HomeMy WebLinkAbout21175 Staff Report Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 1 of 13
Application No. 21175 Type Site Plan
Project Name Fallon Condos
Summary A site plan application for 22 residential units constructed as 18 buildings with 5 different
building designs with associated drive access, open space, landscaping, and site
improvements in Norton Ranch Subdivision Phase 4.
Zoning REMU Growth Policy Community Commercial
Mixed Use
Parcel Size 2.09 Acres
Overlay District(s) None
Street Address 5108-5184 Fallon Street
Legal Description Lot 1A, Amended Plat of Lot 1 and Lot 2, Block 14, Norton East Ranch Subdivision Phase 4,
Located in the SE ¼ of Sec. 9, T. 2 S., R. 5. E., of P.M.M., City of Bozeman, Gallatin County,
Montana
Owner Norton Ranch Properties, LLC, 63029 NE Lower Meadow Dr. #200, Bend, OR 97701-5877
Applicant Same as Owner
Representative Intrinsik Architecture, 111 N. Tracy Ave., Bozeman, MT 59715
Staff Planner Danielle Garber Engineer Mikaela Schultz
Noticing Public Comment Period Site Posted Adjacent Owners
Mailed
Newspaper Legal Ad
8/25/21 – 9/9/21
8/25/21 8/25/21 N/A
Advisory Boards Board Date Recommendation
Development Review
Committee
9/8/21 The application is adequate, conforms to
standards, and is sufficient for approval with
conditions and code provisions
Design Review Board NA NA
Recommendation The application is adequate, conforms to standards, and is sufficient for approval with conditions and
code provisions as noted below.
Decision Authority Director of Community Development Date 9/23/21
Full application and file of record: Community Development Department, 20 E. Olive St., Bozeman, MT 59715
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 2 of 13
FINDINGS OF FACT AND APPEAL PROVISIONS CERTIFICATE
A) PURSUANT to Chapter 38, Article 2, Bozeman Municipal Code (BMC), and other applicable sections of Ch.38, BMC, public
notice was given, opportunity to submit comment was provided to affected parties, and a review of the Site Plan described in
this report was conducted. The applicant proposed to the City a Site Plan (SP) to permit 22 residential units constructed as 18
buildings with 5 different building designs with associated drive access, open space, landscaping, and site improvements. The
purposes of the Site Plan review were to consider all relevant evidence relating to public health, safety, welfare, and the other
purposes of Ch. 38, BMC; to evaluate the proposal against the criteria of Sec. 38.230.100 BMC, and the standards of Ch. 38,
BMC; and to determine whether the application should be approved, conditionally approved, or denied.
B) It appeared to the Director that all parties and the public wishing to examine the proposed Site Plan and offer comment were
provided the opportunity to do so. After receiving the recommendation of the relevant advisory bodies established by Ch. 38,
Art. 210, BMC, and considering all matters of record presented with the application and during the public comment period
defined by Ch. 38, BMC, the Director has found that the proposed Site Plan would comply with the requirements of the BMC if
certain conditions were imposed. Therefore, being fully advised of all matters having come before them regarding this
application, the Director makes the following decision.
C) The Site Plan has been found to meet the criteria of Ch. 38, BMC, and is therefore approved, subject to the conditions listed
in this report and the correction of any elements not in conformance with the standards of the Title. The evidence contained in
the submittal materials, advisory body review, public testimony, and this report, justifies the conditions imposed on this
development to ensure that the Site Plan complies with all applicable regulations, and all applicable criteria of Ch. 38, BMC.
On this ______ day of ________________, 2021, Martin Matsen, Director of Community Development, approved with
conditions this Site Plan for and on behalf of the City of Bozeman as authorized by Sec. 38.200.010, BMC.
D) This Director of Community Development’s project decision may be appealed by filing a documented appeal with and paying
an appeal fee to the Clerk of the Commission for the City of Bozeman within 10 working days after the date of the final decision
as evidenced by the Director’s signature, following the procedures of Sec. 38.250.030, BMC.
DIRECTOR OF COMMUNITY DEVELOPMENT
CONDITIONS OF APPROVAL
1. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions
of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman
Municipal Code or state law.
2. If not already on file, the applicant must provide and file with the County Clerk and Recorder an executed SID
waiver prior to final site plan approval as detailed in engineering comments.
3. Cash-in-lieu of Water rights assessment and payment (if applicable) is required prior to final site plan approval.
4. Cash-in-lieu of Parkland approval and payment is required prior to final site plan approval. Please coordinate with
Matthew Lee, mjlee@bozeman.net.
