Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EOS13ElectricalOffSiteLightingDetails_06152021
S1 AND S2 Inwu M...w.. ..�r.w.°".... ....r .."...•... . . .........w. ........,......_.,e �^'.v""....w..� _ _ �..�.y_" PULLCONCRETE - ,.......q. _ MINIMUM DIMENSIONS •Tanner T. x..�w^a ........+ o TYPE 1 TYPE 2 TYPE 3 x Whluock r.x..........� w....... L = 20" L = 25" L = 32" COVER MUST BE POLYMER W - 13" W - 16" W - 19" CONCRETE WITH FIBERGLASS N,.,�'C> azz_ D = 12" D = 12" D = 12" REINER 22 ENT TRAFFIC �_ _ _ RATED TIER 22 AND BOLTED IDL - 17" IDL - 21" IDL - 28" IDW = 10" IDW = 11" IDW = 15" �..�,..� PZT.., C L = 18" C L = 23" C L = 30" W C W = 11" C W = 13" C W = 17" L f 0 REFER TO CITY OF RE2BOZEMAN NOTE: WHEN REPLACING AN EXISTING .. SPECIFICATIONS FIGURE 2 FOR 0 PULL BOX ADJUST CONDUIT MORE INFORMATION STUB HEIGHT ACCORDINGLY. ,Mc� J_ CDs ENGINEERING ELECTRICAL BOND MCCXxMAN NAI IAN*xMl`Sr9141"'xtt . N0.6 AWG nc cNNNc II N COPPER OR EQUAL IF METAL www.cosi Elx'eixeeeinccoM CONDUIT STUB CONDUIT 4" TO 6" COPPE ELECTRICAL BOND. N0.6 AWG ABOVE BOTTOM OF PULL BOX �2 (-in m n)�3.y CONDUIT R OR EQUAL IF METAL 3" 1 0 0 2•• CONCRETE PAD 0 STUB CONDUIT 4" TO 6" 2V ABOVE BOTTOM OF PULL BOX ®��M „ ,,�,,,,,, �" ,w,r ,.^.�.+� ���,� " CID CONDUIT IN & OUT CONDUIT IN & OUT MINIMUM 2" PVCL MINIMUM 2" PVC MINIMUM 12" 00 1 7 1" CLEAN STONE 00 � 1" CLEAN STONE Si "o'a"' CONCRETE �' �' SUPPORT RING 0 DRAINAGE NO HIGHER 0 DRAINAGE NO HIGHER REFER TO THAN 2" INSIDE THAN 2" INSIDE r� CITY OF BOZEMAN BOTTOM OF PULL BOX BOTTOM OF PULL BOX PULL BOX INSTALLED IN DIRT PULL BOX INSTALLED IN A SIDEWALK OR ASPHALT SPECIFICATIONS FIGURE 3 FOR IS` MORE DETAILS +_ m PULL BOX DETAIL ��� .ft.` �+ w —- . � NO SCALE TB 2021.06.15 RC 1 SITE PLAN REVIEW 5 NO. DATE DESCRIPTION S1 POLE .._,•�.�,,..- ,�,�.--,,,.,.,� ELECTRICAL NOTE: -FT I CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE CITY OF BOZEMAN'S STANDARD SPECIFICATIONS FOR LIGHTING MATERIALS AND INSTALLATION. - PROVIDE AND INSTALL ALL MATERIALS AND EQUIPMENT PER CITY'S vT REQUIREMENTS. 3/4" CHAMFER • Solomon Cordwell Buenz Chicago T 312.896.1100 USE GRADE 60 REINFORCING STEEL TSan 4Francisoo 5218.2450 +�+•y +„�+, - �` # 6 BARS (4'-1" LONG) �ao„onee — Y cpaoon„e (8 TYPICAL) Seattle # 4 HOOPS AT T 206.299.0085 14-0"/18'-0" 1'-O" CENTERS S2 ANCHOR ANCHOR BOLT www.scb.com (4 TYPICAL) ANCHOR BOLT CIRCLE 2-1/2" CLEARANCE — am - GROUNDING LUG SECTION A-A NORTH CENTRAL NO. 6 AWG BARE GROUND WIRE PROTRUDE CONDUIT FROM FOUNDATION BLOCK 4 T_ OR PIGTAIL EXTENSION NOT MORE THAN 3" 4" x 6" REINFORCED HAND HOLE & COVER COPPER GROUNDING STRAP BETWEEN �, w"�r+:!•" ANCHOR BOLT, CONDUIT (IF METAL) & A A 2•_O•• >•.... �,,,,�> =_"^�"'"""" T N0. 6 AWG BARE GROUND WIRE OR "` f PIGTAIL EXTENSION. PROVIDE POLYMER CONCRETE 1'-6' 5' MIN. 8' .L+ PULL/SPLICE BOX ADJACENT TO EACH POLE BREAKAWAY BOLT COUPLINGS � � CLASS GENERAL 6" REFER TO CITY OF BOZEMAN CONCRETE STANDARDS FIGURE 14 FOUNDATION EIGHT #4 HOOPS 4/1 312 0 21 SITE PLAN SUBMITTAL �- NOTE- MAKE THE TOP OF THE CONCRETE • BOZEMAN,MT w,.,S,?r, E -'.-"�" ~��^�'�"""^""'^""""�'^"�• FOUNDATION 2" ABOVE THE GROUND LINE. I'�2' 0'�I L3" ©2020 W....C.—II aw.w. - - -- -- -- �- -- PROVIDE A HANDHOLE DETAIL AND A " ' m GROUND ROD MIN. % NUT HOLDER DETAIL (FOR GROUNDING). TYPICAL OF ALL FOUNDATIONS ELECTRICAL •.:-"--'"- •..-.- '"" �.-•,--+.r.- 5/8" DIA. X 8' LONG BOND TO GROUNDING PVC 3 LIGHT FIXTURE BASE DETAIL _ LUG IN POLE BASE NO SCALE OFF SITE 05.1. LIGHTING DETAILS Drawn By: Checked By: CVD TTW _.._J 2 LIGHT FIXTURE TYPE'S1/S2 POLE DETAIL Project _ OS1• NO SCALE Number: 2020037.000 mceoem -: .,...,�x.� ®COOPER -.�^>r Sheet Number: E O S 1 ■ V