HomeMy WebLinkAboutAP2.03TypeBBLDG-FloorPlan-3rdLevel_030320QU
E
E
N
KI
N
G
KI
N
G
QU
E
E
N
DN DN
3
3
A A
C C
A3.02
1
A3.01
1
A3.03
2
1
1
2
2
B B
SHOWER
301.8
HALL
300.1
DEN
300.2
BEDROOM
300.3
BATH
300.4
MASTER
BEDROOM
300.5
W.I.C.
300.6
MASTER
BATH
300.7
SHOWER
300.8
C L
6'
-
1
"
24' - 0" 24' - 0"
HALL
301.1
EE
EE
FL -5
FL -5
BATH
301.4
W.I.C.
301.6
FL -5
BEDROOM
301.3
MASTER
BATH
301.7
MASTER
BEDROOM
301.5
DEN
301.2
FL -1
11
'
-
8
1
/
2
"
2'
-
3
1
/
2
"
1'
-
3
"
5'
-
4
1
/
2
"
2'
-
1
1
/
2
"
6
1
/
2
"
13
'
-
1
1
1
/
2
"
3' - 10 1/2" 6' - 0 1/2" 4' - 1 1/2"
9' - 11 1/2"
3' - 5 1/2"
4'
-
3
1
/
2
"
7'
-
8
1
/
2
"
3'
-
6
1
/
2
"
6'
-
2
1
/
2
"
CL
5' - 6 1/2"
CL1' - 9 1/2"
CL 5' - 6 1/2" CL
2' - 1"
C L
5'
-
5
1
/
2
"
C L
2'
-
5
"
C L2'
-
5
"
CL
8' - 1"
48' - 0"
4' - 4" 6' - 0 1/2" 3' - 11 1/2"
CL
5' - 6 1/2"
14' - 1" 6' - 0" 3' - 11" 9' - 11" 14' - 1"
13' - 10" 10' - 2" 10' - 5 1/2" 13' - 6 1/2"
6' - 6" 3' - 2"
4'
-
3
1
/
2
"
7'
-
8
1
/
2
"
3'
-
6
1
/
2
"
6'
-
2
1
/
2
"
CL5' - 6 1/2"
CL
1' - 9 1/2"
CL 2' - 1"
C L
5'
-
5
1
/
2
"
11
'
-
8
1
/
2
"
2'
-
3
1
/
2
"
1'
-
3
"
5'
-
4
1
/
2
"
2'
-
1
1
/
2
"
6
1
/
2
"
13
'
-
1
1
1
/
2
"
24' - 0" 24' - 0"
C L
6'
-
1
"
48' - 0"
37
'
-
3
"
37
'
-
3
"
1
D2
D9
D7
D2
D9
D8
FL -5
FL -5
FL -5
FL -2
FL -2
D10 D10
QUEEN
CL
8' - 1"
D7
D2
D2
D2
D9
FL -5
D8
D9
2
CL8' - 9"
CL 8' - 1 1/4"
CL8' - 1 1/4"
CL 8' - 9"
FL -2
AP3.01
1
AP3.02
1
AP3.03
2
C L
6'
-
1
0
1
/
2
"
C L
6'
-
1
0
1
/
2
"
SYMBOLS NOTES
T WHEN TAGGED ON BUILDING ELEVATION
AND PLAN INDICATES TEMPERED SAFETY
GLAZING REQUIRED - SEE PLAN AND
ELEVATION FOR LOCATIONS
WHEN TAGGED ON BUILDING ELEVATION
AND PLAN INDICATES FROSTED GLASS
PANE - SEE BUILDING ELEVATION AND
FLOOR PLAN FOR LOCATIONS
WHEN TAGGED ON BUILDING ELEVATION
AND PLAN INDICATES EGRESS WINDOW -
SEE PLAN AND ELEVATION FOR LOCATIONS
F
E
SHEET
PROJECT NUMBER
81211 Gallatin Rd. Suite E
Bozeman, Montana 59718
406.587.9968
studiohdesigninc.com
PR
I
N
T
E
D
O
N
:
PR
O
J
E
C
T
#
:
FIL
E
P
A
T
H
:
PR
O
J
E
C
T
N
A
M
E
:
DR
A
W
N
B
Y
:
CH
E
C
K
E
D
B
Y
:
TH
E
S
E
D
R
A
W
I
N
G
S
A
R
E
T
H
E
O
R
I
G
I
N
A
L
UN
P
U
B
L
I
S
H
E
D
W
O
R
K
O
F
T
H
E
A
R
C
H
I
T
E
C
T
A
N
D
MA
Y
N
O
T
B
E
D
U
P
L
I
C
A
T
E
D
O
R
U
S
E
D
W
I
T
H
O
U
T
TH
E
W
R
I
T
T
E
N
P
E
R
M
I
S
S
I
O
N
O
F
T
H
E
A
R
C
H
I
T
E
C
T
.
