HomeMy WebLinkAboutA0.1CoverSheet_08-25-211A1.2ELEVATIONSHEET #DRAWING #1A1.2SECTIONSHEET #DRAWING #1A1.2DETAILSHEET #DRAWING #WINDOW TYPEDOOR TYPEHARDWARE GROUP(see specifications for hardware groups)PLUMBING & MECHANICAL FIXTURE TYPEELECTRICAL FIXTURE TYPE1REVISIONKEY NOTEMATERIALMT-1F1F111SHEET NOTE1Sheet Title:DateDrawn ByProject NumberM.B & E.BBYREVISIONSArchitect:STUDIO CO+HAB, LLC914 W Babcock StBOZEMAN, MT 59715651.336.0394erik@studiocohab.com8/25/2021 4:46:27 PMA0.1Cover SheetBozemanCohousingBozeman Coho, LLC8/25/20211904BOZ3120 Wagonwheel Rd.Bozeman, MT, 59715Formal Site Plan - 3rd SubmittalFormal Site Plan -3rd Submittal1 THESE DRAWINGS CONSTITUTE A PORTION OF THE CONTRACT DOCUMENTS AS DEFINED IN THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION.2 THE CONTRACTOR SHALL REVIEW, EVALUATE, AND VERIFY ALL EXISTINGCONDITIONS AND DIMENSIONS FOR ADEQUACY TO RECEIVE THE NEW WORK AND COMPLETION OF THE PROJECT AND THE EMPLOYMENT OF LABOR THEREON BEFORE COMMENCING WORK. THE CONTRACTOR SHALL INFORM THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCY OR CONFLICT. FAILURE TO DO SO WILL NOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS TO FURNISH EQUIPMENT, MATERIALS, LABOR, AND SERVICES AS NECESSARY TO CARRY OUT THE PROVISIONS OF THE CONTRACT.3DEFINITIONSA. ACCEPTED: AS ACCEPTED BY THE ARCHITECTB. ACCEPTED EQUAL: AS ACCEPTED BY THE ARCHITECT AS BEING EQUIVALENT IN QUALITY, UTILITY, AND APPEARANCE.C. AS REQUIRED: AS REQUIRED BY REGULATORY REQUIREMENTS, BY REFERENCE STANDARDS, BY EXISTING CONDITIONS, BY GENERALLY ACCEPTED CONSTRUCTION PRACTICE, OR BY THE CONTRACT DOCUMENTS.D. DIRECTED: AS INSTRUCTED BY THE ARCHITECT IN WRITING.E. SATISFACTORY: TO THE SATISFACTION OF THE ARCHITECT, SUBJECT TO THE ARCHITECT'S ACCEPTANCE.F. TYPICAL: IDENTICAL FOR ALL SUCH CONDITIONS, UNLESS OTHERWISE NOTED.G. SIMILAR: COMPARABLE CHARACTERISTICS FOR THE CONDITION NOTED. DIFFERENCES CAN BE INFERRED FROM OTHER INFORMATION INDICATED. VERIFY DIMENSIONS AND ORIENTATION.4. DETAILS USUALLY TAKE PRECEDENCE OVER GENERAL DRAWINGS. HOWEVER, WHEN IN CONFLICT REQUEST CLARIFICATION FROM THE ARCHITECT. ANY CONFLICT IN THE DRAWINGS ARE TO BE CLARIFIED BY THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.5 DIMENSIONING RULES:A. ALL HORIZONTAL DIMENSIONS ARE TO FACE OF STUD AND DO NOT INCLUDE FINISH MATERIALS UNLESS OTHERWISE INDICATED.B. DIMENSIONS NOTED "CLEAR" MUST BE PRECISELY MAINTAINED.C. