Loading...
HomeMy WebLinkAbout001_COVERCONCRETE COMPACTED GRAVEL EARTH BRICK C.M.U. STEEL FINISH WOOD BATT INSUL. RIGID INSUL. GYP. BD. DETAIL REFERENCE1 A1.0 SECTION CUT 1 A3.0 INTERIOR ELEVATION 1 A4.0 ROOM NUMBER 100 ROOM DOOR NUMBER 100 WINDOW TYPE A NOTE REFERENCE 1 WALL TYPE A CITY LIMITS PROJECT SITE M-1 PLI VICINITY MAP PROJECT SITE COPYRIGHT 2007 COVER SHEET OWNER:SITE PLAN REVIEW 12/03/21 2008STELLA FRIABRONKEN WAREHOUSE3345 Prince Lane, Bozeman, MTBRONKEN WAREHOUSE 3345 Prince Lane, Bozeman, MT ARCHITECTURAL NO.DRAWING SHEET SCHEDULE OF DRAWINGS: ELECTRICAL NO.DRAWING SHEET E0.4 E0.5 E0.6 E0.7 E5.0 SITE ELECTRICAL PLAN PHOTOMETRIC SITE PLAN SITE PLAN CUT SHEETS SITE PLAN CUT SHEETS ELECTRICAL DETAILS LANDSCAPE NO.DRAWING SHEET L1.0 L1.1 LANDSCAPE PLAN LANDSCAPE DETAILS CIVIL NO.DRAWING SHEET C0.10 C0.15 C0.20 C0.30 C0.40 C0.50 C0.60 C1.0 C2.0 C3.0 C5.0 C5.1 GENERAL NOTES CONSTRUCTION ROUTE MAP EROSION AND SEDIMENT CONTROL DETAILS WATER DETAILS SANITARY AND STORM SEWER DETAILS CURB, PAVING AND APPROACH DETAILS EXISTING SITE FEATURES AND TOPOGRAPHY OVERALL SITE PLAN EROSION AND SEDIMENT CONTROL PLAN UTILITY PLAN GRADING AND DRAINAGE PLAN NORTH GRADING AND DRAINAGE PLAN SOUTH PROJECT TEAM CIVIL 2880 TECHNOLOGY BLVD BOZEMAN, MONTANA 59718 MORRISON-MAIERLE, INC. STRUCTURAL 1060 S FOWLER AVE SUITE 202 BOZEMAN, MONTANA 59718 DCI ENGINEERS MECHANICAL / ELECTRICAL / PLUMBING 12 N BROADWAY BELGRADE, MONTANA 59714 ASSOCIATED CONSTRUCTION ENGINEERING, INC. SITE DEVELOPMENT NO.DRAWING SHEET GENERAL NOTES ALL WORK INCLUDED IN THIS CONTRACT, SHALL COMPLY WITH THE LATEST EDITION OF INTERNATIONAL BUILDING CODE, INTERNATIONAL PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, ICC ELECTRICAL CODE, AND ALL OTHER LAWS, CODES, OF LOCAL, COUNTY, STATE, AND LOCAL JURISDICTION INVOLVED. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO STARTING THE WORK. THE CONTRACTOR SHALL VERIFY GRADES, SITE CONDITIONS, AND COMPARE THAT WITH THE DIMENSIONS SHOWN ON THE DRAWINGS. WHERE CONFLICT EXISTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT UPON RECOGNITION OF ANY DISCREPANCY. THE CONTRACTOR SHALL CAREFULLY STUDY ALL PLANS AND DRAWINGS, AND SHALL REPORT IMMEDIATELY TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS THEY MAY DISCOVER. THE CONTRACTOR SHALL NOT WORK WITHOUT DRAWINGS. THE CONTRACTOR SHALL CONSULT THE ARCHITECT OR SUBMIT SHOP DRAWINGS AND/OR LITERATURE TO THE ARCHITECT FOR APPROVAL PRIOR TO STARTING THE WORK. THE GENERAL CONTRACTOR SHALL GIVE ALL NOTICES AND SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND ORDERS OF PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. IF THE CONTRACTOR OBSERVES THAT ANY OF THE CONTRACT DOCUMENTS ARE AT VARIANCE THEREWITH IN ANY RESPECT THEY SHALL PROMPTLY NOTIFY THE ARCHITECT OF ANY CHANGES REQUIRING ADJUSTMENT WITH APPROPRIATE MODIFICATION. ONLY APPROVED 'CONSTRUCTION SET' MARKED DRAWINGS INCORPORATING ALL ADDENDUM AND DIMENSION CLARIFICATIONS SHALL BE USED DURING THE EXECUTION OF THE WORK. THE CONTRACTOR SHALL USE WRITTEN DIMENSIONS ONLY, OR AS DIRECTED BY ARCHITECT. THE CONTRACTOR SHALL NOT SCALE DRAWINGS. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT LIMIT APPLICATION OF ANY DRAWING OR DETAIL. THEY MAY APPLY TO OTHER, SAME, OR SIMILAR CONDITIONS NOT REFERENCED. INTERIOR WALL DIMENSIONS (FOR NEW WALLS ONLY) ARE TO FACE OF STUD FRAMING UNLESS OTHERWISE NOTED. SECTION AND INTERIOR ELEVATION DIMENSIONS ARE TO THE TOP OF CONCRETE OR METAL DECKING UNLESS OTHERWISE NOTED. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION OF SUBCONTRACTORS WORK TO SECURE COMPLIANCE OF DRAWINGS AND SPECIFICATIONS, THE ACCURATE LOCATION OF STRUCTURE MEMBERS, AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, ELEVATORS, AND MISCELLANEOUS EQUIPMENT. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL AND ELECTRICAL EQUIPMENT WITH RESPECTIVE SUB-CONTRACTORS, AS WELL AS SHOP DRAWINGS REVIEWED BY THE ARCHITECT. CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT AND PROVIDE ALL BUCK-OUT BLOCKING AND BACKING REQUIRED BY THIS CONTRACT AND OTHERS. WHERE PIPING, CONDUIT, AND/OR DUCTS PASS THROUGH FIRE RATED WALLS, PACK AROUND OPENINGS WITH SAVING OR SPRAY INSULATION. PROVIDE FIRE DAMPERS WHERE NECESSARY. THE PROPOSED BUILDING AND SITE PLAN MAKE ALL NECESSARY ACCOMMODATIONS TO MEET ALL LOCAL AND STATE ACCESSIBILITY REQUIREMENTS. ABBREVIATIONS NOTES AND SYMBOLS ALUM.ALUMINUM MECH.MECHANICAL ANN.ANNUNCIATOR MFG.MANUFACTURER M.R.MOISTURE RESISTANT BD.BOARD MTL.METAL BLCK'G.BLOCKING N.I.C.NOT IN CONTRACT CAB.CABINET CER.CERAMIC O.C.ON CENTER CLR.CLEARANCE O.S.B.ORIENTED STRAND BOARD COMP.COMPOSITE O.F.C.I.OWNER FURNISHED CONC.CONCRETE CONTRACTOR INSTALLED CONF.CONFERENCE O.F.O.I.OWNER FURNISHED CORR.CORRIDOR OWNER INSTALLED C.M.U.CONCRETE MASONRY UNIT C.T.CERAMIC TILE P.PAINT CUST.CUSTOM P. LAM.PLASTIC LAMINATE P.T.PAPER TOWEL D.F.DRINKING FOUNTAIN PRE-FIN.PRE-FINISHED DISP.DISPENSER PVC.POLYVINYLCHLORIDE D.M.DRYMARK BOARD DR.DRAWER R.RADIUS REC.RECESSED E.I.F.S.EXTERIOR INSULATION REST.RESTROOM FINISH SYSTEM REQ'D.REQUIRED E.P.S.EXTRUDED