HomeMy WebLinkAboutAA5Interior&Elec._052521WHRefrigeratorELECTRICAL KEYSR4SCONCES 4" LED SURFACE MOUNTWHITE TRIMCMCEILING MOUNTEDF/LBATH FAN/LIGHTVERIFY MODEL WITH ARCH. PRIOR TO ORDERINGSDSMOKE /CARBON MONOXIDE DETECTORSSWITCHSTANDARD WHITE SWITCHES, CHECK 3 WAY LOCATIONSC/DOUTLETCABLE/DATAPHPHONEPPENDANTS ELECTRICAL NOTESSEE ELECTRICAL NOTES1. PROVIDE A CARBON MONOXIDE DETECTOR AT EACH FLOOR. BASEMENT CARBON MONOXIDE DETECTOR TO BE LOCATED IN HALLWAY.2. ALL RECEPTACLES TO BE TAMPER RESISTANT.3. EXTERIOR RECEPTACLES TO BE WEATHER RESISTANT.4. PROVIDE ARC FAULT PROTECTION FOR ALL OUTLETS.5. GFCI OUTLETS TO BE PROVIDED IN GARAGE, BATHROOMS, OUTDOORS, KITCHEN, LAUNDRY ROOM, AND WITHIN 6' OF A SINK.6. BATHROOM CIRCUITING SHALL BE EITHER a)A 20 AMPERE CIRCUIT DEDICATED TO EACH BATHROOM, OR b) AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS.7. SMOKE ALARMS MUST BE INTERCONNECTED AND HAVE BATTERY BACK UP. WHEN ALARM ACTUATES, ALL ALARMS SHALL ACTUATE. 8. SMOKE ALARM LOCATION SHALL NOT ENCROACH WITHIN 36" OF A DOOR SERVING A BATHROOM WITH TUB OR SHOWER, HORIZONTAL PATH OF SUPPLY REGISTERS FOR THE MECHANICAL SYSTEM, HORIZONTAL PATH FROM TIP OF CEILING FAN BLADES, OR 10' OF A COOKING SURFACE.9. SPACING FOR RECEPTACLES SHALL NOT BE MORE THAN 6' MEASURED HORIZONTALLY ALONG THE FLOOR LINE.10. ALL LUMINARIES LOCATED IN WET OR DAMP LOCATIONS SHALL BE MARKED 'SUITABLE FOR WET LOCATIONS'. DAMP LOCATIONS MAY BE LABELED 'SUITABLE FOR DAMP LOCATIONS'.11. GARAGES SHALL HAVE BRANCH CIRCUIT SUPPLY, AT LEAST ONE RECEPTACLE, AND SHALL NOT SUPPLY POWER TO OUTLETS OUTSIDE THE GARAGE. MINIMUM ONE RECEPTACLE PER PARKING SPACE.12. AT LEAST ONE RECEPTACLE SHALL BE INSTALLED IN THE KITCHEN ISLAND.13. PROVIDE AT LEAST 30" OR WIDTH OF THE ELECTRICAL EQUIPMENT OF WORKING SPACE, WHICH EVER IS GREATER. CLEAR HEIGHT SHALL BE FROM FINISHED FLOOR TO 6'-6" ABOVE FINISHED FLOOR. THIS CLEAR FLOOR SPACE SHALL NOT BE USED FOR STORAGE.FBATH FAN (NO LIGHT)VERIFY MODEL WITH ARCH. PRIOR TO ORDERINGCOMBINATION DETECTOR1A42A4SORANGE DASHED LINE INDICATES LED STRIP LIGHTING ATTACHED TO BOTTOM FLANGE OF STEEL BEAM -SEE DETAILSSSSDFSSSSSGFIGFIC/D1' - 6"2' - 0"1' - 9"MICRO.2' - 0"1' - 6"2' - 0"1' - 10 1/2"1' - 6"2' - 9"2' - 9"1' - 6"1' - 4 1/2"SCONCE LOCATION1' - 4"2' - 5"0' - 10"Project CodeDate111 South Grand, Studio 107c , Bozeman, MT 59715 ph. 406.868.3917A5INTERIOR & ELEC.KDS418 WEST STORY5.25.21BOZEMAN, MT, 597151/4" = 1'-0"3Electrical NotesREVISIONSNUMBERDESCRIPTIONDATE1/4" = 1'-0"1top of parapet wall1/2" = 1'-0"2Elevation 1 - a1/2" = 1'-0"4Elevation 2 - c1/2" = 1'-0"5Elevation 2 - d1/2" = 1'-0"6Elevation 2 - aNOT FOR CONSTRUCTIONDESIGN DEVELOPMENTDRAWINGS