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT ACCEPTANCE BY THE ARCHITECT, UNLESS NOTED (+/-) OR UNLESS NOTED V.I.F. (VERIFY IN FIELD). (+/-) IS A MAXIMUM VARIANCE OF ONE-QUARTER INCH.D. VERTICAL DIMENSIONS ARE FROM THE TOP OF THE SUBFLOOR DATUM LINE, ESTABLISHED BY THE CONTRACTOR SUBJECT TO THE ACCEPTANCE OF THE OWNER OR ARCHITECT, U.O.N.E. SOME DIMENSIONS ARE MARKED "A.S.F." (ABOVE THE SUBFLOOR.) THE TOP OF THE SUBFLOOR IS GENERALLY ABOVE THE PLYWOOD. WHEN CRITICAL, SOMEDIMENSIONS ARE MARKED “A.F.F.” (ABOVE FINISHED FLOOR).F. DO NOT SCALE DRAWINGS. IF ITEMS OF WORK CANNOT BE LOCATED, DO NOT PROCEED THE WORK WITHOUT THE CONSENT OF THE ARCHITECT.G. DIMENSIONS MARKED V.I.F. SHALL BE "VERIFIED IN FIELD” BY THE CONTRACTOR. RELAY FIELD MEASUREMENTS TO THE ARCHITECT FOR ARCHITECT'S REVIEW BEFORE PROCEEDING.6 OBTAIN PERMITS REQUIRED FOR A COMPLETE JOB.7 WHEN PORTIONS OF THIS PROJECT ARE PERFORMED BY THE CONTRACTOR ON A "DESIGN-BUILD" BASIS, THE CONTRACTOR, RATHER THAN THE ARCHITECT, IS SOLELY RESPONSIBLE FOR THE DESIGN OF SUCH SYSTEMS AND FOR THE COORDINATION OF THE DESIGN-BUILD SUBCONTRACTORS, WHO SHALL BE THE ENGINEERS OF RECORD FOR SUCH SYSTEMS. THE CONTRACTOR HAS RESPONSIBILITY FOR THE FOLLOWING DESIGN-BUILD PORTIONS OF THE WORK (WET STAMP TO FOLLOW):A: DATA / TELECOMMUNICATIONS AND ELECTRONIC ENTRY SYSTEMS B: FIRE PROTECTIONC: FIRE MONITORING D: TRUSSESALL DESIGN/BUILD CONSTITUTES A FULL AND COMPLETE AND FINISHED JOB. IT INCLUDES ALL WORK REQUIRED BY OFFICIALS AND TO PERFORM AS EXPECTED. IT INCLUDES ALL PERMITS AND COORDINATION WITH G.C. AND OTHER SUBCONTRACTORS.8 COOPERATE WITH OTHERS AND COORDINATE WORK BY OTHERS OUTLINED BELOW: A: TELEPHONE / DATA / COMMUNICATIONS CABLING INSTALLATION.B: EQUIPMENT AND APPLIANCE INSTALLATION.9 THE CONTRACTOR SHALL EXAMINE, READ AND BE THOROUGHLY FAMILIAR WITH THE CONTRACT DOCUMENTS. SHOULD THE CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS AND SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, OR BE IN DOUBT AS TO THEIR INTENT OR MEANING, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY FOR CLARIFIACTION OR INTERPRETATION.10 INFORMATION RELATED TO EXISTING CONDITIONS GIVEN HEREIN AND ON THE DRAWINGS WAS OBTAINED FROM OWNER-PROVIDED DOCUMENTATION AVAILABLE TO THE ARCHITECT AT THE TIME OF DESIGN. THE ACCURACY OF SUCH INFORMATION HAS NOT BEEN VERIFIED. DRAWINGS AND SPECIFICATIONS ARE INTENDED FOR ASSISTANCE AND GUIDANCE, BUT EXACT DIMENSIONS AND ELEVATIONS SHALL BE GOVERNED BY ACTUAL CONDITIONS AT THE SITE AND SHALL BE CHECKED BY THE CONTRACTOR.11 INSTALL WORK PLUMB, LEVEL, SQUARE, TRUE AND IN PROPER ALIGNMENT.12 PROVIDE REQUIRED BLOCKING AND BACKING FOR ALL WALL HUNG CASEWORK, ACCESSORIES, GRAB BARS,ETC.13 SEE PROJECT SPECIFICATIONS FOR DETAILED MATERIAL SPECIFICATIONS. ALL SUBCONTRACTORS TO HAVE RELAVANT SPECS ON THE JOB AS WELL AS PLANS.14 ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY THE ARCHITECT ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT AND ARE NOT TO BE USED ON ANY OTHER PROJECT. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THE PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THE ARCHITECT’S COMMON LAW COPYRIGHT OR OTHER RESERVED RIGHTS.GENERAL ARCHITECTURAL CONDITIONS15 ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY CHANGES FROM CONSTRUCTION DOCUMENTS UNLESS APPROVED IN WRITING IN ADVANCE OF CONSTRUCTION. DO NOT SUBSTITUTE, REVISE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.16 INSTALL ALL MATERIALS AND EQUIPMENT FOR MANUFACTURER’S WRITTEN RECOMMENDATIONS. IF MANUFACTURERS RECOMMENDATIONS CONFLICT WITH THESE DRAWINGS, INFORM ARCHITECT OF SAID DISCREPANCIES.17 ALL WORK SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES AND SAFETY ORDINANCES IN EFFECT AT THE PLACE OF BUILDING. REFER TO “BUILDING CODE REVIEW” SECTION ON THIS COVER SHEET FOR SPECIFIC CODES.18 IT IS THE INTENT OF THESE DOCUMENTS TO FULLY COMPLY WITH ALL CODE AND OTHER REQUIREMENTS. WHERE DIMENSIONS AND OTHER CRITICAL CRITERIA ARE NOTED, THEY ARE TO BE ADHERED TO EXACTLY, UNLESS NOTED AS V.I.F OR +-. CONTRACTOR’S FAILURE TO COMPLY WITH ANY PROVISION DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS RELATED TO THESE ACCESSIBILITY OR OTHER LAWS AND CODES WILL REQUIRE CORRECTION AT CONTRACTOR’S EXPENSE. WHERE MAXIMUM OR MINIMUM DIMENSIONS AND SLOPE GRADIENTS ARE NOTED, NO EXCEPTION WILL BE MADE FOR NOT MEETING THESE REQUIREMENTS.19 EACH SUBCONTRACTOR IS CONSIDERED A SPECIALIST IN HIS/HER FIELD AND SHALL, WITH THE SUBMISSION OF HIS/HER BID, NOTIFY THE GENERAL CONTRACTOR OF ANY WORK CALLED OUT IN THE DRAWINGS IN HIS/HER TRADE THAT CANNOT BE FULLY GUARANTEED. THEY ARE ALSO EXPECTED TO HAVE SUITABLE QUALIFIED PERSONELL PERFORM WORK SPECIFIED HEREIN.20 THE INTENT OF THIS JOB IS THAT IT BE COMPLETE IN ALL RESPECTS WITH ALL SYSTEMS OPERATIVE.21 CONFIRM, DURING THE BID PERIOD, ON-SITE DELIVERY DATES OF CONSTRUCTION MATERIAL SPECIFIED IN THE CONTRACT DOCUMENTS AND IMMEDIATELY NOTIFY THE ARCHITECT, IN WRITING, OF POTENTIAL DELAYS TO THE COMPLETION DATE OF THE PROJECT.22 SCHEDULE AND PERFORM THE WORK SO TO MINIMIZE THAT OTHER TENANTS IN THE NEIGHBORHOOD WILL NOT BE DISTRURBED, DAMAGE TO EXISTING WORK OUTSIDE OF THE PROJECT AREA WILL NOT OCCUR, AND TO COMPLY WITH THE PROPERTY