Loading...
HomeMy WebLinkAboutAS-101Level1-FloorPlanA B C D 1 2 3 4 5 6 7 8 10 9 11 13 14 15 16 17 18 H G F E 12 1.5 2.5 3.5 4.5 5.5 6.5 7.5 A.3 A.6 B.3 B.6 C.3 C.6 10.5 11.5 12.5 13.5 14.5 15.5 16.5 17.5 E.3 E.6 F.3 F.6 G.3 G.6 8.2 8.6 B.9B.5 C.5 RECEP TRAINING EVENTS KITCHEN CONF OFFICE CIRC OFFICE OFFICE OFFICE CONF 108' - 0"108' - 0"192' - 0" RR RR RR ELEV CONF TABLE GRAB+GO CONF MAIL HUDDLE HUDDLE HUDDLE STORAGE MDF HUDDLE JAN221' - 6"LOBBY VEST ELECT ELECT PATIO PATIO PATIO PATIO HUDDLE SHOWERSHOWER WATER ENTRY/FIRE RISER CIRC AS-2004 AS-200 5 AS-200 3 AS-200 7 AS-2002 AS-200 1 AS-200 6 RR HUDDLE MNGMT PROJ. NO. DATE: © DRUMBEAT SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: 650 South 500 West Salt Lake City, UT 84101 www.drumbeat.us www.qfactorsolutions.com 7/22/2021 12:34:42 PMBIM 360://Industry Bozeman/20400_Industry Bozeman_A19_Central.rvt3/64" = 1'-0"TECHNOLOGY BLVDBOZEMAN, MT 5971820400.00 2021-0715 SITE PLAN CD SET LEVEL 1 - FLOOR PLAN AS-101 INDUSTRY BOZEMAN PROJECT FLAGNOTES NO. FLAGNOTE FLOOR PLAN NOTES 1 EL.100'-0" (LEVEL 1) EQUATES TO USGS DATUM ELEVATION OF 4868.5. 2 EXTERIOR DIMENSIONS ARE TO FACE OF SHEATHING, FACE OF CONCRETE/MASONRY, COLUMN CENTERLINE, OR CENTERLINE OF WINDOW U.N.O. 3 INTERIOR DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE/MASONRY, OR COLUMN CENTERLINE U.N.O. DIMENSIONS DESIGNATED AS "CLEAR" OR "HOLD" SHALL BE MAINTAINED. 4 SEE SHEET G-501 FOR PARTITION TYPES. SEE CODE PLANS, G-100 SERIES SHEETS, FOR RATINGS OF PARTITIONS. METAL STUD PARTITIONS ARE TYPE 23C, U.N.O. WOOD STUD PARTITIONS ARE TYPE W24C U.N.O. 5 PARTITION TYPES INDICATED CONTINUE AROUND CORNERS U.N.O. 6 MAINTAIN CONTINUITY OF RATED PARTITIONS AT HEAD AND BOTTOM OF PARTITION AND AT JOINTS WITH DISSIMILAR PARTITIONS WITH LISTED JOINT ASSEMBLIES. 7 WHERE TWO DIFFERING PARTITION TYPES ABUT ALONG A CONTINUOUS LINE, THE CONTINUOUS FINISHED SURFACE OF THESE PARTITIONS SHALL ALIGN U.N.O. 8 WHERE DOORS ARE NOT SPECIFICALLY LOCATED, PROVIDE A HINGE-SIDE JAMB DIMENSION OF 4" FROM DOOR OPENING TO ADJACENT PERPENDICULAR PARTITION. 9 WHERE MECHANICAL DUCTWORK PENETRATES A COMPONENT OF THE FIRE-RATED ASSEMBLY, PROVIDE FIRE AND/OR SMOKE DAMPERS IN ACCORDANCE WITH IBC CHAPTER 7. 10 PROVIDE 1/2" CLEARANCE FROM DUCTWORK FOR VIBRATION ISOLATION. 11 GC TO PROVIDE BLOCKING FOR ANCHORING OF ACCESSORIES, GRAB BARS, EQUIPMENT AND FURNITURE. REFER TO INTERIOR DESIGN DRAWINGS FOR LOCATIONS AND TYPE. CASE GOODS HIGHER THAN COUNTER HEIGHT TO BE SECURELY ANCHORED TO BLOCKING IN WALL. BLOCKING REQUIRED FOR WALL-MOUNTED TELEVISIONS. BLOCKING REQUIRED FOR CLOSET RODS (CONCEALED METAL GYPSUM ANGLES REQUIRED). 12 FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF CASEWORK, MILLWORK AND OTHER BUILT-IN ITEMS. 13 SEE SHEET G-401 FOR MOUNTING HEIGHTS AND BLOCKING FOR FUTURE GRAB BARS. 14 SEE SHEET A-600 FOR DOOR SCHEDULE. 15 SEE INTERIOR DRAWINGS FOR FINISHES, ELEVATIONS, FIXTURES, ACCESSORIES, AND TOILET PARTITIONS. 3/64" = 1'-0"1 LEVEL 1 - FLOOR PLAN 0'10'-8"21'-4"42'-8" 7/21/2021