Loading...
HomeMy WebLinkAboutL401IrrigationDetails_04212021PVC MAIN LINEHEATEDENCLOSUREMULCHPVC SLEEVEVALVE, TYP, SEE PLUMBINGHOSE BIB,BLOW OUT ACCESSCOPPER PIPING,SEE PLUMBINGEXTERIORINTERIORBACKFLOWPREVENTERPOLYMER CONCRETEVALVE BOXQUICKCOUPLERFLOOR OF ROOMFINISHED GRADESEE STRUCTURAL FORELEVATION OF SLEEVETHROUGH FOUNDATIONSEE PLUMBINGSECTION VIEW9L401WATER POINT OF CONNECTION SCHEMATIC DETAILSCALE: NOT TO SCALE1L401NOTES:1.TAPE & BUNDLE ALL WIRING AT10'-0" INTERVALS.2.TIE A LOOSE 20" LOOP INWIRING AT ALL CHANGES INDIRECTION GREATER THAN 30°UNTIE ALL LOOPS AFTERMAKING CONNECTIONS.3.BURY MARKING TAPE 6" ABOVEALL DIRECT BURIAL WIRING,LATERAL LINES, AND MAINLINE.4.ALL WIRING UNDER PAVEMENTSHALL BE THROUGH SLEEVES-SEE DETAIL.5.ALL SPLICES SHALL BE MADE INVALVE BOXES AND LOCATED ONAS-BUILT PLANS.TYPICAL SECTIONOF A SHARED TRENCH4"MIN.FINISH GRADELATERALMAINLINELOW VOLTAGEWIRE IN CONDUITIF APPLICABLEBEDDING ASSPECIFIEDBACKFILL WITHEXCAVATIONMATERIAL REMOVEDFROM TRENCH12" MIN. DEPTH2L401IRRIGATION TRENCH1"=1'-0"6" MARKERTAPE, TYP.2" MIN.COVER NOTES:1.ALL IRRIGATION SLEEVINGSHALL BE (2) SIZES LARGERTHAN PIPE OR COMBINATIONOF PIPES THEREIN ENCLOSED,WITH MINIMUM SIZE TO BE 4"SCHEDULE 40 PVC.2.SUPPLY (1) EXTRA SLEEVEWITH EACH IRRIGATIONSLEEVE FOR CONTROL WIRES.BORE UNDER EXISTINGPAVING WHERE REQUIRED.BORE SEPARATELY FORCONTROL WIRES.3.BURY MARKING TAPE ABOVEALL SLEEVES 6" BELOWPAVEMENT.4.INSTALL 3" HT IRRIGATION "I"STAMP IN PAVEMENT WHERESLEEVES ARE LOCATEDUNDER NEW PAVEMENT.5.WHEN TRENCHING PROVIDEA 4" CLEARANCE AROUNDSIDES OF SLEEVES. SLOPESIDES OF TRENCH PER OSHASPECIFICATIONS.SECTION2'-0" 4" MIN.FINISH GRADEIRRIGATION SLEEVECONTROLLERWIRE SLEEVEIF APPLICABLEBEDDING ASSPECIFIEDBACKFILL WITHEXCAVATIONMATERIAL REMOVEDFROM TRENCH6"4" MIN.3L401IRRIGATION SLEEVE1"=1'-0"6" MARKERTAPE, TYP.6" MIN.6" MIN. 18" TYP.NEAREST JOINTIF APPLICABLESTAMPED LETTERPAVEMENTPAVEMENT EDGEPLANEXTEND SLEEVE 1'-0" BEYOND PAVEMENT IRRIGATION SLEEVE2" MIN. COVER 1'-0"NOTES:1.INSTALL VALVE AT HIGHEST POINT ON DISTRIBUTION PIPING.2.VALVE AND PIPING AS SPECIFIED.3.INSTALL ONE DRIP AIR RELIEF VALVE PER DRIP AREA- SEESCHEMATIC DRIP LAYOUT DETAIL. MULTIPLE DRIP AREAS MAY BEWITHIN A SINGLE DRIP ZONE.4.WHEREVER POSSIBLE INSTALL VALVE BOXES IN PLANTING BEDS.SEE IRRIGATION PLAN FOR MORE INFORMATION.14L401DRIP AIR RELIEF VALVE1 1/2"=1'-0"FINISH