OWNERS' REQUIREMENTS.23 SCHEDULE AND PERFORM THE WORK DURING NORMAL WORKING HOURS, ASDICTATED BY THE AGENCIES ORDINANCES.24 VERIFY IN FIELD ACCESS TO THE JOBSITE. NO ADDITIONAL COSTS WILL BE PAID TO THE CONTRACTOR DUE TO ITS FAILURE TO PLAN THE DELIVERY ROUTE AND METHOD FOR MATERIAL AND EQUIPMENT SPECIFIED.25 COORDINATE THE TRADES, CRAFTS AND SUBCONTRACTORS AS REQUIRED TO PROVIDE CORRECT AND ACCURATE CONNECTION OF ABUTTING, ADJOING, OVERLAPPING AND RELATED WORK. ITEMS OF EQUIPMENT, FIXTURES AND MATERIALS NOT DEFINETELY SPECIFIED HEREIN, BUT NECESSARY FOR COMPLETION OF THE WORK, SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS. SUCH ITEMS SHALL BE OF TYPE AND QUALITY SUITABLE FOR THE SERVICE REQUIRED AND COMPARABLE TO ADJACENT OR SIMILAR ITEMS ON THE SITE AND PER CODE. PROVIDE ANCHORS, FASTENERS, ACCESSORIES, APPURTENANCES, CAULKING AND SEALING, FLASHING, AND INCIDENTAL ITEMS AS REQUIRED TO COMPLETE THE WORK PROPERLY, FULLY AND CORRECTLY IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.26 WHEREVER IN THE SPECIFICATIONS THE ABBREVIATION OR ACRONYM IS SPECIFIED, IT SHALL BE UNDERSTOOD TO MEAN THE FULL NAME OF THE RESPECTIVE ORGANIZATION, AS FOLLOWS:ANSI AMERICAN NATIONAL INSTITUTE OF STANDARDS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWI ARCHITECTURAL WOODWORK ASSOCIATIONICBO INTERNATIONAL CONFERENCE OF BUILDING OFFICIALSUL UNDERWRITERS LABATORIES, INC27 SHOP AND FIELD WORK SHALL BE PERFORMED BY MECHANICS, CRAFTSPERSONS, AND WORKERS SKILLED AND EXPERIENCED IN THE FABRICATION AND INSTALLATION OF THE WORK INVOLVED. WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BEST AND ACCEPTED PRACTICES OF THE VARIOUS TRADES INVOLVED.28 THE ARCHITECT RESERVES THE RIGHT TO REJECT MATERIALS AND WORK QUALITY WHICH ARE NOT CONSIDERED TO BE UP TO THE SPECIFIED STANDARDS OF THE VARIOUS TRADES INVOLVED. SUCH INFERIOR MATERIAL OR WORK QUALITY SHALL BE REPAIRED OR REPLACED, AS DIRECTED, AT NO ADDITOINAL COST TO THE OWNER.29 WHERE SIZE, CAPACITY, MODEL, STYLE OR OTHER PERTINENT INFORMATIONS IS NOT INDICATED ON THE DRAWINGS, FURNISH EQUIPMENT, FIXTURES, OR MATERIALS OF SIZE, QUALITY, AND UTILITY WHICH WILL MEET APPLICABLE CODE REQUIREMENTS AND WHICH WILL ADEQUATELY SEVICE THE VARIOUS BUILDING FACILITIES AS REQUIRED. WHERE THESE ARE VISIBLE IN THE FINAL WORK, OBTAIN ARCHITECT'S APPROVAL BEFORE PROCEEEDING.30 THE DRAWINGS BY THE STRUCTURAL ENGINEER TAKE PRECEDENCE OVER THE ARCHITECTURAL REGARDING ANY STRUCTURAL ISSUES. HOWEVER, ALL SAID CONFLICTS ARE TO BE CLARIFIED BEFORE PROCEEDING. IN THESE CASES, THE RELEVANT ARCHITECTURAL