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 3 of 13
CODE PROVISIONS
1. BMC 38.410.070- PHASE (4) - The proposed project is located within the service area of the Norton Ranch Lift
Station. The Station has been designed to be reconfigured to allow for phased development of the Norton Ranch
Subdivision. The exact configuration is dependent on the phase and number of dwelling units to be served.
Currently, there is an approved set of plans to upgrade the lift station to serve the subject property, referred to as
NRLS Phase 1 Upgrades. The proposed development may not exceed the lift station capacity designed for the
subject property unless additional upgrades beyond the NRLS Phase 1 Upgrades are completed. The applicant
must demonstrate that the peak-hour wastewater flow from the proposed project is equal to or less than the
design capacity reserved for the parcels in the subdivision’s wastewater design report.
a. If the development’s peak-hour wastewater flow is equal to or less than the design capacity reserved for
the parcels, Site Plan approval may be granted but occupancy will not be granted until the NRLS Phase 1
Upgrades are complete.
b. If the development’s peak-hour wastewater flow exceeds the design capacity reserved for the parcels,
additional upgrades to the lift station must be completed prior to building permits approval.
2. BMC 38.410.060 - The applicant provided a Sewer and Water Pipeline and Access Easement draft that is adequate.
An executed hard copy of this easement must be delivered to the review engineer for final review and recording with
the county clerk prior to site plan approval.
3. BMC 38.410.060 - The applicant must submit a city standard Public Access easement draft and Utility easement
draft for review. Executed hard copies of all above noted easements must be delivered to the review engineer for
final review and recording with the county clerk prior to site plan approval.
4. DSSP Section (D) (5) Easements - No permanent structures shall be placed within a utility easement unless an
encroachment permit has been obtained. Trees or other significant landscaping features shall not be placed within
ten (10) feet of any utility main or service lines. Storm Swales 2 and 3 are within ten feet of the water and sewer
mains, the applicant must move the swales out of the 30’ public utility easement or file an encroachment permit with
the City prior to final site plan approval.
5. BMC 38.270.030 C.1. – Prior to site plan approval, concurrent construction must be approved for the public
infrastructure associated with the project (water mains and sewer mains).
ENGINEERING ADVISORY COMMENT:
1. BMC 38.410.080/DSSP (2)(B)(3)
a. There is a grate rim elevation missing from the grading drawing for Drywell #2. The applicant should
include an elevation for this grate on the project drawings.
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 4 of 13
Figure 1: Current Zoning Map
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 5 of 13
Figure 2: Proposed Site Plan
Figure 3: Landscape Plan
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 6 of 13
Figure 4: Phasing Plan
Figure 5: Parking Plan – Off-street indicated in blue, stacked parking indicated in green, on-street in red
boxes
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 7 of 13
Figure 4: Front Elevations - The Boulder (East Units, Left), Calderwood (North Units, Right)
Figure 5: Exterior Elevations – Greenhorn (South Units, Left), Highland (West Units, Right)
Figure 6: Exterior Elevations – Rowhouse Units
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 8 of 13
ANALYSIS AND FINDINGS
Analysis and resulting recommendations based on the entirety of the application materials, municipal codes, standards,
plans, public comment, and all other materials available during the review period. Collectively this information is the record
of the review. The analysis in this report is a summary of the completed review.
Plan Review, Section 38.230.100, BMC
In considering applications for plan approval under this title, the Director of Community Development shall consider the
following:
1. Conformance with Article 1 - Consistency with the City’s adopted Growth
Policy 38.100.040.D
Meets Code?
Growth Policy
Land Use
Community Commercial Mixed Use Yes
Zoning REMU, Residential Emphasis Mixed Use Yes
Comments: The project conforms to the requirements of the REMU zoning district. The 2020 Community Plan designation
of Community Commercial Mixed use correlates with the REMU zoning district. The proposed project conforms to this
designation by providing housing diversity and missing-middle housing in accordance the REMU zoning provisions.
2. Conformance with Article 1 - All other applicable laws, ordinances, and
regulations (38.100.080)
Condominium ownership No
Comments: Additional steps will be required including but not limited to review of building permits and
infrastructure plans. The Building Division of the Department of Community Development will review the
requirements of the International Building Code for compliance at the time of building permit application.
3. Conformance with Article 2, including the cessation of any current violations
(38.200.160)
Meets Code?
Current Violations None Yes
Comments: There are no current violations on the property.
