HomeMy WebLinkAboutCoverSheet&Index_6.25.21 11 1i 1 1 Name Elevation N 1 A101 SIM 1 / A101 1 View Name 1/8" = 1’−0" DRAWING TITLE GRAPHIC SYMBOLS BUILDING SECTION 1 A101 SIM DETAIL SECTION 1 Ref View Name EXTERIOR ELEVATION 1 Ref View Name INTERIOR ELEVATION DETAIL CALLOUT A101 1 SIM ROOM NAME 101 ROOM NAME & NUMBER STRUCTURAL GRID REVISION CLOUD & NUMBER 1 DOOR NUMBER/TYPE WINDOW NUMBER/TYPE BENCHMARK ELEVATION VIEW REFERENCE EXISTING CONTOUR NORTH ARROW 1. DRAWINGS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE TH XCLUSIVE PROPERTY OF THIS DESIGNER WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED AND CONSTRUCTED OR NOT. THESE DOCUMENTS ARE NOT TO BE REPRODUCED IN ANY FORM AND THEY ARE NOT TO BE USED BY THE PROJECT OWNER NOR ANY OTHER ENTITY ON ANY OTHER PROJECTS OR FOR ANY EXTENSIONS OR ADDITIONS OR ALTERATIONS TO THE ORIGINAL PROJECT EXCEPT BY WRITTEN AUTHORIZATION AND PERMISSION FROM AND AGREEMENT WITH THIS DESIGNER. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AT THE JOB SITE AND SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES, OMISSIONS, AND/OR CONFLICTS BEFORE PROCEEDING WITH TH WORK. 3. CONTRACTOR MUST COMPLY WITH THE RULES AND REGULATIONS OF AGENCIES HAVING JURISDICTION AND SHALL CONFORM TO ALL CITY, COUNTY, STATE AND FEDERAL CONSTRUCTION, SAFETY AND SANITARY LAWS, CODES, STATUTES AND ORDINANCES. ALL FEES, TAXES, PERMITS, APPLICATIONS AND CERTIFICATES OF INSPECTION, AND THE FILING OF ALL WORK WITH GOVERNMENTAL AGENCIES SHALL BE THE RESPONSIBILITY OF TH CONTRACTOR. 4. ACH TRADE WILL PROCEED IN A FASHION THAT WILL NOT DELAY TH TRADES FOLLOWING THEM. 5. CONTRACTORS SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS AND/OR SPECIFICATIONS TO THE TRADES UNDER THEIR JURISDICTION. 6. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE, TRUE AND IN PROPER ALIGNMENT. 7. ALL MATERIALS SHALL BE NEW, UNUSED AND OF THE HIGHEST QUALITY IN VERY RESPECT, UNLESS NOTED OTHERWISE. MANUFACTURED MATERIALS AND QUIPMENT SHALL BE INSTALLED PER MANUFACTURER’S RECOMMENDATIONS AND INSTRUCTIONS. 8. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERMS "EQUAL TO", "EQUIVALENT" OR "APPROVED EQUAL" ARE USED, THE DESIGNER SHALL DETERMINE EQUALITY BASED ON INFORMATION SUBMITTED BY THE CONTRACTOR. 9. ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF AT LEAST ONE (1) YEAR FROM APPROVAL FOR FINAL PAYMENT. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED FOR THEIR WORK. 11. CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE OF ACCUMULATION OF WASTE MATERIALS OR RUBBISH; PREMISES TO BE SWEPT CLEAN DAILY OF RELATED CONSTRUCTION DEBRIS. AT THE COMPLETION OF TH WORK, LEAVE THE JOB SITE FREE OF ALL MATERIALS AND BROOM CLEAN. 12. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. LARGER SCAL DRAWINGS SHALL GOVERN SMALLER SCALE. 13. PATCH ALL AREAS WHERE FLOOR IS NOT LEVEL OR TRUE PRIOR TO TH INSTALLATION OF FLOORING OR CARPETING. 14. TO INSURE PROPER AND ADEQUATE BLOCKING, ALL BLOCKING FOR CABINET WORK WILL BE THE RESPONSIBILITY OF THE CABINET CONTRACTOR. 15. UPON COMPLETION OF THE WORK THE CONTRACTOR SHALL WALK THROUGH WITH THE DESIGNER AND COMPILE A "PUNCH LIST" OF CORRECTIONS AND UNSATISFACTORY AND/OR INCOMPLETE WORK. FINAL PAYMENT WILL B CONTINGENT UPON THE COMPLETION OF THESE ITEMS. 16. ANY CHANGE WHICH RESULTS IN EXTRA COST SHALL NOT PROCEED WITHOUT WRITTEN AUTHORIZATION OF THE OWNER AND THE DESIGNER. 17. THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE ARCHITECT OR ENGINEER. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE THROUGHOUT CONSTRUCTION. 18. ANY AMBIGUITIES, DISCREPANCIES, OR CONFLICTS DISCOVERED THROUGH THE USE OF THESE DRAWINGS SHALL BE REPORTED IMMEDIATELY TO TH DESIGNER. FAILURE TO PROVIDE NOTICE TO THE DESIGNER PRIOR TO ANY CONSTRUCTION ACTIVITY SHALL RELIEVE THE DESIGNER OF ALL LIABILITIES AND/OR ANY OTHER CONSEQUENCE. 19. CHANGES TO OR DEVIATIONS FROM THE DRAWINGS MADE WITHOUT TH XPRESS WRITTEN CONSENT OF THE DESIGNER SHALL BE CONSIDERED TO B UNAUTHORIZED AND SHALL RESULT IN THE PARTY MAKING SUCH CHANGES TO OR DEVIATIONS FROM THE DRAWINGS BEING HELD RESPONSIBLE FOR THE CONSEQUENCES RESULTING FROM SUCH CHANGES. GENERAL NOTES AB. ACT A.D. ADD. A.F.F. AGGR. AL. ALT. APPROX. ARCH. BD. BLDG. BLK. BLK’G. BM. BOT. BTWN. B.U.R. B.W. CAB. C.I.P. C.J. CLG. CLKG. CLR. C.M.U. C.O. COL. CONC. CONN. CONSTR. CONT. CPT. C.T. DEG. DEMO. DET./DTL. D.F. DIAG. DIA. DN. DS. DWG. (E) EA. E.J. E.I.F.S. EL./ELEV. ELEC. EMER ENCL. EQ. EQUIP. EQUIV. E.W. E.W.C. EXP. EXT. F F.A. F.D. F.D.C. FDN. F. . F. .C. F.F. F.H.C. FIN. F.L. FLR. FLUOR. FM FND. F.O.B. F.O.C. F.O.S. F.P. F.R. F.S. FT. FTG. FURR. GA. GALV. G.C. G.I. G.L. GR. GWB. GYP. GYP. BD. H.B. H.C. H/C HDR. HDWD. HDWE. H.M. HORIZ. HPL HR. HT. HVAC IBC I.D. INSUL. INT. ANCHOR BOLT ACOUSTICAL CEILING TILE AREA DRAIN ADDENDUM ABOVE FINISHED FLOOR AGGREGATE ALUMINUM ALTERNATE APPROXIMATE ATCHITECT(URAL) BOARD BUILDING BLOCK BLOCKING BEAM BOTTOM BETWEEN BUILT UP ROOFING BOTH WAYS CABINET CAST−IN−PLACE CONTROL JOINT CEILING CAULKING CLEAR CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DEGREE DEMOLITION DETAIL DRINKING FOUNTAIN DIAGONAL DIAMETER DOWN DOWNSPOUT DRAWING EAST EXISTING EACH EXPANSION JOINT EXTERIOR INSULATION AND FINISH SYSTEM ELEVATION ELECTRIC EMERGENCY ENCLOSURE EQUAL EQUIPMENT