HomeMy WebLinkAboutTCFStormwaterReport043019 STORMWATER
DESIGN REPORT & CALCULATIONS
FOR:
TOWN & COUNTRY FOODS
BOZEMAN, MT
Prepared By:
M
MADISON
ENGINEERING
Madison Engineering
895 Technology Drive, Suite 203
Bozeman, MT 59718
(406) 586-0262
J.O. 18-121
MAY 2019
Ferguson Farms-Block 5
Stormwater Existing Retention Basin Summary
and Redesign Calculations
WEST SIDE
Retention Pond#1 South-C&H Design Report(June 2013)
Revised volume held between contours-Madison Engineering(April 2019)
Cumulative
Contour Area(ftZ) Delta V(ft) Volume(ft')
4819.00 2,014
4820.0 3,254 2,634 2,634
4821.0 4,610 3,932 6,566
4821.5 5,347 2,489 9,055
Redesign storage volume(ft)= 9,055
As constructed(existing)storage volume(ft3)= 2,521
Retention Pond#1 North-C&H Design Report(June 2013)
Revised volume held between contours-Madison Engineering(April 2019)
Cumulative
Contour Area(ft2) Delta V(ft') Volume(ft3)
4817.00 1,013
4818.0 1,758 1,386 1,386
4819.0 2,633 2,196 3,581
4820.0 3,637 3,135 6,716
482&5 4,204 1,960 8,676
Redesign storage volume(ft)= 8,676
As constructed(existing)storage volume(ft3)= 20,982
Redesign combined storage volume(ft)= 17.732
As constructed(existing)storage volume(ft3)= 23.503
C&H design combined storage volume(ft)= 17,604 See page 16 of C&H Report
EAST SIDE
Retention Pond#2 South-C&H Design Report(June 2013)
Revised volume held between contours:
Stormtank System
Stormtalk Modules Area 22'x 132' 2,904 sf
Stormtalk Modules Height 36 inches
Stormtalk Modules Volume 8,712 cf
94%effcieny volume 8,189 cf
Redesign storage volume(ft)= 8,189
As constructed storage volume(ft3)= 3,368
Retention Pond-#2 North-C&H Design Report(June 2013)
Stormtank System
Stormtalk Modules Area 22'x 132' 2,904 sf
Stormtalk Modules Height 36 inches
Stormtalk Modules Volume 8,712 cf
94%effcieny volume 8,189 cf
Redesign storage volume(ft)= 8,189
As constructed storage volume(ft3)= 4,016
Redesign combined storage volume(ft)= 16,379
As constructed combined storage volume(ft3)= 7.384
C&H design combined storage volume(ft)= 15.934 See page 16 of C&H Report
Ferguson Farms-Stormwater Retention Basin Summary-04-27-19
TOWN & COUNTRY FOODS
Lot 1 -4 Block 5 Ferguson Farms Subd.
Stormwater Calculations
East Parking Lot
(Reference: Bozeman Stormwater Master Plan - 1982)
Design Rainfall Freq. 25 year(see page III -5 of master plan)
IDF coefficient a 0.78
IDF coefficient b
IDF coefficient n 0.64
Pre-development Calculations
C
Areas (ft): Impervious 86,089 0.90
Landscaped 7,486 0.20
Total: 93,575
total area: 2.15 acres
composite C: 0.84
Overland t,
average slope: 3 percent
travel distance: 310 feet
t,: 6 minutes
Channel t,
channel t�. minutes
Total t,: 6 minutes
intensity at tc(fig 23): 3.46 in/hr
pre-devel peak runoff: 6.28 cfs
Stormwater Run-off Calculations- East Pavement
TOWN &COUNTRY FOODS
Lot 1 -4 Block 5 Ferguson Farms Subd.
Stormwater Calculations
Roof Area
(Reference: Bozeman Stormwater Master Plan - 1982)
Design Rainfall Freq. 25 year(see page III -5 of master plan)
IDF coefficient a 0.78
IDF coefficient b
IDF coefficient n 0.64
Pre-development Calculations
C
Areas (ft): Impervious 33,932 0.90
Landscaped 0.20
Total: 33,932
total area: 0.78 acres
composite C: 0.90
Overland t,
average slope: 0.5 percent
travel distance: 250 feet
tc: 7 minutes
Channel t.
channel t, minutes
Total tr: 7 minutes
intensity at t,(fig 23): 2.96 in/hr
pre-devel peak runoff: 2.08 cfs
Stormwater Run-off Calculations- Roof
TOWN & COUNTRY FOODS
Lot 1 -4 Block 5 Ferguson Farms Subd.
