Loading...
HomeMy WebLinkAboutC1.1GeneralCivilandUtilityPlan_08252021 o EXISTING ll� NTANgnK FILL SLOPE EASEMENT EXISTING (DOC.#2646562) -' f o Matthew B. o 62.5'WIDE PUBLIC STREET eql _ Cotterman &UTILITY EASEMENT s 15873ES _________ ______ __ ____ Fy !/CENSER 5J 0 30 60 SLALE IN FEETi15{I- CONTOURINTERVAL=1' SECTION LINE T ---------I-���������w��_,w�� ��� � West Oak Street "RAN BENCHMARK: TOP OFOF BOZEMAN T=4726.93 FEET -aW� ow -ow yaw d� TI m (CITY OF BOZEMAN DATUM) � � OUSTING SIOEWnu� °'"'-� i -- - -- -- -- -- ----- ---- - Y LP • O PARKING „ EXISTING SIDEWALK LEGEND �- -- -- •--------- ------ _ -- -- --- -- • PROPERTY MONUMENT(AS NOTED) _ _ __ __--- _-__ _-_ _____ ____ ____ ____ ______ _ _______ ______ ______ _-__ _--_ _____ ____-_ ______ ______ --______ _--________- I r _ _ _ _ _ \ aPROPERTY LINE _� o�. „ \': - -._--.-.-.- -.-. -.-.- - -.- - -._.� �� --__-_---_._ _-_ ____.-.-___ \ A-I -----ADJOINING PROPERTY LINE g 30 x UISTIN9STuauwrrtx Fxls xssroauvwTeR - y of EASEMENT LINE w a COMMON AREA NO__________EXISTING MAJOR CONTOUR LINE(5'INTERVAL) ; „ N -.-_-. -.-.-.-.- -__.- - s I•s _ _ -._.- _._ _ •. `gym _ III �Cy EXISTING MINOR CONTOUR LINE T INTERVAL "�� - - - - - - - - - - - - - _ - _ _- - - - W � UNDERGROUND ELECTRICAL LINE i NS TALL E.-•.-OVERHEAD POWER LINE ( ) 5 - -27V - I + y- i ' PP ... � ... :. r.eT.WALL 00� 4 POWER POLE - :: .... Cy. W .I, GUYANCHORWIRE RM'0 tlY 31ILDING1 rlj BUILDING BUILDING 3' :: LLD,,G4 I� I `•/ -4-s-w-EXISTING UNDERGROUND GAS LINE f -- 12 PLEX 12 PLEX I I I -z-s-4-EXISTING UNDERGROUND COMMUNICATION LINE ®" -- - v r I-*s-N.-M-EXISTING UNDERGROUND CABLE TV LINE WATER LINE € 'P * (J ® j ® = 5,5'r---r1a0cHrw MLNT .-. � y -- .h- FIRE HYDRANT %L E STING 4 WATER VALVE T ^. FA E I '"^ - I' �l ® WATER SERVICE CURB STOP T - I _ MEN RMELEV--4]24.1 SANITARY SEWER LINE (13 T ---- - ------ -- SS SANITARY SEWER MANHOLE # a 7 F_ "`�` ____ __ T�tiASFi II ® STORM SEWER MANHOLE X _ - 4f + ' -- - - D - E�S +zs�,z"sue STORM DRAIN LINE SAWCUTEXIS TIN GAA$$PPHALT %4 „ osEO oENWL LP CONNECTTOEXISTIN6SENER - - - -- -- -- - -- -- - - -� I I K LIGHT POLE NNE MANHOLE N \ 1+ LNk]2p.16 IS.0 RIM ELEV ------- EXISTING CURB AND GUTTER EXISTING FL471�50 9 J 24,E - FL E4718]0 _ � TT TRAFFIC SIGN INS TALL NON-RESIDENTIAL LOT�5 �$!--,. �� sss-ass�ss�°ss� +II _ I, �/•X ^ : �A -� DRNENAYAPPRO CH PER g P '- ss O © EXISTING COMMUNICATION BOX COB STO GwG No p252&2 P" 0,9 gFt1 1� (SEEDETAILI,i C7.1) E ''9.00 I-- 1.6114AC 3 � __ __ - y., ; _ __ __ _ ___ __ _ �E EXISTING ELECTRICAL BOX Z�S •I '•+ �' __ __ --1B. ' 18I 7I B'ILONIG7 > - •0 __ __ ___ __ __ _ 11 1oB lap p 0 24. la pp �,: PLEX �S O O � 'z I L }III U _ 4 IPT4 p ¢ --- _ mot'. b 9.W 6 � p „ INSTALL T - __ INSTALL R-O L p I PET WALL A RET WALL ISTING + Fil KEY NOTES (� i_ °p i24'STO ' 26.00 ----- .: I--�a INSTALL STAMPED CONCRETE CROSSWALK 1 - WITH BRICK PATTERN AND COLOR STEPS I� W f 25TEP _ 9.pD�---- I.BY Q INSTALL TXT CONCRETE UTILITY PAD �N BUILDING 13.op u.po 1B.DD 3sTEPs BUILDINGS 3sTEP _ CA Q PROPOSED 31'WIDE PUBLIC € 12 PLEX 12 PLEX h 7B. 17 RnN �) [� UTILITY&ACCESS EASEMENT x 5 �P .