HomeMy WebLinkAbout001_COVERCONCRETE
COMPACTED GRAVEL
EARTH
BRICK
C.M.U.
STEEL
FINISH WOOD
BATT INSUL.
RIGID INSUL.
GYP. BD.
DETAIL REFERENCE1
A1.0
SECTION CUT 1
A3.0
INTERIOR ELEVATION 1
A4.0
ROOM NUMBER
100
ROOM
DOOR NUMBER 100
WINDOW TYPE A
NOTE REFERENCE 1
WALL TYPE A
CITY LIMITS
PROJECT SITE
M-1
PLI
VICINITY MAP
PROJECT SITE
COPYRIGHT 2007
COVER
SHEET OWNER:SITE PLAN REVIEW
12/03/21
2008STELLA FRIABRONKEN WAREHOUSE3345 Prince Lane, Bozeman, MTBRONKEN WAREHOUSE
3345 Prince Lane,
Bozeman, MT
ARCHITECTURAL
NO.DRAWING SHEET
SCHEDULE OF DRAWINGS:
ELECTRICAL
NO.DRAWING SHEET
E0.4
E0.5
E0.6
E0.7
E5.0
SITE ELECTRICAL PLAN
PHOTOMETRIC SITE PLAN
SITE PLAN CUT SHEETS
SITE PLAN CUT SHEETS
ELECTRICAL DETAILS
LANDSCAPE
NO.DRAWING SHEET
L1.0
L1.1
LANDSCAPE PLAN
LANDSCAPE DETAILS
CIVIL
NO.DRAWING SHEET
C0.10
C0.15
C0.20
C0.30
C0.40
C0.50
C0.60
C1.0
C2.0
C3.0
C5.0
C5.1
GENERAL NOTES
CONSTRUCTION ROUTE MAP
EROSION AND SEDIMENT CONTROL DETAILS
WATER DETAILS
SANITARY AND STORM SEWER DETAILS
CURB, PAVING AND APPROACH DETAILS
EXISTING SITE FEATURES AND TOPOGRAPHY
OVERALL SITE PLAN
EROSION AND SEDIMENT CONTROL PLAN
UTILITY PLAN
GRADING AND DRAINAGE PLAN NORTH
GRADING AND DRAINAGE PLAN SOUTH
PROJECT TEAM
CIVIL
2880 TECHNOLOGY BLVD
BOZEMAN, MONTANA 59718
MORRISON-MAIERLE, INC.
STRUCTURAL
1060 S FOWLER AVE SUITE 202
BOZEMAN, MONTANA 59718
DCI ENGINEERS
MECHANICAL / ELECTRICAL / PLUMBING
12 N BROADWAY
BELGRADE, MONTANA 59714
ASSOCIATED CONSTRUCTION ENGINEERING, INC.
SITE DEVELOPMENT
NO.DRAWING SHEET
GENERAL NOTES
ALL WORK INCLUDED IN THIS CONTRACT, SHALL COMPLY WITH THE LATEST EDITION OF
INTERNATIONAL BUILDING CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL
MECHANICAL CODE, ICC ELECTRICAL CODE, AND ALL OTHER LAWS, CODES, OF LOCAL,
COUNTY, STATE, AND LOCAL JURISDICTION INVOLVED.
THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO STARTING THE WORK. THE
CONTRACTOR SHALL VERIFY GRADES, SITE CONDITIONS, AND COMPARE THAT WITH THE
DIMENSIONS SHOWN ON THE DRAWINGS. WHERE CONFLICT EXISTS, THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT UPON RECOGNITION OF ANY DISCREPANCY.
THE CONTRACTOR SHALL CAREFULLY STUDY ALL PLANS AND DRAWINGS, AND SHALL
REPORT IMMEDIATELY TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS
THEY MAY DISCOVER. THE CONTRACTOR SHALL NOT WORK WITHOUT DRAWINGS. THE
CONTRACTOR SHALL CONSULT THE ARCHITECT OR SUBMIT SHOP DRAWINGS AND/OR
LITERATURE TO THE ARCHITECT FOR APPROVAL PRIOR TO STARTING THE WORK.
