HomeMy WebLinkAbout8_BasementElectrical_08-20-21c
Date:mobile #:phone #:Project No.Drawn by:Date:Scale:GENERAL CONTRACTOR:Revised by:
Drafting & Design, Inc.B19-0109-1-3McLay Project - SummerHome330 NO. ROUSEBOZEMAN, MONTANACHRIS MCLAY608-774-2678Tract 2D. Johnston 28 Jan 19
D. Johnston 04 Feb 19
These drawings are licensed for
ONE USE ONLY.
D. Johnston 16 Jan 19
D. Johnston 25 Jan 19
D. Johnston 08 Mar 19IMPACTDRAFTING & DESIGN, incwww.impactdrafting.com2021 Brentwood Professional Center1195 Stoneridge Dr., Suite 3DBozeman, MT. 59718406-522-5382All rights reserved. All designs, drawings, ideas, and
written material contained or described herein are
the sole property of IMPACT Drafting & Design Inc.
and as such may not be altered, duplicated, used or
disclosed without written consent from IMPACT
Drafting & Design Inc.scale is correct ifprinted on D-Size paperby IMPACT DraftingNote: IMPACT Drafting & Design Inc. is not responsible for engineering orconstruction. Individual contractors are responsible for meeting codes.IMPACT
D. Johnston 03 Apr 19
D. Johnston 16 Sep 20CONTACT/OWNER8 131/4" = 1'Basement
Electrical
scale: 1/4" = 1'
Basement Electrical
= arc fault circuit interrupted outlet
= smoke detector
= wall mounted doorbell
= garage door opener
= ceiling mounted fan fixture w/ light
= duplex outlet, 110 v.
ELECTRICAL LEGEND
= 220 outlet
= switch
= ground fault interrupting outlet (GFCI)
= ceiling mounted light fixture
= 3-way switch
= 4-way switch
= dimmer switch
= wall mounted light fixture
= waterproof outlet (GFCI)
= switched duplex outlet, 110 v.
= in floor duplex outlet, 110 v.
= phone / satellite jack (RJ11)
= thermostat
= flush, wall mounted, stair wash
= ceiling mounted fan fixture
= computer data port (RJ45)
= exhaust fan w/ light
= troffer light fixture (led/fluorescent/etc.)
= stereo / sound system jack
= television cable jack
= doorbell button
= garage door button or keypad
= track lighting
= over / under cabinet lighting
= carbon monoxide & smoke detector
= recessed, ceiling mounted light fixture
(led recommended)
General Electrical Notes
- Smoke detectors to be interconnected
and have battery backup
- All Smoke Detectors outside Sleeping
Rooms and at the top and bottom of
stairs must also be a combination carbon
monoxide detector
- Smoke detectors may not:
- be within 36" of a bathroom with a
shower or tub
- be within 36" of a supply register
- be within 36" of the blade tips of a
ceiling fan
- Ionization Smoke detectors may not be
within 20' measured horizontally from
permanently installed cooking appliances
- Ionization Smoke detectors with alarm
silencing may not be within 10' measured
horizontally from permanently installed
cooking appliances
- Photoelectric Smoke detectors may not
be within 6' measured horizontally from
permanently installed cooking appliances
- Electrical outlets in kitchen, garage and
laundry to be 48" above floor level
- All interior outlets to be AFCI & tamper
resistant
- All interior recessed lights to be on
dimmer switches
- All Exterior Lights to be dark-sky
compliant
- Electrical plans may need to be
deviated from by electrician to meet
building specific needs either by design
or code, however those deviations must
be discussed with IMPACT Drafting,
Builder, or Client prior to being made.
No deviations may violate electrical
codes.
- Where the air infiltration rate of a
dwelling unit is less than 5 air changes
per hour when tested with a blower door
at a pressure of 0.2 inch w.c. (50Pa), the
dwelling unit shall be provide with
whole-house ventilation
- Bathroom circuiting shall either be: a)
a 20 amp dedicated circuit for each
bathroom or b) at least one 20 AMP
circuit supplying only bathroom outlets
Revised by:Date:
Additional Revisions
D. Johnston 14 Jul 21
D. Johnston 20 Aug 21
D. Johnston 20 Aug 21
D. Johnston 20 Aug 21
D. Johnston 20 Aug 21