< �' 1e.00 I. - 0 PROPOSED IO'WIDE UTILITY EASEMENT Z�i ( ) Tpp_ 2 m MPROPOSEDy, o 6IDEWALK Q PROPOSED 30 WIDE SHAREDACCESS ): Q E. ° AND DRAINAGE EASEMENT _ STEPS acr I--1 I-�10 UTILITY EASEMENT TYP I STEP' i STEPS D _ PROPOSED 31'WIDE SHARED ACCESS EASEMENT # -" - rn _ -' - -'-" ^- _. N ._ ' I m I !"' 05 N90°00'00"� 30.99' SECTION LINE O EXISTIN RMl I I PED RAMP i /yy' G �'UTILITV EASEMENT �Sy r R .3S I _ 20 �F a,. � v - c ---- I I I � O rxl ram, T PR OSE ID -- PROPOSED SIDENNLK '6� ISTING CURB INLET j �+ �../ w ' .�N ARKING - L TBC ELEV z 9.69 LOT 3 lll��, �1 ____ ___ __ - DRIVELNWYAPPROACHPR .H it O COB STD DAGG NO.0252412 tlur � „ REL TEEX N (S 1, I j w�w�w�w�wR- p�w�w )_ �./ _ L RAN Flanders W UNU SEX �� ^� 6p RAN S EXISTING SSMH N s�ss�°ss ss ss ss� °ss�ss�ss�ss�°ss�ss�ss ss --e ss�ss�ss�°ss�ss�ss�ss�°ss ss�ss�ssss Imo TRIM ELEV=4]28.46 I FLW=4721.27 z_ O �r I FLS=4721 47 r v i(D- I �i FLNE=4721A7 ------------------ -� ------------ T ------ i a I --------------------------------- �-----------------------------------, LOT 3 J i „ I m i I I I I � � yF� l `^ 6 GENERAL NOTES: 1. ALL CONSTRUCTION SHALL CONFORM TO THE ACCOMPANYING PLANS,MPWSS 6TH EDITION,APRIL 2010 AND CITY OF BOZEMAN MODIFICATIONS TO MPWSS, REV. DATE MARCH 2O11,ADDENDUM NO.1&ADDENDUM NO.2. �z°o 2. THECONTRACTOR SHALL VERIFY THE LOCATION OFALL BURIED UTILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. z 7lzo/n 3. TYPE 1 OR TYPE 2 TRENCH EXCAVATION MAY BE USED AT THE DISCRETION OF THE CONTRACTOR. 4. TRENCH BACKFILL SHALL BE TYPE A,FOR ALLAREAS TO BE PAVED. 5. THE INSTALLATION OF THE SANITARY SEWER SERVICE LINE FROM THE EXISTING SERVICE STUB TO THE BUILDING IS THE RESPONSIBILITY OF THE DEVELOPER. DRAWING DATE: 6. THE INSTALLATION OF THE WATER SERVICE LINES FROM THE EXISTING SERVICE STUBS TO THE BUILDING IS THE RESPONSIBILITY OF THE DEVELOPER. 7. AN APPROVED DOUBLE CHECK BACKFLOW PREVENTION DEVICE MUST BE INSTALLED FOR EACH NEW BUILDING SHOWN,PER CITY OF BOZEMAN 20 21 REQUIRMENTS. 8. CONTRACTOR TO FIELD VERIFY LINE AND GRADE OF EXISTING SEWER AT SERVICE CONNECTION POINT TO VERIFY ADEQUATE FALL FOR SEWER SERVICE. SHEET9. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT THE PROJECT MEETS OSHA AND ALLAPPLICABLE SAFETY REQUIREMENTS. 10. GROUND MOUNTED MECHANICAL EQUIPMENT,INCLUDING,BUT NO LIMITED TO UTILITIES,AIR EXCHANGE CONDITIONING UNITS,TRANSFORMERS AND METERS SHALL NOT ENCROACH INTO THE REQUIRED YARD SETBACKS AND SHALL BE PROPERLY SCREENED WITH AN OPAQUE SOLID WALL AND ADEQUATE LANDSCAPE FEATURES.ALL ROOFTOP MECHANICAL EQUIPMENT SHALL BE INCORPORATED INTO THE ROOF FORM OR SCREENED IN AN APPROVED ENCLOSURE. 11. PROPOSED DRY UTILITY(ELEC,GAS&COMMUNICATIONS)LOCATIONS SHOWN ARE PRELIMINARY.CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH UTILITY PROVIDERS. 12, DRY UTILITIES ANDASSOCIATED STRUCTURES SHALL BE LOCATED A MINIMUM OF I 0-FEET FROM PROPOSED WATER AND SEWER MAINS AND SERVICES. #20006