4. Conformance with Article 2 - Submittal material (38.220) requirements and
plan review for applicable permit types (38.230)
Meets Code?
Site Plan Yes
Submittal requirements 38.220.100 Yes
Phasing of development
38.230.020.B
No. of phases: 4 Yes
Comments: The overall site plan details improvements in phases four phases. Phase 1 includes the east
buildings and interior drive aisles and utilities, as well as the pedestrian and utility access along the south
property line. Phase 2 includes the north buildings and adjacent walkways, parking, and open space.
Phase 3 includes the west buildings and adjacent walkways and parking. Phase 4 includes the south
buildings and adjacent drive accesses and open space.
Any additional use permit (Conditional Use Permit) 38.230.120 or (Special use
Permit) 38.230.120
NA
Comments: No conditional or special uses are proposed.
5. Conformance with Article 3 - Zoning Provisions (38.300) Meets Code?
Permitted uses 38.310 1-4 Household, Rowhouses Yes
Form and intensity standards 38.320
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 9 of 13
Zoning: REMU Setbacks
(feet)
Structures Parking / Loading Yes
Front 10-15 & Block
Frontage
NA
Rear 10 NA
Side 5 NA
Alley NA NA
Comments: Single household dwellings and rowhouses with 5 or fewer attached units are primary uses
within the REMU zoning district. The proposed project sits on the corners of Fallon Street and Pond Lily
Drive and Fallon and Water Lily Drive; both front setbacks are met with the proposed design. The rear
setback of 15-feet is met along the south property line. No side setbacks are present; a subdivision
exemption application to aggregate the two underlying lots was approved and is recorded under plat J-
668A.
Lot
coverage
47% Allowed 50-75% Yes
Building
height
Varies, see
comments.
Allowed 35-42 Feet
depending on
building form and
roof type
Yes
Comments: Building heights for the single household structures ranges from 24-feet to 28-feet, with varying
roof pitches of 8:12 and 10:12. Maximum heights for single household structures in REMU at these roof pitches
varies from 40 to 42-feet. The two rowhouse buildings propose a 1:12 roof pitch, with a max height of 23’ 10”
meeting the height standard at less than 3:12 of 35’ maximum.
Applicable zone specific or overlay standards 38.330-40 Yes
Comments: There are zone specific standards for the REMU district. Applicable standards from this
section are listed below:
- Street and circulation standards – Buildings are oriented with the front facades facing the street.
Shared drive accesses and on-street parking is proposed as required in this section when
feasible. Front loaded local streets with no parking in front setbacks and pedestrian connections
through the site are proposed.
- Site planning and design elements from 38.520, and 38.360.220 – The proposed design is
meeting the requirements of these sections. See below for additional discussion.
- Open space standards – The single household dwellings do not trigger additional open space
requirements. The rowhouse buildings are providing open space according to section 38.360.
See below for additional discussion.
- Building standards – Meeting rowhouse design standards in 38.360. Single household structures
are not subject to building design standards.
General land use standards and requirements 38.350 NA
Comments: NA
Applicable supplemental use criteria 38.360 Yes
Supplemental
uses/type
Single, two, three, and four-household dwellings &
Townhouse/Rowhouse Standards
Yes
Comments: The proposed application is providing clear and obvious pedestrian connections to all units
between the sidewalk and the building entries that face the street. All dwellings are providing weather
protection for the pedestrian entry meeting or exceed the 3’ x 3’ standard. Applicable rowhouse standards
from this section are listed below:
- Internal drive aisle standards – Meeting the minimum 24-foot width.
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 10 of 13
- Usable open space – The two rowhouse buildings are providing open space directly adjacent to
each units meeting the minimum 12-foot dimensions. These open space areas contain patio and
seating areas, and are accessed from within the units with fencing for privacy. .
- Building design – Repetition with variety is provided by reversing one of the three attached units.
Façade articulation is provided with the use of entries, windows, and roofline.
Wireless facilities 38.370 NA
Affordable Housing 38.380.010 NA
Affordable housing plan NA
Comments: No wireless facilities are proposed. No affordable housing requirements are triggered with
the proposed uses.
6a. Conformance with Article 4 - Community Design Provisions: Transportation
Facilities and Access (38.400)
Meets Code?