THE GENERAL CONTRACTOR SHALL GIVE ALL NOTICES AND SHALL COMPLY WITH ALL LAWS,
ORDINANCES, RULES, REGULATIONS, AND ORDERS OF PUBLIC AUTHORITY BEARING ON THE
PERFORMANCE OF THE WORK. IF THE CONTRACTOR OBSERVES THAT ANY OF THE
CONTRACT DOCUMENTS ARE AT VARIANCE THEREWITH IN ANY RESPECT THEY SHALL
PROMPTLY NOTIFY THE ARCHITECT OF ANY CHANGES REQUIRING ADJUSTMENT WITH
APPROPRIATE MODIFICATION.
ONLY APPROVED 'CONSTRUCTION SET' MARKED DRAWINGS INCORPORATING ALL
ADDENDUM AND DIMENSION CLARIFICATIONS SHALL BE USED DURING THE EXECUTION OF
THE WORK.
THE CONTRACTOR SHALL USE WRITTEN DIMENSIONS ONLY, OR AS DIRECTED BY
ARCHITECT. THE CONTRACTOR SHALL NOT SCALE DRAWINGS.
CROSS REFERENCES SHOWN ON DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE
CONDITIONS AND DO NOT LIMIT APPLICATION OF ANY DRAWING OR DETAIL. THEY MAY
APPLY TO OTHER, SAME, OR SIMILAR CONDITIONS NOT REFERENCED.
INTERIOR WALL DIMENSIONS (FOR NEW WALLS ONLY) ARE TO FACE OF STUD FRAMING
UNLESS OTHERWISE NOTED.
SECTION AND INTERIOR ELEVATION DIMENSIONS ARE TO THE TOP OF CONCRETE OR METAL
DECKING UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION OF
SUBCONTRACTORS WORK TO SECURE COMPLIANCE OF DRAWINGS AND SPECIFICATIONS,
THE ACCURATE LOCATION OF STRUCTURE MEMBERS, AND OPENINGS FOR MECHANICAL,
ELECTRICAL, STAIRS, ELEVATORS, AND MISCELLANEOUS EQUIPMENT.
CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL
AND ELECTRICAL EQUIPMENT WITH RESPECTIVE SUB-CONTRACTORS, AS WELL AS SHOP
DRAWINGS REVIEWED BY THE ARCHITECT.
CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT AND PROVIDE
ALL BUCK-OUT BLOCKING AND BACKING REQUIRED BY THIS CONTRACT AND OTHERS.
WHERE PIPING, CONDUIT, AND/OR DUCTS PASS THROUGH FIRE RATED WALLS, PACK
AROUND OPENINGS WITH SAVING OR SPRAY INSULATION. PROVIDE FIRE DAMPERS WHERE
NECESSARY.
THE PROPOSED BUILDING AND SITE PLAN MAKE ALL NECESSARY ACCOMMODATIONS TO
MEET ALL LOCAL AND STATE ACCESSIBILITY REQUIREMENTS.
ABBREVIATIONS NOTES AND SYMBOLS
ALUM.ALUMINUM MECH.MECHANICAL
ANN.ANNUNCIATOR MFG.MANUFACTURER
M.R.MOISTURE RESISTANT
BD.BOARD MTL.METAL
BLCK'G.BLOCKING
N.I.C.NOT IN CONTRACT
CAB.CABINET
CER.CERAMIC O.C.ON CENTER
CLR.CLEARANCE O.S.B.ORIENTED STRAND
BOARD
COMP.COMPOSITE O.F.C.I.OWNER FURNISHED
CONC.CONCRETE CONTRACTOR
INSTALLED
CONF.CONFERENCE O.F.O.I.OWNER FURNISHED
CORR.CORRIDOR OWNER INSTALLED
C.M.U.CONCRETE MASONRY UNIT
C.T.CERAMIC TILE P.PAINT
CUST.CUSTOM P. LAM.PLASTIC LAMINATE
P.T.PAPER TOWEL
D.F.DRINKING FOUNTAIN PRE-FIN.PRE-FINISHED
DISP.DISPENSER PVC.POLYVINYLCHLORIDE
D.M.DRYMARK BOARD
DR.DRAWER R.RADIUS
REC.RECESSED
E.I.F.S.EXTERIOR INSULATION REST.RESTROOM
