Loading...
HomeMy WebLinkAboutC.3-UTILITY PLAN-061121WS WS WS WS SS S S SS SS SS SS SS SSSSSSSSSS S S S S S SEEE G G G G GGG G GGGEWS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS WS E E E E E E EEEE EEEEEEEEEEEEEEEEEEEEETTTTTTTTTTGGGGGGGGW W W8 SS8 SS8 SS8 SS8 SS8 SS8 SS8 SS8 W8 W8 W8 W8 W8 W8 W8 W8 WEEESSSSWSWSWSGGGTTT11"X17": 1"= 40 ftN GRAPHIC SCALE1 inch = ft.0( IN FEET )10202020HEADWATERSPROJECT NUMBERDRAWING NUMBERDRAWN BY:DATE:2021VERIFY SCALETHESE PRINTS MAY BEREDUCED. LINE BELOWMEASURES ONE INCH ONORIGINAL DRAWING. MODIFY SCALE ACCORDINGLYH:\1204\001\ACAD\SHEETS\C-2-3.dwg Plot Date: 6/16/2021 2:00 PM© HEADWATERS ENGINEERING, INC.REVISION DATE:190 NORTHSTAR LANE, BOZEMAN, MT 59718HEADWATERSMT.NET 406-581-5730PROJECT LOCATIONC-31204.001GALLATIN PARK MIXED USE325 GALLATIN PARK DRIVEUTILITY PLANJRM03/23/2106/11/21BOZEMANMONTANAGALLATIN PARK DRIVE60' R.O.W.3' SIDE SETBACK 3' SIDE SETBACK 3' REAR SETBACKBUILDING 1BBUILDING 2BUILDING 3EXISTING 8" CLASS 51 D.I.P. WATER MAINEXISTING 8" SDR 35 SEWER MAINEXISTING 4" WATER STUB EXISTING 1" WATER SVC EXISTING 4" SWR SVC EXISTING 4" SWR SVC PRIVATE OPENSPACE BLOT 2BLOCK 1LOT 5BLOCK 1PRIVATE OPENSPACE BEXISTING REGIONAL STORM PONDNATURAL SURFACE FLOW OFSTORM WATER TO EXISTINGREGIONAL STORM POND(GALLATIN PARK SUBDIVISION)5'X6" CONCRETE CROSSWALK W/ REBAR 18" O.C.7.0' THICKENED EDGE WALK 7' WALK 5' SIDEWALK5' SIDEWALKEXISTING GAS, POWER& COMMUNICATIONSPROPOSED GAS,POWER &COMMUNICATIONSPROPOSED 1.0"WATER SERVICEW/1.0" METER, L=200'PROPOSED 1.0"WATER SERVICE &METER, L=77'LIVE TAP EXISTING 4"STUB AND INSTALL3/4" WATER SVC &METER, L=36'EXTEND EXISTING 4"SEWER SERVICELINEPROPOSED 4" SEWERSERVICE LINE W/CLEANOUTS, S=2.0%EXISTING 8" CLASS 51 D.I.P. WATER MAINEXISTING 8" SDR 35 SEWER MAINEXISTING 4" WATER STUB EXISTING 1" WATER SVC EXISTING 4" SWR SVC EXISTING 4" SWR SVC PROPOSED 6"SEWER SERVICELINE, S=1.0%5'X6" CONCRETE CROSSWALK W/ REBAR 18" O.C.GALLATIN PARK DRIVETRUNCATED DOME, TYPINSULATE SVCUNDER 5' DEEPFLOW-THRUCURB W/ 1.5' BTMGARAGE DOOR,TYP4" PVC IRR.CONDUIT, TYP100 CF BIORETENTIONAREA, SEE DETAIL ONSHEET C-6PROPOSED BOULDERRETAINING WALL, SEEDETAIL, SHEET C-6SNOW STORAGEAREASNOW STORAGEAREAREPLACE 4"SIDEWALK WITH 6"SIDEWALK W/REBAR18" O.C.EXISTING 5' SIDEWALKREPLACE 4" SIDEWALKWITH 6" SIDEWALKW/REBAR 18" O.C.GARAGE DOOR,TYP6" CONC. W/FIBERMESH IN FRONT OFGARAGE