Loading...
HomeMy WebLinkAbout9_HouseElectrical_08-20-21c Date:mobile #:phone #:Project No.Drawn by:Date:Scale:GENERAL CONTRACTOR:Revised by: Drafting & Design, Inc.B19-0109-1-3McLay Project - SummerHome330 NO. ROUSEBOZEMAN, MONTANACHRIS MCLAY608-774-2678Tract 2D. Johnston 28 Jan 19 D. Johnston 04 Feb 19 These drawings are licensed for ONE USE ONLY. D. Johnston 16 Jan 19 D. Johnston 25 Jan 19 D. Johnston 08 Mar 19IMPACTDRAFTING & DESIGN, incwww.impactdrafting.com2021 Brentwood Professional Center1195 Stoneridge Dr., Suite 3DBozeman, MT. 59718406-522-5382All rights reserved. All designs, drawings, ideas, and written material contained or described herein are the sole property of IMPACT Drafting & Design Inc. and as such may not be altered, duplicated, used or disclosed without written consent from IMPACT Drafting & Design Inc.scale is correct ifprinted on D-Size paperby IMPACT DraftingNote: IMPACT Drafting & Design Inc. is not responsible for engineering orconstruction. Individual contractors are responsible for meeting codes.IMPACT D. Johnston 03 Apr 19 D. Johnston 16 Sep 20CONTACT/OWNER9 131/4" = 1'Electrical Main Floor House 1st Floor Electrical scale: 1/4" = 1'-0" = arc fault circuit interrupted outlet = smoke detector = wall mounted doorbell = garage door opener = ceiling mounted fan fixture w/ light = duplex outlet, 110 v. ELECTRICAL LEGEND = 220 outlet = switch = ground fault interrupting outlet (GFCI) = ceiling mounted light fixture = 3-way switch = 4-way switch = dimmer switch = wall mounted light fixture = waterproof outlet (GFCI) = switched duplex outlet, 110 v. = in floor duplex outlet, 110 v. = phone / satellite jack (RJ11) = thermostat = flush, wall mounted, stair wash = ceiling mounted fan fixture = computer data port (RJ45) = exhaust fan w/ light = troffer light fixture (led/fluorescent/etc.) = stereo / sound system jack = television cable jack = doorbell button = garage door button or keypad = track lighting = over / under cabinet lighting = carbon monoxide & smoke detector = recessed, ceiling mounted light fixture (led recommended) General Electrical Notes - Smoke detectors to be interconnected and have battery backup - All Smoke Detectors outside Sleeping Rooms and at the top and bottom of stairs must also be a combination carbon monoxide detector - Smoke detectors may not: - be within 36" of a bathroom with a shower or tub - be within 36" of a supply register - be within 36" of the blade tips of a ceiling fan - Ionization Smoke detectors may not be within 20' measured horizontally from permanently installed cooking appliances - Ionization Smoke detectors with alarm silencing may not be within 10' measured horizontally from permanently installed cooking appliances - Photoelectric Smoke detectors may not be within 6' measured horizontally from permanently installed cooking appliances - Electrical outlets in kitchen, garage and laundry to be 48" above floor level - All interior outlets to be AFCI & tamper resistant - All interior recessed lights to be on dimmer switches - All Exterior Lights to be dark-sky compliant - Electrical plans may need to be deviated from by electrician to meet building specific needs either by design or code, however those deviations must be discussed with IMPACT Drafting, Builder, or Client prior to being made. No deviations may violate electrical codes. - Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c. (50Pa), the dwelling unit shall be provide with whole-house ventilation - Bathroom circuiting shall either be: a) a 20 amp dedicated circuit for each bathroom or b) at least one 20 AMP circuit supplying only bathroom outlets House 2nd Floor Electrical scale: 1/4" = 1'-0" Revised by:Date: Additional Revisions D. Johnston 14 Jul 21 D. Johnston 20 Aug 21 D. Johnston 20 Aug 21 D. Johnston 20 Aug 21 D. Johnston 20 Aug 21