Loading...
HomeMy WebLinkAboutCS-300OverallSitePlanNORTH030SCALE: 1" = 30'601530OVERALL SITE PLANCS-300FIBER OPTICGAS PIPELINESANITARY SEWERSTORM DRAINTELEVISION/CABLEWATERCURB AND GUTTEREDGE OF ASPHALTEDGE OF GRAVELEXISTINGWATER VALVEFIRE HYDRANTLEGENDSANITARY SEWER MANHOLEFOUND CORNER MONUMENT AS NOTEDEASEMENTLOT LINEPROPOSEDUNDERGROUND POWERASPHALTCONCRETELIGHT POLE/LIGHTSSNOW STORAGE AREAGENERAL NOTES:1.ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARDSPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATEDMARCH 31, 2011, WITH ADDENDUM.2.EXISTING UNDERGROUND INSTALLATIONS AND PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THEBEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OFSUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAYNOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALLUTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.3.UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THERESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE WHERE IS PROJECT IS LOCATED AND BYA PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKINGTECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.4.ANY EXISTING OR NEW VALVES WHICH CONTROL THE C.O.B.'S WATER SUPPLY SHALL BE OPERATED BY C.O.B.PERSONNEL ONLY.5.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24 HOURS PRIOR TO COMMENCINGANY WORK.6.THE CONTRACTOR SHALL FIELD VERIFY LINE AND GRADE OF EXISTING CONNECTIONS.SANITARY SEWER:1.UNLESS OTHERWISE NOTED, ALL SANITARY SEWER SERVICES ARE TO BE 4" SDR 26 PVC INSTALLED PER C.O.B.STANDARD DRAWING NUMBER 02730-2.2.UTILITY TRENCHES PER C.O.B. STANDARD DRAWING NUMBER 02221-1.WATER:1.USE JOINT RESTRAINT AT ALL FITTINGS AND VALVES AS SPECIFIED IN RESTRAINT TABLES.2.UNLESS OTHERWISE SPECIFIED, ALL WATER SERVICES ARE ARE TO BE 2" TYPE K COPPER PIPE INSTALLED PERC.O.B. STANDARD DRAWING NUMBER 02660-6.3.INSTALL IN TRENCH PER C.O.B. STANDARD DRAWING NUMBER 02221-1.20400.00PROJ. NO.DATE:2021-0715© DRUMBEATSITE PLAN CD SETSCALE:SHEET NUMBERSHEET TITLE:ISSUED FOR:INDUSTRY BOZEMAN650 South 500 WestSalt Lake City, UT 84101www.drumbeat.uswww.qfactorsolutions.comTECHNOLOGY WAY BOZEMAN, MT 59718 106 E BABCOCK, SUITE L1Bozeman, MT 59715www.sandersonstewart.com PARKING CALCULATION: REQUIRED:STANDARD = 260 SPACESPROPOSED:COMPACT = 3 SPACES83,653 GSF 85% SF ADJUSTMENT = 71,105 USEABLE SF71,105SF/250SF = 284 REQUIRED SPACESBICYCLE REDUCTION:284 SPACES - 12 SPACES = 272 REQUIRED SPACESEV = 4 SPACESACCESSIBLE = 5 SPACESVAN ACCESSIBLE = 2 SPACESTOTAL BIKE = 32 SPACESCOVERED BIKE = 24 SPACESTOTAL VEHICLE = 274 SPACES