Loading...
HomeMy WebLinkAboutL600Irrigation Plan_08172021UPUP DNDNDNDNDNDNDNUP UPUPUPUPUPUPUP UPUPDNBLDG 3-4FFE: 4798.00W. VILLARD STREETN. TRACY AVENUE BFCPWC1.5 IRR1.5 IRR1.5 IRR1.5 IRR1.5 IRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRRIRR IRR IRR IRRIRRIRR IRRIRR IRRIGATION NOTES AND SPECIFICATIONS1.ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER.2.IRRIGATION MAIN LINE TO BE 1.5" SCH. 40 PVC PIPE OR 150 PSI POLY PIPE.3.ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERS. BUBBLERS TO BE EVENLY DISTRIBUTEDAROUND BASE OF TREE WITH FOUR (4) EVENLY SPACED BUBBLERS/EMITTERS.4.TREES AND SHRUBS PLACED WITHIN PLANTING BEDS MAY UTILIZE DRIP IRRIGATION. DRIP IRRIGATIONTO BE ADJUSTED PER REQUIREMENTS OF EACH INDIVIDUAL PLANT.5.ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVE DEDICATED BUBBLERS. BUBBLERS TOBE EVENLY DISTRIBUTED AROUND BASE OF SHRUB WITH TWO (2) EVENLY SPACED BUBBLERS/EMITTERS.6.ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATED WITH DEDICATED DRIP TUBING. DRIPEMITTERS TO BE ADJUSTED PER REQUIREMENTS OF EACH INDIVIDUAL PLANT.RECOMMENDED EMITTERS PER PLANT TYPE:PERENNIALS- (1) 0.5 GPH EMITTERSHRUBS- (2) 1.0 GPH EMITTERS/0.25-1.0 GPM BUBBLERSTREES- (4) 1.0 GPH EMITTERS/0.25-1.0 GPM BUBBLERS***TREES UTILIZING DRIP IN PLANTING BEDS MAY NEED ADDITIONAL EMITTERS TO MEET WEEKLYWATERING REQUIREMENTS.7.LAWN AND SEED AREAS TO BE IRRIGATED WITH SPRAY OR ROTOR OVERHEAD IRRIGATION AS INDICATEDON PLAN.8.ALL HEADS MUST ACHIEVE HEAD-TO-HEAD COVERAGE FOR SOD AREAS.9.ALL SPRAY HEADS ARE TO USE MSMT (MULTI-SPRAY, MULTI-TRAJECTORY) HIGH WATER EFFICIENCYSYSTEM NOZZLES.10.ALL SPRAY HEADS ARE TO BE INSTALLED AND ADJUSTED TO MINIMIZE OVERSPRAY ONTO ADJACENTPAVED SURFACES.11.SYSTEM SHALL UTILIZE A "SMART" CONTROLLER WITH WI-FI AND AUTOMATIC SCHEDULINGCAPABILITIES THAT CORRESPOND TO CHANGES IN LOCAL WEATHER CONDITIONS12.SYSTEM SHALL UTILIZE WEATHER / MOISTURE MONITOR, VERIFY BEST LOCATION IN FIELD.13.BACK FLOW ASSEMBLY AND BLOWOUT ASSEMBLY SHALL BE LOCATED IN THE RISER ROOM. IT IS THERESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO COORDINATE INSTALLATION PER LOCAL CODESAND ORDINANCES AS WELL AS WITH ARCHITECTURE AND ALL OTHER TRADES.14.POWER SOURCE FOR IRRIGATION CONTROLLER TO BE COORDINATED WITH ELECTRICAL ENGINEER,ELECTRICAL CONTRACTOR AND LANDSCAPE CONTRACTOR.15.DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUS OBSTRUCTIONS OR GRADE CHANGES AREPRESENT.16.ALL INFORMATION TO BE FIELD-VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION.17.THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT 'AS-BUILT' IRRIGATION PLAN ON SITE ATALL TIMES.IRRIGATIONTYPEIRRIGATION SCHEDULETOTALAREA / QTYANNUALET RATETOTALANNUAL H2O1,210 SF29 IN / SF21,861 GALH.E. BLVDSPRAYIRRIG. SOD500 SF29 IN / SF9,034 GAL14 TREES6,860 SF231 GAL /WEEK4,158 GAL28 SHRUBS560 SF210 GAL /WEEK3,780 GAL321PERENNIALS963 SF642 GAL /WEEK11,556 GALTOTAL ANNUAL H2O REQUIRED: 50,839 GALTOTAL ACRE FEET PER YEAR: 0.15 ACRE FEETH.E. SPRAYIRRIG. SODH.E. TREEBUBBLERH.E. SHRUBDRIP IRRIG.H.E.PERENN.DRIP IRRIG. SYM DESCRIPTIONIRRIGATION LEGEND1.5" PVC MAINLINE, SCH 40 PVC IRRIGATION CONTROLLERBACKFLOW PREVENTER1.5"CONNECTION POINT1, L700WEATHER STATIONSIZE DETAIL BFCPWC2, L7003, L7005, L700CONTROL VALVE9,11,12 L700DRIP ZONE VALVE10, L7001.0" LATERAL LINE, SCH 40 PVC OR POLYETHYLENE5, L700IRRIGATION SLEEVE, 4" Min. SCH 40 PVC 6, L700IRR1.5 IRR1.0"1.0"1L6001"=10'-0"Irrigation PlanIrrigation PlanL 600105020Ndesign5la.com406.587.4873dateissuedrawn by:checked by:filename:z:\north central 3-4\autocad\01_sheets\l600_ncb3-building3-4_irrigation.dwg THE HENRY North Tracy Avenue Bozeman, Montana 59715 KHM/HU TMS 06/08/21SITE PERMITREVIEW08/17/21SITE PERMITREV 1AASITE PERMITREVIEW RC1