT) .,•° scoff r. =+�i II�II-(�^/, PEDESTAL COMPONENT LIST �S,]0TdFQ0,3 IJ '�_\ O 200A. ER REQUIREMENTS. NEMA 3R. METER HOUSING CONFORMING TO UTILITY /� LIGHT POLE WITH BASE DUPLEX RECEPTACLE �� BRANCH CIRCUIT CONCEALED IN WALL OR A PROVIDER REQUIREMENTS. �+ N CEILING ENS„ 3 HORIZONTALLY MOUNTED DUPLEX RECEPTACLE BRANCH CIRCUIT CONCEALED IN OR O 200A, 250V, HEAVY DUTY, 2-POLE, NEMA 3R, FUSED SERVICE /bNA� UNDER FLOOR ENTRANCE RATED DISCONNECT SWITCH WITH GROUND AND NEUTRAL 0 30A DRYER RECEPTACLE -� EMPTY CONDUIT- 3/4"UNLESS NOTED BARS. 1'X4' SURFACE MOUNT LIGHT FIXTURE 50A RANGE RECEPTACLE y OTHERWISE A l HOME RUN TO PANEL. NUMBER OF ARROWS © 200A, MEG, 120/24OV-1B-3W, 12-SPACE, NEMA 3R LOAD CENTER 4' INDUSTRIAL STRIP LIGHT FIXTURE QUADRAPLEX RECEPTACLE INDICATES NUMBER OF CIRCUITS. WITH BRANCH BREAKERS AS LISTED ON THE PANEL SCHEDULE. NUMBER OF HASHMARKS INDICATES NUMBER HEAVY DUTY, GALVANIZED C-CHANNEL TYPE RACKING SET IN SUSPENDED LINEAR LIGHT FIXTURE ® CEILING MOUNTED RECEPTACLE OF CONDUCTORS, NO HASHMARKS INDICATES O CONCRETE. PAINT TO MATCH PANEL COLOR. TWO CONDUCTORS. HASHMARKS NOT SHOWN Q OR GROUND WIRES Z crl INDICATES GROUND FAULT INTERRUPTER DEVICE O 30-AMP 12-POLE ELECTRICALLY HELD LIGHTING CONTRACTOR z WALL MOUNT LIGHT FIXTURE FURNISHED WITH 120-VOLT COIL. N ®PAD FLOOR RECEPTACLE- COMBINATION POWER/DATA W O RECESSED DOWNUGHT O G O 8'-0"COPPER-CLAD DRIVEN GROUND ROD WITH APPROVED GROUND POWER DIRECT CONNECTION ROD CLAMP. CEILING MOUNTED EXIT SIGN,ARROWS O POWER MOTOR CONNECTION NEMA 3R 120V PHOTO ELECTRIC CONTROL WITH TWIST-LOCK SHOWN SHALL BE PROVIDED ON EXIT SIGN INSTALLED U ELECTRICAL PANEL- 208Y/120V 3 PHASE 4 WIRE RECEPTACLE BASE ATTACHED TO 3-WAY SWITCH (HOA). NOTE: ELECTRICAL CONTRACTOR SHALL SINGLE POLE TOGGLE SWITCH E]Oj JUNCTION BOX - MINIMUM OF 4"SQUARE COORDINATE ALL UTILITY REQUIREMENTS, FRONT ELEVATION NOTE: UNDERGROUND COMBINATION METER/SERVICE PANEL ASSEMBLY ELECTRICAL BOX FINAL LOCATIONS AND LOAD PROVIDE METER/MAIN AND ALL MAY BE USED IF APPROVED BY ENGINEER. INFORMATION WITH UTILITY COMPANY. NECESSARY EQUIPMENT PER THE W A ELECTRIC UTILITY'S REQUIREMENTS IT F ABBREVIATIONS AC ABOVE COUNTER (E) EXISTING TO REMAIN LTS LIGHTS (R) REMOVE AND RELOCATE ETERLU ADA AMERICANS W/DISABILITIES EF EXHAUST FAN MECH MECHANICAL RCPT RECEPTACLE(S) REAR ELEVATION ACT COMPLIANT EQUIPMENT ELECT ELECTRICAL MC, M.C. MECHANICAL CONTRACTOR SCH SCHEDULE AD ACCESS DOOR EPO EMERGENCY POWER OFF MOB MAIN DISTRIBUTION BOARD SF SQUARE FOOT E Zz0¢ ALL ABOVE FINISHED FLOOR EWC ELECTRIC WATER COOLER MDP MAIN DISTRIBUTION PANEL TC TEMPERATURE CONTROLS CONTRACTOR mroao AHU AIR HANDLING UNIT FCO FLOOR CLEANOUT MFR MANUFACTURER TGB TELECOMMUNICATIONS GROUND BAR PANEL zoo BKR, CB CIRCUIT BREAKER FCU FAN COIL UNIT MLO MAIN LUGS ONLY TTB TELECOMMUNICATIONS TERMINAL BOARD .