Loading...
HomeMy WebLinkAboutAP2.03TypeABLDG-FloorPlan-3rdLevel_030320QU E E N QU E E N QU E E N KI N G KI N G KI N G 4 4 C C A3.03 1 A3.02 1 A3.01 1 A3.03 2 1 1 2 2 3 3 B B A A SHOWER 302.8 SHOWER 301.8 HALL 300.1 DEN 300.2 BEDROOM 300.3 BATH 300.4 MASTER BEDROOM 300.5 W.I.C. 300.6 MASTER BATH 300.7 SHOWER 300.8 C L 6' - 1 0 1 / 2 " 24' - 0" 24' - 0" 24' - 0" 13' - 7 3/4" 2' - 5" 7' - 11 1/4" 13' - 8" 10' - 4" 9' - 10 1/2" 14' - 1 1/2" HALL 301.1 HALL 302.1 EEE EE BATH 301.4 W.I.C. 301.6 BEDROOM 301.3 MASTER BATH 301.7 MASTER BEDROOM 301.5 DEN 301.2 DEN 302.2 BEDROOM 302.3 BATH 302.4 MASTER BATH 302.7 MASTER BEDROOM 302.5 W.I.C. 302.6 13' - 6 3/4" 10' - 5 1/4" 13' - 7" 10' - 5" 11 ' - 8 1 / 2 " 2' - 3 1 / 2 " 1' - 3 " 5' - 4 1 / 2 " 2' - 1 1 / 2 " 6 1 / 2 " 13 ' - 1 1 1 / 2 " 11 ' - 8 1 / 2 " 2' - 3 1 / 2 " 1' - 3 " 5' - 4 1 / 2 " 2' - 1 1 / 2 " 6 1 / 2 " 13 ' - 1 1 1 / 2 " 4' - 3 1 / 2 " 7' - 8 1 / 2 " 3' - 6 1 / 2 " 6' - 2 1 / 2 " 3' - 6" 6' - 6" 4' - 1 1/2" 6' - 0 1/2" 3' - 10" 4' - 3 1/2" 6' - 0 1/2" 3' - 11 1/2" 6' - 6" 3' - 2 1/2" 4' - 3 3/4" 6' - 0 1/2" 3' - 11 1/2" 6' - 6" 3' - 2 1/4" C L 4' - 1 1 1 / 4 " CL 1' - 9 1/2" CL 5' - 6 1/2" DN DN DN C L C L 9' - 4 " 2' - 4 " 24' - 0" 24' - 0" 24' - 0" 72' - 0" 72' - 0" CL 8' - 2" CL 5' - 6 1/2" CL 1' - 9 1/2" C L C L 9' - 4 " 2' - 4 " 4' - 3 1 / 2 " 7' - 8 1 / 2 " 3' - 6 1 / 2 " 6' - 2 1 / 2 " 3' - 0 " E CL 8' - 9" CL8' - 1 1/4" CL 8' - 1 1/4" CL8' - 9" CL 5' - 3 1/2" CL6' - 9 1/4" C L 6' - 1 " C L 6' - 1 " C L 6' - 1 0 1 / 2 " CL 8' - 1" CL 8' - 1" CL 5' - 6 1/2" 4' - 3 1 / 2 " 7' - 8 1 / 2 " 3' - 6 1 / 2 " AP3.01 1 AP3.02 1 AP3.03 1 AP3.03 2 37 ' - 3 " 37 ' - 3 " SYMBOLS NOTES T WHEN TAGGED ON BUILDING ELEVATION AND PLAN INDICATES TEMPERED SAFETY GLAZING REQUIRED - SEE PLAN AND ELEVATION FOR LOCATIONS WHEN TAGGED ON BUILDING ELEVATION AND PLAN INDICATES FROSTED GLASS PANE - SEE BUILDING ELEVATION AND FLOOR PLAN FOR LOCATIONS WHEN TAGGED ON BUILDING ELEVATION AND PLAN INDICATES EGRESS WINDOW - SEE PLAN AND ELEVATION FOR LOCATIONS F E SHEET PROJECT NUMBER 81211 Gallatin Rd. Suite E Bozeman, Montana 59718 406.587.9968 studiohdesigninc.com PR I N T E D O N : PR O J E C T # : FIL E P A T H : PR O J E C T N A M E : DR A W N B Y : CH E C K E D B Y : TH E S E D R A W I N G S A R E T H E O R I G I N A L UN P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D MA Y N O T B E D U P L I C A T E D O R U S E D W I T H O U T TH E W R I T T E N P E R M I S S I O N O F T H E A R C H I T E C T . REVISIONS ISSUED ISSUE DATE: 3/ 9 / 2 0 2 0 1 1 : 4 9 : 4 7 A M C: \ U s e r s \ S H D 4 \ D o c u m e n t s \ G r a n C i e l o _ M F _ B l d g 3 _ T y p e A _r 2 0 1 9 _ e s c o t t D U N U Y . r v t AP2.03 FLOOR PLAN - 3RD LEVEL GR A N C I E L O M U L T I F A M I L Y BO Z E M A N , M O N T A N A 5 9 7 1 8 AP 2 . 0 3 GR A N C I E L O M U L T I F A M I L Y Au t h o r Ch e c k e r 03/03/2020 FINAL DRC BU I L D I N G 2 1 / T Y P E A / B L O C K 6 / L O T 5 1/4" = 1'-0" AP2.03 1 FLOOR PLAN - 3RD LEVEL UNIT HEATED AREA 101 863 SF 102 833 SF 103 833 SF CONDITIONED AREA - 3RD LEVEL 6055 SF 2756 SF TOTAL CONDITIONED AREA OF LEVEL GRAND TOTAL CONDITIONED AREA BUILDING FOOTPRINT 2529 SF