A4.1WallSections_07222021
LEVEL 1100' -0"LEVEL 2110' -8"UPPER ROOF BR'G118' -9"CBLOWER ROOF BR'G109' -0"PRE-FIN MTL DRIP EDGEPRE-FIN MTL GUTTER AND DOWNSPOUTSPRE-FIN MTL VENTED SOFFITPRE-FIN MTL FASCIA4" / 12"4" / 12"PRE-FIN MTL DRIP EDGEPRE-FIN MTL GUTTER AND DOWNSPOUTSPRE-FIN MTL FASCIAFIN. GRADE (SLOPE MIN. 2% AWAY FROM STRUCTURE)DASPHALT SHINGLES30# ASPHALT FELTCDX PLYWOOD OR OSB SHEATHING (SEE STRUCT.)BAFFLE VENTPRE-ENGINEERED WOOD TRUSSBLOCKINGR-49 BLOWN-IN INSULATION2x6's @ 16" O.C.PLYWOOD OR OSB SUBFLOOR (SEE STRUCT.)OPEN WEB FLOOR TRUSSES @ 24" OC (SEE STRUCT.)HARDIPLANK OR METAL PANEL SIDING(SEE EXTERIOR ELEVATIONS)STANDING SEAM MTL ROOFINGICE AND WATER SHIELD (UNDERENTIRE MTL ROOFING)MTL FLASHING (EXTEND BEHIND SIDING)2x12 RAFTERS @ 24" OC (SEE STRUCT.)PRE-FIN VMTL VENTED SOFFITGLU-LAM BEAM (SEE STRUCT.)R-15 RIGID INSULATION (MIN.)AT FOUNDATION PERIMETER(SEE STRUCT.)10 MIL. VAPOR BARRIER1 1/2"2x6's @ 16" O.C.4" CONC. SLAB ON GRADEOVER COMPACTED GRAVELEXPANSION JOINTPRE-FIN MTL FLASHINGAT RIGID INSULATION (BASE OF WALL)CONCRETE STOOPOVER COMPACTED GRAVEL (SLOPE MIN.2% AWAY FROM FND.)11 7/8" TJI FLOOR JOISTS (SEE STRUCT.)FLOOR SHEATHING (SEE STRUCT.)ICE AND WATER SHIELD -EXTEND MINIMUM 24" INSIDE EXTERIOR WALL LINE AND 18" BOTH SIDES OF VALLEYSCOMPACTED GRAVEL -SEE STRUCT.THICKENED EDGE SLAB ON GRADE -SEE STRUCT.METAL FLASHING OVER RIGID INSULATIONRIGID INSULATION -SEE STRUCT.R-3.8 MIN CONTINUOUS RIGID INSULATIONR-20 MIN. BLOWN FIBERGLASS INSULATIONPLYWOOD SHEATHING -SEE STRUCT.6A4.13A4.14A4.15LEVEL 1100' -0"2" USG C-RUNNER (WITH POWERDRIVEN FASTENERS @ 24" OC)(2) 1" GYP. BD. LINER PANELSSEALANTSOUND INSULATION1/2" GYP. BD.1" AIR SPACE2x4's @ 16" OC (TYP)SILL PLATE IN SILL SEALLEVEL 2110' -8"LOWER ROOF BR'G109' -0"FIRE BLOCKING(2) USG C-RUNNERSUSG BREAKAWAYCLIPSSOUND INSULATION3/8" TYPE S PANHEAD SCREW1 1/4" TYPE W OR SSCREW1/2" GYP. BD.2x4 STUDS @ 16" OCLVL RIM JOIST (SEE STRUCT.)SEALANTUPPER ROOF BR'G118' -9"SAW CUT2" USG C-RUNNERPRE-ENGINEERED TRUSSROOF SHEATHING-(SEE STRUCT.) (FIRE-TREATED 4'-0" BOTHSIDES OF DEMISING WALLS)(2) 1" GYP. BD. LINER PANELSUSG BREAKAWAY CLIPFIRE BLOCKING1/2" GYP. BD.USG BREAKAWAY CLIP2x4 STUDS @ 16" OC1713TIMOTHY M. PETERSONGREAT FALLSMTLICENSEARCHITE C TD S TATEOFMONTANAwww.lpwarchitecture.comPHONE | 406.771.077015 FIFTH ST. SOUTHGREAT FALLS | MT 59401SHEET NUMBER:PROJECTNUMBER:DATE:CHECKED BY:DRAWN BY:THIS DRAWING IS THE PROPERTY OF THE ARCHITECT. IT HAS BEEN PREPARED SPECIFICALLY FOR THIS SITE AND IS NOT TO BE USED FOR ANY OTHER PURPOSE, LOCATION, OR OWNER WITHOUT WRITTEN CONSENT OF THE ARCHITECT.© 2018 L'HEUREUX, PAGE, WERNER, PCNo.DateSubmittal Schedule Submittal 7/18/2021 10:56:24 AMA4.118-053TMPTMPWALL SECTIONSTRADITIONS SUBDIVISIONTOWNHOMES2.20.20213/4" = 1'-0"1WALL SECTION @ ENTRY3/4" = 1'-0"2DEMISING WALL SECTION1 1/2" = 1'-0"3DEMISING WALL @ FND.1 1/2" = 1'-0"4DEMISING WALL AT UPPER FLOOR1 1/2" = 1'-0"5DEMISING WALL AT ROOFUL DESIGN U336 (2-HR. WALL)UL DESIGN U336 (2-HR. WALL)UL DESIGN U336 (2-HR. WALL)HARDSCAPENOTE: PROVIDE FIREBLOCKING VERTICALLYAT FLOOR AND CEILINGS, HORIZONTALLY AT INTERVALS NO GREATER THAN 10'. CONCEALEDSPACES (SOFFIT, DROP CEILINGS, MECH. CHASES,ETC.) BETWEEN VERTICAL AND HORIZONTAL SPACESSHALL HAVE FIREBLOCKING.NOTE: NO PLUMBING OR MECHANICALEQUIPMENT, INCLUDING DUCT OR VENTS,SHALL BE IN RATED UNIT SEPARATION WALLS.NOTE: CONTINUITY OF FIRE-RESISTANCE RATINGSHALL BE CONTINUOUS FROM FOUNDATION TO UNDERSIDEOF ROOF DECKING. FIRE-RESISTANCE RATING SHALL EXTENDTHE FULL LENGTH OF THE WALL OR ASSEMBLY, INCLUDINGEXTENSIONS, PER IRC R302.2.NOTE: CONTINUITY OF FIRE-RESISTANCE RATINGSHALL BE CONTINUOUS FROM FOUNDATION TO UNDERSIDEOF ROOF DECKING. FIRE-RESISTANCE RATING SHALL EXTENDTHE FULL LENGTH OF THE WALL OR ASSEMBLY, INCLUDINGEXTENSIONS, PER IRC R302.2.NOTE: NO VENTS WITHIN 4' OF 2-HOUR FIRE WALLSRevision ScheduleNo. Revision Date1 Revisions per City of Bozeman 5.20.21