REVISIONS
ISSUED
ISSUE DATE:
3/
5
/
2
0
2
0
2
:
5
3
:
0
5
P
M
C:
\
U
s
e
r
s
\
S
H
D
4
\
D
o
c
u
m
e
n
t
s
\
G
r
a
n
C
i
e
l
o
_
M
F
_
B
l
d
g
1
1
_
T
y
p
e
B_
D
R
C
_
r
2
0
1
9
_
e
s
c
o
t
t
D
U
N
U
Y
.
r
v
t
AP2.03
FLOOR PLAN -
3RD LEVEL
GR
A
N
C
I
E
L
O
M
U
L
T
I
F
A
M
I
L
Y
BO
Z
E
M
A
N
,
M
O
N
T
A
N
A
AP
2
.
0
3
GR
A
N
C
I
E
L
O
M
U
L
T
I
F
A
M
I
L
Y
Au
t
h
o
r
Ch
e
c
k
e
r
03/03/2020 FINAL DRC
BU
I
L
D
I
N
G
1
9
/
T
Y
P
E
B
/
B
L
O
C
K
6
/
L
O
T
5
1/4" = 1'-0" AP2.03
1 FLOOR PLAN - 3RD LEVEL
GENERAL NOTES - FLOOR PLANS
1 DIMENSIONS INDICATED ARE TO FACES OF
FRAMING AND GRID LINES (TYPICAL), UNLESS
NOTED OTHERWISE
2 REFER TO STRUCTURAL,
MECHANICAL,PLUMBING, AND ELECTRICAL FOR
ADDITIONAL GENERAL NOTES, ABBREVIATIONS,
AND SYMBOLS. ALL NOTES ARE TO BE
REVIEWED,AND APPLIED TO RELATED BUILDING
COMPONENTS. DETAILS NOT SHOWN ARE
SIMILAR IN CHARACTER TO THOSE THAT ARE
SHOWN. WHERE SPECIFIC DIMENSIONS,
DETAILS, OR DESIGN INTENT CANNOT BE
DETERMINED OR REASONABLY INFERRED,
CONSULT THE ARCHITECT BEFORE PROCEEDING
WITH THE WORK. REFER TO STRUCTURAL
DRAWINGS FOR STRUCTURAL COLUMN AND
BEARING WALL LOCATIONS AND SIZES.
3 REFER TO SHEET A2.00 FOR PARTITION TYPES,
DETAILS, AND DESCRIPTIONS.
4 WHERE DOORS IN WOOD STUD/GYPSUM BOARD
PARTITIONS ARE NOT SPECIFICALLY LOCATED
ON THE PLANS WITH DIMENSION STRINGS,
PROVIDE A MINIMUM HINGE-SIDE JAMB
DIMENSION OF 6" FROM DOOR OPENING TO
ADJACENT PERPENDICULAR WALLS. WHERE
DOORS APPEAR TO BE CENTERED WITHIN
CORRIDORS, LOCATE THE DOORS IN THE
CENTER OF THE CORRIDOR.
5 ALL WALLS CONTAINING A BEDROOM OR
BATHROOM MUST BE ACOUSTICALLY INSULATED