Loading...
HomeMy WebLinkAboutAP2.03TypeBBLDG-FloorPlan-3rdLevel_030320QU E E N KI N G KI N G QU E E N DN DN 3 3 A A C C A3.02 1 A3.01 1 A3.03 2 1 1 2 2 B B SHOWER 301.8 HALL 300.1 DEN 300.2 BEDROOM 300.3 BATH 300.4 MASTER BEDROOM 300.5 W.I.C. 300.6 MASTER BATH 300.7 SHOWER 300.8 C L 6' - 1 " 24' - 0" 24' - 0" HALL 301.1 EE EE FL -5 FL -5 BATH 301.4 W.I.C. 301.6 FL -5 BEDROOM 301.3 MASTER BATH 301.7 MASTER BEDROOM 301.5 DEN 301.2 FL -1 11 ' - 8 1 / 2 " 2' - 3 1 / 2 " 1' - 3 " 5' - 4 1 / 2 " 2' - 1 1 / 2 " 6 1 / 2 " 13 ' - 1 1 1 / 2 " 3' - 10 1/2" 6' - 0 1/2" 4' - 1 1/2" 9' - 11 1/2" 3' - 5 1/2" 4' - 3 1 / 2 " 7' - 8 1 / 2 " 3' - 6 1 / 2 " 6' - 2 1 / 2 " CL 5' - 6 1/2" CL1' - 9 1/2" CL 5' - 6 1/2" CL 2' - 1" C L 5' - 5 1 / 2 " C L 2' - 5 " C L2' - 5 " CL 8' - 1" 48' - 0" 4' - 4" 6' - 0 1/2" 3' - 11 1/2" CL 5' - 6 1/2" 14' - 1" 6' - 0" 3' - 11" 9' - 11" 14' - 1" 13' - 10" 10' - 2" 10' - 5 1/2" 13' - 6 1/2" 6' - 6" 3' - 2" 4' - 3 1 / 2 " 7' - 8 1 / 2 " 3' - 6 1 / 2 " 6' - 2 1 / 2 " CL5' - 6 1/2" CL 1' - 9 1/2" CL 2' - 1" C L 5' - 5 1 / 2 " 11 ' - 8 1 / 2 " 2' - 3 1 / 2 " 1' - 3 " 5' - 4 1 / 2 " 2' - 1 1 / 2 " 6 1 / 2 " 13 ' - 1 1 1 / 2 " 24' - 0" 24' - 0" C L 6' - 1 " 48' - 0" 37 ' - 3 " 37 ' - 3 " 1 D2 D9 D7 D2 D9 D8 FL -5 FL -5 FL -5 FL -2 FL -2 D10 D10 QUEEN CL 8' - 1" D7 D2 D2 D2 D9 FL -5 D8 D9 2 CL8' - 9" CL 8' - 1 1/4" CL8' - 1 1/4" CL 8' - 9" FL -2 AP3.01 1 AP3.02 1 AP3.03 2 C L 6' - 1 0 1 / 2 " C L 6' - 1 0 1 / 2 " SYMBOLS NOTES T WHEN TAGGED ON BUILDING ELEVATION AND PLAN INDICATES TEMPERED SAFETY GLAZING REQUIRED - SEE PLAN AND ELEVATION FOR LOCATIONS WHEN TAGGED ON BUILDING ELEVATION AND PLAN INDICATES FROSTED GLASS PANE - SEE BUILDING ELEVATION AND FLOOR PLAN FOR LOCATIONS WHEN TAGGED ON BUILDING ELEVATION AND PLAN INDICATES EGRESS WINDOW - SEE PLAN AND ELEVATION FOR LOCATIONS F E SHEET PROJECT NUMBER 81211 Gallatin Rd. Suite E Bozeman, Montana 59718 406.587.9968 studiohdesigninc.com PR I N T E D O N : PR O J E C T # : FIL E P A T H : PR O J E C T N A M E : DR A W N B Y : CH E C K E D B Y : TH E S E D R A W I N G S A R E T H E O R I G I N A L UN P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D MA Y N O T B E D U P L I C A T E D O R U S E D W I T H O U T TH E W R I T T E N P E R M I S S I O N O F T H E A R C H I T E C T . REVISIONS ISSUED ISSUE DATE: 3/ 5 / 2 0 2 0 2 : 5 3 : 0 5 P M C: \ U s e r s \ S H D 4 \ D o c u m e n t s \ G r a n C i e l o _ M F _ B l d g 1 1 _ T y p e B_ D R C _ r 2 0 1 9 _ e s c o t t D U N U Y . r v t AP2.03 FLOOR PLAN - 3RD LEVEL GR A N C I E L O M U L T I F A M I L Y BO Z E M A N , M O N T A N A AP 2 . 0 3 GR A N C I E L O M U L T I F A M I L Y Au t h o r Ch e c k e r 03/03/2020 FINAL DRC BU I L D I N G 1 9 / T Y P E B / B L O C K 6 / L O T 5 1/4" = 1'-0" AP2.03 1 FLOOR PLAN - 3RD LEVEL GENERAL NOTES - FLOOR PLANS 1 DIMENSIONS INDICATED ARE TO FACES OF FRAMING AND GRID LINES (TYPICAL), UNLESS NOTED OTHERWISE 2 REFER TO STRUCTURAL, MECHANICAL,PLUMBING, AND ELECTRICAL FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS. ALL NOTES ARE TO BE REVIEWED,AND APPLIED TO RELATED BUILDING COMPONENTS. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE THAT ARE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED OR REASONABLY INFERRED, CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL COLUMN AND BEARING WALL LOCATIONS AND SIZES. 3 REFER TO SHEET A2.00 FOR PARTITION TYPES, DETAILS, AND DESCRIPTIONS. 4 WHERE DOORS IN WOOD STUD/GYPSUM BOARD PARTITIONS ARE NOT SPECIFICALLY LOCATED ON THE PLANS WITH DIMENSION STRINGS, PROVIDE A MINIMUM HINGE-SIDE JAMB DIMENSION OF 6" FROM DOOR OPENING TO ADJACENT PERPENDICULAR WALLS. WHERE DOORS APPEAR TO BE CENTERED WITHIN CORRIDORS, LOCATE THE DOORS IN THE CENTER OF THE CORRIDOR. 5 ALL WALLS CONTAINING A BEDROOM OR BATHROOM MUST BE ACOUSTICALLY INSULATED