Streets 38.400.010 Yes
Street and road dedication 38.400.020 NA
Access easements Yes
Level of Service
38.400.060
Yes Transportation grid adequate to serve site Yes
Comments: Adjacent streets exist to serve the site, no additional dedication is needed. No new traffic
impact study was required by the Engineering Division however, a peak-hour trip generation letter was
provided by the Applicant to ensure that the proposed project would not exceed the original assumed trip
estimates reviewed with the subdivision. Level of service standards for arterial and collector streets
serving the site was evaluated by engineering. A Waiver of Right to Protest Creation of Special
Improvement Districts (SID’s) for future transportation improvements is a required condition of approval
ensuring participation in funding of future infrastructure improvements that may be required to offset
impacts created by development of the property.
Sidewalks 38.400.080 Yes
Comments: Sidewalks are to be provided along the primary street frontages and through the south end of
the site.
Drive access 38.400.090 Access to site: 2 Yes
Fire lanes, curbs, signage and striping Yes
Comments: Two drive accesses are proposed along Fallon Street; engineering evaluated both drive
accesses for spacing and design standards.
Street vision triangle 38.400.100 Yes
Transportation pathways 38.400.110 Yes
Pedestrian access easements for shared use pathways and similar transportation
facilities
Yes
Public transportation 38.400.120 NA
Comments: Two 30-foot public access and utility easements are proposed within the site and required to
be provided prior to final site plan approval, see code corrections.
6b. Conformance with Article 4 – Community Design Provisions: Community
Design and Elements (38.410)
Meets Code?
Neighborhood centers 38.410.020 NA
Comments: This project does not trigger neighborhood center requirements.
Lot and block standards 38.410.030-040 NA
Midblock crossing: rights of way for pedestrians alternative block delineation NA
Comments: This project does not trigger lot and block standards.
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 11 of 13
If the development is adjacent to an existing or approved public park or public open
space area, have provisions been made in the plan to avoid interfering with public
access to and use of that area
NA
Provisions for utilities including efficient public services and utilities 38.410.050-060 Yes
Easements (City and public utility rights-of-way etc.) Yes
Water, sewer, and stormwater Yes
Other utilities (electric, natural gas, communications) Yes
CIL of water Yes
Comments: Requirements were reviewed by engineering. A CIL water rights credits is available for this
parcel. The applicant has not indicated the intention to use the credit or pay CIL. See conditions of approval.
Municipal infrastructure requirements 38.410.070 Yes
Comments: Municipal water, sanitary sewer, and storm sewer systems proposed with this project have
been reviewed by engineering.
Grading & drainage 38.410.080 Yes
Location, design and capacity of stormwater facilities Yes
Stormwater maintenance plan Yes
Landscaping: native species, curvilinear, 75% live vegetation 38.410.080.H Yes
Comments: Location, design and capacity of stormwater facilities was reviewed by engineering. A swale is
proposed along the south property line and is proposed to be landscaped according to depth and grade.
Watercourse setback 38.410.100 NA
Watercourse setback planting plan 38.410.100.2.f NA
6c. Conformance with Article 4 – Community Design Provisions: Park and
Recreation Requirements (38.420)
Meets Code?
Parkland requirements 38.420.020.A 0.15 ac. CIL required Yes
Cash donation in lieu (CIL) 38.420.030 Yes
Improvements in-lieu NA
Comments: 0.15 acres = 43,560 sf x 1.72psf = $11,238.48 required cash in lieu. Condition of approval 4
requires this amount be approved and paid prior to final site plan approval.
Park Frontage 38.420.060 NA
Park development 38.420.080 NA
Recreation pathways 38.420.110 NA
Park/Recreational area design NA
Comments: No parks are proposed with this application. Public parks exist to the east and north within
the Norton Ranch Subdivision that can be accessed via sidewalk and planned pedestrian paths.
7a. Conformance with Article 5 – Project Design: Block Frontage Standards
(38.510)
Meets Code?
Block frontage classification Mixed – Landscaped NA
Departure criteria None requested Yes
Comments: Single to four household dwellings in any configuration are not subject to block frontage
standards.
7b. Conformance with Article 5 – Project Design: Site Planning and Design
Elements (38.520)
Meets Code?
Design and arrangement of the elements of the plan (e.g., buildings, circulation, open
space and landscaping, etc.) so that activities are integrated with the organizational
Yes
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 12 of 13
7d. Conformance with Article 5 – Parking (38.540) Meets Code?