DETAILS SHOULD BE CONSIDERED TO BE FOR THE FINISHES, COORDINATION AND REFERENCE ONLY.31 USE OF THESE PLANS BY THE OWNER AND GENERAL CONTRACTOR REQUIRES COOPERATION AND COMMUNICATION AMONG THE OWNER, GENERAL CONTRACTOR AND ARCHITECT. ANY AMBIGUITY, DISCREPANCY OR OMISSION DISCOVERED DURING THE USE OF THESE PLANS BY THE OWNER, GENERAL CONTRACTOR, GENERAL CONTRACTOR'S SUBCONTRACTORS OR ANY OTHER PERSON OR ENTITY AUTHORIZED BY THE OWNER OR GENERAL CONTRACTOR SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY. THE FAILURE TO DO SO OR NOTIFY THE ARCHITECT SHALL RELIEVE THE ARCHITECT FROM ALL RESPONSIBILITY AND CONSEQUENCES RESULTING FROM SUCH AMBIGUITY, DISCREPANCY OR OMMISSION.32 ALL SCALES ARE TO BE PRINTED AT 24X36 & = AND L = ANGLE~ = APPROXIMATELY @ = ATCL= CENTER LINE⌀= DIAMETER OR ROUND+/- = DIMENSION MAY VARY UP TO 1" FROM SPECIFIED DIMENSION# = POUND OR NUMBERA.B. = ANCHOR BOLTA.C.T. = ACOUSTICAL CEILING TILEADA = AMERICANS WITH DISABILITIES ACTADJ. = ADJUSTABLEAFF = ABOVE FINISHED FLOOR ALT. = ALTERNATEALUM. = ALUMINUM APPROX. = APPROXIMATELY ARCH. = ARCHITECTURAL ASB. = ASBESTOSASF = ABOVE SUB FLOOR ASPH. = ASPHALTB = BASE CABINETBD. = BOARDBITUM. = BITUMINOUS BLDG. = BUILDINGBLK. = BLOCKBLKG. = BLOCKINGBM. = BEAMBOT. = BOTTOMBTW. = BETWEENCAB. = CABINETC.B. = CATCH BASINCER. = CERAMICC.H. = COMMON HOUSEC.M.U. = CONCRETE MASONRY UNITCLG. = CEILINGCLKG. = CAULKINGCLO. = CLOSETCLR. = CLEARCNTRSK. = COUNTERSUNK COL. = COLUMNCONC. = CONCRETECONN. = CONNECTION CONSTR. = CONSTRUCTION CONT. = CONTINUOUSCPT. = CARPETCTR. = CENTERC.W. = COLD WATERD = PENNY (NAIL)D = DRYERDB = DRAWER BASE CABINET DBL. = DOUBLEDF = DOUG FIRDET. = DETAILD.G. = DOUBLE GLAZEDD.H. = DOUBLE HUNGDIM. = DIMENSION DN. = DOWND.S. = DOWNSPOUTD.S.P. = DRY STANDPIPEDW = DISHWASHER(E) = EXISTINGEA. = EACHE.J. = EXPANSION JOINT ELEC. = ELECTRICALEMER. = EMERGENCYE.P. = ELECTRICAL PANELBOARDEQ. = EQUALF.A. = FIRE ALARMF.A.I. = FRESH AIR INTAKE FAU = FORCED AIR UNIT FDN. = FOUNDATIONF.E. = FIRE EXTINGUISHERF.E.C. = FIRE EXTINGUISHER CABINETF.F. = FINISHED FLOORF.G. = FINISH GRADEF.H.C. = FIRE HOSE CABINET F.H.W.S. = FLAT HEAD WOOD SCREWFIN. = FINISHFLASH. = FLASHINGABBREVIATIONSFLR. = FLOORFLR’G = FLOORINGFLUOR. = FLUORESCENTF.O. = FACE OFF.O.F. = FACE OF FINISHF.O.P. = FACE OF PLYWOOD F.O.S. = FACE OF STUDF.O.W. = FACE OF WALLFT. = FOOT OR FEETFTG. = FOOTINGFURR. = FURRINGF.W. = FLAT WASHERGA. = GAUGEGALV. = GALVANIZEDG.B. = GRAB BARG.F.I. = GROUND FAULT INTERRUPTG/L = GLU-LAMGND. = GROUNDGPM = GALLON PER MINUTE GR. = GRADEG.S.M. = GALVANIZED