HomeMy WebLinkAboutA3.5BldgsFloor&RoofPlanBldgXI_08-25-212:122:122:122:122:122:1203485' - 6"1' - 6"1' - 6"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 6"1' - 6"1' - 6"1' - 6"1' - 6"1' - 0"92:122:122:122:122:121A5.6A4.54A4.52A4.53525 SF2-CAR GARAGE: CType564 SF2-CAR GARAGE: TType2-CAR GARAGE: T Type2-CAR GARAGE: T Type2-CAR GARAGE: T Type2-CAR GARAGE: T Type40' - 0"138' - 6"23' - 6"23' - 6"23' - 6"23' - 6"23' - 6"21' - 0"3' - 0"3' - 0"3' - 0"3' - 0"3' - 0"4' - 3"A4.5112111111111124' - 0"3' - 0"3' - 0"3' - 0"3' - 0"4' - 0"1A5.6A9.0324' - 6"Sheet Title:DateDrawn ByProject NumberM.B & E.BBYREVISIONSArchitect:STUDIO CO+HAB, LLC914 W Babcock StBOZEMAN, MT 59715651.336.0394erik@studiocohab.com8/25/2021 4:47:18 PMA3.5Buidings floor & roofplan Building XIBozemanCohousingBozeman Coho, LLC8/25/20211904BOZ3120 Wagonwheel Rd.Bozeman, MT, 59715Formal Site Plan - 3rd SubmittalFormal Site Plan -3rd Submittal1/8" = 1'-0"2Building XI (Garages) - Roof Plan1/8" = 1'-0"1Building XI (Garages) - PlanROOFING SCHEDULEPITCH MATERIALUNDERLAYMENT4:12 and steeper Comp. Shingle 15# min roofing felt2:12, 3:12 Comp. Shingle Self-healing membrane1:12 Steel Standing Seam High temp self-healing membrane1:12 Steel Standing Seam None where spans between perlins1/4:12 Adhered Low-slope membrane NoneNOTE:1. ALL ROOFS CLASS B COMP. SHINGLE UON2. SELF-HEALING MEMBRANE AT ALL EAVES EXTENDING FROM LOWEST POINT TO 36" MIN INSIDE THEINTERIOR SURFACE OF THE WALL BELOW3. SELF-HEALING MEMBRANE AT ALL VALLEYS EXTENDING 18" MIN, EA. SIDE OF VALLEY4. WHERE ROOF SURFACES ABUT WALLS ABOVE, SELF-HEALING MEMBRANE SHALL EXTEND 36" MIN.EA. SIDE OF ROOF-WALL JOINT5. SELF-HEALING MEMBRANE UNDERLAYMENT TO EXTEND A MINIMUM OF 36" ONTO ROOF SURFACESADJACENT TO 2:12 PITCH ROOFS6. 36" SELF-ADHERING ROOF FLASHING AT EACH RIDGE AND HIP WITHOUT RIDGE VENTING7. NO ROOF PENETRATIONS WITHIN 36" OF VALLEYS AND PITCH BREAKS AND 48" OF PARTY WALLS8. SELF-HEALING MEMBRANE WITHIN 18" OF ALL ROOF PENETRATIONS.FLOOR PLAN KEYED NOTESNOTE#NOTE TEXT0 UL RATED 2A:10BC PORTABLE FIREEXTINGUISHER IN SURFACE MOUNTED CABINET1 CRAWL SPACE ACCESS. SEE DETAIL 4/A9.22 CLOSET WITH POLE AND SHELF3 CLOSET WITH 4 SHELVES4 EXPOSED BEAM ABOVE, TYP., SSD. PROTECTDURING CONSTRUCTION, CLR FINISH5 PLUMBING AND/OR MECHANICAL CHASE, TYP.,CLUSTER DUCTS/PIPES IN CORNER AND SIZECHASE MINIMUM NECESSARY6 PORCH RAILING +32" ABOVE T.O.C., TYP. WHEREADJACENT SURFACE IS LESS THAN 30" BELOWPORCH7 GUARD RAIL +36", TYP. @ ALL DECKS AND WHEREADJACENT SURFACE IS GREATER THAN 30"BELOW PORCH.8 SKYLIGHT OPENING, (ABOVE WHERE DOTTED)9 STEEL TREE GRATE10 PLANTER11 VERTICAL SPRINKLER RISER12 BED N.I.C13 AED & FIRST AID KIT WITH (2) NARCAN NASALSPRAY14 BOLLARD15 PLANTER UNDER WINDOWROOF PLAN KEYED NOTESNOTE#NOTE TEXT0 GANG ALL PLUMBING VENTS FOR EACH UNIT INTOA SINGLE ROOF PENETRATION, TYP.1 RIDGE VENTING, TYP.2 METAL AWNING, TYP.3 3" O.G. GUTTER, TYP. SEE DETAIL 1/A9.74 2" DOWNSPOUT. WHERE NECESSARY, HOLD OUTFROM WALL SEVERAL INCHES TO AVOID BELLYBAND USING A STRIAGHT DOWNSPOUT RUN. SEEDETAIL 2/A9.75 RAW STEEL RAIN CHAIN, TYP.6 STANDING SEAM ROOFING7 SOLAR TUBE, TYP. LOCATE ON NORTH SIDE,COORD. W/ SOLAR LAYOUT. SEE DETAIL 9/A9.5.18 CRICKET, TYP. SEE DETAIL 10/A9.69 EXTERIOR WALL BELOW10 HOLD IN TRUSS FOR STRUCTURAL HEADERABOVE TOP PLATE11 DIVERTER12 POST BELOW