From:Lance Lehigh <llehigh@BOZEMAN.NET>
Sent:Friday, February 26, 2021 10:06 AM
To:derek@mad-eng.com; Taylor Lonsdale
Cc:chris@mad-eng.com
Subject:RE: The Flats Site Plan- Peak Hour Trip Generation
Hey Derek,
Thank you for providing this analysis prior to site plan submittal. Based on the anticipated peak hour trips and overall
traffic volume from the proposed Flats development, a Traffic Impact Study (TIS) is not required.
Please provide this email as the formal TIS waiver for The Flats development.
Thanks,
Lance
City of Bozeman MT
Lance Lehigh, PE, CFM | Engineer III
From: derek@mad-eng.com <derek@mad-eng.com>
Sent: Friday, February 26, 2021 8:36 AM
To: Taylor Lonsdale <tlonsdale@BOZEMAN.NET>
Cc: Lance Lehigh <llehigh@BOZEMAN.NET>; chris@mad-eng.com
Subject: The Flats Site Plan- Peak Hour Trip Generation
CAUTION: This email originated from outside of the organization. Do not click links or open attachments unless you recognize the
sender and know the content is safe.
Taylor,
I’m writing in regards to The Flats Site Plan application. The flats is a small development located on Lot 1, Block 16 in a
B2-zoned property in Ph. 2A of the Baxter Meadows Subdivision. The site will utilize a ‘live-work’ concept design, in
which the main floor units will be general commercial space and the second floor will consist of one-bedroom residential
units. There are two buildings in total, each with four commercial units (each approximately 550 sf) and four residential
units (approximately 575 sf).
Using the Institute of Transportation Engineers Trip Generation Manual, 10th Ed. (see attached) the number of trips per
1,000 sf of gross floor area of General Commercial is 2.45. With each commercial unit totaling ~550 sf and a total of
eight units, the total gross floor area is 4,400 sf. This equates to 10.78 trips during the peak hour (4,400sf / 1,000 sf *
2.45 trips per unit).
Using the same resource for residential trip generation, the number of trips per dwelling unit for a mid-rise residential
building with 1st-floor commercial is 0.36. With a total of eight residential units, this equates to 2.88 trips during the
peak hour (8 dwelling units * 0.36 trips per unit).
2
The total peak hour trip generation for the development, including the commercial and residential spaces, equates to
13.66 trips. Due to the low number of trips during peak hour and the relatively small size of the project, we are
requesting a waiver for completing a traffic study.
Thank you,
Derek Dennehy, EI
Madison Engineering, LLC
895 Technology Boulevard, Suite 203
Bozeman, MT 59718
406.586.0262 office
406.586.5740 fax
derek@mad-eng.com
City of Bozeman emails are subject to the Right to Know provisions of Montana’s Constitution (Art. II, Sect. 9) and may
be considered a “public record” pursuant to Title 2, Chpt. 6, Montana Code Annotated. As such, this email, its sender
and receiver, and the contents may be available for public disclosure and will be retained pursuant to the City’s record
retention policies. Emails that contain confidential information such as information related to individual privacy may be
protected from disclosure under law.