DOORS, TYP.6" CONC. W/FIBERMESH IN FRONT OFGARAGE DOORS, TYP.MOUNTHANDICAPPARKING SIGNSON BUILDING6" SIDEWALKCURB6" SIDEWALKCURBGARAGE DOOR,TYPEXISTING 5' SIDEWALKACCESSIBLEPARKINGSTRIPINGLEGENDUNDERGROUND ELECTRICSEWER PIPEWATER SERVICE LINEEASEMENT OR SETBACK AS LABELEDUNDERGROUND GAS LINEUNDERGROUND COMMUNICATION LINEEXISTING CONTOURS 0.5' INTERVAL4" IRRIGATION CONDUITPROPOSED SIDEWALKEXISTING CURB AND SIDEWALKCONSTRUCTION NOTES:1. ALL ISLANDS ARE 8' WIDE MINIMUM.2. PARKING SPACES ARE 9' MIN. WIDTH.3. DRIVE AISLES ARE 24' MIN. WIDTH.4. SEE GEOTECHNICAL REPORT FOR PARKING LOT SECTION DEPTHS.5. CURB RADII ARE TO BE 3' UNLESS OTHERWISE NOTED.6. ALL INFRASTRUCTURE SHALL BE INSTALLED IN ACCORDANCE WITH THELATEST EDITION OF THE MONTANA PUBLIC WORKS.7. THE CONTRACTOR SHALL CONTACT ONE CALL @ 1-800-424-5555 FOR ONSITEUTILITY LOCATION. ALL UTILITIES SHALL BE MARKED BEFORE DIGGING.UTILITIES SHOWN ARE FOR PLANNING PURPOSES ONLY.8. THE CONTRACTOR SHALL NOTIFY THE BOZEMAN WATER & SEWERDEPARTMENT A MINIMUM OF 24 HOURS PRIOR TO BEGINNING ANY WORK.9. CONSTRUCTED SIDEWALKS SHALL MEET ALL SPECIFICATIONS ANDREQUIREMENTS OF THE CITY OF BOZEMAN SIDEWALK POLICY.PROPOSED ASPHALTREMOVE AND REPLACEREMOVE & REPLACECURB W/LAYDOWNPROPERTY BOUNDARY PROPERTY BOUNDARY PROPERTY BOUNDARYREMOVE & REPLACECURB W/LAYDOWN12"X8' SIDEWALK CHASE12"X8' SIDEWALK CHASEBUILDING 1APROPOSED ASPHALTREMOVE AND REPLACECONNECT TO EXISTING1" COPPER WTR SVC @CURB STOPINSTALLREDUCER TO 1"UNDER ASPHALTINSTALL 1.5" WATERSERVICE W/1.0"METER, L=250'PROPOSED 6" SEWERSERVICE LINE, S=1.0%SNOW STORAGEAREATRASH ENCLOSURE,SEE DETAIL ON ARCH.DRAWINGS.SEWERCLEANOUTSEXISTING 12' PUE PERPLAT J-300EXISTING FIREHYDRANT 3/4" METER (NEEDS58" OF ROOM) 1" METER (NEEDS58" OF ROOM) 1" METER (NEEDS58" OF ROOM)1" METER (NEEDS58" OF ROOM)ELECTRIC & GASMETERSELECTRIC & GASMETERSELECTRIC & GASMETERSELECTRIC & GASMETERS8.5'7.2'3'-2"16.5'3'-4"16'-7"3'-4"16'-7"BUILDINGFOOTPRINT, TYPAC UNITSAC UNITSAC UNITSAC UNITS210.06'210.02'164.93'55.02'55.03'165.05LIVE TAP 8" WATERW/1.5" SERVICECONNECT TOEXISTING 1"COPPER WTR SVC@ CURB STOPINSTALL CURB STOP9' BEHIND SIDEWALKINSTALL CURB STOP9' BEHIND SIDEWALK4" LINE IS 5.5"ABOVE THE 6" LINEAT CROSSINGINSTALL CONTECH CDS HYDRODYNAMIC(CDS2015-4) SEPARATOR PER SHEET C-7.INSTALL 7' OF 8" PVC PIPEW/CONCRETE COLLAR ONEND, S=0.5%EXISTING POND OUTLETSTRUCTURE