EQUIVALENT EACH WAY ELECTRIC WATER COOLER EXPANSION EXTERIOR FURNACE FIRE ALARM FLOOR DRAIN FIRE DEPARTMENT CONNECTION FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FIRE HOSE CABINET FINISH FLOW LINE FLOOR FLUORESCENT FACTORY MUTUAL FOUNDATION FACE OF BRICK FACE OF CONCRETE FACE OF STUD FIREPLACE FIRE RETARDANT FULL SIZE FOOT (FEET) FOOTING FURRING GAUGE or GAGE GALVANIZED GENERAL CONTRACTOR GALVANIZED IRON GLASS GRADE GYPSUM WALLBOARD GYPSUM GYPSUM BOARD HOSE BIB HOLLOW CORE HANDICAPPED HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HIGH PRESSURE LAMINATE HOUR HEIGHT HEATING, VENTILATION, AND AIR CONDITIONING INTERNATIONAL BUILDING CODE INSIDE DIAMETER INSULATION INTERIOR JAN. JT. JST. KIT. LAB. LAM. LAV. LT. LWT. MAX. MECH. MEMB. MFR. M.H. MDF MIN. MISC. M.O. MTL. MUL. N (N) N.I.C. NO. NOM. N.T.S. O.C. O.D. OH. OPG. OPP. O.W.S.J. (P) PCT. P.L. P.LAM. PLAS. PLYWD. PR. P.T. Q.T. R. R.D. RE: REFR. REINF. REQ’D. RM. R.O. R.S. R.W. S S.A.C. S.C. SCHED. SECT. S.F. SHT. SIM. S.I.P. SPEC. SQ. S.S. STAGG. STD. STIFF STL. STR. STRUC. SUSP. T T&B TER. T&G THK. T.O. TYP. U.N.O. UL V.B. V.R. VCT VER VERT. V.I.F. W W/ WH W.C. WD. W/O W.P. W.R. W.W.F. @ & ABBREVIATIONS JANITOR JOINT JOIST KITCHEN LABORATORY LAMINATE LAVATORY LIGHT LIGHTWEIGHT MAXIMUM MECHANICAL MEMBRANE MANUFACTURER MANHOLE MEDIUM DENSITY FIBERBOARD MINIMUM MISCELLANEOUS MASONRY OPENING METAL MULLION NORTH NEW NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETE OVERHEAD OPENING OPPOSITE OPEN WEB STEEL JOIST PAINT PRE−CAST PROPERTY LINE PLASTIC LAMINATE PLASTER PLYWOOD PAIR PRESSURE TREATED QUARRY TILE RISER ROOF DRAIN REFER TO ... REFRIGERATOR REINFORCED REQUIRED ROOM ROUGH OPENING ROUGH SAWN (RESAWN) RED WOOD SOUTH SUSPENDED ACOUSTICAL CEILING SOLID CORE SCHEDULE SECTION SQUARE FOOT (FEET) SHEET SIMILAR STRUCTURAL INSULATED PANEL SPECIFICATION(S) SQUARE STAINLESS STEEL STAGGERED STANDARD STIFFENER STEEL STRUCTURAL STRUCTURAL SUSPENDED TREAD TOP AND BOTTOM TERRAZZO TOUNGE AND GROOVE THICK TOP OF TYPICAL UNLESS NOTED OTHERWISE UNDERWRITER’S LABORATORY VAPOR BARRIER VAPOR RETARDER VINYL COMPOSITION TILE VERIFY VERTICAL VERIFY IN FIELD WEST WITH WATER HEATER WATER CLOSET WOOD WITHOUT WATERPROOF(ING) WATER RESISTANT WELDED WIRE FABRIC CENTERLINE PLATE AT AND 1, 2, 6, 8 4 DETAIL STUD/POST SIZE DEVICE MARK HOLDOWN/STRAP SCHEDULE S2 1/2" DIA. X 7" EMBED. A.B. @ 3'-0" O.C. S1 1/2" DIA. X 7" EMBED. A.B. @ 4'-0" O.C. SILL PLATE ANCHORAGE SHEATHING ATTACHMENT 7/16 " APA RATED APA-RATED SHEATHING, 1-SIDE MIN. SHEATHING MARK SHEAR WALL SCHEDULE NOTES: 1. SHEATHING/ATTACHMENT IS REQUIRED THE ENTIRE LENGTH OF WALL INDICATED. WHERE AN EXTERIOR WALL IS NOT DESIGNATED WITH A SHEATHING MARK, PROVIDE SHEATHING AND ATTACHMENT PER TYPE S1 ABOVE. 