Loading...
HomeMy WebLinkAboutA3.0.2BuildingFirstFloorTypeA_08-25-21REF.DWDNW/DN.I.CW/DN.I.CW/DN.I.CDNA4.04A4.02A4.03A4.01533 SFT.H. 3/2983 SFF.i. 2/1569 SFT.H. 2/1.5SOLAR TUBEDN1A5.02A5.013' - 4"32' - 5 1/2"0' - 1 1/2" 16' - 8"LIVING/DININGKITCHENBEDROOMBEDROOMBATHBEDROOMBEDROOMBATHBATHBEDROOMBEDROOMDECK12' - 6"3' - 5"10' - 10"8' - 2"6"5' - 4"17' - 0"12' - 0"5' - 1"10' - 7"8' - 6"15' - 2"2' - 0"2' - 0"3' - 0"12' - 0"11' - 5"8' - 11"9' - 2"3' - 7"3' - 0"3' - 0"8' - 5"2' - 4"7' - 6"4' - 1"3' - 0"2' - 2"23' - 5"8' - 10"10"11"5"3"3"8"EQ EQ3' - 2"7"3"4"3"11' - 8"4' - 9"40' - 6"EQ EQ6' - 5"4' - 0"2' - 0"1' - 4"8' - 9"4' - 1"3' - 0"3111101101106106112102104106102101112102101117102106T4T20T17F29T20A1F20T4T4T4F21A1T20F26T20T14T14T1436"36"3' - 6"1' - 6"4A5.03A5.05' - 2"57CARPETW.R. LAM.W.R. LAM. LAMINATE CARPETLAMINATELAMINATECARPETCARPETW.R. LAM.2' - 0"8' - 0"8' - 0"4' - 0"2' - 6"10' - 1"10' - 1"5' - 10"5A5.0A9.75A3F7A17' - 10"5' - 5"1' - 0"3' - 9"62' - 7"18' - 11"3' - 8"1A5.02A5.03:1210:1210:124:124:1210:1210:1210:1210:121:124:121' - 0"1' - 0"3' - 0"7' - 0"7' - 0"3' - 0"9' - 1"16' - 10"4A5.03A5.01345561' - 0"1' - 6"9' - 6"1' - 0"1' - 6"5' - 6"14' - 11"14' - 10"291032' - 7"1175A5.0111' - 0"S.H.M. UNDERLAYMENT ON ROOF& ADJACENT WALLSFLOOR PLAN GENERAL NOTES:1. GANG PLUMBING VENTS IN ATTAC FOR MINIMUM ROOF PENETRATIONS2. ROUTE ALL PLUMBING VENTS TO NORTH-FACING ROOFS WHEN POSSIBLE.3. COORDINATE ALL ROOF PENETRATIONS WITH THE SOLAR LAYOUT4. SEE ELECTRICAL PLANS FOR SOFFIT AND ATTIC ACCESS. 5. SEE SHEETS A8 FOR INTERIOR PLANS AND ALL KITCHEN & BATHROOM INTERIOR ELEVATIONS.6. ALL DIMENSIONS ARE TO FACE OF FRAMING, U.O.N.7. ALL EXTERIOR WALLS ARE 2X6 @ 24" O.C., U.O.N.8. ALL INTERIOR WALLS ARE 2X4 @ 24" O.C., U.O.N.INSULATED WALLS AT ALL INTERIOR BEDROOMS AND BATHROOM WALLS. CLOSET WALLS TO BE UNINSULATED. UON9. ALL DOORS TO HAVE DBL 2X JAMBS MIN.10. ALL CLOSETS ARE POLE AND 4 SHELVES U.O.N., SEE DETAIL X/AXX11. INSTALL TRANSITION STRIP BETWEEN DIFFERENT FLOORING, TYP.12. INSTALL GYP BOARD BEHIND SHOWERS ON PARTY WALLS ONLY13. CONTINUE PLYWOOD SHEATHING ON AN INT. WALL WHERE SHEAR WALLS DO NOT EXTEND THE FULL LENGTH OF A ROOM, IN ORDER TO MAINTAIN A FLAT WALL FACE. IT IS NOT NECESSARY TO CONTINUE SHEAR NAILING BEYOND THE LIMITS REQ'D BY STRUCT. ENGINEER14. 5/8" TYPE X GYP. BD. TYP. @ ALL INTERIOR WALL SURFACES, EXCEPT BATHROOMS. 5/8" TYPE X GYP. BD. "GREEN ROCK" @ ALL BATHR'MS15. 4-1/4" WOOD BASEBOARDS AT ALL WALLS, U.O.N.16. ALL ADJACENT WINDOWS TO BE MULLED TOGETHER17. MINIMUM WIDTH ON STAIRS SHALL BE 36" W/ A MINIMUM OF A 6'-8" CLEAR HEAD HT ABOVE NOSING. HANDRAILS SHALL NOT PROJECT MORE THAN 4 1/2" INTO STAIRS18. MAXIMUM STAIR RISER SHALL BE 7 3/4" WITH 10"-11" TREADS. PROVIDE NO MORE THAN 1/4" VARIATION FROM THE LARGEST TO THE SMALLEST RISER19. PROVIDE A HANDRAIL ON AT LEAST (1) SIDE OF A STAIR RUN W/ MORE THAN 4 RISERS. HANDRAIL SHALL BE 34" ABOVE SLOPED PLAIN OF STAIR NOSINGS20. SEE SHEET A14.0 FOR FLOORING SCHEDULE. TYPICAL FLOORING MATERIALS (EXCEPT