Stormwater Calculations
West Pavement Area
(Reference: Bozeman Stormwater Master Plan - 1982)
Design Rainfall Freq. 25 year(see page III -5 of master plan)
IDF coefficient a 0.78
IDF coefficient b
IDF coefficient n 0.64
Pre-development Calculations
C
Areas (ft): Impervious 12,721 0.90
Landscaped 670 0.20
Total: 13,390
total area: 0.31 acres
composite C: 0.87
Overland t,
average slope: 1.65 percent
travel distance: 250 feet
tc: 6 minutes
Channel t,
channel t, minutes
Total t,: 6 minutes
intensity at tc(fig 23): 3.45 in/hr
pre-devel peak runoff: 0.92 cfs
Stormwater Run-off Calculations-West Pavement
TOWN &COUNTRY FOODS
Lot 1 -4 Block 5 Ferguson Farms Subd.
Pipe Capcity Calculations
25-year Storm Event
Basin Area (sf) C Value I in/hr) Q(cfs)
East 93,575 0.84 3.46 6.28
Roof 33,932 0.78 2.96 2.08
West 13,390 0.87 3.45 0.92
Capacity Contributing In Flow
Pipe Size Slope (%) (cfs) Area Q(cfs)
A 18" 0.3 6.83 East 6.28
B 18" 0.3 6.83 East 6.28
C 15" 0.5 5.94 Roof 2.08
D 21" 0.2 9.21 East& Roof 8.36
E 21" 0.25 10.3 E, W& Roof 9.28
Pipe Capcity Calculations
Town & Country - 15" PVC Pipe Capacity
Project Description
Friction Method Manning Formula
Solve For Full Flow Capacity
Input Data
Roughness Coefficient 0.010
Channel Slope 0.5 %
Normal Depth 15 in
Diameter 15 in
Discharge 5.94 ft'/s
Results
Discharge 5.94 ft'/s
Normal Depth 15 in
Flow Area 1.23 ftZ
Wetted Perimeter 3.93 ft
Hydraulic Radius 4 in
Top Width 0.00 ft
Critical Depth 0.99 ft
Percent Full 100.0
Critical Slope 0.00539 ft/ft
Velocity 4.84 ft/s
Velocity Head 0.36 ft
Specific Energy 1.61 ft
Froude Number 0.00
Maximum Discharge 6.39 ft'/s
Discharge Full 5.94 ft/s
Slope Full 0.00500 ft/ft
Flow Type SubCritical
GVF Input Data
Downstream Depth 0 in
Length 0.00 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0 in
Profile Description
Profile Headloss 0.00 ft
Average End Depth Over Rise 0.00
Bentley Systems,Inc. Haestad Methods SoIE*odd)sil6vMaster V81(SELECTserles 1) 108.11.01.03]
4/27/2019 6:04:31 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06796 USA +1-203-755-1666 Page 1 of 2
Town & Country - 15" PVC Pipe Capacity
GVF Output Data
Normal Depth Over Rise 100.00 %
Downstream Velocity Infinity ft/s
Upstream Velocity Infinity ftts
Normal Depth 15 in
Critical Depth 0.99 ft
Channel Slope 0.5
Critical Slope 0.00539 fttft
Bentley Systems,Inc. Haestad Methods SolBgatld$eFftwMaster V81(SELECTseries 1) [08.11.01.03]
4/27/2019 6:04:31 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2
Town & Country - 18" PVC Pipe Capacity
Project Description
Friction Method Manning Formula
Solve For Full Flow Capacity
Input Data
Roughness Coefficient 0.010
Channel Slope 0.3
Normal Depth 18 in
Diameter 18 in
Discharge 6.83 ft°/s
Results
Discharge 6.83 fN/s
Normal Depth 18 in
Flow Area 1.77 ftz
Wetted Perimeter 4.71 ft
Hydraulic Radius 5 in
Top Width 0.00 ft
Critical Depth 1.01 ft
Percent Full 100.0
Critical Slope 0.00394 ft/ft
Velocity 3.86 ft/s
Velocity Head 0.23 ft
Specific Energy 1.73 ft
Froude Number 0.00
Maximum Discharge 7.34 ft'/s
Discharge Full 6.83 ft'/s
Slope Full 0.00250 ft/ft
Flow Type SubCritical
GVF Input Data
Downstream Depth 0 in
Length 0.00 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0 in
Profile Description
Profile Headloss 0.00 ft
Average End Depth Over Rise 0.00
Bentley Systems,Inc. Haestad Methods SolModdp#IbwMaster V81(SELECTserles 1) [08.11.01.03]
