HomeMy WebLinkAbout007 Electrical NotesX OS OS P M M M SPD L PFC X VFD G CB PNL A208Y/120V3ø, 4W XJXD-1 X ABBREVIATIONS AND SYMBOLS GENERAL NOTES A. THE ABBREVIATIONS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT. B. THE SYMBOLS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT. C. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS, MAKING ADJUSTMENTS AS REQUIRED TO AVOID INTERFERENCE WITH EQUIPMENT SUCH AS BASEBOARD FIN-TUBE, CABINET UNIT HEATERS, ETC. ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ALL SUCH HEIGHT ADJUSTMENTS. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED. ELECTRICAL ABBREVIATIONS LEGEND A, AMP AMPERES AC ALTERNATING CURRENT A/C AIR CONDITIONING AF AMP FUSE AFC AVAILABLE FAULT CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AL ALUMINUM AS AMP SWITCH ATS AUTOMATIC TRANSFER SWITCH BAS BUILDING AUTOMATION SYSTEM BKR BREAKER BOF BOTTOM OF FIXTURE C RACEWAY/CONDUIT CB CIRCUIT BREAKER CCT COLOR RENDERING TEMPERATURE CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING C.O. RACEWAY/CONDUIT ONLY, WITH PULL STRING COD CENTER OF DEVICE CNTRL CONTROL CU COPPER (D) EXISTING TO BE DEMOLISHED DISC DISCONNECT DIST DISTRIBUTION DPDT DOUBLE POLE DOUBLE THROW DWG DRAWING EA EACH EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ELEC ELECTRIC EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT EX, EXIST EXISTING FA FIRE ALARM FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FD FUSED DISCONNECT FLR FLOOR FO FIBER OPTIC FSD FIRE SMOKE DAMPER RELAY, CONTROLLED BY ASSOCIATED SMOKE DETECTOR AND CIRCUITED BACK TO FACP FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING GEC GROUNDED ELECTRODE CONDUCTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER GFP GROUND FAULT PROTECTION GND GROUND GRC GALVANIZED RIGID CONDUIT HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSEPOWER HPS HIGH PRESSURE SODIUM HTR HEATER HVAC HEATING, VENTILATION & AIR CONDITIONING HZ HERTZ J-BOX JUNCTION BOX KVA KILOVOLT-AMPERES KW KILOWATTS LCP LIGHTING CONTROL PANEL LPW LUMENS PER WATT LTG LIGHTING LM LUMENS LV LOW VOLTAGE MAG MAGNETIC STARTER MAN MANUAL MAX MAXIMUM MC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AMPACITY MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MECH MECHANICAL MEP MECHANICAL, ELECTRICAL, PLUMBING MH METAL HALIDE MIN MINIMUM MSS MOTOR STARTER SWITCH WITH THERMAL OVERLOADS N NEUTRAL NC NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFD NON-FUSED DISCONNECT NIC NOT IN CONTRACT NO NORMALLY OPEN # NUMBER OAE OR APPROVED EQUAL OC ON CENTER OCPD OVERCURRENT PROTECTIVE DEVICE OH OVERHEAD P POLE PB PUSHBUTTON PC PLUMBING CONTRACTOR PH PHASE PNL PANEL PVC POLYVINYL CHLORIDE CONDUIT PWR POWER (R) EXISTING TO REMAIN RCPT RECEPTACLE RECEPT RECEPTACLE RGS RIGID GALVANIZED STEEL RM ROOM RVNR REDUCED VOLTAGE NON-REVERSING RVR REDUCED VOLTAGE REVERSING SP SINGLE POLE TOGGLE SWITCH SPD SURGE PROTECTIVE DEVICE (TVSS) SPEC SPECIFICATION SPST SINGLE POLE SINGLE THROW SSPB START-STOP PUSHBUTTON SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TB TELEPHONE BOARD TC TIME CLOCK TD TIME DELAY TEL TELEPHONE TR TAMPER RESISTANT TSP TWISTED SHIELDED PAIR TTB TELEPHONE TERMINAL BOARD TYP TYPICAL UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VA VOLT-AMPERES VFD VARIABLE FREQUENCY DRIVE W WATTS WP WEATHERPROOF W/O WITHOUT XFMR TRANSFORMER Y WYE-CONNECTED Δ DELTA-CONNECTED ø PHASE ELECTRICAL LIGHTING FIXTURE LEGEND RECESSED LED FIXTURE - "a" & "b" DESIGNATES SWITCH EXIT SIGN - WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. RECESSED EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH SURFACE WALL MOUNT LED FIXTURE LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG EMERGENCY LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG POLE MOUNTED FIXTURE LIGHTED BOLLARD PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE DUAL HEAD EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR CEILING MOUNT WALL MOUNTED SCONCE SURFACE DOWNLIGHT SURFACE EMERGENCY DOWNLIGHT RECESSED CAN DOWNLIGHT RECESSED CAN EMERGENCY DOWNLIGHT RECESSED CAN WALL WASHER TRACK LIGHTING. SEE FIXTURE SCHEDULE AND LIGHTING PLANS. COMBINATION EXIT SIGN/ EGRESS LIGHTING UNIT - WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE. LIGHTING CONTROL LEGEND OCCUPANCY SENSOR - DUAL TECHNOLOGY CEILING MOUNT: WATTSTOPPER DT-300, OR EQUAL WALL MOUNT: WATTSTOPPER DT-200, OR EQUAL WALL MOUNTED SHALL BE AT +96", UNO PROVIDE WITH BZ-50 POWER PACKS AS NEEDED. TOGGLE SWITCH (MOUNT AT +48", UNO) "X" INDICATES TYPE: BLANK -SINGLE POLE 3 - INDICATES THREE-WAY 4 - INDICATES FOUR-WAY D - INDICATES DIMMER SWITCH PHILIPS SUNRISE - ON/OFF K - INDICATES KEYED SWITCH T - INDICATES TIMER P - INDICATES PILOT LIGHT OS - INDICATES WALL SWITCH OCC SENSOR WATTSTOPPER DW100 (SINGLE OR DUAL DW-200 SWITCH) OSD - INDICATES WALL SWITCH OCC SENSOR WITH 0-10V DIMMING - WATTSTOPPER PW-311 a - INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE a b - INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE b ab - INDICATES LIGHTING SWITCHES WITH MULTIPLE ZONES PHOTOCELL - EXTERIOR STANDARD LIGHTING CONTROLS: SWITCHES AND LINE VOLTAGE DIMMERS ELECTRICAL ONE-LINE LEGEND MOTOR CT AND CUSTOMER POWER METER UTILITY ELECTRIC METER AND BASE (BASE BY CUSTOMER) SURGE PROTECTION DEVICE LIGHTNING ARRESTER, TYPE 1 SPD, MOUNTED ON EXTERIOR OF MAIN SWITCHGEAR (SQUARE D NO. SDSA3650, OAE) STRESS RELIEF CONE POWER FACTOR CORRECTION CAPACITOR EQUIPMENT TOGGLE DISCONNECT SWITCH "X" INDICATES TYPE: F - FUSTAT M - MOTOR STARTER SWITCH W/ THERMAL OVERLOADS CONTACTOR NORMALLY OPEN, NORMALLY CLOSED TRANSFORMER, 3-PH, 3-WIRE DELTA CONNECTION TRANSFORMER, 3-PH, 4-WIRE GROUNDED WYE CONNECTION AUTOMATIC TRANSFER SWITCH VARIABLE FREQUENCY DRIVE FIXED MOUNT LV BREAKER FUSED SWITCH ("XXAS/XXAF" - SW AND FUSE AMP RATING) GENERATOR WALL MOUNTED BREAKER THERMAL OVERLOAD ELEMENT DISCONNECT SWITCH ("XXAS" = SWITCH AMP RATING) FUSED DISCONNECT SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING) COMBINATION MOTOR STARTER (STR SIZE, TYP, AS, AF, SEE MEP COORDINATION SCHEDULE) SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, PHASE, NUMBER OF WIRES WHEN INDICATED ELECTRICAL POWER LEGEND PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TO EACH DEVICE (PANEL NAME - CIRCUIT NUMBER). BRANCH CIRCUIT WIRE SIZE IS #12, UNO. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENT CIRCUITING, SEE MEP COORDINATION SCHEDULE. "X" INDICATES TYPE: GFI - GROUND FAULT INTERRUPTER WP - WEATHERPROOF WHILE-IN-USE COVER U - PROVIDE WITH (2) USB PORTS TR - TAMPER RESISTANT PANELBOARD OR LOAD CENTER JUNCTION BOX SIMPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) DUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) QUADRUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO) SPECIAL PURPOSE RECEPTACLE (MOUNT AT +18", UNO) "X" INDICATES TYPE: A - NEMA 5-20R, #12 CU; B -NEMA 5-30R, #10 CU; C -NEMA 5-50R, #8 CU; D - NEMA 6-20R, #12 CU; E - NEMA 6-30R, #10 CU; F -NEMA 6-50R, #8 CU; G -NEMA 14-20R, #12 CU; H - NEMA 14-30R, #10 CU; I - NEMA 14-50R, #8 CU* * +4" AFF FOR RANGE SURFACE MOUNTED RACEWAY RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN FINISHED SPACES, EXPOSED IN UNFINISHED SPACES RACEWAY BELOW FLOOR OR BELOW GRADE RACEWAY STUB-OUT WITH CAPPED END RACEWAY STUB-OUT WITH BRUSHED END GROUNDING BUS PUSHBUTTON (MOUNT AT +48", UNO) "X" INDICATES TYPE: EPO -EMERGENCY POWER OFF ADA -HANDICAPPED ACCESSIBLE DOOR (DEVICE BY OTHERS) ODO - OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS) ABOVE COUNTER RECEPTACLE - MOUNT AT +4" ABOVE BACKSPLASH ELECTRICAL PROJECT GENERAL NOTES A. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID. B. MONTANA STATE UNIVERSITY OWNS THE PRIMARY ELECTRICAL MEDIUM VOLTAGE DISTRIBUTION SYSTEM ON PROPERTY, RATED AT 7.2/12.47KV. CONTRACTOR SHALL PROVIDE ALL REQUIRED MEDIUM VOLTAGE WORK SHOWN ON PLANS AS PART OF PROJECT SCOPE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET. C. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE AT WWW.NECANET.ORG. D. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS. E. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE- RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES. F. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED FOR AT LEAST 75 DEGREES C. G. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES SHALL BE AS FOLLOWS: #10 AWG CU FOR RUNS BETWEEN 100 AND 200 LINEAR FEET, #8 AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, AND AS CALCULATED BY THE CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS REQUIRED. H. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT. REV. DESCRIPTION DATE REVIEWED BY: DRAWN BY: SHEET DATE SHEET TITLEMONTANASTATE UNIVERSITYMSU-CPDC MONTANA STATE UNIVERSITY BOZEMAN, MONTANA PHONE: 406.994.5413 FAX: 406.994.5665 MMI#0747.075AES BART FARMCITY WATER SERVICE95% CONSTRUCTION DOCUMENTSRPM MJS ELECTRICAL LEGENDS E0.1 11-11-2021 PPA#20-0116 02/01/22 21450 MSU AES Bart Farm Water Service Bldg. MOD