GRADEVALVE BOXBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVELVALVE BOX COVERDISTRIBUTIONPIPING, TYP.DRIP AIR RELIEF VALVEMULCHDISTRIB.PIPINGDRIP LINE TEE OR ELLDISTRIBUTIONPIPING6L401DRIP MANUAL DRAIN1 1/2"=1'-0"FINISH GRADEVALVE BOXBRICKSUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVELSUMP 12" X 12" X12"VALVE BOXCOVERDRIP LINETEE OR ELLMULCHNOTES:1.INSTALL VALVE AT LOWEST POINT ONDISTRIBUTION PIPING.2.VALVE TO BE SUPPORTED BY GRAVEL,PROVIDE BLOCK SHIM AS REQUIRED.3.VALVE AND PIPING AS SPECIFIED.3.INSTALL ONE DRAIN VALVE PER DRIPAREA- SEE SCHEMATIC DRIP LAYOUTDETAIL. MULTIPLE DRIP AREAS MAYBE WITHIN A SINGLE DRIP ZONE.4.WHEREVER POSSIBLE INSTALL VALVEBOXES IN PLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.DRIP MANUALDRAINNOTES:1.DOUBLE SWINGJOINT SHALL BESCHEDULE 80 PVCNIPPLE WITH (3)MARLEX STREETELBOWS.2.WHEREVERPOSSIBLEINSTALL VALVEBOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.MAINLINE9L401QUICK COUPLER1 1/2"=1'-0"BRICK SUPPORTS,TYP.FINISH GRADEQUICK COUPLER ASSPECIFIEDVALVE BOX WITH COVER3/4" CRUSHEDMINUS GRAVEL24" #4 REBAR WITH CLAMPSDOUBLE SWING JOINTMAIN LINE TEE OR ELLNOTES:1.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.2.SIZE VALVE ANDPIPING ASSPECIFIED.3.WHEREVERPOSSIBLE INSTALLVALVE BOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.5L401ISOLATION VALVE1 1/2"=1'-0"FINISH GRADEGATE OR BALLVALVEVALVE BOX3/4" CRUSHEDMINUS GRAVELBRICK SUPPORTS,TYP.MAINLINEVALVE BOXEXTENSION, TYP.ADD AS NECESSARYVALVE BOX COVERSCHEDULE 80PVC UNION, TYP.NOTES:1.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.2.SIZE VALVE ANDPIPING ASSPECIFIED.3.DIRECT BURIALWIRE MIN. 18/4 WIRETO INTERFACEPANEL. MIN. RUN OF1,000 LF4.WHEREVERPOSSIBLE INSTALLVALVE BOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.FINISH GRADECONTROL VALVEVALVE BOX COVERSCHEDULE 80 PVCUNION, TYP.DECODER SYSTEMIF APPLICABLEMAINLINESERVICE TEE3M DBY-6WATERPROOFCONNECTOR, TYP.18"-24" OFCOILED WIRE7L401DRIP CONTROL VALVE1 1/2"=1'-0"FILTERBRICK SUPPORTS,TYP.3/4" CRUSHEDMINUS GRAVELDISTRIB.PIPINGNOTES:1.VALVE MODELS FORSYSTEM 'A' ANDSYSTEM 'B' ASSPECIFIED IN 329400'PLANTING IRRIGATION'2.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.3.PIPING AS SPECIFIED.4.VALVE SIZE PER L301.5.DIRECT BURIAL WIREMIN. 