HomeMy WebLinkAbout10_D3_STORMWATER CHAMBER DETAILS_05082021.pdf A - REINFORCING TABLE TEMPORARY COVER FOR ACCESS CASTING TO BE CONSTRUCTION LOADS PROVIDED AND INSTALLED 0 CMP "BEARING 0 BY CONTRACTOR% 0 . A 0 B REINFORCING PRESSURE HEIGHT RISER FINISHED (PSF) OF lull_ GRADE COVER ill N EW 2,410 a a a a 24" 4,X4, 26' #5 @ 12"OCEW 1,780 'I�IE=111-1 c 00 �1�I G III III 0 4'-6" #5 @ 12"OCEW 2,120 -1lli 1 - ° 4 a 30 4'-6"X 4'-6" 32 #5 @ 12"OCEW 1,530 A ra �1i1 GASKET MATERIAL ¢ 5 X 5' S #5 @ 10"OCEW 1,350 36" 38" CMP RISER CONSTRUCTION LOADS SUFFICIENT TO PREVENT a -- SLAB FROM BEARING ON W 42r, 5'-6"5'-6" #5 @ 10"OCEW 1,720 RISER TO BE PROVIDED BY FOR TEMPORARY CONSTRUCTION VEHICLE LOADS,AN EXTRAAMOUNT OF COMPACTED COVER MAY BE REQUIRED OVER o_ X 5'-6" 44 #5 @ 9"OCEW 1,210 THE TOP OF THE PIPE. THE HEIGHT-OF-COVER SHALL MEET THE MINIMUM REQUIREMENTS SHOWN IN THE TABLE BELOW. CONTRACTOR. OB 11"TYP. ¢ fn THE USE OF HEAVY CONSTRUCTION EQUIPMENT NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED 0 6' 6' #5 @ 9"OCEW 1,600 GRADE COVER MINIMUMS FOR NORMAL HIGHWAY TRAFFIC. 48 X 6' 50 #5 @ 8"OCEW 1,100 SECTION VIEW PIPE SPAN, AXLE LOADS (kips) -ASSUMED SOIL BEARING CAPACITY INCHES 18-50 1 50-75 1 75-110 110-150 MINIMUM COVER(FT) o OA A 12-42 2.0 2.5 3.0 3.0 AOG6Q OB 48-72 3.0 3.0 3.5 4.0 #4 DIAGONAL TRIM #4 DIAGONAL TRIM BAR(TYP.4 PLACES), 78-120 3.0 3.5 4.0 4.0 BAR(TYP.4 PLACES), SEE NOTE 7. 126-144 3.5 4.0 4.5 4.5 SEE NOTE 7. 2"COVER 'MINIMUM COVER MAY VARY,DEPENDING ON LOCAL CONDITIONS. THE CONTRACTOR MUST PROVIDE THE ADDITIONAL f (TYP) COVER REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE MAINTAINED CONSTRUCTION ROADWAY SURFACE. CONSTRUCTION LOADING DIAGRAM o0-1e� SCALE: N.T.S. a OPENING IN PROTECTION SPECIFICATION FOR DESIGNED DETENTION SYSTEM: SLAB FOR OPENING IN CASTING PROTECTION SCOPE PIPE SLAB FOR THIS SPECIFICATION COVERS THE MANUFACTURE AND INSTALLATION OF THE PIPE SHALL BE MANUFACTURED IN ACCORDANCE TO THE APPLICABLE CASTING THE DESIGNED DETENTION SYSTEM DETAILED IN THE PROJECT PLANS. REQUIREMENTS LISTED BELOW: MATERIAL ALUMINIZED TYPE 2: AASHTO M-36 OR ASTM A-760 INTERRUPTED BAR THE MATERIAL SHALL CONFORM TO THE APPLICABLE REQUIREMENTS REPLACEMENT,SEE LISTED BELOW: GALVANIZED: AASHTO M-36 OR ASTM A-760 NOTE 6. STANDARD STANDARD INTERRUPTED BAR ALUMINIZED TYPE 2 STEEL COILS SHALL CONFORM TO THE APPMEY'AHMECOATED: AASHTO M-245 OR ASTM A-762 REINFORCING, REINFORCING, OB REQUIREMENTS OF AASHTO M-274 OR ASTM A-92. SEE TABLE SEE TABLE REPLACEMENT, ALUMINUM: AASHTO M-196 ORASTM B-745 SEE NOTE 6. THE REQUIRVANIZE STEEL OFAASCOIL -218O ASTMCONF A- 29. APPLICABLE ROUND OPTION PLAN VIEW SQUARE OPTION PLAN VIEW REQUIREMENTS OF AASHTO M-218 OR ASTM A-929. HANDLING AND ASSEMBLY SHALL BE IN ACCORDANCE WITH NCSP'S(NATIONAL CORRUGATED STEEL THE POLYMER COATED STEEL COILS SHALL CONFORM TO THE Af#R2t£AB6DCIATION)FOR ALUMINIZED TYPE 2,GALVANIZED OR POLYMER NOTES: REQUIREMENTS OF AASHTO M-246 OR ASTM A-742. COATED STEEL. SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS FORALUMINUM PIPE. 1. DESIGN IN ACCORDANCE WITH AASHTO,17th EDITION. 