Loading...
HomeMy WebLinkAbout009 FRAMING PLANSSS SHEET NUMBER S1.1 PIN 06079907238/50000 PROJECT NUMBER SStewart tudios 8645 SYPES CANYON ROAD BOZEMAN, MT 59715 ––––––––––––––– PH: 406.581.5212 Printed: 8/11/21 2004 MILESTONES Planning Permit Submittal: 10-13-2020 04-01-2021 06-30-2022 TRACY ADU423 NORTH TRACY AVENUEBOZEMAN, MT 59715COA (20-370) Approval: 11-18-2020 Building Permit Submittal: 03-15-2021 Plan Check Corrections (Building Permit Resubmittal): 08-10-2021 Signature Date Expires B A4.01 B A4.01 1 A4.01 1 A4.01 A A4.01 A A4.01 C A4.01 C A4.01 2 A4.01 2 A4.01 5 1/8" x 9" GLB 5 1/8" x 9" GLB Post Dn Post Dn Post Dn Post Dn Post Dn Post Dn Post Dn Post Dn (2) 2x6 HDR (2) 2x6 HDR (2) 2x6 HDR (3) 2x6 HDR5 1/8" x 12" GLB HDR(2) 2x6 HDR (2) 2x6 HDR BEDROOM BATHROOM DINING NOOK KITCHEN LIVING ROOM WEST DECK ENTRY Floor Joists: 9 1/2" TJIs 210 @ 16" o.c. 14" TJI 360 @24" o.c. Blocking 14" TJI 360 @24" o.c. Blocking 2x6 @ 16" o.c. Treated Deck Support Posts min. 4x4 Posts 4x4 min.; 1 of 3 2x6 @ 16" o.c. Treated 2 ft sq. x 8" footing w/(3) #4 ea. way, embed min. 4 ft into soil, provide 12" round concrete col. w/ min. (4) #4 vert. reinforcements w/ (5) #4 closed ties evenly spaced. Typical at all new post bases. At these locations, Bigfoot type Sonotube Base may be substituted for square footing.5 1/8" x 12" GLB5 1/8" x 13 1/2" GLBAlign with Dining Nook Wall aboveAlign with Bedroom Wall above2x10 Treated Beam(3) 2x12 Treated Continuous Beam over middle Post3 1/8" x 16 1/2" GLB 3 1/8" x 16 1/2" GLB (2) 2x12 HDR (2) 2x8 HDR (2) 2x12 HDR5 1/8" x 16 1/2" GLBB A4.01 B A4.01 1 A4.01 1 A4.01 A A4.01 A A4.01 C A4.01 C A4.01 2 A4.01 2 A4.01 STORAGE/ MECHANICAL Existing Greenhouse Space Floor Joists: 14" TJIs 360 @ 16" o.c. MECH.GARDEN W.C. B A4.01 1 A4.01 1 A4.01 A A4.01 C A4.01 2 A4.01 2 A4.01 Outlookers over end wall to first rafter @2' in from outside of wall 5 1/8" x 16 1/2" GLB Ridge BeamPost Dn Post Dn STORAGE Roof Rafters: 2x10 @ 24" o.c. Roof Rafters: 2x10 @ 24" o.c. RI RI 6" min.07 26 11 Flashing 06 11 00 Sill Plate New Hilti Quick Boltz TZ Sill Anchorage at 32" o.c. with 4" min. concrete embed. and placed in center of existing wall NOTES: 1. Existing f'c greater than 3000 psi adequate per IRC Table R402.2. 2. Based on site observations, subgrade bearing capacity conservatively assumed at 2500 psf. 3. Based on bearing capacity and IRC Table R403.1(1), 12"x16" footing adequate. 4. Based on IRC R403.1.3.1, Table R404.1.2(1), Table R404.1.2(8), R404.1.3.2.2, and R404.1.4.2 wall adequate. 5. Based on governing codes and site observations, SEOR accepts existing wall condition. Finish Grade; Slope min. 2% away from foundation 07 21 16 Rigid Insulation Existing Concrete Wall 09 29 00 Gypsum Board 07 21 16 Batt Insulation All wood, unless pressure- treated to maintain a min. clearance of 6" from grade, and a min. 2" from conc. steps/slabs #4 at 18" o.c. E.W. based on industry practice (2) #4 continuous at bottom of footing based on industry practice N 1ST FL WALLS & 2ND FL FRAMING PLAN Scale: 1/4" = 1'-0" N FNDTN & 1ST FL FRAMING PLAN Scale: 1/4" = 1'-0" N ROOF FRAMING Scale: 1/4" = 1'-0"Scale: 1 1/2"= 1'-0" 01 (E) FNDTN. WALL DTL. **WHERE DETAIL NOT EXPLICITLY SHOWN, CONTRACTOR SHALL REFERENCE IRC 2018.** FRAMING NOTES: GLULAM BEAMS: All beams 24F-V4 Grade, DF/DF OPENING HEADERS: Sawn Lumber DF-L No.2 HDR! ! TRIM STUDS!! KING STUDS (2) 2x6!! ! (1)! ! ! (1) (2) 2x8 1/2! ! (2)! ! ! (2) GLB! ! ! (2)! ! ! (3) !!!!!! LATERAL: All exterior walls to be sheathed w/ 7/16" min. panels. See detail for wall materials and attachment. FASTENER: See A1.04 & A1.05 for Fastener Schedule. All fastening to meet the requirements of the 2018 IRC. RI RI