18/4 WIRE TOINTERFACE PANEL. MIN.RUN OF 1,000 LF6.WHEREVER POSSIBLEINSTALL VALVE BOXESIN PLANTING BEDS.SEE IRRIGATION PLANFOR MOREINFORMATION.CONTROL VALVEBRICKSUPPORTS, TYP.SCHEDULE 80PVC UNION, TYP.DECODERSYSTEM IFAPPLICABLEMAINLINE3/4" CRUSHEDMINUS GRAVELSERVICE TEE8L401ELECTRIC CONTROL VALVE1 1/2"=1'-0"FINISH GRADEVALVE BOXCOVER3M DBY-6WATERPROOFCONNECTOR,TYP.18"-24" OFCOILED WIREDISTRIB.PIPINGNOTES:1.INSTALL VALVE AT HIGHESTPOINT ON MAINLINE.2.VALVE TO BE BRACED BYGRAVEL, PROVIDE REBARSTAKING AS REQUIRED.3.SIZE VALVE AND PIPING ASSPECIFIED.4.WHEREVER POSSIBLE INSTALLVALVE BOXES IN PLANTINGBEDS. SEE IRRIGATION PLANFOR MORE INFORMATION.4L401AIR RELIEF VALVE1 1/2"=1'-0"FINISH GRADEPVC UNIONVALVE BOX3/4" CRUSHEDMINUS GRAVELBRICK SUPPORTS, TYP.SERVICE TEEMAINLINEVALVE BOX COVERBERMAD AIR RELEASE VALVEOR APPROVED EQUALBALL VALVENOTES:1.SEE IRRIGATIONSPECIFICATION AND LEGENDFOR MORE INFORMATION.2.INSTALLATION TO BECOMPLETED INACCORDANCE WITHMANUFACTURER'SSPECIFICATIONS.3.MOUNT WEATHER STATIONWITH CLEAR EXPOSURE TOWEATHER IN LOCATIONSHOWN ON PLANS. MOUNTWITH COMMON SENSE SOAS TO NOT TO VISUALLYDETRACT FROM ITSSURROUNDINGS.4.MOUNT RECEIVER IFAPPLICABLE ON WALL NEXTTO CONTROLLER.5.MOUNT MODULE IFAPPLICABLE WITHIN 6'-0" OFCONTROLLER ON WALL.16L401WEATHER STATION1 1/2"=1'-0"IRRIGATIONCONTROLLERWIRELESSRECEIVERIF APPLICABLESUPPORTINGMODULE IFAPPLICABLEMOUNTING BRACKETWEATHER STATIONEXTERIOR SECTIONSCALE: 1/4" =1'-0EXTERIOR WALL INTERIOR WALL VIEW10'-0" MIN. PER MANUFACTURER, COORDINATE WITH LANDSCAPE ARCHITECTNOTES:1.SEE IRRIGATION SPECIFICATION AND LEGEND FOR MORE INFORMATION.2.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'SSPECIFICATIONS.3.MOUNT CONTROLLER AT EYE LEVEL UNLESS OTHERWISE NOTED.4.CONTROLLER SHALL BE HARD-WIRED TO GROUNDED 110 VAC SOURCE UNLESSOTHERWISE NOTED. COORDINATE INSTALLATION WITH ELECTRICAL.5.PROVIDE IRRIGATION ZONE LIST AS SPECIFIED.15L401CONTROLLER1 1/2"=1'-0"ENSURE MINIMUMCLEARANCE FORDOOR OPENINGCONTROLLERCONDUITCONTROL WIREINTERIOR WALL-SEE PLANIRRIGATION ZONELIST ON SITE PLANCONTROLLERPOWER SOURCEFINISH GRADEELLDEPTH-SEE TRENCHING DETAIL MULCHGEOTEXTILEIF APPLICABLETIE DOWN STAKEPLANTING SOIL13L401DRIP MANIFOLD3"=1'-0"DISTRIBUTION PIPINGDRIP LINERISERNOTES:1.RISER, HEADER, TEES, AND ELLS TO MATCH DISTRIBUTION PIPINGMATERIAL.2.PLACE TIE DOWN STAKES EVERY 3'-0" IN SAND; 4'-0" IN LOAM, 5'-0" INCLAY ON DRIP LINE.3.AT FITTINGS WHERE THERE IS A CHANGE IN DIRECTION USE