HomeMy WebLinkAboutL2.4IrrigationDtls_08-25-21PIPE BENEATH PAVEMENT1 1/2" = 1'-0"Pavement.Base rock.3'-0"Notes:1- See irrigation legend for mainline size and type.2- All sleeves shall be Sch. 40 PVC pipe.3- All sleeves shall extend 12" beyond the edge of pavement.4- End of sleeves shall be located with a wooden stake or PVC pipe. Locators shall run continuously from the end of the sleeve to finished grade.Clean backfill, 95% relative compaction underpaving or per civil engineer's plans.Control wires, sleeve under paving. Installadjacent to pressurized mainline. Bundleshall be no more than 50% of pipe diameter.Mainline, sleeve under paving to be two timesthe diameter of the pressurized mainline pipe.Non-pressurized line, sleeve under paving to betwo times the diameter of the lateral line.URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USEFX-IR-FX-AUXEQ-05MINIMUM BEARING SURFACE AREAPIPE SIZETEE AND PLUG90° BEND45° BEND1-1/2"0.45 FEET ²0.63 FEET ²0.34 FEET ²2"0.69 FEET ²2-1/2"1.0 FEET ²3"1.48 FEET ²4"2.43 FEET ²6"5.25 FEET ²8"9.08 FEET ²10"14.93 FEET ²0.97 FEET ²1.41 FEET ²2.10 FEET ²3.45 FEET ²7.41 FEET ²12.83 FEET ²21.07 FEET ²0.53 FEET ²0.77 FEET ²1.14 FEET ²1.87 FEET ²4.02 FEET ²6.96 FEET ²11.44 FEET ²THRUST BLOCK1 1/2" = 1'-0"Notes:1- Size thrust blocks shall be specified as show in the table above. Thrust blocks required for PVC Mainline pipe 2-1/2" or larger.2- Control wires shall not be encased in concrete.3- All fittings shall be wrapped with polyethylene to prevent concrete from adhering to pipe, fittings or bolts.4- Joints and bolts shall be accessible for repairs.5- Thrust blocks shall be a minimum of 6" thick.6- One 80 lbs. sack of concrete shall cover .6 ft.³Bearing surface.Bearing surface.Existing or modified soil. (See specifications forsoil modification).URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USEFX-IR-FX-AUXEQ-07NOTES:1- See irrigation legend for mainline and lateral line pipe size and type.2- Direct burial control wires shall be installed in Sch. 40 PVC electrical conduit if required.3- 2-wire irrigation wire shall be installed in Sch. 40 PVC electrical conduit.4- Detectable locator tape shall be located six inches (6") above the entire mainline run.Direct burial low voltagecontrol wires.Pavement.IRRIGATION TRENCHING1 1/2" = 1'-0"24" min.1'-0" In planting area 1'-6" in planting area 3'-0" underneath pavement Non-pressurized line (lateral line).Detectable locator tape.Pressurized line (mainline).6"Finished grade.URBAN TREE FOUNDATION © 2014OPEN SOURCE FREE TO USEFX-IR-FX-AUXEQ-08SLEEVE AT ROAD1 1/2" = 1'-0"FX-IR-FX-AUXEQ-15PGV GLOBE VALVE1" = 1'-0"18-24" COILED WIREWATERPROOF CONNECTORS (2)FINISH GRADEREMOTE CONTROL VALVEMODEL PGV-XXXGSTANDARD VALVE BOXSCH 80 T.O.E. NIPPLEMAIN LINE PIPE & FITTINGSBRICK SUPPORTS (4)3/4" MINUS WASHED GRAVELFX-IR-HUNT-VALV-11SHEET No:JOB No:DATE:REVISIONS:LANDSCAPE ARCHITECTURE& LAND PLANNING109 E Oak St, Ste 1FBozeman, MT(406) 624-9111info@inContour.com ZZZ.inContour.comPREPARED FOR:inContour08/25/2021Bozeman, MT Bozeman Cohousing21150WGM Group109 E Main St. Suite B Bozeman, MT 59715(406) 728-4611WGMGROUPWWW.WGMGROUP.COM S TA T E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D 123434241NOTES:1.CONTROLLER ACCEPTS 120 VOLTS A.C. OR 230 VOLTS A.C. (INTERNATIONAL MODEL).2.MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL, CONTROLLER SHALL BE HARD-WIRED TO GROUNDED 110 VACPOWER SOURCE.3.REFER TO THE HUNTER HCC INSTALLATION GUIDE FOR FURTHER INSTRUCTIONS.IRRIGATION CONTROLLER (HCC-800-PL) PER PLANIRRIGATION CONTROL WIRE IN CONDUIT -SIZE AND TYPE PER LOCAL CODESELECTRICAL SUPPLY CONDUIT - CONNECT TO POWER SOURCE, J-BOX INSIDE CONTROLLERADJACENT SURFACE TO MOUNT CONTROLLER PER PLAN5" WIDTH[13 cm]13.7" [35 cm]OPEN DOOR WIDTHFRONT ELEVATIONSIDE ELEVATION13.7" [35 cm]12" [30 cmWALL MOUNT IRRIGATION CONTROLLERDETAIL LEGENDL2.4IRRIGATION DETAILS