HomeMy WebLinkAboutA1.1 FLOOR PLANS 07-06-20211SHEET TITLE
Designed by:
SHEET 2 OF 12
A1.1
Built by:
Ph: 541.550.9389
Em. openroaddesignco@gmail.com
Web. myopenroaddesign.com
PROJECT NO:
DATE:
DRAWN BY:
COPYRIGHT:
Jeff Warwick
05.03.2021
202022-HL
Open Road Design
BIMcloud: openroaddesign - BIMcloud as a Service/Fallon Plans/Highland/HighlandNorton Ranch Homes:FLOOR PLANSHighland PlanPhone: 541-728-0378www.Nortonranchhomes.comArea Calculations:
1st Floor 700
2nd Floor 930
Total Conditioned 1,630 sq. ft.
Garage 485
Front Porch 50
Dining Rm Patio 2016 RISERS (7 39/64")101 102 104102103
105106101103
108109106104
105
107DWRF
SD
8
A7.1
9
A7.1
10
A7.1
10
A7.1
10
A7.1
21'-0"61'-0"59'-0"1'-8"8'-8"1'-8"7'-10"1'-2"2'-0"6'-0"14'-0"8'-6"30'-6"3'-0"3'-0"6'-6"7'-6"4'-3"4'-3"8'-0"18'-0"33'-0"21'-0"
2'-0"4'-8"2'-0"3'-11"3'-11"
10'-6"10'-6"3'-4 1/8"10'-1 3/8"10'-0"2'-4"3'-8"8'-8 1/2"2'-5 1/2"7'-0 1/2"2'-9 1/2"
8'-0"4'-0"
1
A3.1
2
A3.2
1
A3.2
1
A8.1
4
A8.1
3
A8.1
1 hr wall
Concrete slab, slope to drain
20 min. door w/
self closing hinges
Water Meter location
Code
Compliant
Railing
Furnace by others. Provide
condensate line and drain
to outside
W-01
W-01
W-04
W-03
W-03
W-03
W-03
W-03
W-02W-02
W-03
6x6 Vert. Post
Bracketed columns
6x Beam
Conc. slab
Bracketed
columns
6x Beam
Conc. slab
W-01
Area of hanging bike storage
- Rubbermaid Fasttrack 7.5
in. Bike Rack - verify with
contractor
Water heater fastened to wall
per P2801.8. Provide overflow
drain pan & drain to outside
EgressEgressGarage
Mechanical
Mudroom Closet
Kitchen
Dining
Living Rm
Entry
W/C
Stair
1
A4.1
1
A4.1
Elec. Meter - See
landscape plans for
screening
Gas Meter (Below)
201 203205204207 206
209208210202
203 202206207 209208
205201
204
DW
SD
SDSD
SD
1
A3.1
1
A3.2
2
A3.1
1
A8.1
3
A8.1
2
A8.1
50'-0"21'-0"50'-0"21'-0"
10'-0"11'-0"
5'-0"5'-0"5'-6"5'-6"22'-0"8'-6"14'-0"5'-6"5'-6"10'-0"5'-6"6'-0"44'-0"6'-6"19'-0"13'-0"5'-6"6'-9"3'-6 3/4"3'-6 3/4"7'-1 1/2"
9'-9 1/2"4'-1"
3'-5 1/2"4'-4"13'-2 1/2"6'-5 1/2"12'-1"5'-6 1/2"5'-4 1/2"7'-9 1/2"2'-4 1/2"10'-4 1/2"1
A4.1
1
A4.1
W-01
W-03
W-03
W-03
W-02
W-02
W-03
W-01
W-01W-01
W-01
W-03
W-03
Dryer vent to run through walls
& ceilings to attic and terminate
@ roof. Line not to exceed 35'
w/ 5' added for each elbow
W-03
W-02 EgressEgressEgressEgressM. Bedroom
W.I.C.
M. Bath
Bath 1
Laundry RoomBonus Room
Bedroom 1
Bedroom 2
Stair Hall
Element ID W-01 W-02 W-03 W-04
2D Plan
Preview
Fire Rating NA NA NA 1 HR
R-Value R-21 Batts NA NA R-21 Batts
Assembly
list
Siding per elevations over
wrb over sheathing per
structural over 2x6 KD DF
#2 Studs @ 16" o.c. w/ R-21
batt insulatino - 1/2" gyp
interior, finish TBD
1/2" Gyp bd each side over
2x6 KD DF #2 studs @ 16"
o.c.
1/2" Gyp bd each side over
2x4 KD DF #2 studs @ 16"
o.c.
5/8" Type 'x' gyp over 2x6
KD DF #2 Studs @ 16" o.c.
w/ R-21 batt insulatino -
1/2" gyp interior, finish TBD
WALL TYPE INDEX
SCALE: 1/4" = 1'-0"1 First Floor
0 2'4'8'SCALE: 1/4" = 1'-0"2 Second Floor
0 2'4'8'
Stair Notes:
1) Maximum rise is 8.25" and min. run is 9", measuring from the nosing projection.
where there is no nosing, the minimum run is 10"
2) Min. headroom is 6'-8"
3) Min. stair width is 36"
4) The greatest riser height within any flight of stairs shall not exceed the smallest by
more than 3/8". The greatest tread depth within any flight of stairs shall not exceed the
smallest by more than 3/8"
Handrail Notes:
1) Provide handrail on the inside wall of stairs as per applicable code
2) Handrails and extensions shall be 34-38" above nosing of treads and be continuous.
3) The handgrip portion of the handrails shall not be less than 1.25" nor be more than 2"
in cross sectional dimension. See section R311.7.8.3 for alternatives
4) Handrails projecting from walls shall have at least 1.5" between the wall and the handrail
5) Ends of handrails shall be returned or shall have rounded terminations or bends
General Code Notes:
1) NEC250.50 Verify location of concrete encased electrical services on foundation plan
2) IRC 611.5.4 Vertical concrete reinforcement is to be secured in place for inspeciton
prior to pouring of concrete footings and foundations on foundation plan
3) R207.8 Flashing in following locations: a) Top of windows & doors. b) at intersections of chimneys,
masonry, and wood with frame or stucco walls. c) Under and at ends of masonry, wood, or metal
copings or sills. d) Continuously above all projecting wood trim. e) Where exterior porches, decks or
stairs attach to wall or floor assemblies of wood frame construction. f) At wall and roof intersections.
g) At built-in gutters. h) Between concrete porches/decks and wall sheathing
4) This project to comply with the 2018 IRC, 2012 UPC, 2012 IMC, and 2014 NEC or other applicable
local and national codes