7. TRIM OPENING WITH DIAGONAL#4 BARS,EXTEND THE ALUMINUM COILS SHALL CONFORM TO THE APPLICABLE REQUIREMENTS BARS A MINIMUM OF 12"BEYOND OPENING,BEND OF AASHTO M-197 OR ASTM B-744. INSTALLATION 2. DESIGN LOAD HS25. BARS AS REQUIRED TO MAINTAIN BAR COVER. SHALL BE IN ACCORDANCE WITH AASHTO STANDARD SPECIFICATIONS FOR CONSTRUCTION LOADS HIGHWAY BRIDGES,SECTION 26,DIVISION II DIVISION II OR ASTM A-798(FOR 3. EARTH COVER=V MAX. 8. PROTECTION SLAB AND ALL MATERIALS TO BE CONSTRUCTION LOADS MAYBE HIGHER THAN FINAL LOADS.FOLLOW THE ALUMINIZED TYPE 2,GALVANIZED OR POLYMER COATED STEEL)OR ASTM PROVIDED AND INSTALLED BY CONTRACTOR. MANUFACTURER'S OR NCSPA GUIDELINES. B-788(FOR ALUMINUM PIPE)AND IN CONFORMANCE WITH THE PROJECT 4. CONCRETE STRENGTH=3,500 psi PLANS AND SPECIFICATIONS.IF THERE ARE ANY INCONSISTENCIES OR 9. DETAIL DESIGN BY DELTA ENGINEERING,BINGHAMTON,NY. CONFLICTS THE CONTRACTOR SHOULD DISCUSS AND RESOLVE WITH THE 5. REINFORCING STEEL=ASTM A615,GRADE 60. SITE ENGINEER. NOTE: 6. PROVIDE ADDITIONAL REINFORCING AROUND MANHOLE CAP DETAIL THESE DRAWINGS ARE FOR CONCEPTUAL IT IS ALWAYS THE RESPONSIBILITY OF THE CONTRACTOR TO FOLLOW OSHA OPENINGS EQUAL TO THE BARS INTERRUPTED, PURPOSESAND DO NOT REFLECTANY LOCAL GUIDELINES FOR SAFE PRACTICES. HALF EACH SIDE. ADDITIONAL BARS TO BE IN SCALE: N.T.S. 3 PREFERENCES OR REGULATIONS.PLEASE THE SAME PLANE. o CONTACT YOUR LOCAL CONTECH REP FOR >I MODIFICATIONS. d The design and Information shown on thus drawing Is provided PROJECT No.: SEO.No.: DATE: as a service to the project owner,engineer and wntracto'by Contech Engines d Solutions LLC("Contech').Neither this A�I�_\ITC^Ll 4611 7387 5/3/2021 F drawing,nor any pan thereof,may be used,reproduced or C�ii NTECH \\� ` �� DY07387 NORTH 3RD AVENUE DUPLEXES g modified In any manner without the poor written consent of � � ��.,��` `�r� DESIGNED: �DRAWN: Contech.Failure to comply is done at the user's own risk and INFILTRATION CHAMBER Contech expressly tlisclaims any liability or responsibility for ENGINEERED SOLUTIONS LLC CMP DETENTION SYSTEMS DYO DYO Fsu n use. r If discre cies between the supplied information which www.ContechES.com Bozeman, MT CHECKE DYO ROV DVO Pan PP Pon CONTECH hedrawin is based and actual fieldcenditiensars-countered DYODS g 9025CentrePointeDr.,Suite400, West Chester,OH DETENTION SYSTEM SHEET D3 d as site work progresses,these discrepancies must be reported Ld to Contech immediately for reevaluation of the design.Contech W accepts no liability for tlesigns basetl on missing,inwmplete or 800-338-1122 513-645-7000 513-645-7993 FAX DRAWING inaccumte information supplied!b ethers. DATE REVISION DESCRIPTION BY