HomeMy WebLinkAbout008 Electrical LegendPOSITION OF SUPPORT WHEN REQUIRED NOTE: POSITION SERVICE TAKEOFF MIDWAY BETWEEN TRANSFORMER HANGER BRACKETS POSITION OF NEUTRAL NEUTRAL MATERIAL QTY ITEM c 2 BOLT, MACHINE, 5/8" X REQ'D LENGTH d 2 WASHER, SQUARE, 2 1/4" p CONNECTORS, COMPRESSION TYPE, AS REQ'D an 1 TRANSFORMER, 12.47 kV, SELF-PROTECTED MATERIALQTY ITEM ap 1 CLAMP, HOT LINE av 1 JUMPERS, STRANDED, AS REQ'D bv ROD, ARMOR (AS REQ'D) ek 2 LOCKNUTSXan c-d-ek p ap-bv av an 2'-6"841'-7" av 3'-6"1'-6"min. RECONNECT EXISTING SECONDARY NEW SECONDARY TO WATER METER BUILDING. PROVIDE DRIP LOOP AS SHOWN AND CAP TOP OF CONDUIT. PROVIDE SECONDARY BUSHINGS TO ACCOMMODATE TWO SERVICES 1SN 1SN 120/240V 1PH, 3W 100A PANEL P1 TRANSITION DOWN POLE TO UNDERGROUND NEW 120/240V, 1PH, 3W, 25 KVA POLE-MOUNT XFMR SEE DETAIL 5 GROUND PER GROUNDING DETAIL MAIN DISCONNECT SE RATED, NEMA 3R 120/240V, 1PH, 3W 100AS / 100AF 5,038 AIC RE-CONNECT EXISTING SECONDARY TO NEW TRANSFORMER AS REQUIRED. PROVIDE SECONDARY BUSHINGS APPROPRIATE FOR FEEDING TWO SERVICES AS SHOWN SPD N G BOND NEUTRAL TO GND AT THIS LOCATION ONLY INCOMING SERVICE NEUTRAL AND EQUIPMENT GROUND CONDUCTORS #6 CU #6 CU METAL UG WATER SERVICE BUILDING STEEL IN CONTACT WITH EARTH (10' MIN) OR WHERE STEEL COLUMN BOLTS ARE CONNECTED TO UFER ELECTRODE (WHERE APPLICABLE) UFER GND GROUNDING CONDUCTOR: TIE TO A MIN. 20FT, #5A36 ROD OR 20-FT #4 BARE CU CONDUCTOR. JOIN BY EXOTHERMIC WELDING PROCESS. LOCATE BELOW SERVICE ENTRANCE MAIN DISCONNECT. WIRE TIE TO STRUCTURAL REBAR IN FOOTING. FLOOR SLAB FOUNDATION WALL FOOTING REBAR (TYP) 10' GND RODS MAIN DISCONNECT WIDTH 2"4"24" MIN.RESURFACE TO MATCH EXISTING. PROVIDE NEW CONCRETE, ASPHALT, SEED, OR EXISTING SOD AS REQUIRED. SEE SPECS FOR MATERIAL AND INSTALLATION REQUIREMENTS. SAND OR CLEAN SOIL CONDUIT(S) AND WIRE COMPACTED BACKFILL WARNING TAPE UNDISTURBED EARTH NOTES: 1. WIDTH: MINIMUM 6" 2. WHERE POSSIBLE PUSH CONDUIT UNDER SIDEWALKS AND DRIVES TO AVOID EXCAVATION. 3. CONTRACTOR MAY USE BORING MACHINE IN LIEU OF TRENCHING WHERE CONDITIONS PERMIT. EQUIPMENT AND CONDUIT SHALL BE PRE-APPROVED BY ARCHITECT/ENGINEER. EXISTING 120/240V, 1PH, 3W, 15 KVA POLE-MOUNT XFMR RETIRE AND REPLACE WITH NEW 120/240V, 1PH, 3W, 25 KVA POLE-MOUNT XFMR PER DETAIL 2 EXISTING 120/240V, 1PH, 3W SECONDARY TO REMAIN. RECONNECT TO NEW XFMR AS REQUIRED. REV. DESCRIPTION DATE REVIEWED BY: DRAWN BY: SHEET DATE SHEET TITLEMONTANASTATE UNIVERSITYMSU-CPDC MONTANA STATE UNIVERSITY BOZEMAN, MONTANA PHONE: 406.994.5413 FAX: 406.994.5665 MMI#0747.075AES BART FARMCITY WATER SERVICE95% CONSTRUCTION DOCUMENTSRPM MJS ELECTRICAL DETAILS E0.2 11-11-2021 PPA#20-0116 N.T.S.5 SINGLE-PHASE POLE-MOUNT TRANSFORMER DETAIL N.T.S. 2 NEW ONE LINE DIAGRAM N.T.S.3 GROUNDING AND BONDING RISER DIAGRAM N.T.S.4 ELECTRICAL TRENCH DETAIL 1SN 100 3W 1 1-1/2"2#2 1#2 1#6 CONDUIT PHASE QTY AND AWG NEUTRAL AWG GROUND AWG FEEDER NUMBER AMPS WIRE QTY PER CONDUIT SETS IN PARALLEL 75 DEG COPPER FEEDER NUMBER KEY: N = INCLUDES NEUTRAL CONDUCTOR S = SINGLE PHASE NOTE: GROUNDING CONDUCTOR IS SIZED ACCORDING TO NEC 250.122 TABLE, UNLESS FEEDER NUMBER IS FOLLOWED BY AN ASTERISK (*) INDICATING THAT THE GROUNDING CONDUCTOR IS SIZED ACCORDING TO NEC 250.66 TABLE. SCHEDULE IS BASED ON 75 DEGREE C. COPPER CONDUCTORS IN NEC 310.60 TABLE. FEEDER SCHEDULE - COPPER N.T.S. 1 EXISTING ONE LINE DIAGRAM 02/01/22 21450 MSU AES Bart Farm Water Service Bldg. MOD