Open Road DesignNorton Ranch Homes:Floor PlansTHE BOULDERArea Calculations:
FIRST FLOOR - 546 SF
SECOND FLOOR - 684 SF
TOTAL HEATED = 1230 SF
GARAGE - 473 SF Phone: 541-728-0378www.Nortonranchhomes.comUP15 RISERS (7 5/16")108107106104101 102101 103104105102
103
105105SD
1
A4.1
5
A6.3
3
A3.2
3
A3.2
21'-0"26'-0"22'-6"2'-0"48'-6"7'-3"7'-11"3'-7"2'-3"
2'-0"21'-0"6'-10"8'-0"5'-4"5'-10"9'-6"13'-0"26'-0"22'-6"48'-6"10'-6"10'-6"4'-6 1/2"13'-8"7'-9 1/2"14'-6"1'-7"3'-10 3/4"
3'-6"
1
A8.1
2
A8.1
3
A8.1
4
A8.1
STORAGE/ WATER
METER LOCATION
1 Hr. Assembly
Type 'x' Gyp Board
Note: penetrations in fire
rated assemblies shall be
protected as req'd by
CRC Section R302.4
Type 5/8" 'x' Gyp Ceiling
1 hr fire rated assembly
20 min. rated door
4" Conc. slab per
structural. Slope to
drain, ±1/8:12
W-1W-1 W-2W-2W-2W-1
W-1W-1
Egress
EgressArea of hanging bike storage -
Rubbermaid Fasttrack 7.5 in. Bike Rack -
verify with contractor
(2) CAR GARAGE
+/- 9.5' CEILING
KITCHEN
9' CEILING
LIVING ROOM
9' CEILING
DINING
9' CEILING
FRONT PORCH
COVERED
BATH
GARAGE
BATH
LIVING RM
KITCHEN/DINNING
1
A4.1
1
A4.1
5'-8"15'-10"4'-6"9'-6"13'-0"1
A3.1
4
A3.1
2
A3.2
1
A3.22
3 A6.1
1/2 Gyp. under stair
Elec. Meter - See
landscape plans for
screening
Gas Meter (Below)
DOWN
208207201
202 203204205
204
201
203 202206205206 204209
SD
SD
SD
6
A6.3
1
A8.1
2
A8.1
3
A8.1
4
A8.1
7'-3"7'-3"4'-3"2'-3"
14'-6"6'-6"
21'-0"22'-0"17'-6"39'-6"18'-0"6'-4"10'-8"5'-0"12'-6"5'-0"5'-0"13'-4"13'-9"7'-5"34'-6"5'-3 1/2"2'-0"7'-0 1/8"12'-2 7/8"5'-6 3/4"7'-3 1/2"3'-9 1/2"
3'-6"3'-3 1/4"5'-4"8'-6"9'-3 1/2"
3'-0"11'-8"6'-4"
11'-9 1/2"13'-10"1
A4.1
1
A4.1
Fiberglass Shower
pan w/ optional tile
surround
W-1 W-1W-2W-2W-2W-2W-2W-1W-1W-1
W-2
W-1W-2 W-2Egress
Egress
Furnace by others. Provide
condensate line and drain
to outside
Water heater fastened to wall
per P2801.8. Provide overflow
drain pan & drain to outside
MASTER BEDROOM
Vaulted
BEDROOM #2
9' CEILING
MECH
W/I CLOSET
FULL BATH
M. BATH
BEDROOM 2
FULL BATH
LAUNDRY
HALL WAY
MECH
M. BEDROOM
M. BATH
<House Number>
STAIR
LAUNDRY
9' CEILING
1
A3.1
4
A3.1
2
A3.2
1
A3.2
SCALE: 1/4" = 1'-0"
1 First Floor
0 2'4'8'SCALE: 1/4" = 1'-0"
2 Second Floor
0 2'4'8'
Stair Notes:
1) Maximum rise is 7.75" and min. run is 9", measuring from the nosing projection.
where there is no nosing, the minimum run is 10"
2) Min. headroom is 6'-8"
3) Min. stair width is 36"
4) The greatest riser height within any flight of stairs shall not exceed the smallest by
more than 3/8". The greatest tread depth within any flight of stairs shall not exceed the
smallest by more than 3/8"
Handrail Notes:
1) Provide handrail on the inside wall of stairs as per applicable code
2) Handrails and extensions shall be 34-38" above nosing of treads and be continuous.
3) The handgrip portion of the handrails shall not be less than 1.25" nor be more than 2"
in cross sectional dimension. See section R311.7.8.3 for alternatives
4) Handrails projecting from walls shall have at least 1.5" between the wall and the handrail
5) Ends of handrails shall be returned or shall have rounded terminations or bends
General Code Notes:
1) NEC250.50 Verify location of concrete encased electrical services on foundation plan
2) IRC 611.5.4 Vertical concrete reinforcement is to be secured in place for inspection
prior to pouring of concrete footings and foundations on foundation plan
3) R207.8 Flashing in following locations: a) Top of windows & doors. b) at intersections of chimneys,
masonry, and wood with frame or stucco walls. c) Under and at ends of masonry, wood, or metal
copings or sills. d) Continuously above all projecting wood trim. e) Where exterior porches, decks or
stairs attach to wall or floor assemblies of wood frame construction. f) At wall and roof intersections.
g) At built-in gutters. h) Between concrete porches/decks and wall sheathing
4) This project to comply with the 2018 IRC, 2012 UPC, 2012 IMC, and 2014 NEC or other applicable
local and national codes