Loading...
HomeMy WebLinkAboutC3.0SITEANDUTILITYPLAN_202108170 30 SCALE: 1" = 30' 601530 NORTH C3.0SITE AND UTILITY PLANissue date dateprojectownersheet phase revision project #P:\20078_01_First_Security_Bank_Cattail_Bozeman\CADD_C3D\PRODUCTION_DWG\20078.01_SITE PROD.dwg Aug 17, 2021 - 2:45pm20042 08.17.21 FIRST SECURITY BANKGLACIER BANCORP4TH SP SUBMITTAL 08.17.21 4TH SP SUBMITTAL LOT AREA: 1.449 ACRES LEGAL DESCRIPTION: LOT 13, GALLATIN CENTER SUB. PH4 PLAT J-423 ZONING: B-2 1 SPACE PER 300 SQ. FT OF GROSS FLOOR AREA 5,100SQ. FT. / 300SF+5,100SQ. FT./250SF+2*3 LANES = 43 SPACES PARKING CALC: REQUIRED: 42 STANDARD + 2 ADA ACCESSIBLE = 44 SPACES PROPOSED: GENERAL NOTES: 1.ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011, WITH ADDENDUM. 2.EXISTING UNDERGROUND INSTALLATIONS AND PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS. 3.UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE WHERE IS PROJECT IS LOCATED AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED. 4.ANY EXISTING OR NEW VALVES WHICH CONTROL THE C.O.B.'S WATER SUPPLY SHALL BE OPERATED BY C.O.B. PERSONNEL ONLY. 5.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24 HOURS PRIOR TO COMMENCING ANY WORK. 6.THE CONTRACTOR SHALL FIELD VERIFY LINE AND GRADE OF EXISTING CONNECTIONS. SANITARY SEWER: 7.UNLESS OTHERWISE NOTED, ALL SANITARY SEWER SERVICES ARE TO BE 4" SDR 26 PVC INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02730-2. 8.UTILITY TRENCHES PER C.O.B. STANDARD DRAWING NUMBER 02221-1. WATER: 9.USE JOINT RESTRAINT AT ALL FITTINGS AND VALVES AS SPECIFIED IN RESTRAINT TABLES. 10.UNLESS OTHERWISE SPECIFIED, ALL WATER SERVICES ARE ARE TO BE 2" TYPE K COPPER PIPE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02660-6. 11.INSTALL IN TRENCH PER C.O.B. STANDARD DRAWING NUMBER 02221-1. STORM SEWER: 12.STORM SEWER MANHOLES SHALL BE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02720-3 WHEN THE DISTANCE FROM THE RIM TO THE LOWEST INVERT IS GREATER THAN OR EQUAL TO SIX FEET. INSTALL PER C.O.B. STANDARD DRAWING NUMBER 02720-4, WHEN THIS DISTANCE IS LESS THAN SIX FEET. 13.24"x36" INLETS SHALL BE INSTALLED PER C.O.B. STANDARD DRAWING NUMBER 02720-1A FIBER OPTIC GAS PIPELINE SANITARY SEWER STORM DRAIN TELEVISION/CABLE WATER CURB AND GUTTER EDGE OF ASPHALT EDGE OF GRAVEL EXISTING WATER VALVE FIRE HYDRANT LEGEND SANITARY SEWER MANHOLE FOUND CORNER MONUMENT AS NOTED EASEMENT LOT LINE SIGN PROPOSED UNDERGROUND POWER ASPHALT CONCRETE LIGHT POLE 12,056 SQ. FT. / 1 STALL/1000SF = 12 BIKE SPACES 12 BIKE SPACES 1 SPACE PER 250 SQ. FT OF GROSS FLOOR AREA 2 SPACES PER DRIVE THROUGH LANE SITE DATA REQUIRED PROVIDED (MIN) FRONT BUILDING SETBACK 10FT ±90FT SIDE BUILDING SETBACK 8FT ±8FT REAR BUILDING SETBACK 10FT ±80FT LOT COVERAGE 100%±10% DRIVE THROUGH LANE DIMENSIONS LANE REQUIRED (MIN)PROVIDED LANE 1 108FT 160FT LANE 2 108FT 145FT LANE 3 108FT 120FT LENGTHS ARE MEASURED FROM THE SOUTH END OF THE CURB ISLAND TO THE END OF THE PROPOSED STRIPING ALONG THE CENTERLINE OF EACH LANE SNOW STORAGE AREA