POLYSTYRENE ELEV.ELEVATION S.STAIN S.C.SOLID CORE F.D.FLOOR DRAIN S.F.SQUARE FEET F.E.FIRE EXTINGUISHER S.V.SHEET VINYL F.F.FINISH FLOOR SIM.SIMILAR F.S.FLOOR SINK SPECS.SPECIFICATIONS FLR.FLOORING STOR.STORAGE FDN.FOUNDATION F.O.FACE OF T.B.TACK BOARD T.O.TOP OF G.B.GYPSUM WALLBOARD T.P.TOILET PAPER GWB GYPSUM WALLBOARD TYP.TYPICAL GYP. BD.GYPSUM WALLBOARD V.B.VAPOR BARRIER V.C.T.VINYL COMPOSITION TILE HC.HANDICAPPED VER.VERIFY H.M.HOLLOW METAL W/WITH INSUL.INSULATION W/O WITHOUT JAN.JANITOR MATERIALS LEGEND A0.1 A1.0 A1.1a A1.1b A1.2 A1.3 A1.4 A1.6 A2.0 A2.1 A2.2 A2.3 A2.4 A2.5 A2.6 A2.7 CODE PLANS FIRST FLOOR PLAN -OVERALL FIRST FLOOR PLAN -NORTH FIRST FLOOR PLAN -SOUTH FIRST FLOOR PLAN -OFFICE ENLARGED FLOOR PLANS SECOND FLOOR PLAN -OVERALL ROOF PLAN -OVERALL EXTERIOR ELEVATIONS -OVERALL ENLARGED ELEVATIONS -NORTH ENLARGED ELEVATIONS -SOUTH ENLARGED ELEVATIONS -EAST ENLARGED ELEVATIONS -WEST 3D VIEWS EXTERIOR MATERIAL PALLET EXTERIOR ELEVATIONS OWNER 701 GOLD AVE BOZEMAN, MONTANA 59715 STELLA FRIA OWNER'S REP 48 W CLARA CT BOZEMAN, MONTANA 59718 TATE MANAGEMENT ARCHITECTURAL 101 E. MAIN STUDIO BOZEMAN, MONTANA 59715 THINKONE SITE SUMMARY ZONING DISTRICT: M-1 COMMUNITY PLAN FUTURE USE: INDUSTRIAL LEGAL DESCRIPTION: Lots 5 and 6 of the Nelson Meadows Subdivision, Situated in the SE 1/4 Section 22 and the NE 1/4 Section 27, Township 1 South, Range 5 East, Principal Meridian, City of Bozeman, Gallatin County, Montana (See Site Plan for metes and bounds) PARCEL SIZE: 5.15 Acres (224,334 SF) PROPOSED BUILDING AREA: 68,264 SF LOT COVERAGE: 30% (224,334/68,264 = .30) 100% ALLOWED PER TABLE 38.320.050 PARKING / CIRCULATION: 42,415 SF LANDSCAPE COVERAGE: SOD -25,128 SF NATIVE DRASS SEED -68,153 SF ROCK MULCH -8,723 SF TOTAL -102,004 SF SOUTHWEST PERSPECTIVE SD1.0 SD1.1 SD1.2 SITE PLAN -EXISTING SITE PLAN SITE PLAN DETAILS PARKING CALCULATIONS: 1 WAREHOUSE FACILITY 1 space per 1,000 SF of floor area devoted to storage of goods 1 space per 350 SF of floor area for spaces to support accessory office or retail sales facilities. OFFICE 5341 SF OFFICE SPACE (.85) / 350 SF = 12.9 (13) STALLS TOTAL: 33 STALLS 15645 SF/1,000 SF= 15.6 (16) STALLS DELIVERY TRUCK (12 x 45) = 12 OVERSIZE STALLS (10 x 20 ) = 21 CODE REQUIREMENT STALLS REQUIRED STALLS PROVIDED TOTAL: 15 STALLS STANDARD SIZED STALLS (9 x 18) = 15 TOTAL FOR ENTIRE SITE: 48 STALLS NOTE: ALTERNATIVE PARKING CALCULATION USED FOR WAREHOUSE PARKING, SEE ATTACHED NARRATIVE CONSTRUCTION MANAGEMENT NO.DRAWING SHEET CM1.0 CONSTRUCTION MANAGEMENT PLAN