HomeMy WebLinkAbout21-328 Project Review Notes_NCLPROJECT REVIEW NOTES
Project: 423 North Tracy Avenue ADU
Review Type: MOD/NCOA/ADU - Modification to an approved plan
Project Description:
Proposed ADU above existing greenhouse
Modifies existing approval 20-370
North and south dormers removed, window changes, window/door shifted, added closet and mechanical room to basement, change in roof pitch from 12:12 to 10:12
In the NCOD
Contributing Structure
FLU – Urban Neighborhood
In North Tracy Historic District
Parking on Street
No floodplain
Wetlands
No water features
Existing Site – 2 story SFR built in 1910, one car garage and drivewy
528 sf green house
Historic Details – Goddard house – 1909 – Contributing Structure
Detached one and ½ single family residential home
Square plan
Front porch with turned rails
Bay windows facing east and south
Asymmetrical
Off center front wood and glass entry
1/1 windows
Asphalt shingles
Boxed eaves
Skylight
Brick chimney
Green house with gable roof and metal frame construction and clad in plexiglass
Project Specifics:
DRC ZC PB CC MOD, Building Permit
Zoning Designation (s): R-2
Community Plan Designation (s): Urban Neighborhood
Address: 423 North Tracy Avenue
Proposed Use: Addition of a detached garaged with ADU above. Enclosure of 3”x6” for laundry room
Existing Use: Existing Single Family Residence
Ownership: Casey Jermyn
Past Plans: 00274 – Stewart Addition, COA
Legal Description: Bealls 3rd Addition, S07, T02 S, R06 E, BLOCK 2, Lot 19- 20
Notes:
--------------------------------------------------------------------------------------------------------------------------------------Use(s):
Principal Conditional Special Accessory
Zoning: R-2
Single house dwelling - p
ADU - p
Adjacent Uses: Residential Commercial Industrial
Residential (single family)
In NCOD: Yes No
Notes:
--------------------------------------------------------------------------------------------------------------------------------------
Lot:
Division 38.320
Lot Size: 0.172 acres – 7500 sq. ft
Building Square Feet:
House – n/a
Garage – 613 sq ft
Entry Way – 132 sf
ADU – 597 sf
Garage and ADU – 1,342 sf
No accessory building may exceed the footprint of the principal building unless such accessory building has been otherwise approved per this chapter.
Minimum Lot Area: 4000 sf (sfr) + 1,000 sf (ADU) = 5000 sf /7500 sf
Minimum floor area: ???
Lot Width Minimum: 50 ft (SFR), 40 (ADU) /49.96 ft
Maximum coverage allowed: 40%
Proposed lot coverage: ???
Maximum FAR: .???
Building footprint: ????
Density, minimum (dwellings per net acre) – 5; 0.86 required density/ 1 house provided
Stories: 2 stories
Notes:
--------------------------------------------------------------------------------------------------------------------------------------
Height: need existing height of house
Proposed Building height:
32’ proposed for home
Roof pitch -10.5/12 = 36’ maximum
23’ – 7” for ADU/Garage
Notes:
No accessory building may exceed the footprint of the principal building unless such accessory building has been otherwise approved per this chapter.
From a height of 15 feet at the minimum side setback as set forth in division 38.320, buildings must step back at a 45 degree angle away from the side property line as shown in figure
38.360.030.G below, except zero lot line situations meeting the standards of section 38.350.050.B:
No garage parking access off the alley so the 10 feet setback doesn’t apply. Please depict the rear setback for the prinicipal structure at 20 feet in which an accessory structure over
600 sq ft may be in since there is an alley present. There is no need to address the alley backup manueverabiltiy for the parking spaces as the alley is not being accessed or utilized
for the garage, but the street is.
Notwithstanding the limitations in section 38.360.030.G, a detached ADU may exceed the height of the principal building but may not exceed 22 feet in height.