SHEET METALGYP. BD. = GYPSUM BOARDG.W.P. = GLOBAL WARMING POTENTIAL H.B. = HOSE BIBBH.C. = HOLLOW CORE HDWD. = HARDWOODHT. = HEIGHTI.F.S. = INSIDE FACE OF STUD INS. = INSULATIONINT. = INTERIORJT. = JOINTKIT. = KITCHENK.D. = KILN DRIEDLAM. = LAMINATE LAV. = LAVATORY LINO = LINOLEUMMAP = MAPLEMAX. = MAXIMUMM.B. = MACHINE BOLT MECH. = MECHANICAL MEMB. = MEMBRANEMED. = MEDICINEMFR. = MANUFACTURER MGR = MANAGERM.H. = MANHOLEMIC. = MICROWAVEMIN. = MINIMUMMISC. = MISCELLANEOUS MTD. = MOUNTEDMTL. = METAL(N) = NEWN.I.C. = NOT IN CONTRACT NO. OR # = NUMBERNOM. = NOMINALN.T.S. = NOT TO SCALEO/ = OVERO.C. = ON-CENTERO.F.I.C. = OWNER FURNISHED, CONTRACTOR INSTALLEDO.F.S. = OUTSIDE FACE OF STUDO.H.W.S. = OVAL HEAD WOOD SCREWOPG. = OPENINGOPP. = OPPOSITEO.S.B. = ORIENTED STRAND BOARDOV. = OVERP.H. = PRIVATE HOUSEP.L. = PROPERTY LINEPL = STEEL PLATEP. LAM = PLASTIC LAMINATE PLAS. = PLASTERPLYWD = PLYWOODPR. = PAIRPRCST. = PRECASTPT. = PAINTP.T. = PRESSURE TREATED PTD. = PAINTEDP.T.D. = PAPER TOWEL DISPENSERPWD. = PLYWOODR = RADIUSR. = RISERR. & S. = ROD AND SHELF R.D. = ROOF DRAINREF. = REFRIGERATOR REQ. = REQUIREDREQ’T = REQUIREMENT RES. = RESIDENTIALRESIL. = RESILIENTR.H.M.S. = ROUND HEADEDMACHINE SCREW RM. = ROOMR.O. = ROUGH OPENING RWD. = REDWOODR.W.L. = RAIN WATER LEADERSB = SINK BASE CABINETS.B.O. = SUPPLIED BY OWNERS.C. = SOLID CORESCHED. = SCHEDULES.D. = SMOKE DETECTORSECT. = SECTIONS.E.D. = SEE ELECTRICAL DRAWINGSSF = SQUARE FEETS.G. = SINGLE GLAZEDS.H. = SINGLE HUNGSHLVS. = SHELVESS.H.M. = SELF-HEALING MEMBRANESHR. = SHOWERSIM. = SIMILARS.M.D. = SEE MECHANICAL DRAWINGSS.M.S. = SHEET METAL SCREW S.O.G. = SLAB ON GRADES.O.V. = SHUT OFF VALVE SPEC. = SPECIFICATION(S)SQ. = SQUARES.S.D. = SEE STRUCTURAL DRAWINGS S.ST. = STAINLESS STEELSTD. = STANDARDSTL. = STEELSTOR. = STORAGESTRUC. = STRUCTURALS.T.S.M.S. = SELF-TAPPING SHEET METAL SCREW SUSP. = SUSPENDEDSYM. = SYMMETRICALT. = TREADT. & G. = TONGUE & GROOVE T.B. = TOWEL BARTEL. = TELEPHONETHK. = THICKTJI = TRUSS JOISTT.O. = TOP OFT.S. = TUBULAR STEELTYP. = TYPICALU.L. = UNDERWRITERS' LABORATORYUNF. = UNFINISHEDU.O.N. = UNLESS OTHERWISE NOTEDVAR. = VARIESV.C.T. = VINYL COMPOSITION TILEVEN. = VENEERVERT. = VERTICALVEST. = VESTIBULEVFY. = VERIFYV.G. = VERTICAL GRAIN DOUGLAS FIRV.G.D.F. = VERTICAL GRAIN DOUGLAS FIRV.I.F. = VERIFY IN FIELDW = WASHING MACHINEW/ = WITHWC = WALL CABINETW.C. = WATER CLOSETW/D = WASHING MACHINE / DRYERWD. = WOODW.H. = WATER HEATERW.O. = WHERE OCCURSW/O = WITHOUTWP. = WATERPROOFWWF = WELDED WIRE FABRICSYMBOLS LEGEND ARCHITECTURAL SPECIFICATION NOTES