Parking requirements 38.540.050 Yes Yes
Parking requirements residential 38.540.050.A.1 53 spaces
Reductions residential 38.540.050.A.1.b 18 on-street
Parking requirements nonresidential
38.540.050.A.2
NA
Reductions nonresidential 38.540.050.A.2.c NA
Provided off-street 41
Provided on-street 10
Bicycle parking 38.540.050.A.4 In unit
Comments: This project proposes 13 two-bedroom units, and 9 three-bedroom units with a total of 53
parking spaces required. Parking is proposed within garages and carports, with 3 of the carport units
providing room for stacked parking. Each stall provided off-street meets the stall, aisle, and driveway
scheme of the community, neighborhood, and other approved development and produce
an efficient, functionally organized and cohesive development
Relationship to adjacent properties 38.520.030 NA
Non-motorized circulation and design systems to enhance convenience and safety
across parking lots and streets, including, but not limited to paving patterns, pathway
design, landscaping and lighting 38.420.040
Yes
Comments: A north-south pedestrian path through the site is proposed within the 30-foot access
easement. An east-west pedestrian path through the site is proposed within the other 30-foot access
easement with stamped concrete crosswalks. All units have a direct front door connection to a sidewalk.
Design of vehicular circulation systems to assure that vehicles can move safely and
easily both within the site and between properties and activities within the general
community 38.420.050
Yes
Internal roadway design 38.520.050.D NA
Comments: NA
On-site open space 38.520.060
Total required 979 square feet Yes
Total provided 1,026 square feet Yes
Comments: Only the two rowhouse buildings trigger open space requirements from townhouse/rowhouse
standards in Article 3. Private patios with low privacy fencing are provided for each unit, with a 5-foot
screen wall between units when open space areas are adjacent.
Location and design of service areas and mechanical equipment 38.520.070 Yes
Comments: No mechanical equipment is proposed for the single detached units. The rowhouse units
have A/C units within roof chases. Utility meters are to be screened by landscaping. Solid waste will be
collected via individual totes.
7c. Conformance with Article 5 – Project Design: Building Design (38.530) Meets Code?
Compatibility with, and sensitivity to, the immediate environment of the site and the
adjacent neighborhoods and other approved development 38.530.030
Yes
Building massing and articulation 38.530.040 Yes – TH/RH
Requirements
Building details, materials, and blank wall treatments 38.530.050-070 NA
Comments: The two rowhouse buildings are meeting the building design standards of this section as
required by townhouse/rowhouse standards in Article 3. Changes in roofline, materials, and windows are
used for articulation. One unit out of three is reversed per the article 3 standards, with additional building
material changes to create variety with repetition.
Staff Report
Fallon Condos Site Plan
Application No. 21175
September 23, 2021
Page 13 of 13
design requirements of Section 38.540.020. On-street parking provides a residential reduction of 18
spaces. Bike parking will be provided within each unit.
Loading and uploading area requirements 38.540.080 NA
First berth – minimum 70 feet length, 12 feet in width, 14 feet in height NA
Additional berth – minimum 45 feet length NA
Comments: NA
7e. Conformance with Article 5 – Landscaping (38.550) Meets Code?
Mandatory landscaping requirements 38.550.050 Yes
Drought tolerant species 75% required Yes
Parking lot landscaping NA
Additional screening NA
Street frontage Yes
Street median island NA
Acceptable landscape materials Yes
Protection of landscape areas NA
Irrigation: plan, water source, system type Yes
Residential adjacency NA
Comments: The provided landscaping plan conforms to standards.
Landscaping of public lands 38.550.070 Yes
Comments: Street trees will be provided along the three street frontages.
7f. Conformance with Article 5 – Signs (38.560) Meets Code?
Allowed SF/building 38.560.060 NA NA
Proposed SF/building NA NA
Comments: NA
7g. Conformance with Article 5 – Lighting (38.560) Meets Code?
Site lighting (supports, cutoff, footcandles, temperature) 38.570.040 NA
Building-mounted lighting (supports, cutoff, footcandles, temperature) 38.570.040.B Yes
Comments: No site lighting is proposed.
8. Conformance with Article 6 – Natural Resource Protection Meets Code?
Floodplain regulations 38.600 NA
Wetland regulations 38.610 NA
Comments: NA
9. Relevant Comment from Affected Parties (38.220) Meets Code?
Public Comment Yes
Comments: A public notice period was conducted meeting the requirements of this section and detailed on
page 1 of this report. No public comment was received.
10. Division of Land Pertaining to Subdivisions (38.240-Part 4) Meets Code?
Subdivision exemptions Yes
Required easements Yes
Comments: A subdivision application to aggregate the two underlying lots was recorded under document
#2744388 and plat J-668A. See conditions of approval and code provisions for remaining access and
utility easement work.