FINISH SYSTEM REQ'D.REQUIRED
E.P.S.EXTRUDED POLYSTYRENE
ELEV.ELEVATION S.STAIN
S.C.SOLID CORE
F.D.FLOOR DRAIN S.F.SQUARE FEET
F.E.FIRE EXTINGUISHER S.V.SHEET VINYL
F.F.FINISH FLOOR SIM.SIMILAR
F.S.FLOOR SINK SPECS.SPECIFICATIONS
FLR.FLOORING STOR.STORAGE
FDN.FOUNDATION
F.O.FACE OF T.B.TACK BOARD
T.O.TOP OF
G.B.GYPSUM WALLBOARD T.P.TOILET PAPER
GWB GYPSUM WALLBOARD TYP.TYPICAL
GYP. BD.GYPSUM WALLBOARD V.B.VAPOR BARRIER
V.C.T.VINYL COMPOSITION
TILE
HC.HANDICAPPED VER.VERIFY
H.M.HOLLOW METAL
W/WITH
INSUL.INSULATION W/O WITHOUT
JAN.JANITOR
MATERIALS LEGEND
A0.1
A1.0
A1.1a
A1.1b
A1.2
A1.3
A1.4
A1.6
A2.0
A2.1
A2.2
A2.3
A2.4
A2.5
A2.6
A2.7
CODE PLANS
FIRST FLOOR PLAN -OVERALL
FIRST FLOOR PLAN -NORTH
FIRST FLOOR PLAN -SOUTH
FIRST FLOOR PLAN -OFFICE
ENLARGED FLOOR PLANS
SECOND FLOOR PLAN -OVERALL
ROOF PLAN -OVERALL
EXTERIOR ELEVATIONS -OVERALL
ENLARGED ELEVATIONS -NORTH
ENLARGED ELEVATIONS -SOUTH
ENLARGED ELEVATIONS -EAST
ENLARGED ELEVATIONS -WEST
3D VIEWS
EXTERIOR MATERIAL PALLET
EXTERIOR ELEVATIONS
OWNER
701 GOLD AVE
BOZEMAN, MONTANA 59715
STELLA FRIA
OWNER'S REP
48 W CLARA CT
BOZEMAN, MONTANA 59718
TATE MANAGEMENT
ARCHITECTURAL
101 E. MAIN STUDIO
BOZEMAN, MONTANA 59715
THINKONE
SITE SUMMARY
ZONING DISTRICT: M-1
COMMUNITY PLAN FUTURE USE: INDUSTRIAL
LEGAL DESCRIPTION: Lots 5 and 6 of the Nelson Meadows
Subdivision, Situated in the SE 1/4 Section 22 and the NE 1/4 Section
27, Township 1 South, Range 5 East, Principal Meridian, City of
Bozeman, Gallatin County, Montana (See Site Plan for metes and
bounds)
PARCEL SIZE: 5.15 Acres (224,334 SF)
PROPOSED BUILDING AREA: 68,264 SF
LOT COVERAGE: 30% (224,334/68,264 = .30) 100% ALLOWED PER
TABLE 38.320.050
PARKING / CIRCULATION: 42,415 SF
LANDSCAPE COVERAGE: SOD -25,128 SF
NATIVE DRASS SEED -68,153 SF
ROCK MULCH -8,723 SF
TOTAL -102,004 SF
SOUTHWEST PERSPECTIVE
SD1.0
SD1.1
SD1.2
SITE PLAN -EXISTING
SITE PLAN
SITE PLAN DETAILS
PARKING CALCULATIONS:
1
WAREHOUSE FACILITY 1 space per 1,000 SF of floor area
devoted to storage of goods
1 space per 350 SF of floor area for
spaces to support accessory office or
retail sales facilities.
OFFICE 5341 SF OFFICE SPACE (.85) /
350 SF = 12.9 (13) STALLS
TOTAL: 33 STALLS
15645 SF/1,000 SF=
15.6 (16) STALLS DELIVERY TRUCK (12 x 45) = 12
OVERSIZE STALLS (10 x 20 ) = 21
CODE REQUIREMENT STALLS REQUIRED STALLS PROVIDED
TOTAL: 15 STALLS
STANDARD SIZED STALLS (9 x 18) = 15
TOTAL FOR ENTIRE SITE: 48 STALLS
NOTE: ALTERNATIVE PARKING
CALCULATION USED FOR WAREHOUSE
PARKING, SEE ATTACHED NARRATIVE
CONSTRUCTION MANAGEMENT
NO.DRAWING SHEET
CM1.0 CONSTRUCTION MANAGEMENT PLAN