TIEDOWN STAKES ON EACH LEG OF THE CHANGE OF DIRECTION.HEADER TEE OR ELLMDLINE TO LINECONNECTION TEE, TYPBEDLINELATERAL SUPPLYLINE (PVC), TYP.DRIP ZONE CONTROL KIT,SEE DETAIL, TYP.DRIP LINE TUBING, TYP., MAINTAINCONSISTENT LATERAL SPACINGLENGTH OF LINE NOT TO EXCEEDMANUFACTURER'S SPECIFIEDMAXIMUM BEFORE CONNECTIONBACK TO SUPPLY LINEMANUAL DRAINVALVE AT EACHEND OF LATERALLINE, SEE DETAIL12L401LOOPED DRIP LAYOUT (50 SF OR LESS) NOT TO SCALEADD (2) LINETO LINECONNECTIONSAT TREELOCATIONSNOTES:1.DRIP TUBING TO ALWAYSLOOP, NEVER DEAD END.10L401SCHEMATIC DRIP ZONE LAYOUTNTSNOTES:1.DIAGRAM SHOWN IS SCHEMATIC.LOCATE DRIP MANUAL DRAINS, AIRRELIEF VALVES AND ADJACENTDISTRIBUTION PIPING WITHIN DRIP ZONEPERIMETER- SEE IRRIGATION PLAN.2.INSTALL DRIP AIR RELIEF VALVES AT THEHIGHEST POINTS ON DISTRIBUTIONPIPING. INSTALL ONE VALVE PER EACHDRIP AREA WITHIN THE DRIP ZONE.3.INSTALL DRIP MANUAL DRAINS ATLOWEST POINTS ON DISTRIBUTIONPIPING. INSTALL ONE VALVE PER EACHDRIP AREA WITHIN THE DRIP ZONE.4.SEE DRIP AT CURVED EDGE 11/L401 ANDLOOPED DRIP LAYOUT 12/L401 FORADDITIONAL LAYOUT INFORMATION.DRIP TUBING, TYP.DISTRIBUTION PIPINGMAINLINESUPPLY HEADER, TYP.DRIP AIR RELIEF VALVE,ONE PER ZONE14L40111L401DRIP AT CURVED EDGE SCALE: NOT TO SCALEINLINE DRIP TUBING ASSPECIFIED17mm PLD BLANK TUBINGAS DISCHARGE HEADERINSTALL PLD BLANK TUBINGWITH (3) 2 GPH EMITTERS PERTREE.CLASS 200 PVC SUPPLY LINE OR ASSPECIFIEDMAINTAIN CONSISTENT LATERALSPACINGEDGE OF PLANT BEDDRIPMANIFOLD13L401DRIP CONTROLVALVE7L401DRIP MANUALDRAIN6L401IRRIGATION SLEEVE,TYP, AS NECESSARY3L401CENTER FEED DRIPLAYOUTS ON SUPPLYFROM VALVECLASS 200 PVC EXHAUST LINEMDDRIP AIR RELIEF VALVE,ONE PER ZONE14L401DRIP AIR RELIEF VALVE,ONE PER ZONE14L401DRIP MANUALDRAIN6L401DRIP CONTROLVALVE7L401ADJUSTABLE FLOW BUBBLER (AFB)TREE OR SHRUBTREE BUBBLER SCALE: NOT TO SCALE17L40118"SPIRAL BARB CONNECTIONFLEX TUBING, 20" LENGTHPVC SxSxT TEE FITTING SIZEDFOR LATERAL LINE ANDSPRINKLER INLET1" PVC LATERAL24"INSTALL MOUND AROUND TREESTO HOLD WATERNOTE: ALL TREES IN DRYLANDAND IRRIGATED TURF AREASARE TO BE IRRIGATED WITH ABUBBLER.06.29.17 11:09 PM | L:\UPS_BOZEMAN\BIMCAD\LandArch\UPS_BZMN_L401.dwgL401IRRIGATION DETAILSDONOVAN-DRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®PARCEL DISTRIBUTION FACILITY UPS BOZEMAN, MONTANASITE PLAN SUBMITTAL04.21.20212021Know what'sbelow.Callbefore you dig.