Loading...
HomeMy WebLinkAboutA1.1 FLOOR PLANS 07-06-20211SHEET TITLE Designed by: SHEET 2 OF 12 A1.1 Built by: Ph: 541.550.9389 Em. openroaddesignco@gmail.com Web. myopenroaddesign.com PROJECT NO: DATE: DRAWN BY: COPYRIGHT: Jeff Warwick 05.03.2021 202022-HL Open Road Design BIMcloud: openroaddesign - BIMcloud as a Service/Fallon Plans/Highland/HighlandNorton Ranch Homes:FLOOR PLANSHighland PlanPhone: 541-728-0378www.Nortonranchhomes.comArea Calculations: 1st Floor 700 2nd Floor 930 Total Conditioned 1,630 sq. ft. Garage 485 Front Porch 50 Dining Rm Patio 2016 RISERS (7 39/64")101 102 104102103 105106101103 108109106104 105 107DWRF SD 8 A7.1 9 A7.1 10 A7.1 10 A7.1 10 A7.1 21'-0"61'-0"59'-0"1'-8"8'-8"1'-8"7'-10"1'-2"2'-0"6'-0"14'-0"8'-6"30'-6"3'-0"3'-0"6'-6"7'-6"4'-3"4'-3"8'-0"18'-0"33'-0"21'-0" 2'-0"4'-8"2'-0"3'-11"3'-11" 10'-6"10'-6"3'-4 1/8"10'-1 3/8"10'-0"2'-4"3'-8"8'-8 1/2"2'-5 1/2"7'-0 1/2"2'-9 1/2" 8'-0"4'-0" 1 A3.1 2 A3.2 1 A3.2 1 A8.1 4 A8.1 3 A8.1 1 hr wall Concrete slab, slope to drain 20 min. door w/ self closing hinges Water Meter location Code Compliant Railing Furnace by others. Provide condensate line and drain to outside W-01 W-01 W-04 W-03 W-03 W-03 W-03 W-03 W-02W-02 W-03 6x6 Vert. Post Bracketed columns 6x Beam Conc. slab Bracketed columns 6x Beam Conc. slab W-01 Area of hanging bike storage - Rubbermaid Fasttrack 7.5 in. Bike Rack - verify with contractor Water heater fastened to wall per P2801.8. Provide overflow drain pan & drain to outside EgressEgressGarage Mechanical Mudroom Closet Kitchen Dining Living Rm Entry W/C Stair 1 A4.1 1 A4.1 Elec. Meter - See landscape plans for screening Gas Meter (Below) 201 203205204207 206 209208210202 203 202206207 209208 205201 204 DW SD SDSD SD 1 A3.1 1 A3.2 2 A3.1 1 A8.1 3 A8.1 2 A8.1 50'-0"21'-0"50'-0"21'-0" 10'-0"11'-0" 5'-0"5'-0"5'-6"5'-6"22'-0"8'-6"14'-0"5'-6"5'-6"10'-0"5'-6"6'-0"44'-0"6'-6"19'-0"13'-0"5'-6"6'-9"3'-6 3/4"3'-6 3/4"7'-1 1/2" 9'-9 1/2"4'-1" 3'-5 1/2"4'-4"13'-2 1/2"6'-5 1/2"12'-1"5'-6 1/2"5'-4 1/2"7'-9 1/2"2'-4 1/2"10'-4 1/2"1 A4.1 1 A4.1 W-01 W-03 W-03 W-03 W-02 W-02 W-03 W-01 W-01W-01 W-01 W-03 W-03 Dryer vent to run through walls & ceilings to attic and terminate @ roof. Line not to exceed 35' w/ 5' added for each elbow W-03 W-02 EgressEgressEgressEgressM. Bedroom W.I.C. M. Bath Bath 1 Laundry RoomBonus Room Bedroom 1 Bedroom 2 Stair Hall Element ID W-01 W-02 W-03 W-04 2D Plan Preview Fire Rating NA NA NA 1 HR R-Value R-21 Batts NA NA R-21 Batts Assembly list Siding per elevations over wrb over sheathing per structural over 2x6 KD DF #2 Studs @ 16" o.c. w/ R-21 batt insulatino - 1/2" gyp interior, finish TBD 1/2" Gyp bd each side over 2x6 KD DF #2 studs @ 16" o.c. 1/2" Gyp bd each side over 2x4 KD DF #2 studs @ 16" o.c. 5/8" Type 'x' gyp over 2x6 KD DF #2 Studs @ 16" o.c. w/ R-21 batt insulatino - 1/2" gyp interior, finish TBD WALL TYPE INDEX SCALE: 1/4" = 1'-0"1 First Floor 0 2'4'8'SCALE: 1/4" = 1'-0"2 Second Floor 0 2'4'8' Stair Notes: 1) Maximum rise is 8.25" and min. run is 9", measuring from the nosing projection. where there is no nosing, the minimum run is 10" 2) Min. headroom is 6'-8" 3) Min. stair width is 36" 4) The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8". The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8" Handrail Notes: 1) Provide handrail on the inside wall of stairs as per applicable code 2) Handrails and extensions shall be 34-38" above nosing of treads and be continuous. 3) The handgrip portion of the handrails shall not be less than 1.25" nor be more than 2" in cross sectional dimension. See section R311.7.8.3 for alternatives 4) Handrails projecting from walls shall have at least 1.5" between the wall and the handrail 5) Ends of handrails shall be returned or shall have rounded terminations or bends General Code Notes: 1) NEC250.50 Verify location of concrete encased electrical services on foundation plan 2) IRC 611.5.4 Vertical concrete reinforcement is to be secured in place for inspeciton prior to pouring of concrete footings and foundations on foundation plan 3) R207.8 Flashing in following locations: a) Top of windows & doors. b) at intersections of chimneys, masonry, and wood with frame or stucco walls. c) Under and at ends of masonry, wood, or metal copings or sills. d) Continuously above all projecting wood trim. e) Where exterior porches, decks or stairs attach to wall or floor assemblies of wood frame construction. f) At wall and roof intersections. g) At built-in gutters. h) Between concrete porches/decks and wall sheathing 4) This project to comply with the 2018 IRC, 2012 UPC, 2012 IMC, and 2014 NEC or other applicable local and national codes