2. DRIVE WOOD PANEL SHEATHING NAILS FLUSH WITH, BUT NOT PENETRATING THE FACE OF THE WOOD SURFACE. 3. BLOCK ALL EDGES OF SHEAR WALL PANELS (ORIENTED STRAND BOARD, O.S.B. ARE ACCEPTABLE). 4. PROVIDE A MINIMUM OF TWO ANCHOR BOLTS PER EACH SILL PLATE PIECE, NOT MORE THAN 12" OR LESS THAN 4" FROM EACH END. PROVIDE 3" X 3" X 1/4 " PLATE WASHERS AT ALL SILL PLATE ANCHOR BOLTS. 5. STAGGER END JOINTS OF SHEATHING 16" MIN. ON EA. SIDE OF WALL, WHERE SHEATHING IS REQUIRED ON BOTH FACES OF WALL. 6. CONSTRUCT SHEAR WALL ASSEMBLIES, INCLUDING CORNER AND INTERSECTION STUD GROUPS, TOP PLATE SPLICES, AND STUD TO PLATE CONNECTIONS TO COMPLY WITH 2012 INTERNATIONAL BUILDING CODE (IBC) TABLE 2304.9.1, U.N.O. 7. PROVIDE 4X6 OR (2) 2X6 WALL BOTTOM PLATE AND STUDS, DOUG. FIR STUD GRADE, AT ADJOINING PANEL EDGES TO COMPLY WITH IBC 2012 CRITERIA IN SEISMIC CATEGORY D. (2) 2X6 NAILED TOGETHER WITH 16D COMMON AT 3" O.C. STAGGERED. 8. SPRUCE-PINE-FIR WALL STUDS AND 2x SILL PLATES ARE ACCEPTABLE FOR WALLS CONSTRUCTED WITH SHEAR WALL TYPES S1 AND S2 UNLESS OTHERWISE NOTED IN THE GENERAL STRUCTURAL NOTES. 8d @ 3" O.C. EDGE, 12" O.C. FIELD 8d @ 6" O.C. EDGE, 12" O.C. FIELD 7/16 " APA RATED APA-RATED SHEATHING, 1-SIDE MIN. SIMPSON "STHD14" HOLD DOWN STRAP T = 3" MIN. (2) 2X STUDS, B/U, MIN. (30) 16D SINKERS INTO DOUBLE STUD RIM JOIST OR BLOCKING TO SILL OR TOP PLATE BELOW "A35" CLIP @ 2'-8" O.C. "A35" CLIP @ 2'-0" O.C. C1 - SIMPSON HDU4 T = 3" MIN. (1) 2X STUDS, B/U, MIN. PER MANUFACTURERES INSTRUCTIONS W/5/8" EPOXY BOLT W/12" EMBED C2 - 1 Cover PROJECT NAME:OBER RESIDENCE − GARAGE/ADU ADDITION ADDRESS:431 NORTH GRAND OWNER:TRAVIS OBERLEGAL: LOT 5 & 6, BLOCK 7 OF BEALL’S 3RD ADDITION 5−5−2021 REV: NOTES: 1. COORDINATE HOLDOWN LOCATION WITH ARCHITECTURAL FLOOR PLANS AT DOOR/WINDOW LOCATIONS FOR PROPER PLACEMENT AT BEARING/KING STUD ASSEMBLIES. 2. REFER TO THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS. 3. ALTERNATE USE OF A HDU HOLDOWN OF EQUAL VALUE IS ACCEPTABLE. FASTENER SHEATHING LOCATION FLOOR & ROOF DIAPHRAGM FASTENER SCHEDULE 8d COMMON NOTES: 1. DRIVE WOOD PANEL SHEATHING NAILS FLUSH WITH, BUT NOT PENETRATING THE FACE OF THE WOOD SURFACE. FLOOR ROOF 3_ 4 " T&G 1_ 2 " OR 5_ 8 " 24" SPAN RATED SPACING OF FASTENERS 6" O.C. EDGE, 12" O.C. FIELD 8d COMMON 6" O.C. EDGE, 12" O.C. FIELD SHEET NUMBER A0.00 C1.01 D1.01 A1.01 A1.02 A2.01 A2.02 A3.01 E1.01 DRAWING INDEX SHEET NAME COVER SHEET SITE PLAN AS−BUILT PLAN MAIN LEVEL PLAN ROOF PLAN ELEVATIONS PERSPECTIVE ELEVATIONS SECTIONS ELECTRICAL PLANS REVISED ROOF COVER SHEET A0.00