4/2712019 5:38:42 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2
Town & Country - 18" PVC Pipe Capacity
GVF Output Data
Normal Depth Over Rise 100.00 %
Downstream Velocity Infinity fits
Upstream Velocity Infinity ft/s
Normal Depth 18 in
Critical Depth 1.01 ft
Channel Slope 0.3 %
Critical Slope 0.00394 ft/ft
Bentley Systems,Inc. Haestad Methods SolBtlatlBpaFilNrMaster V81(SELECTseries 1) [08.11.01.03]
4/27/2019 5:38:42 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2
Town & Country - 21" PVC Pipe Capacity 0.20%
Project Description
Friction Method Manning Formula
Solve For Full Flow Capacity
Input Data
Roughness Coefficient 0.010
Channel Slope 0.20 %
Normal Depth 21 in
Diameter 21 in
Discharge 9.21 ft3/s
Results
Discharge 9.21 ft'/s
Normal Depth 21 in
Flow Area 2.41 ft2
Wetted Perimeter 5.50 ft
Hydraulic Radius 5 in
Top Width 0.00 ft
Critical Depth 1.13 ft
Percent Full 100.0
Critical Slope 0.00357 ft/ft
Velocity 3.83 ft/s
Velocity Head 0.23 ft
Specific Energy 1.98 ft
Froude Number 0.00
Maximum Discharge 9.91 ft'/s
Discharge Full 9.21 ft/s
Slope Full 0.00200 ft/ft
Flow Type SubCritical
GVF Input Data
Downstream Depth 0 in
Length 0.00 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0 in
Profile Description
Profile Headloss 0.00 ft
Average End Depth Over Rise 0.00
Bentley Systems,Inc. Haestad Methods SolMadd#ilbrrMaster V81(SELECTseries 1) [08.11.01.033
4/27/2019 7:36:43 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2
Town & Country - 21" PVC Pipe Capacity @ 0.20%
GVF Output Data
Normal Depth Over Rise 100.00
Downstream Velocity Infinity ft/s
Upstream Velocity Infinity ft/s
Normal Depth 21 in
Critical Depth 1.13 ft
Channel Slope 0.20
Critical Slope 0.00357 ft/ft
Bentley Systems,Inc. Haestad Methods SolBbodd)F6rvMaster V81(SELECTseries 1) [08.11.01.03]
4127/2019 7:36:43 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2
Town & Country - 21" PVC Pipe Capacity @ 0.25%
Project Description
Friction Method Manning Formula
Solve For Full Flow Capacity
Input Data
Roughness Coefficient 0.010
Channel Slope 0.25 %
Normal Depth 21 in
Diameter 21 in
Discharge 10.30 ft3/s
Results
Discharge 10.30 ft/s
Normal Depth 21 in
Flow Area 2.41 ft2
Wetted Perimeter 5.50 ft
Hydraulic Radius 5 in
Top Width 0.00 ft
Critical Depth 1.20 ft
Percent Full 100.0
Critical Slope 0.00380 ft/ft
Velocity 4.28 ft/s
Velocity Head 0.28 ft
Specific Energy 2.03 ft
Froude Number 0.00
Maximum Discharge 11.08 ft3/s
Discharge Full 10.30 ft/s
Slope Full 0.00250 ft/ft
Flow Type SubCritical
GVF Input Data
Downstream Depth 0 in
Length 000 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0 in
Profile Description
Profile Headloss 0.00 ft
Average End Depth Over Rise 0.00 %
Bentley Systems,Inc. Haestad Methods SolBikoddprMaster V81(SELECTserles 1) [00.11.01.03]
4127/2019 7:35:29 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 1 of 2
Town & Country - 21" PVC Pipe Capacity @ 0.25%
GVF Output Data
Normal Depth Over Rise 100.00
Downstream Velocity Infinity ft/s
Upstream Velocity Infinity ft/s
Normal Depth 21 in
Critical Depth 1.20 ft
Channel Slope 0.25 %
Critical Slope 0.00380 ft/ft
Bentley Systems,Inc. Haestad Methods SolWhatl rMaster VBI(SELECTseries 1) [08.11.01.03]
4/27/2019 7:35:29 PM 27 Slemons Company Drive Suite 200 W Watertown,CT 06795 USA +1-203-755-1666 Page 2 of 2