�OZ CLNG CEILING FD FLOOR DRAIN (N) NEW TYP TYPICAL B �� _ CONT CONTINUATION FD FIRE DAMPER NEC NATIONAL ELECTRICAL CODE UH UNIT HEATER O CDC DIRECT DIGITAL CONTROL FD/SD FIRE/SMOKE DAMPER NL NIGHT LIGHT UNO UNLESS NOTED OTHERWISE DF DRINKING FOUNTAIN FE FIRE EXTINGUISHER NO NUMBER W WALL-MOUNTED DEVICE $m DISC DISCONNECT SWITCH GF FLOOR SINK OD, O.D. OUTSIDE DIAMETER WG WIRE GUARD E.C., EC ELECTRICAL CONTRACTOR GFCI, GFI GROUND FAULT CIRCUIT INTERRUPTER 96 PB PULL BOX WP WE 60" y GNU GROUND PMR PER MFR'S RECOMMENDATIONS WR WEATHER-RESISTANT NO H.O. HIGH OUTPUT POS POINT OF SALE (CASH REGISTER) WEXISTING TO BE REMOVED L \ IG INSULATED GROUND EXISTING i ELECTRIC UTILITYTRANSFORMER LEXISTINGLIGHT FIXTURE SCHEDULE ELECTRIC unuTYTRANSFORMERTYPE (XX) CATALOG NUMBER: LAMP: MOUNTING: BALLAST/DRIVER: VOLT: WATT: DESCRIPTION:TYPE (Ci) LUMEC-FIXTURE: RFS-54W16LED3K-G2-R2M-UNV-DMG-FAWS- LED 30FT POLE LED DRIVER 120 53 6,000 LUMEN LED LIGHT FIXTURE WITH A TYPE 2 MEDIUM ABOVE GROUND �WPH9-RCD7-SP2-BK LED 6FT MASTARM <20%THD - ROADWAY DISTRIBUTION. PROVIDE A ROUND TAPERED ------- ---- — _ �T' --------- —————— W F O POLE: PER DETAIL#3/ES2.1. 277 GALVANIZED POLE POWDER COATED BLACK AND MEETING UNDER GROUND BASE PER DETAIL#4/ES2.1. SHORTTHE ING CAPS ON BASE POLE DETAILS TWIST-LOCK RE^CEPTAC ESO ON \�\�\� \/ i\/ \\��\��\ N ; LIGHT FIXTURES. PROVIDE BREAKAWAY BOLT COUPLING(S) xj�\/ \ \\� /�\\/� ON ANCHOR BOLTS, BREAKAWAY BOLT SKIRT TO BE /�� /i �� /�� DRAWN BY: STE BLACK AND INSTALL SEAMLESSLY WITH LIGHT POLE 36„ \� \��\f� DESIGNED P.V: STE FLANGE AND COVER. /� �\ \//i /i \\j QUALITY CHECK: STE �\ DATE: 1112020 TYPE (Li) LUMEC-FIXTURE: RFS-35W16LED3K-G2-R2M-UNV-DMG-FAWS- LED 30FT POLE LED DRIVER 120 40 4,500 LUMEN LED LIGHT FIXTURE WITH A TYPE 2 MEDIUM \j JOB NIO. B16-089 PH9-RCD7-SP2-BR 3000K 6FT MASTARM <20%TIED - ROADWAY DISTRIBUTION. PROVIDE A ROUND TAPERED F POLE PER DETAIL#3/ES2.1. 