--------------------------------------------------------------------------------------------------------------------------------------
Setbacks:
Setback Standards:
Front: 15 - meet
Side: 5 – meet
Rear: 20 – meet
--------------------------------------------------------------------------------------------------------------------------------------
Community Design:
Drive Access: Local Collector Arterial Deviation
South 7th Ave– Local Street
Proposed curb cut for access of Villard Street
Street Vision Triangle: Need to include street vision triangle at the intersection of the alley and Villard Street
Meets: Yes No
Parkland Required: Yes No
Notes:
Garage – 25 x 24 – 2 car
Please add in a street vision triangle for the parking space and driveway intersection.
No parking permitted in required front or side setbacks. Required parking spaces may not be located in any required front or side setback, except that detached single-household dwellings
and townhouses, and two unit structures with physically separated individual drive aisles, may have one space located within a driveway area in the required front setback for each parking
space located directly in front of the driveway area and outside of the required front setback.
Coversheet – Please change address to the 20 E. Olive Street for Planning and Building under Agenies
--------------------------------------------------------------------------------------------------------------------------------------
Project Design:
Block Frontage: Storefront Mixed Use Landscaped Gateway Other
Not applicable, except for setback (front)
Provisions: Ground Floor:
Building Placement:
Building Entrances:
Façade Transparency:
Weather Protection:
Parking Location:
Landscaping:
Sidewalk Width:
Site Design:
Sec 38.530.
Articulation standards met? Yes No
Façade width met? Yes No
Roofline modulation met? Yes No
Window design met? Yes No
Building materials met? Yes No
Blank wall treatment met? Yes No
Parking:
4 spaces on site, two in the driveway, two internal to the garage
2 space on street parking – one on Tracy, one on Villard
Landscaping:
Open Space: N/A
Notes:
--------------------------------------------------------------------------------------------------------------------------------------
Other:
NCOD Standards –
Chapter 1, 2, 3, 5 and Appendix are applicable
Chapter 1 – Rehabilitation Guidelines For Historic Properties
F. Secondary Structures
1. retaining foundation and first floor of existing green house, subordinate in character
Chapter 2 – Guidelines for All Historic Properties
D. meets this section for secondary structires
The NCOD Guidelines
Topography
Maintains assets of the existing topography
Street Patterns
Maintains traditional historic streetscape
Alley
No changes to the rear alley – will remain at traditional scale and width
Allows rear alley access to the driveway and ADU
Streetscape
No changes to sidewalk design, planting strips, and existing street trees
Landscape Design
No changes
Building Form
Similar building form as homes
Gable roof
Solid to Void Ratio
n/a
Materials
n/a
Architectural character
Contemporary interpretations of traditional details (windows, doors, etc)
Parking
Provides parking to rear
Buffers
Same as above
Site lighting
N/A
Utilities and Service areas
No changes
Chapter 3 – Guidelines for Residential Character Areas
Hierarchy of Public and Private Space
Maintains front yard and porch area with continuous primary entrance of the front porch, walkway provided from sidewalk to front door, clearly define entrance
Building Mass and Scale
No change
Roof form
Similar to traditional block (ridge line)
Secondary structures
A new secondary structure should be subordinate in height to those
buildings seen traditionally along the street front.
• Secondary structures that are no more than one or one-and-one-half
stories in height are preferred
Meets North Tracy Historic Intent
1.
Height;
2.
Proportions of doors and windows;
3.
Relationship of building masses and spaces;
4.
Roof shape;
5.
Scale;
6.
Directional expression, with regard to the dominant horizontal or vertical expression of surrounding structures;
7.
Architectural details;
8.
Concealment of non-period appurtenances, such as mechanical equipment; and
9.
Materials and color schemes (any requirements or conditions imposed regarding color schemes must be limited to the prevention of nuisances upon abutting properties and prevention of
degradation of features on the property in question. Color schemes may be considered as primary design elements if a deviation from the underlying zoning is requested).