COMMON HOUSE):A. CARPET IN BEDROOMS, UONB. WATER RESISTANT LAMINATE IN BATHROOMS AND ENTRANCES, RUN 90 DEGREES TO ADJACENT LAMINATE, UONC. LAMINATE ELSEWHERE, UON21. SEE FIRE EXTINGUISHERS LOCATIONS ON MECHANICAL PLANS Sheet Title:DateDrawn ByProject NumberM.B & E.BBYREVISIONSArchitect:STUDIO CO+HAB, LLC914 W Babcock StBOZEMAN, MT 59715651.336.0394erik@studiocohab.com8/25/2021 4:46:34 PMA3.0.22nd Floor & Roof PlanType ABozemanCohousingBozeman Coho, LLC8/25/20211904BOZ3120 Wagonwheel Rd.Bozeman, MT, 59715Formal Site Plan - 3rd SubmittalFormal Site Plan -3rd Submittal1/4" = 1'-0"1Building Type A - 2nd Floor1/8" = 1'-0"2Building Type A - Roof PlanDIVERTER(Buildings III, V, VI & VIII)FLOOR PLAN KEYED NOTESNOTE#NOTE TEXT0 UL RATED 2A:10BC PORTABLE FIREEXTINGUISHER IN SURFACE MOUNTED CABINET1 CRAWL SPACE ACCESS. SEE DETAIL 4/A9.22 CLOSET WITH POLE AND SHELF3 CLOSET WITH 4 SHELVES4 EXPOSED BEAM ABOVE, TYP., SSD. PROTECTDURING CONSTRUCTION, CLR FINISH5 PLUMBING AND/OR MECHANICAL CHASE, TYP.,CLUSTER DUCTS/PIPES IN CORNER AND SIZECHASE MINIMUM NECESSARY6 PORCH RAILING +32" ABOVE T.O.C., TYP. WHEREADJACENT SURFACE IS LESS THAN 30" BELOWPORCH7 GUARD RAIL +36", TYP. @ ALL DECKS AND WHEREADJACENT SURFACE IS GREATER THAN 30"BELOW PORCH.8 SKYLIGHT OPENING, (ABOVE WHERE DOTTED)9 STEEL TREE GRATE10 PLANTER11 VERTICAL SPRINKLER RISER12 BED N.I.C13 AED & FIRST AID KIT WITH (2) NARCAN NASALSPRAY14 BOLLARD15 PLANTER UNDER WINDOWROOFING SCHEDULEPITCH MATERIALUNDERLAYMENT4:12 and steeper Comp. Shingle 15# min roofing felt2:12, 3:12 Comp. Shingle Self-healing membrane1:12 Steel Standing Seam High temp self-healing membrane1:12 Steel Standing Seam None where spans between perlins1/4:12 Adhered Low-slope membrane NoneNOTE:1. ALL ROOFS CLASS B COMP. SHINGLE UON2. SELF-HEALING MEMBRANE AT ALL EAVES EXTENDING FROM LOWEST POINT TO 36" MIN INSIDE THEINTERIOR SURFACE OF THE WALL BELOW3. SELF-HEALING MEMBRANE AT ALL VALLEYS EXTENDING 18" MIN, EA. SIDE OF VALLEY4. WHERE ROOF SURFACES ABUT WALLS ABOVE, SELF-HEALING MEMBRANE SHALL EXTEND 36" MIN.EA. SIDE OF ROOF-WALL JOINT5. SELF-HEALING MEMBRANE UNDERLAYMENT TO EXTEND A MINIMUM OF 36" ONTO ROOF SURFACESADJACENT TO 2:12 PITCH ROOFS6. 36" SELF-ADHERING ROOF FLASHING AT EACH RIDGE AND HIP WITHOUT RIDGE VENTING7. NO ROOF PENETRATIONS WITHIN 36" OF VALLEYS AND PITCH BREAKS AND 48" OF PARTY WALLS8. SELF-HEALING MEMBRANE WITHIN 18" OF ALL ROOF PENETRATIONS.ROOF PLAN KEYED NOTESNOTE#NOTE TEXT0 GANG ALL PLUMBING VENTS FOR EACH UNIT INTOA SINGLE ROOF PENETRATION, TYP.1 RIDGE VENTING, TYP.2 METAL AWNING, TYP.3 3" O.G. GUTTER, TYP. SEE DETAIL 1/A9.74 2" DOWNSPOUT. WHERE NECESSARY, HOLD OUTFROM WALL SEVERAL INCHES TO AVOID BELLYBAND USING A STRIAGHT DOWNSPOUT RUN. SEEDETAIL 2/A9.75 RAW STEEL RAIN CHAIN, TYP.6 STANDING SEAM ROOFING7 SOLAR TUBE, TYP. LOCATE ON NORTH SIDE,COORD. W/ SOLAR LAYOUT. SEE DETAIL 9/A9.5.18 CRICKET, TYP. SEE DETAIL 10/A9.69 EXTERIOR WALL BELOW10 HOLD IN TRUSS FOR STRUCTURAL HEADERABOVE TOP PLATE11 DIVERTER12 POST BELOW