Loading...
HomeMy WebLinkAbout010 Electrical Site PlanP J OS GENERAL ELECTRICAL NOTES A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. EWH-1 GFI GFI GFI F1 F1 F1 MAIN DISCONNECT ELECTRICAL PANEL P1 X1 E1 1 GFI WP P1-7 P1-5 P1-7 P1-5 P1-7 P1-7 P1-7 P1-5 P1-5 P1-1,3 REV. DESCRIPTION DATE REVIEWED BY: DRAWN BY: SHEET DATE SHEET TITLEMONTANASTATE UNIVERSITYMSU-CPDC MONTANA STATE UNIVERSITY BOZEMAN, MONTANA PHONE: 406.994.5413 FAX: 406.994.5665 MMI#0747.075AES BART FARMCITY WATER SERVICE95% CONSTRUCTION DOCUMENTSRPM MJS ELECTRICAL BUILDING PLAN E2.0 11-11-2021 PPA#20-0116 KEY NOTES:# 1. ANY ALTERNATE LIGHT FIXTURE SUBSTITUTIONS MUST BE SUBMITTED FOR APPROVAL PRIOR TO BID WITH MSU SUBSTITUTION REQUEST FORM. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL MOUNTING TYPES AND PROVIDE ALL REQUIRED MOUNTING ACCESSORIES. NOTES: GENERAL NOTE: X1 LED 5 NA EXIT SIGN, WITH THERMOPLASTIC HOUSING, DUAL LED HEADS, HIGH-OUTPUT NI-CAD BATTERY, RED LETTERING, AND SELF-DIAGNOSTICS. LITHONIA LHQM-LED-R-SD-HO UNIVERSAL 120 1 F1 LED 34 5,000 4000 4' LENSED INDUSTRIAL STRIP LITHONIA ZL1N-L48-5000LM-FST-MVOLT-40K -80CRI-WH-HC36 SUSPENSION 120 1 E1 LED 11 1,550 3000 LED FULL CUTOFF WALL PACK WITH INTEGRAL COLD WEATHER BATTERY BACKUP LITHONIA WPX1 LED P1 30K MVOLT E14WC DDBXD WALL 120 1 TYPE LAMPS LOAD (W) OUTPUT (LM, NOMINAL) CCT (K)DESCRIPTIONS MFR CATALOG NO. OR SERIES MOUNTING VOLTAGE NOTES LUMINAIRE SCHEDULE 1/2" = 1'-0"1 ELECTRICAL BUILDING PLAN N NOTES: PROVIDE UNIT COMPLETE WITH INTEGRAL THERMOSTAT, FACTORY MOUNTED DISCONNECT, SURFACE MOUNTING FRAME, AND ALL ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. EWH-1 QMARK CWH1207DSF METER BUILDING 5120 / 2560 240 1 1500 / 750 6.25 / 3.2 12 SEE NOTES VOLTAGE PHASE WATTS (HIGH / LOW) AMPS (HIGH / LOW) MARK MFGR. MODEL SERVES BTU/HR (HIGH / LOW) ELECTRICAL DATA WEIGHT (LBS) REMARKS ELECTRIC UNIT HEATER SCHEDULE 1. PROVIDE 120V EXTERIOR PHOTOCELL FOR AUTOMATIC ON/OFF CONTROL OF E1 LUMINAIRE. Notes: Total Est. Demand: 9 A Total Conn.: 9 A Receptacle 720 VA 100.00%720 VA Total Est. Demand: 2262 VA Lighting 107 VA 125.00%133 VA Total Conn. Load: 2253 VA HVAC 1500 VA 100.00%1500 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps: 12 A 7 A Total Load: 1470 VA 788 VA 11 0 0 1 20 A -- SPARE 12 9 SURGE PROTECTION DEVICE --30 A 2 0 0 1 20 A -- SPARE 10 7 LIGHTS Lighting 20 A 1 107 0 1 20 A -- SPARE 8 5 RECEPTACLES Receptacle 20 A 1 720 0 1 20 A -- SPARE 6 3 750 0 1 20 A -- SPARE 4 1 ELECTRIC WALL HEATER EWH-1 HVAC 20 A 2 750 0 1 20 A -- SPARE 2 CKT Circuit Description Load Classification Trip Poles A B Poles Trip Load Classification Circuit Description CKT PROVIDE WITH SURGE PROTECTION DEVICE. Notes: Enclosure: NEMA 1 Mounting: Surface Wires: 3 Mains Rating: 100 A Supply From:Phases: 1 Mains Type: MLO Location:Volts: 120/240 Single A.I.C. Rating: 4,935 Branch Panel:P1 MAIN DISC. INDOORS 02/01/22 21450 MSU AES Bart Farm Water Service Bldg. MOD