277 GALVANIZED POE POWDER COATED BRONZE AND MEETING 8' (MIN) %�i j� / ��� �'/ /�/ 8' (MIN) FIELDEOOK BASE PER DETAIL#4/ES2.1. SHORTIINGT POLE CAPS ON BASE DETAILS TWIST-OCCKI RECEPTACLES ESO ON LIGHT FIXTURES. #6 CU. GIRD TO (2)GROUND RODS #6 CU. GRD TO (2) GROUND RODS PER THE LATEST EDITION NEC AND ALL PER THE LATEST EDITION NEC AND ALI PROVIDE CONDUIT PER APPLICABLE CODES. PROVIDE CONDUIT PER APPLICABLE CODES. ELECTRIC UTILITIES REQUIREMENTS ELECTRIC UTILITIES REQUIREMENTS 1�SITE LIGHTING ELECTRICAL DETAIL NO.8 CRIMPED HIGH CARBON STEEL NO SCALE �W PULL BOX-COMPOSITE WIRE SPACED AS SHOWN. 6 ONE 6'-0"MASTARM MINIMUM DIMENSIONS WAY, s THE OTHER war. TYPE 1 TYPE 2 TYPE 3 + + — W W = 13" W = ifi" W = 19'• ++ SINGLE MEMBER TYPE D = 17 D = 12^ D = 12" ++ MASTARM (TYPICAL) W IDL = I 11' L 2 2 1 I 11 I D 0' DW DW 8" a CL = 18' CL = 23" CL = K CL 2 BEVEL —j C W = 11' C W = 13" C W = 17" Q Q PROVIDE PULL BOXES CONSTRUCTED OF CLASS GENERAL CONCRETE, OR L�1 NOTE: WHEN REPLACING AN EXISTING W ��E UALL USE GRADE 60 REINFORCING STEEL 0 PULL BOX,ADJUST CONDUIT �2. ?; 2.. .J*up # 6 BARS (4'-1'• LONG) O STUB HEIGHT ACCORDINGLY. II-"'1I r 2. .. _ (8 TYPICAL)JREINIORCED # 4 HOOPS AT 1. IDL :.130'-0' ° 1'-0"CENTERS W CAGE f .)I ANCHOR ANCHOR BOLT ANCHOR BOLT CIRCLE 0ELECTRICAL BOND. NO.6 AWG (4 TYPICAL) °-... O Q COPPER OR EQUAL IF METAL O. 16 GALVANIZED j :j - CONDUIT MESH 2-1/2" CLEARANCE aI �1.• �] I`1 SECTION A-A LV ^ ELECTRICAL BOND. NO.6 AWG GROUNDING LUG a N rrl STUB CONDUIT 4"TO 6" F+i ABOVE BOTTOM OF PULL BOX COPPER OR EQUAL IF METAL �12" 3.� CONDUIT ONO. 6 AWG BARE R PIGTAIL EXTENSION GROUND WIRE NOTTRUDE MORE THAN CONDUIT•FROM FOUNDATION W m 2,. Y Yx" Q 4"x 6"REINFORCED J 12" - - HAND HOLE&COVER COPPER GROUNDING STR P BETWE N CONCRETE PAD O STUB CONDUIT 4^TO 6" ANCHOR BOLT, CONDUIT IF MEAL & 2'-0" _ ABOVE BOTTOM OF PULL BOX PIGTAIL AEXTENSIE GROUND WIRE OR A ° - A ,^ 23" vI O CP CONDUIT IN PLACE 0 CONDUIT IN PLACE 1'� 5' MIN. 8 Q U AS REQUIRED AS REQUIRED L 6'-6" ° W � BREAKAWAY BOLT ° CLASS GENERALCONCRETE F�1 (P 1"CLEAN STONE (P 1"CLEAN STONE 6" COUPLINGS ° FOUNDATION O p DRAINAGE NO HIGHER O p DRAINAGE NO HIGHER EIGHT#4 HOOPS U It THAN 2"INSIDE THAN 2'INSIDE NOTE- MAKE THE TOP OF THE CONCRETE --"T Frl BOTTOM OF PULL BOX BOTTOM OF PULL BOX FOUNDATION 6"ABOVE THE GROUND LINE L 3• F+�°I PULL BOX INSTALLED IN DIRT PULL BOX INSTALLED IN A SIDEWALK OR ASPHALT PROVIDE A HANDHOLE DETAIL AND A J"NUT TYPICAL OF ALL FOUNDATIONS W HOLDER DETAIL(FOR GROUNDING). 2�PULL BOX DETAIL r3 LIGHT FIXTURE TYPE'C1'&'L1'POLE DETAIL LIGHT FIXTURE TYPE(S)'Cl'&'L1'BASE DETAIL .— $2, NO SCALE $'2, NO SCALE $2, NO SCALE SHEET ES2.1