HomeMy WebLinkAbout004 Lighting Plan Sheet ES1. Scott�T.!' 'ice
1 /
! VC DEVELOPMENT .4C N
-- ---- �� 1184 NORTH 15TH AVE.
----------
------------------------------- -
✓ - ---- -SUfTE 4- --- - -- - - -- - - - - Q'+ b10UNA
W�
!ff ✓�� BOZEMAN, MT 59715
-• -•-- -•---
1 m 0
f o
Ln
L1
U) `T® I --
/ / 0
o
� I j o
>
W
LOT 2 I I E�z�
oa
J I J zuo_
o
J LOT 1
d -- 2
I ..
m
LOT 4 ` — — " N
J —
��' c, c D
U
2 I z W
aw=O
O¢
1 rN
2
o
�pf
DRAWN BY: STE
j LOT 3
SPIRE HOLDINGS, DESIGNED BY: STE
13 ENTERPRISE B QUALITY CHECK: STE
.� • � I BOZEMAN, MT 59, DATE: 1112020
l
JOB NO, B16-089
Cl 2 ' FIELDBOOK
2
1
— — — — — - — — — — — — — —
�'� NORTH 7TH AVENUE 3 W
- ---
-GGLLECTOR w
---- - W
_ ly C7
----
GENERAL NOTES
- -
INSTALL ALL NEW WORK TO MEET CURRENT CODES AND INSTALLATION STANDARDS. µ"
� 1 o
2. WIRING FOR STREET LIGHTS SHALL BE UNDERGROUND AND IN 2" DIAMETER SCHEDULE 80 1
PVC CONDUIT AS NOTED ON THE PLANS. CONDUITS SHALL TYPICALLY BE PLACED 2 FEET ELECTRICAL SITE PLAN W -
FROM THE BACK OF CURB. ALL WIRING SHALL BE INSTALLED TO MEET THE NATIONAL N LL
ELECTRIC CODE. PULL BOXES SHALL BE REINFORCED CONCRETE AND SHALL BE LOCATED SCALE:1"-40'-0" CONSTRUCTION NOTES 0 Q Z
TO NOT IMPEDE ACCESS TO PROPERTIES.
3. COORDINATE THE COMMON USE OF NORTHWESTERN ENERGY TRENCHES WHENEVER 1 PROVIDE A 240/120V 1 PHASE, 3 WIRE ELECTRICAL SERVICE AS DETAILED ON SHEET ES2.1. d N
POSSIBLE. O COORDINATE LOCATION WITH UTILITY PRIOR TO INSTALLATION. THE METER PEDESTAL SHALL W 0 a
HAVE A MINIMUM HEIGHT OF 4'-0" AND A MAXIMUM HEIGHT OF 5'-0" ABOVE FINISHED Y m W
4. THE CIRCUITRY/CONDUIT SHOWN IN A DASHED LINETYPE SHALL BE NORMAL POWER, GRADE PER THE CITY OF BOZEMAN'S SITE LIGHTING REQUIREMENTS. REFER TO THE Q ►�-I
INSTALLED UNDERGROUND PER THE LATEST EDITION OF THE NATION ELECTRIC CODE. ELECTRICAL ONE-LINE DIAGRAM, DETAIL #1/ES2.1. J (/)
CONDUIT SHALL BE INSTALLED WITH A MINIMUM COVER REQUIREMENT OF 18 INCHES
BELOW FINISHED GRADE. PROVIDE A TYPE 1 IN-GROUND ELECTRIC PULL-BOX AS DETAILED ON SHEET ES2.1. THE Cl)
O COVER SHALL BE LABELED 'ELECTRIC' AND IT SHALL INCLUDE TAMPER-RESISTANT PENTAGON Q
5. COORDINATE FINAL LOCATIONS OF THE METER PEDESTAL, LIGHT POLES, AND JUNCTION W
BOXES WITH FINAL ROAD AND SIDEWALKS. BOLTS. PROVIDE PULLBOX ADJACENT TO THE LIGHT POLE AND ROUTE 2" CONDUITS DIRECTLY
TO THE PULL-BOX. PROVIDE THE 1 1/2" CONDUIT AND #10 CONDUCTORS FROM THE
6. PROVIDE LIGHT POLE BASES PER LIGHT POLE MANUFACTURERS REQUIREMENTS AND PULLBOX TO THE LIGHT POLE PER THE LIGHT POLE BASE DETAIL(S).
DETAILS.
7. LIGHT POLE BASES ARE TO BE INSTALLED ADJACENT TO THE SIDEWALK, NO CLOSER THAN PROVIDE CONDUIT THROUGH THE SLEEVES PROVIDED BY OTHERS.O 0 5'-0" FROM THE ROAD. 3
8. PROVIDE FUSING WITHIN EACH LIGHT POLE HANDHOLE PER DETAIL #2/ES2.2. LIGHT POLES TO BE PROVIDED BY DEVELOPMENT AND FED FROM HOUSE SERVICE. SS
O ENGI�RING